Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 315
Filtrar
1.
Struct Heart ; 8(5): 100333, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39290680

RESUMEN

Background: The implications of pulmonary vein (PV) flow patterns in patients with heart failure (HF) and mitral regurgitation (MR) are uncertain. We examined PV flow patterns in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (COAPT) trial (NCT01626079), in which patients with HF and moderate-to-severe or severe functional MR were randomized to transcatheter edge-to-edge repair (TEER) with the MitraClip device plus guideline-directed medical therapy (GDMT) vs. GDMT alone. We sought to evaluate the prognostic utility of baseline PV systolic flow reversal (PVSFR) in HF patients with severe MR and to determine whether the presence of PVSFR can discriminate patients most likely to benefit from TEER in COAPT trial patients. Methods: Patients were categorized by the echocardiographic core laboratory-assessed baseline presence of PVSFR. Two-year outcomes were examined according to PVSFR and treatment. Results: Baseline PV flow patterns were evaluable in 526/614(85.7%) patients, 48.9% of whom had PVSFR. Patients with PVSFR had more severe MR, reduced stroke volume and cardiac output, greater right ventricular dysfunction, and worse hemodynamics. By multivariable analysis, PVSFR was not an independent predictor of 2-year all-cause death, or heart failure hospitalization (HFH). The reductions in the 2-year rates of all-cause death and HFH with TEER compared with GDMT alone were similar in patients with and without PVSFR (Pinteraction = 0.40 and 0.12, respectively). The effect of TEER on improving Kansas City Cardiomyopathy Questionnaire scores and 6-minute walk distance were also independent of PVSFR. Conclusions: In the COAPT trial, PVSFR identified HF patients with severe MR and more advanced heart disease. Patients with and without PVSFR had consistent reductions in mortality, HFH, and improved quality-of-life and functional capacity after TEER. Clinical Trial Registration: ClinicalTrial.gov IdentifierNCT01626079.

4.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101345, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-39132458

RESUMEN

Background: Transcatheter edge-to-edge repair (TEER) improved outcomes in patients with heart failure (HF) and severe secondary mitral regurgitation (SMR) compared with guideline-directed medical therapy (GDMT) alone regardless of the severity of baseline left ventricular ejection fraction (LVEF). The study aimed to evaluate the effect of early changes in LVEF after TEER and GDMT alone in patients with HF and severe SMR. Methods: Within the COAPT trial, we evaluated outcomes according to changes in LVEF from baseline to 30 days. The primary outcome was all-cause death or HF hospitalization (HFH) between 30 days and 2 years. Results: Among 432 patients with paired echocardiographic data, 182 (42.1%) had increased LVEF (LVEF change 6.0% ± 4.9%) and 250 (57.9%) had a decrease or no change in LVEF (LVEF change -6.6% ± 5.6%) from baseline to 30 days. LVEF at 30 days increased more frequently with GDMT alone compared with TEER plus GDMT (51.4% vs 33.0%; P = .0001). Between 30 days and 2 years, there were no significant differences in death or HFH in the increase LVEF and the decrease LVEF groups (58.8% vs 51.4%; multivariable-adjusted HR, 0.97; 95% CI, 0.87-1.08; P = .59). TEER plus GDMT reduced the 30-day to 2-year rate of death or HFH compared with GDMT alone consistently in patients with increase LVEF and decrease LVEF (Pint = 0.75). Conclusions: Among patients with HF and severe SMR, early improvements in LVEF were more frequent with GDMT alone compared with TEER plus GDMT but were not associated with subsequent outcomes at 2 years. TEER reduced death or HFH during 2-year follow-up irrespective of early LVEF changes.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

7.
Am J Cardiol ; 225: 125-133, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38925261

RESUMEN

Low-flow (LF) aortic stenosis (AS) is common among older adults and associated with worse outcomes than AS with normal stroke volume. It is unknown whether left ventricular (LV) remodeling identifies patients with LF AS at higher risk of complications. LV remodeling was evaluated in 463 patients with severe LF AS referred for transcatheter aortic valve replacement (TAVR) and classified as adaptive (normal geometry and concentric remodeling) or maladaptive (concentric and eccentric hypertrophy) using the American Society of Echocardiography gender-specific criteria. Of these, the 390 patients who underwent TAVR were followed for the end points of heart failure (HF) hospitalization and all-cause mortality. The mean patient age was 79 (74.5 to 84) years. LV remodeling was adaptive in 57.4% (62 normal geometry, 162 concentric remodeling) and maladaptive in 42.6% (127 concentric hypertrophy, 39 eccentric hypertrophy). During a median follow-up of 3 years, 45 patients (11.5%) were hospitalized for HF and 73 (18.7%) died. After adjustment for widely used echocardiographic parameters, maladaptive remodeling was independently associated with HF hospitalization and death (adjusted hazard ratio 1.75, confidence interval 1.03 to 3.00). There was no significant difference between men and women in the association of maladaptive LV remodeling with the composite outcome (p = 0.40 for men and p = 0.06 for women). In conclusion, in patients with LF AS, maladaptive LV remodeling before TAVR is independently associated with higher incidences of postprocedural HF rehospitalization and death in both men and women. Assessment of LV remodeling has prognostic value over and above LV ejection fraction and may improve risk stratification for patients with LF AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Reemplazo de la Válvula Aórtica Transcatéter , Remodelación Ventricular , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Masculino , Femenino , Remodelación Ventricular/fisiología , Anciano , Anciano de 80 o más Años , Volumen Sistólico/fisiología , Insuficiencia Cardíaca/fisiopatología , Estudios Retrospectivos , Estudios de Seguimiento , Hospitalización/estadística & datos numéricos
8.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38795109

