Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
J Chin Med Assoc ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39161202

RESUMEN

BACKGROUND: The present study aimed to investigate whether proper sizing can improve the procedural and clinical outcomes of transcatheter aortic valve replacement (TAVR) with new-generation self-expanding valves (SEVs) and balloon-expandable valves (BEVs) for treating bicuspid aortic stenosis (BAS). METHODS: We retrospectively evaluated consecutive patients who underwent TAVR with Sapien 3 valves (Edwards Lifesciences, Irvine, CA) or Evolut R/PRO valves (Medtronic, Minneapolis, MN) for severe BAS from 2017 to 2022. The primary endpoints were device success rate and major adverse cardiac and cerebral events (MACCEs), including mortality, non-fatal myocardial infarction or disabling stroke, transcatheter heart valve failure, or clinically relevant valve thrombosis during follow-up. Our team employed a complementary approach of supra-annular sizing in addition to the conventional annular sizing method (Wei's method) to guide the TAVR procedures. RESULTS: We recruited a total of 75 consecutive patients, of whom 43 (57%) were treated with BEVs from October 2017 to June 2021, and 32 (43%) were treated with SEVs from July 2021 to December 2022. Device success was similar between the BEV and SEV groups (93% vs. 94%; p > 0.99), and no cases of annular rupture occurred in either group. Similar rates of moderate-to-severe paravalvular leak were observed in the BEV and SEV groups (5% vs. 6%, p > 0.99). At a median follow-up of 464 days, the MACCE rates were comparable between the two groups. In multivariate analysis, the presence of previous percutaneous coronary interventions (hazard ratio: 5.43; p = 0.039) and New York Heart Association functional class III/IV heart failure at 30 days of follow-up after TAVR (hazard ratio: 9.90; p = 0.037) were independently associated with long-term MACCEs. CONCLUSION: Our results demonstrated comparable efficacy and safety for BAS patients undergoing TAVR using either BEVs or SEVs when using Wei's sizing method.

2.
Cureus ; 16(5): e60476, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38883009

RESUMEN

The treatment landscape for psoriatic arthritis (PsA) has evolved significantly with the introduction of biologic therapies, such as adalimumab, which effectively inhibits tumor necrosis factor-alpha (TNF-α) activity. However, despite their efficacy in controlling inflammation, biologic therapies are associated with heightened risks of infectious complications and malignancies. We present a case of a 66-year-old female with PsA treated with adalimumab who presented with recurrent systemic bacterial infections. Despite attempts to adjust dosing intervals to minimize infection risks, the patient experienced severe complications, including urosepsis, endocarditis, and liver abscesses. The dilemma arises in balancing PsA control with anti-TNFα therapy while minimizing infection risks. Current evidence supporting prophylactic antibiotics in such cases is limited, and determining the next steps for treatment involves challenging decisions such as withholding TNF inhibitors or switching to alternative immunomodulators. This case underscores the need for further research into prophylactic treatment and monitoring protocols to manage recurrent infections during anti-TNF-α therapy effectively.

3.
Aging (Albany NY) ; 16(10): 8717-8731, 2024 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-38761181

RESUMEN

BACKGROUND: Valvular heart disease (VHD) is becoming increasingly important to manage the risk of future complications. Electrocardiographic (ECG) changes may be related to multiple VHDs, and (AI)-enabled ECG has been able to detect some VHDs. We aimed to develop five deep learning models (DLMs) to identify aortic stenosis, aortic regurgitation, pulmonary regurgitation, tricuspid regurgitation, and mitral regurgitation. METHODS: Between 2010 and 2021, 77,047 patients with echocardiography and 12-lead ECG performed within 7 days were identified from an academic medical center to provide DLM development (122,728 ECGs), and internal validation (7,637 ECGs). Additional 11,800 patients from a community hospital were identified to external validation. The ECGs were classified as with or without moderate-to-severe VHDs according to transthoracic echocardiography (TTE) records, and we also collected the other echocardiographic data and follow-up TTE records to identify new-onset valvular heart diseases. RESULTS: AI-ECG adjusted for age and sex achieved areas under the curves (AUCs) of >0.84, >0.80, >0.77, >0.83, and >0.81 for detecting aortic stenosis, aortic regurgitation, pulmonary regurgitation, tricuspid regurgitation, and mitral regurgitation, respectively. Since predictions of each DLM shared similar components of ECG rhythms, the positive findings of each DLM were highly correlated with other valvular heart diseases. Of note, a total of 37.5-51.7% of false-positive predictions had at least one significant echocardiographic finding, which may lead to a significantly higher risk of future moderate-to-severe VHDs in patients with initially minimal-to-mild VHDs. CONCLUSION: AI-ECG may be used as a large-scale screening tool for detecting VHDs and a basis to undergo an echocardiography.


Asunto(s)
Inteligencia Artificial , Electrocardiografía , Enfermedades de las Válvulas Cardíacas , Humanos , Electrocardiografía/métodos , Femenino , Masculino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Anciano , Persona de Mediana Edad , Aprendizaje Profundo , Ecocardiografía , Anciano de 80 o más Años
4.
Acta Cardiol Sin ; 40(3): 331-339, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38779166

RESUMEN

Background: The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR). Methods and Results: Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINELTM cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases. Conclusions: Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.

