Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Langmuir ; 34(4): 1400-1409, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29290116

RESUMEN

N3-functionalized monolayers on silicon wafer substrates are prepared via the controlled vapor-phase deposition of 11-azidoundecyltrimethoxysilanes at reduced pressure and elevated temperature. The quality of the layer is assessed using contact angle, attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), and ellipsometry measurements. At 60 °C, longer deposition times are needed to achieve monolayers with similar N3 density compared to depositions at 145 °C. The monolayers formed via the vapor phase are denser compared to those formed via a solvent-based deposition process. ATR-FTIR measurements confirm the incorporation of azido-alkyl chains in the monolayer and the formation of siloxane bridges with the underlying oxide at both deposition temperatures. X-ray photon spectroscopy shows that the N3 group is oriented upward in the grafted layer. Finally, the density was determined using total reflection X-ray fluorescence after a click reaction with chlorohexyne and amounts to 2.5 × 1014 N3 groups/cm2. In summary, our results demonstrate the formation of a uniform and reproducible N3-containing monolayer on silicon wafers, hereby providing a functional coating that enables click reactions at the substrate.

2.
Bioelectrochemistry ; 112: 61-6, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27472099

RESUMEN

Multitarget biosensors hold great promise to improve point-of-care diagnostics as they enable simultaneous detection of different biomolecular markers. Multiplexed detection of different markers, like genes, proteins, or a combination of both, propels advancement in numerous fields such as genomics, medical diagnosis and therapy monitoring. The functionalization of these biosensors, however, necessitates patterned immobilization of different bioreceptors, which remains challenging and time-consuming. We demonstrate a simple method for the patterned multiplexing of bioreceptors on a multi-electrode chip. By using the lithographically defined electrodes for surface functionalization, additional patterning steps become obsolete. Using the electrodes for self-aligned immobilization provides a spatial resolution that is limited by the electrode patterning process and that cannot be easily obtained by alternative dispensing or coating techniques. Via electrochemical reduction of diazonium salts combined with click chemistry, we achieved site-specific immobilization of two different ssDNA probes side by side on a single chip. This method was experimentally verified by cyclic voltammetry (CV), Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS), and specific target recognition was visualized by fluorescence microscopy. The combination of the electroaddressability of electrografting with the chemoselectivity of click chemistry, offers a versatile platform for highly efficient site-specific functionalization of multitarget biosensors.


Asunto(s)
Técnicas Biosensibles/instrumentación , Compuestos de Anilina/química , Sondas de ADN/química , ADN de Cadena Simple/química , Electroquímica , Electrodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...