RESUMEN

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía de Estrés , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Curva ROC , Función Ventricular Izquierda , Área Bajo la Curva , Volumen Sistólico , Hemodinámica
10.
J Invasive Cardiol ; 36(9)2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38787923
11.
J Am Coll Cardiol ; 83(18): 1779-1798, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38692829

RESUMEN

Right ventricular infarction (RVI) complicates 50% of cases of acute inferior ST-segment elevation myocardial infarction, and is associated with high in-hospital morbidity and mortality. Ischemic right ventricular (RV) systolic dysfunction decreases left ventricular preload delivery, resulting in low-output hypotension with clear lungs, and disproportionate right heart failure. RV systolic performance is generated by left ventricular contractile contributions mediated by the septum. Augmented right atrial contraction optimizes RV performance, whereas very proximal occlusions induce right atrial ischemia exacerbating hemodynamic compromise. RVI is associated with vagal mediated bradyarrhythmias, both during acute occlusion and abruptly with reperfusion. The ischemic dilated RV is also prone to malignant ventricular arrhythmias. Nevertheless, RV is remarkably resistant to infarction. Reperfusion facilitates RV recovery, even after prolonged occlusion and in patients with severe shock. However, in some cases hemodynamic compromise persists, necessitating pharmacological and mechanical circulatory support with dedicated RV assist devices as a "bridge to recovery."


Asunto(s)
Ventrículos Cardíacos , Disfunción Ventricular Derecha , Humanos , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/etiología , Ventrículos Cardíacos/fisiopatología , Infarto del Miocardio/fisiopatología
12.
Artículo en Inglés | MEDLINE | ID: mdl-38749898

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has undergone significant advances in recent years, with the development of improved pre-planning tools and devices. These advances have led to a reduction in the rate of paravalvular leak (PVL), a complication that is associated with poor outcomes even when mild. As some centers around the world are moving to solely fluoroscopy-focused implantation, we aimed to describe the clinical impact of intra-procedural transthoracic echocardiography (TTE) during TAVI in a high volume hospital. METHODS: Observational study during a 3-month period. A limited TTE examination was performed immediately after deployment to assess the existence of PVL and grade its severity. Complete TTE was performed a day after the procedure. In case of ≥mild PVL after valve deployment, a decision was made according to the severity of the PVL, patient anatomy and extent of annular calcification to preform balloon post-dilation. If done, an additional limited TTE was performed to assess possible complication and the degree of PVL post dilatation. RESULTS: 115 patient were included in the study. Intra-procedural TTE identified 16 patients (14 %) with at least mild PVL, three of them with moderate (3 %). Post balloon dilatation was performed in 10 patients (9 % of the cohort) with significant improvement in the degree of PVL. CONCLUSION: Intra-procedural TTE immediately after TAVI deployment can accurately identify PVL, allowing operators to perform post balloon dilatation with improvement in early echocardiographic results. Our findings support the routine use of TTE during procedures, without relying solely on fluoroscopy.

13.
J Am Coll Cardiol ; 83(19): 1917-1935, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38719371

RESUMEN

Ventricular aneurysm represents a rare complication of transmural acute myocardial infarction, although other cardiac, congenital, or metabolic diseases may also predispose to such condition. Ventricular expansion includes all the cardiac layers, usually with a large segment involved. Adverse events include recurrent angina, reduced ventricular stroke volume with congestive heart failure, mitral regurgitation, thromboembolism, and ventricular arrhythmias. Multimodality imaging is paramount to provide comprehensive assessment, allowing for appropriate therapeutic decision-making. When indicated, surgical intervention remains the gold standard, although additional therapy (heart failure, anticoagulation, and advanced antiarrhythmic treatment) might be required. However, the STICH (Surgical Treatment for Ischemic Heart Failure) trial did not show any advantage from adding surgical ventricular reconstruction to coronary artery bypass surgery in terms of survival, rehospitalization or symptoms, compared with revascularization alone. Finally, implantable cardiac defibrillator may reduce the risk of fatal arrhythmias.


