Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Paediatr Anaesth ; 25(12): 1241-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26417722

RESUMEN

INTRODUCTION: We assessed the feasibility of blind orotracheal intubation in children using the Air-QILA as a conduit in supine position and the glottic view grading by fiberoptic bronchoscope (FOB) through it both in supine and lateral positions. METHODS: After ethical approval and consent, 60 children were enrolled in the study. In the operating room, after attaching standard monitors to all children, anesthesia was induced with sevoflurane (2-8%) in oxygen (100%). Once the children became sedated, an i.v. access was established and injection glycopyrrolate (10 µg · kg(-1)), fentanyl (2 µg · kg(-1)), and atracurium (0.5 mg · kg(-1)) were administered. After 3 min, the Air-QILA was placed in supine position and glottic view was assessed by using FOB, in supine and right lateral decubitus position. In all children, gradings of glottic view in two different positions were noted. After that all children were turned supine, and orotracheal intubation was done blindly through the Air-QILA. The success rate, insertion time of the Air-QILA, and endotracheal intubation were noted. RESULTS: The Air-QILA placement was successful in 57 children in first attempt and three children required second attempt. However, blind endotracheal intubations through the Air-QILA were successful in 38 children in first attempt and 12 children required second attempt. In the remaining 10 children, where blind endotracheal intubation through the Air-QILA remained unsuccessful, conventional laryngoscopy was performed. In supine and lateral positions, Grade 1 glottic view was seen in 41 and 38 of total 60 patients, respectively. Turning of all children from supine to lateral decubitus position resulted in the deterioration of grading of glottic view in eight children and improvement in two children (P = 0.001). CONCLUSION: The Air-QILA is an easy to place supraglottic airway device with excellent airway seal and low airway morbidity. It may be useful as a conduit for blind orotracheal intubation in supine position and can be used as an effective alternative to FOB in low resource settings.


Asunto(s)
Glotis/anatomía & histología , Máscaras Laríngeas , Posicionamiento del Paciente/métodos , Posición Supina , Manejo de la Vía Aérea , Anestesia por Inhalación , Broncoscopios , Niño , Preescolar , Estudios de Factibilidad , Femenino , Tecnología de Fibra Óptica , Humanos , Lactante , Recién Nacido , Intubación Intratraqueal/instrumentación , Laringoscopía , Masculino
2.
Clin Orthop Surg ; 7(2): 211-6, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26217468

RESUMEN

BACKGROUND: Total knee arthroplasty (TKA) is associated with considerable blood loss. Computer-assisted surgery (CAS) is different from conventional TKA as it avoids opening the intramedullary canal. Hence, CAS should be associated with less blood loss. METHODS: Fifty-seven patients were randomized into two groups of CAS and conventional TKA. In conventional group intramedullary femoral and extramedullary tibial jigs were used whereas in CAS group imageless navigation system was used. All surgeries were done under tourniquet. Total and hidden blood loss was calculated in both groups and compared. RESULTS: The mean total blood loss was 980 mL in conventional group and 970 mL in CAS group with median of 1,067 mL (range, 59 to 1,791 mL) in conventional group and 863 mL (range, 111 to 2,032 mL) in CAS group. There was no significant difference in total blood loss between the two groups (p = 0.811). We have found significant hidden blood loss in both techniques, which is 54.8% of the total loss in the conventional technique and 59.5% in the computer-assisted navigation technique. CONCLUSIONS: There is no significant difference in total and hidden blood loss in the TKA in CAS and conventional TKA. However, there is significant hidden blood loss in both techniques. There was no relation of tourniquet time with blood loss.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Pérdida de Sangre Quirúrgica/prevención & control , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Cirugía Asistida por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Torniquetes
3.
J Bone Joint Surg Am ; 97(11): 889-94, 2015 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-26041849

RESUMEN

BACKGROUND: Conventional total knee arthroplasty is performed with use of an intramedullary alignment guide, which produces elevated intramedullary pressure that can create fat emboli. Total knee arthroplasty performed via computer-assisted surgery does not require an intramedullary femoral rod, raising the question of whether computer-assisted surgery generates less embolic material than conventional total knee arthroplasty. The purpose of this study was to compare the emboli produced in the two techniques. METHODS: Fifty-seven patients were randomized into two groups: the computer-assisted surgery group (n = 29) and the conventional total knee arthroplasty group (n = 28). An intramedullary femoral alignment jig was used in the conventional total knee arthroplasty group but not in the computer-assisted surgery group. Intraoperative invasive monitoring was performed with use of transesophageal echocardiography and a pulmonary artery catheter. RESULTS: The mean embolic score was 6.21 points for the conventional technique group and 5.48 points for the computer-assisted surgery group (p = 0.0161). After tourniquet deflation, fat emboli were observed in the blood of five patients in the conventional surgery group and one patient in the computer-assisted surgery group. CONCLUSIONS: The patients in the computer-assisted surgery group had lower embolic loads compared with the patients in the conventional total knee arthroplasty group. In patients with an uncompromised cardiopulmonary system, the embolic load difference between the techniques was not clinically relevant. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Embolia Grasa/etiología , Cirugía Asistida por Computador/efectos adversos , Presión Sanguínea/fisiología , Ecocardiografía Transesofágica , Embolia Grasa/fisiopatología , Femenino , Cardiopatías/etiología , Humanos , Complicaciones Intraoperatorias/etiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Embolia Pulmonar/etiología , Método Simple Ciego , Torniquetes/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...