5.
Am Heart J ; 269: 167-178, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38123045

RESUMEN

BACKGROUND: The risks of leaflet thrombosis and the associated cerebral thromboembolism are unknown according to different anticoagulation dosing after transcatheter aortic valve replacement (TAVR). The aim was to evaluate the incidence of leaflet thrombosis and cerebral thromboembolism between low-dose (30 mg) or standard-dose (60 mg) edoxaban and dual antiplatelet therapy (DAPT) after TAVR. METHODS: In this prespecified subgroup analysis of the ADAPT-TAVR trial, the primary endpoint was the incidence of leaflet thrombosis on 4-dimensional computed tomography at 6-months. Key secondary endpoints were new cerebral lesions on brain magnetic resonance imaging and neurological and neurocognitive dysfunction. RESULTS: Of 229 patients enrolled in this study, 118 patients were DAPT group and 111 were edoxaban group (43 [39.1%] 60 mg vs 68 [61.3%] 30 mg). There was a significantly lower incidence of leaflet thrombosis in the standard-dose edoxaban group than in the DAPT group (2.4% vs 18.3%; odds ratio [OR] 0.11; 95% confidence interval [CI], 0.01-0.55; P = .03). However, no significant difference was observed between low-dose edoxaban and DAPT (15.0% vs 18.3%; OR 0.79; 95% CI, 0.32-1.81; P = .58). Irrespective of different antithrombotic regiments, the percentages of patients with new cerebral lesions on brain MRI and worsening neurological or neurocognitive function were not significantly different. CONCLUSIONS: In patients without an indication for anticoagulation after TAVR, the incidence of leaflet thrombosis was significantly lower with standard-dose edoxaban but not with low-dose edoxaban, as compared with DAPT. However, this differential effect of edoxaban on leaflet thrombosis was not associated with a reduction of new cerebral thromboembolism and neurological dysfunction.


Asunto(s)
Estenosis de la Válvula Aórtica , Piridinas , Tiazoles , Tromboembolia , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Inhibidores de Agregación Plaquetaria , Válvula Aórtica/cirugía , Resultado del Tratamiento , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Trombosis/epidemiología , Trombosis/etiología , Trombosis/prevención & control , Anticoagulantes/uso terapéutico , Estenosis de la Válvula Aórtica/complicaciones
6.
JACC Cardiovasc Interv ; 16(24): 2967-2981, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38151311

RESUMEN

BACKGROUND: Subclinical aortic valve complex (valvular and perivalvular) thrombus is not rare after transcatheter aortic valve replacement (TAVR). The risk factors and clinical implications of these findings remain uncertain. OBJECTIVES: This study sought to evaluate the frequency, predictors, and clinical outcome of aortic valve complex thrombus after TAVR. METHODS: In the ADAPT-TAVR (Anticoagulation Versus Dual Antiplatelet Therapy for Prevention of Leaflet Thrombosis and Cerebral Embolization After Transcatheter Aortic Valve Replacement) trial comparing edoxaban vs dual antiplatelet therapy in TAVR patients without an indication for chronic anticoagulation, the frequency of valvular (subclinical leaflet thrombus) and perivalvular (supravalvular, subvalvular, and sinus of Valsalva) thrombus was evaluated by 4-dimensional computed tomography at 6 months. The association of these phenomena with new cerebral thromboembolism on brain magnetic resonance imaging, neurologic and neurocognitive dysfunction, and clinical outcomes was assessed. RESULTS: Among 211 patients with 6-month computed tomography evaluations, 91 patients (43.1%) had thrombus at any aortic valve complex, 30 (14.2%) patients had leaflet thrombus, and 78 (37.0%) patients had perivalvular thrombus. A small maximum diameter of the stent at the valve level and low body surface area were independent predictors of aortic valve complex and perivalvular thrombus, and decreased renal function was an independent predictor of leaflet thrombus. No significant differences were observed in new cerebral lesions, neurologic or neurocognitive functions, or clinical outcomes among patients with or without valvular or perivalvular thrombus. CONCLUSIONS: Subclinical aortic valve complex (valvular and perivalvular) thrombus was common in patients who had undergone successful TAVR. However, these imaging phenomena were not associated with new cerebral thromboembolism, neurologic or neurocognitive dysfunction, or adverse clinical outcomes. (Anticoagulation Versus Dual Antiplatelet Therapy for Prevention of Leaflet Thrombosis and Cerebral Embolization After Transcatheter Aortic Valve Replacement [ADAPT-TAVR]; NCT03284827).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Tromboembolia , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anticoagulantes/uso terapéutico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada Cuatridimensional/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Inhibidores de Agregación Plaquetaria , Factores de Riesgo , Tromboembolia/etiología , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
7.
Eur Heart J Case Rep ; 7(11): ytad516, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38025131