Asunto(s)
Aneurisma Cardíaco , Infarto del Miocardio , Humanos , Aneurisma Cardíaco/etiología , Aneurisma Cardíaco/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Infarto del Miocardio/complicaciones
14.
J Invasive Cardiol ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38776477

RESUMEN

A 93-year-old woman with symptomatic severe aortic stenosis and normal biventricular function was referred for transcatheter aortic valve replacement (TAVR) evaluation. Cardiac computed tomography revealed safe coronary heights and multiple large calcified mobile mass-like structures attached to the aortic valve (AV), confirmed also by transesophageal echocardiography, which were thought to be prominent Lambl's excrescences.

16.
J Am Med Inform Assoc ; 31(9): 2097-2102, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38687616

RESUMEN

OBJECTIVES: The study developed framework that leverages an open-source Large Language Model (LLM) to enable clinicians to ask plain-language questions about a patient's entire echocardiogram report history. This approach is intended to streamline the extraction of clinical insights from multiple echocardiogram reports, particularly in patients with complex cardiac diseases, thereby enhancing both patient care and research efficiency. MATERIALS AND METHODS: Data from over 10 years were collected, comprising echocardiogram reports from patients with more than 10 echocardiograms on file at the Mount Sinai Health System. These reports were converted into a single document per patient for analysis, broken down into snippets and relevant snippets were retrieved using text similarity measures. The LLaMA-2 70B model was employed for analyzing the text using a specially crafted prompt. The model's performance was evaluated against ground-truth answers created by faculty cardiologists. RESULTS: The study analyzed 432 reports from 37 patients for a total of 100 question-answer pairs. The LLM correctly answered 90% questions, with accuracies of 83% for temporality, 93% for severity assessment, 84% for intervention identification, and 100% for diagnosis retrieval. Errors mainly stemmed from the LLM's inherent limitations, such as misinterpreting numbers or hallucinations. CONCLUSION: The study demonstrates the feasibility and effectiveness of using a local, open-source LLM for querying and interpreting echocardiogram report data. This approach offers a significant improvement over traditional keyword-based searches, enabling more contextually relevant and semantically accurate responses; in turn showing promise in enhancing clinical decision-making and research by facilitating more efficient access to complex patient data.


Asunto(s)
Ecocardiografía , Registros Electrónicos de Salud , Procesamiento de Lenguaje Natural , Humanos , Cardiopatías/diagnóstico por imagen , Confidencialidad , Almacenamiento y Recuperación de la Información/métodos
17.
Am J Cardiol ; 221: 84-93, 2024 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-38649128

RESUMEN

A substantial number of patients may experience systemic inflammatory response syndrome (SIRS) and related adverse events after transcatheter aortic valve implantation and endovascular aortic aneurysm repair. Although a clear etiology has not been established, endothelial disruption and tissue-ischemic response secondary to the foreign material may represent the trigger events. A latency period (0 to 48 hours) may occur between the initial injury and onset of symptoms mirroring an initial local response followed by a systemic response. Clinical presentation can be mild or severe depending on external triggers and characteristics of the patient. Diagnosis is challenging because it simulates an infection, but lack of response to antibiotics, negative cultures are supportive of SIRS. Increased in-hospital stay, readmissions, major cardiovascular events, and reduced durability of the device used are the main complications. Treatment includes non-steroidal anti-inflammatory drugs or corticosteroids. In conclusion, further studies are warranted to fully explore pathophysiologic mechanisms underpinning SIRS and the possibility of enhancing device material immune compatibility to reduce the inflammatory reaction of the host tissue.


Asunto(s)
Complicaciones Posoperatorias , Síndrome de Respuesta Inflamatoria Sistémica , Humanos , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica/terapia , Pronóstico , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/terapia , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Antiinflamatorios no Esteroideos/uso terapéutico
18.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456886

RESUMEN

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Tomografía Computarizada Multidetector
19.
Comput Biol Med ; 172: 108191, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38457932

RESUMEN

Bicuspid aortic valve (BAV), the most common congenital heart disease, is prone to develop significant valvular dysfunction and aortic wall abnormalities such as ascending aortic aneurysm. Growing evidence has suggested that abnormal BAV hemodynamics could contribute to disease progression. In order to investigate BAV hemodynamics, we performed 3D patient-specific fluid-structure interaction (FSI) simulations with fully coupled blood flow dynamics and valve motion throughout the cardiac cycle. Results showed that the hemodynamics during systole can be characterized by a systolic jet and two counter-rotating recirculation vortices. At peak systole, the jet was usually eccentric, with asymmetric recirculation vortices and helical flow motion in the ascending aorta. The flow structure at peak systole was quantified using the vorticity, flow rate reversal ratio and local normalized helicity (LNH) at four locations from the aortic root to the ascending aorta. The systolic jet was evaluated with the peak velocity, normalized flow displacement, and jet angle. It was found that peak velocity and normalized flow displacement (rather than jet angle) gave a strong correlation with the vorticity and LNH in the ascending aorta, which suggests that these two metrics could be used for clinical noninvasive evaluation of abnormal blood flow patterns in BAV patients.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Aorta , Hemodinámica/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...