Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Bone Joint Res ; 13(4): 149-156, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38569600

RESUMEN

Aims: Metal particles detached from metal-on-metal hip prostheses (MoM-THA) have been shown to cause inflammation and destruction of tissues. To further explore this, we investigated the histopathology (aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL) score) and metal concentrations of the periprosthetic tissues obtained from patients who underwent revision knee arthroplasty. We also aimed to investigate whether accumulated metal debris was associated with ALVAL-type reactions in the synovium. Methods: Periprosthetic metal concentrations in the synovia and histopathological samples were analyzed from 230 patients from our institution from October 2016 to December 2019. An ordinal regression model was calculated to investigate the effect of the accumulated metals on the histopathological reaction of the synovia. Results: Median metal concentrations were as follows: cobalt: 0.69 µg/g (interquartile range (IQR) 0.10 to 6.10); chromium: 1.1 µg/g (IQR 0.27 to 4.10); and titanium: 1.6 µg/g (IQR 0.90 to 4.07). Moderate ALVAL scores were found in 30% (n = 39) of the revised knees. There were ten patients with an ALVAL score of 6 or more who were revised for suspected periprosthetic joint infection (PJI), aseptic loosening, or osteolysis. R2 varied between 0.269 and 0.369 for the ordinal regression models. The most important variables were model type, indication for revision, and cobalt and chromium in the ordinal regression models. Conclusion: We found that metal particles released from the knee prosthesis can accumulate in the periprosthetic tissues. Several patients revised for suspected culture-negative PJI had features of an ALVAL reaction, which is a novel finding. Therefore, ALVAL-type reactions can also be found around knee prostheses, but they are mostly mild and less common than those found around metal-on-metal prostheses.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 1018-1025, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36205761

RESUMEN

PURPOSE: This study investigates whether thicker (PE) inserts lead to a greater risk for revision after TKA. The differences between the TKA designs of three manufacturers (NexGen, PFC Sigma, Triathlon) are also compared. METHODS: A total of 7643 primary TKA surgeries were included. PE inserts were divided into two groups-"thick PE inserts" with a thickness of 13 mm (mm) or more and "standard PE inserts" with a thickness of less than 13 mm. Three cruciate-retaining (CR) TKA designs (NexGen, PFC Sigma, Triathlon) were included in the study. The differences in failure rates between groups were investigated using Kaplan-Meier survival curves and Cox regression model with hazard ratios (HR). Failure rates were investigated short-term (< 2 years) and long-term (the whole follow-up period). The TKA designs were analysed both together and separately. RESULTS: During the whole follow-up period, there were 184 (2.4%) aseptic revisions. The thick PE insert group showed an increased risk for revision compared to the standard PE insert group in both short-term (< 2 years; HR 2.0, CI 1.3 to 3.2) and long term (> 2 years; HR 1.6, CI 1.1 to 2.3) follow-up. The highest revision rate was observed in patients who received the Triathlon TKA with a thicker PE insert (HR 2.6, CI 1.2 to 5.7). CONCLUSION: The results indicate that thicker PE inserts are associated with increased risk for revision in primary TKA. Further research is required to ascertain whether more conformed PE inserts or constrained knee designs instead of thick CR inserts will ultimately lead to better clinical outcomes. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Articulación de la Rodilla/cirugía , Reoperación
3.
J Biomed Mater Res B Appl Biomater ; 108(3): 1085-1096, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31410972

RESUMEN

We aimed to establish latent subtypes of histopathological patterns in failed metal-on-metal hip replacements. Tissue samples of the synovia from the neocapsule were retrieved from 284 revised ASR (Articular Surface Replacement) hip replacements and analyzed histologically. Hierarchical cluster analysis and polytomous latent class analysis were performed to establish the underlying structure and relationships of the histological observations and to find similar cohorts of cases. Clustering analyses suggested four distinct subtypes that could be readily and reasonably labeled and mapped against a recent consensus statement. The first two subtypes showed synovial necrosis, lymphocyte sheets, and abundant or thin histiocyte sheets. In addition, the first subtype showed abundant germinal centers and no metal particles either extracellularly or intracellularly. Metal particles were, however, seen in the second subtype. Hence, the first subtype was labeled "immunologic Type IV neosynovitis" and the second subtype "abrasion-induced inflammatory lymphocytic Type I neosynovitis." The third and fourth subtypes showed no perivascular and diffuse lymphocytes, but a higher number of metal particles intracellularly and extracellularly. The third subtype had synovial necrosis along with granulomas and was labeled "abrasion-induced necrotic Type I neosynovitis," whereas the fourth subtype had readily intact synovial lining, and this subtype was labeled "abrasion-induced foreign body Type I neosynovitis." Histopathological findings in failed MoM hips are not just one wide entity. These hips evince four different histological patterns that also differ at the macroscopic level. Moreover, the often stated "ALVAL-type reaction" seems to be dualistic in nature, which is a novel finding.