RESUMEN

Background: Ascending aortic pseudoaneurysm due to coronary button dehiscence is a rare, yet life-threatening complication of reconstructive cardiac surgery. Because of its rare entity, large data are lacking, and therefore, treatment guidelines are missing. Case summary: We describe a case of a 53-year-old male with a past medical history of ascending aortic aneurysm and severe aortic regurgitation who underwent Bentall procedure with 26 mm conduit and mechanical aortic valve 1 year before. Follow-up chest computed tomography (CT) revealed coronary button dehiscence with a giant aortic root pseudoaneurysm and mural thrombus inside. Given the risk of rupture, the heart team decided to go for a percutaneous approach. Based on a pre-interventional 3D reconstructed CT scan and guided by transoesophageal echocardiography and intravascular ultrasound, the pseudoaneurysm was successfully occluded with a 6 × 4 mm Amplatzer Duct Occluder II and simultaneous left main coronary artery (LMCA) stenting with a 4.0 × 15 mm drug-eluting stent. Post-procedural chest CT and echocardiography revealed minimal contrast leakage posterior to the aortic root and para LMCA region, confirmed thrombosis formation post occluder and stent deployment, and patent flow of LMCA. Discussion: We describe the successful 3D reconstructed CT scan and peri-procedural transoesophageal echocardiography-guided percutaneous treatment of a giant aortic root pseudoaneurysm with an occluder and a drug-eluting stent with excellent results.

8.
Acta Cardiol Sin ; 39(5): 773-775, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37720411
9.
Eur Heart J Case Rep ; 7(8): ytad357, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37637099

RESUMEN

Background: Transcatheter mitral valve-in-valve (TMVIV) using the Sapien 3 (Edwards Lifesciences, Irvine, CA, USA) transcatheter heart valve is associated with high technical success and sustained valve performance. However, complications may occur or be detected during or after the procedure. Case summary: We herein describe a rare case of a 59-year-old female who underwent TMVIV for a failed surgical mitral bioprosthesis. During the procedure, the device was embolized twice into the left ventricle and left atrium, respectively, resulting from the crimped transcatheter valve partially detaching from the balloon of the Certitude delivery system during passage through a tight transapical sheath. Fortunately, we were able to catch the dislodged valve and anchor it by the partially inflated device balloon, followed by successful repositioning and deployment. Discussion: In cases where the valve has already detached, as in the present case, the sheath may be advanced against the proximal end of the valve as a pusher, providing good support to push the entire system to cross the bioprosthesis. Then, the delivery catheter should be withdrawn with the counteraction of the sheath in order to correct the interrelated positions of the valve and the balloon. Finally, the valve can be positioned and deployed after the sheath is withdrawn.

10.
Heart ; 110(2): 140-147, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-37586823

RESUMEN

OBJECTIVES: The effect of subclinical leaflet thrombosis, characterised by hypoattenuated leaflet thickening (HALT), on the valve haemodynamic function and durability of the bioprosthetic valve, is not yet determined. We determined the impact of HALT on valve haemodynamics after transcatheter aortic valve replacement (TAVR) and the predictors of haemodynamic structural valve deterioration (SVD). METHODS: The Anticoagulation vs Dual Antiplatelet Therapy for Prevention of Leaflet Thrombosis and Cerebral Embolization after Transcatheter Aortic Valve Replacement(ADAPT-TAVR) trial is a multicenter, randomised trial that compared edoxaban and dual antiplatelet therapy in patients who had undergone successful TAVR. The presence of HALT was evaluated by four-dimensional CT at 6 months and serial echocardiography performed at baseline, immediately post-TAVR and after 6 months. SVD was defined as at least one of the following: (1) mean transprosthetic gradient ≥20 mm Hg, (2) change in the mean gradient ≥10 mm Hg from baseline, or (3) new or increase in intraprosthetic aortic regurgitation of at least ≥1 grade, resulting in moderate or greater regurgitation. RESULTS: At 6 months, HALT was found in 30 of 211 (14.2%) patients. The presence of HALT did not significantly affect aortic valve mean gradients (with vs without HALT; 14.0±4.8 mm Hg vs 13.7±5.5 mm Hg; p=0.74) at 6 months. SVD was reported in 30 of 206 patients (14.6%) at 6-month follow-up echocardiography. Older age (OR: 1.138; 95% CI: 1.019 to 1.293; p=0.033), use of aortic valve size ≤23 mm (OR: 6.254; 95% CI: 2.230 to 20.569; p=0.001) and mean post-TAVR pressure gradient (OR: 1.233; 95% CI: 1.123 to 1.371; p<0.001) were independent predictors of haemodynamic SVD; however, the presence of HALT was not identified as a predictor of SVD. CONCLUSIONS: In patients who had undergone successful TAVR, aortic valve haemodynamic status was not influenced by the presence of HALT. Although HALT was not a predictor of haemodynamic SVD at 6 months, it warrants further longer-term follow-up to evaluate the effect on long-term valve durability. TRIAL REGISTRATION NUMBER: NCT03284827 (https://www. CLINICALTRIALS: gov).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemodinámica , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/prevención & control , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...