Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Cell Infect Microbiol ; 13: 1091083, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37475958

RESUMEN

Background: Disordered gut microbiota (GM) structure and function may contribute to osteoporosis (OP). This study explores how traditional Chinese medicine (TCM) intervention affects the structure and function of the GM in patients with OP. Method: In a 3-month clinical study, 43 patients were randomly divided into two groups receiving conventional treatment and combined TCM (Yigu decoction, YGD) treatment. The correlation between the intestinal flora and its metabolites was analyzed using 16S rDNA and untargeted metabolomics and the combination of the two. Results: After three months of treatment, patients in the treatment group had better bone mineral density (BMD) than those in the control group (P < 0.05). Patients in the treatment group had obvious abundance changes in GM microbes, such as Bacteroides, Escherichia-Shigella, Faecalibacterium, Megamonas, Blautia, Klebsiella, Romboutsia, Akkermansia, and Prevotella_9. The functional changes observed in the GM mainly involved changes in metabolic function, genetic information processing and cellular processes. The metabolites for which major changes were observed were capsazepine, Phe-Tyr, dichlorprop, D-pyroglutamic acid and tamsulosin. These metabolites may act through metabolic pathways, the citrate cycle (TCA cycle) and beta alanine metabolism. Combined analysis showed that the main acting metabolites were dichlorprop, capsazepine, D-pyroglutamic acid and tamsulosin. Conclusion: This study showed that TCM influenced the structure and function of the GM in patients with OP, which may be one mechanism by which TCM promotes the rehabilitation of patients with OP through the GM.


Asunto(s)
Microbioma Gastrointestinal , Humanos , Ácido Pirrolidona Carboxílico , Tamsulosina , ARN Ribosómico 16S/genética
2.
BMC Med Imaging ; 21(1): 132, 2021 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-34503482

RESUMEN

BACKGROUND: Simultaneous multislice diffusion-weighted imaging (SMS-DWI) has been used to reduce image acquisition time. The purpose of this study was to investigate the feasibility of diffusion kurtosis imaging (DKI) based on the SMS technique in the liver and the influence of this method compared with that of conventional DWI sequences on image quality and DKI-derived quantitative parameters. METHODS: Forty volunteers underwent SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI, SMS3-DWI) and conventional DWI (C-DWI) of the liver with three b-values (50, 800, 2000 s/mm2) in a 3T system. Qualitative image quality parameters and quantitative measurements of the signal-to-noise ratio (SNR), mean kurtosis (MK), mean apparent diffusivity (MD) and apparent diffusion coefficient (ADC) for the liver were compared between the three sequences. RESULTS: The scan times of C-DWI, SMS2-DWI, and SMS3-DWI were 4 min 11 s, 2 min 2 s, and 1 min 34 s, respectively. For all image quality parameters, there were no significant differences observed between C-DWI and SMS2-DWI (all p > 0.05) in the images with b-values of 800 and 2000 s/mm2. C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI (all p < 0.01) in the images with b-values of 2000 s/mm2. In the images with b-values of 800 s/mm2, C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI for artefacts and overall image quality (all p < 0.01), and C-DWI exhibited better scores than SMS3-DWI for the visibility of intrahepatic vessels (p < 0.001). There were no significant differences in the sharpness of the right lobe edge (p = 0.144), conspicuity of the left lobe (p = 0.370) or visibility of intrahepatic vessels (p = 0.109) between SMS2-DWI and SMS3-DWI. There were no significant differences in the sharpness of the right lobe edge (p = 0.066) or conspicuity of the left lobe (p = 0.131) between C-DWI and SMS3-DWI. For the b-value of 800 s/mm2, there were no statistically significant differences between SMS2-DWI and C-DWI (p = 1.000) or between SMS2-DWI and SMS3-DWI (p = 0.059), whereas SMS3-DWI had a significantly lower SNR than C-DWI (p = 0.024). For the DKI-derived parameters (MK and MD) and ADC values, there were no significant differences between the three sequences (MK, p = 0.606; MD, p = 0.831; ADC, p = 0.264). CONCLUSIONS: SMS-DWI with an acceleration factor of 2 is feasible for the liver, resulting in considerable reductions in scan time while maintaining similar image quality, comparable DKI parameters and ADC values compared with those of C-DWI.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Hígado/diagnóstico por imagen , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido , Estadística como Asunto
3.
J Comput Assist Tomogr ; 45(4): 507-515, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34270482