Asunto(s)
Análisis de Clases Latentes , Prótesis Articulares de Metal sobre Metal , Falla de Prótesis , Artroplastia de Reemplazo de Cadera , Análisis por Conglomerados , Reacción a Cuerpo Extraño/patología , Articulación de la Cadera/patología , Prótesis de Cadera , Humanos , Linfocitos/metabolismo , Ensayo de Materiales , Metales , Diseño de Prótesis , Reoperación , Reproducibilidad de los Resultados
4.
BMC Musculoskelet Disord ; 20(1): 195, 2019 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-31054584

RESUMEN

BACKGROUND: Adverse Reaction to Metal Debris (ARMD) is a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. Most failures are related to excessively wearing implant producing harmful metal debris (extrinsic factor). As ARMD may also occur in patients with low-wearing implants, it has been suggested that there are differences in host-specific intrinsic factors contributing to the development of ARMD. However, there are no studies that have directly assessed whether the development of ARMD is actually affected by these intrinsic factors. METHODS: We included all 29 patients (out of 33 patients) with sufficient data who had undergone bilateral revision of ASR MoM hips (58 hips) at our institution. Samples of the inflamed synovia and/or pseudotumour were obtained perioperatively and sent to histopathological analysis. Total wear volumes of the implants were assessed. Patients underwent MARS-MRI imaging of the hips preoperatively. Histological findings, imaging findings and total wear volumes between the hips of each patient were compared. RESULTS: The difference in wear volume between the hips was clinically and statistically significant (median difference 15.35 mm3, range 1 to 39 mm3, IQR 6 to 23 mm3) (p < 0.001). The median ratio of total wear volume between the hips was 2.0 (range 1.09 to 10.0, IQR 1.67 to 3.72). In majority of the histological features and in presence of pseudotumour, there were no differences between the left and right hip of each patient (p > 0.05 for all comparisons). These features included macrophage sheet thickness, perivascular lymphocyte cuff thickness, presence of plasma cells, presence of diffuse lymphocytic infiltration and presence of germinal centers. CONCLUSIONS: Despite the significantly differing amounts of wear (extrinsic factor) seen between the sides, majority of the histological findings were similar in both hips and the presence of pseudotumour was symmetrical in most hips. As a direct consequence, it follows that there must be intrinsic factors which contribute to the symmetry of the findings, ie. the pathogenesis of ARMD, on individual level. This has been hypothesized in the literature but no studies have been conducted to confirm the hypothesis. Further, as the threshold of metal debris needed to develop ARMD appears to be largely variable based on the previous literature, it is likely that there are between-patient differences in these intrinsic factors, ie. the host response to metal debris is individual.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Reacción a Cuerpo Extraño/inmunología , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales/inmunología , Falla de Prótesis/etiología , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Reacción a Cuerpo Extraño/inducido químicamente , Reacción a Cuerpo Extraño/patología , Reacción a Cuerpo Extraño/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/patología , Articulación de la Cadera/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Metales/efectos adversos , Persona de Mediana Edad , Reoperación/estadística & datos numéricos
5.
PLoS One ; 13(5): e0197614, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29768492

RESUMEN

Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Articulación de la Cadera/patología , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales/análisis , Líquido Sinovial/química , Anciano , Cromo/análisis , Cromo/sangre , Cobalto/análisis , Cobalto/sangre , Femenino , Humanos , Masculino , Metales/sangre , Molibdeno/análisis , Molibdeno/sangre , Falla de Prótesis , Titanio/análisis , Titanio/sangre
6.
BMC Musculoskelet Disord ; 18(1): 523, 2017 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-29228956

RESUMEN

BACKGROUND: Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. METHODS: Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. RESULTS: Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. CONCLUSIONS: Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Inflamación/patología , Prótesis Articulares de Metal sobre Metal/efectos adversos , Falla de Prótesis/efectos adversos , Acetábulo/patología , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Cabeza Femoral/patología , Estudios de Seguimiento , Articulación de la Cadera/metabolismo , Articulación de la Cadera/patología , Articulación de la Cadera/cirugía , Humanos , Inflamación/sangre , Inflamación/etiología , Iones/sangre , Masculino , Metales/efectos adversos , Metales/sangre , Persona de Mediana Edad , Necrosis/etiología , Necrosis/patología , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Líquido Sinovial/química , Factores de Tiempo
7.
Acta Orthop ; 88(5): 478-483, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28715928

RESUMEN

Background and purpose - Orthopedics and especially joint replacement surgery have had more than their fair share of unsuccessful innovations that have violated widely endorsed principles for the introduction of new surgical innovations. We aimed to investigate (1) the trends in the use of the Birmingham Hip Resurfacing (BHR), the ASR hip resurfacing (ASR HRA) and the ASR XL total hip replacement (ASR XL THR) system with very different market approval processes and (2) whether their use was corroborated by clinical trials published in the peer-reviewed literature. Methods - The literature was searched for any clinical studies that reported outcomes of the BHR, ASR HRA and ASR XL THRs. Data from 7 national hip arthroplasty registers were collected and the number of annually implanted devices was matched to those reported in the literature. Results - The cumulative number of implanted and published BHRs grew proportionally with a small lag. The growth of implanted BHRs started to decline at the same time as the ASR HR was introduced. With regard to ASR HRAs, the cumulative proportion of implanted hips and those included in the published studies grew disproportionately after the introduction of the ASR in 2003. For ASR XL THRs, the disproportionality is even higher. Interpretation - The adoption of ASR hip replacements did not follow the proposed stepwise introduction of orthopedic implants. The adoption and use of any new implant should follow a strict guideline and algorithm even if the theoretical basis or the results of preclinical studies are excellent.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Difusión de Innovaciones , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...