RESUMEN

OBJECTIVE: To investigate the feasibility of quantitative intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) analyses in the upper abdominal organs by simultaneous multislice diffusion-weighted imaging (SMS-DWI). SUBJECTS AND METHODS: In this prospective study, a total of 32 participants underwent conventional DWI (C-DWI) and SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) in the upper abdomen with multiple b-values (0, 10, 20, 50, 80, 100, 150, 200, 500, 800, 1000, 1500, and 2000 seconds/mm2) on a 3 T system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany). Image quality and quantitatively measurements of apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), mean kurtosis (MK), and mean apparent diffusivity (MD) for the liver, pancreas, kidney cortex and medulla, spleen, and erector spine muscle were compared between the 3 sequences. RESULTS: The acquisition times for C-DWI, SMS2-DWI, and SMS3-DWI were 10 minutes 57 seconds, 5 minutes 9 seconds, and 3 minutes 54 seconds. For image quality parameters, C-DWI and SMS2-DWI yielded better results than SMS3-DWI (P < 0.05). SMS2-DWI had equivalent IVIM and DKI parameters compared with that of C-DWI (P > 0.05). No statistically significant differences in the ADC, D, f, and MD values between the 3 sequences (P > 0.05) were observed. The D* and MK values of the liver (P = 0.005 and P = 0.012) and pancreas (P = 0.019) between SMS3-DWI and C-DWI were significantly different. CONCLUSIONS: SMS2-DWI can substantially reduce the scan time while maintaining equivalent IVIM and DKI parameters in the abdominal organs compared with C-DWI.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Riñón/diagnóstico por imagen , Hígado/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Bazo/diagnóstico por imagen , Abdomen/diagnóstico por imagen , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Tiempo , Imagen de Cuerpo Entero/métodos , Adulto Joven
4.
Medicine (Baltimore) ; 97(4): e9666, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29369183

RESUMEN

We explored the utility of time-resolved angiography with interleaved stochastic trajectories dynamic contrast-enhanced magnetic resonance imaging (TWIST DCE-MRI), readout segmentation of long variable echo-trains diffusion-weighted magnetic resonance imaging- diffusion-weighted magnetic resonance imaging (RESOLVE-DWI), and echo-planar imaging- diffusion-weighted magnetic resonance imaging (EPI-DWI) for distinguishing between malignant and benign breast lesions.This retrospective analysis included female patients with breast lesions seen at a single center in China between January 2016 and April 2016. Patients were allocated to a benign or malignant group based on pathologic diagnosis. All patients received routine MRI, RESOLVE-DWI, EPI-DWI, and TWIST DCE-T1WI. Variables measured included quantitative parameters (K, Kep, and Ve), semiquantitative parameters (rate of contrast enhancement for contrast agent inflow [W-in], rate of contrast decay for contrast agent outflow [W-out], and time-to-peak enhancement after contrast agent injection [TTP]) and apparent diffusion coefficient (ADC) values for RESOLVE-DWI (ADCr) and EPI-DWI (ADCe). Receiver-operating characteristic (ROC) curve analysis was used to evaluate the diagnostic utility of each parameter for differentiating malignant from benign breast lesions.A total of 87 patients were included (benign, n = 20; malignant, n = 67). Compared with the benign group, the malignant group had significantly higher K, Kep and W-in and significantly lower W-out, TTP, ADCe, and ADCr (all P < .05); Ve was not significantly different between groups. RESOLVE-DWI was superior to conventional EPI-DWI at illustrating lesion boundary and morphology, while ADCr was significantly lower than ADCe in all patients. Kep, W-out, ADCr, and ADCe showed the highest diagnostic efficiency (based on AUC value) for differentiating between benign and malignant lesions. Combining 3 parameters (Kep, W-out, and ADCr) had a higher diagnostic efficiency (AUC, 0.965) than any individual parameter and distinguished between benign and malignant lesions with high sensitivity (91.0%), specificity (95.0%), and accuracy (91.9%).An index combining Kep, W-out, and ADCr could potentially be used for the differential diagnosis of breast lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , China , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA