Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Anal Toxicol ; 46(8): 918-924, 2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-35953454

RESUMEN

Although kombucha is a popular fermented beverage, the presence of alcohol markers has not been well studied despite being potential indicators of unintentional impairment. Ethyl glucuronide (EtG) and ethyl sulfate (EtS) were measured in oral fluid and urine collected after consumption of regular or hard kombucha. Participants drank within 20 min and provided all urine voids for 12 h, the first urine voids on days 2 and 3 and oral fluid specimens at fixed time points for 48 h. Screening employed liquid chromatography-tandem mass spectrometry (LC-MS-MS; EtS, 25 ng/mL cutoff [oral]; 100 ng/mL cutoff [urine]; EtG, 500 ng/mL cutoff [urine] and immunoassay (IA; EtG, 500 ng/mL cutoff [urine]). After consuming regular kombucha (n = 12 participants), EtS was not detected in oral fluid but both markers were detected by LC-MS-MS in urine specimens within the first five voids from 83% of participants with median (range) concentrations of 240 (100-3,700) ng/mL for EtS and 830 (530-2,200) ng/mL for EtG. Neither marker was positive by IA nor LC-MS-MS after day 1. After consuming hard kombucha (n = 7 participants), 2 (2.8%) of the 70 collected oral fluid specimens tested positive for EtS 3 h after consumption; however, 21 (30%) had EtS levels above the limit of detection (LOD, 10 ng/mL) after 0.5-8 h. Both markers were detected in urine specimens from all participants with median (range) concentrations of 3,381 (559-70,250) ng/mL for EtS and 763 (104-12,864) ng/mL For EtG. Urine specimens were negative for EtG and EtS by the end of the 48-hour study.


Asunto(s)
Glucuronatos , Ésteres del Ácido Sulfúrico , Consumo de Bebidas Alcohólicas/orina , Biomarcadores/orina , Etanol/orina , Glucuronatos/orina , Humanos , Ésteres del Ácido Sulfúrico/orina
2.
Forensic Sci Int ; 329: 111052, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34688186

RESUMEN

With tightening enforcement and restrictions amid the opioid epidemic, poppy seed tea is consumed as an alternative to mitigate the withdrawal symptoms or as a home remedy to relieve pain and stress. Previously published studies suggested the potential danger of consuming tea brewed with a moderate to a large amount of poppy seed. In this study, the effects of small quantity and repeat brewing on opiate concentrations were evaluated. A dispersive-micro solid phase extraction facilitated by magnetic carbon nanotubes (Mag-CNTs/d-µSPE) was developed, optimized, successfully validated, and applied to ten poppy seed tea samples using gas chromatography-mass spectrometry (GC-MS) analysis. A total of ten poppy seed samples were evaluated in this work. Two grams of bulk poppy seeds were brewed with 6 mL of heated and acidified DI water three times. The brewed tea samples were subjected to the validated Mag-CNTs/d-µSPE/GC-MS analysis. The total mean opiate concentrations obtained from three brews were 1.1-1926, 20.2-311, and 9.0-100 mg/kg for morphine, codeine, and thebaine, respectively. The total opiate yields obtained from the small quantity brewing, i.e., 6 g seed in 18 mL tea, in this study may provide minimal analgesic and euphoric effects. Over 80% of the total opiate yield was extracted in the first brew with acidified deionized water from the 10 min brewing period, and opiate yields from the second and third brew were minimal. However, potential overdose could occur for some tea samples when scaled up to the starter quantity of seed suggested for new users.


Asunto(s)
Nanotubos de Carbono , Papaver , Analgésicos Opioides , Codeína/análisis , Cromatografía de Gases y Espectrometría de Masas , Fenómenos Magnéticos , Morfina/análisis , Extracción en Fase Sólida , , Tebaína , Agua
3.
J Forensic Sci ; 66(6): 2201-2207, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34195997

RESUMEN

In this work, two gun barrels were 3D-printed using a metal alloy material from the same 3D digital model created in silico. After assembling the barrels in a reference Colt 45 Auto semi-automatic pistol, a total of 100 rounds of ammunition were successfully test-fired through each barrel. Heavy and gross striations were observed on all fired bullets. The striations on bullets discharged from the corresponding 3D-printed gun barrel were found to be identifiable. Moreover, bullets fired from one 3D-printed gun barrel were easily excluded from those fired from the other 3D-printed gun barrel by visual examination under a comparison microscope. The resulting unconventional striations that were observed were apparent to an experienced firearm and toolmark examiner. These features could provide valuable investigative leads related to the 3D printing process. Since 3D printing has become an option for firearm manufacturing, the forensic science community should establish a knowledge base associated with the toolmark features generated by the 3D-printed products.

4.
ACS Omega ; 5(42): 27171-27179, 2020 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-33134677

RESUMEN

This study reports the long-term storage stability of a formulation of the cyanide (CN) antidote dimethyl trisulfide (DMTS). The F3-formulated DMTS was stored in glass ampules at 4, 22, and 37 °C. Over a period of one year, nine ampules (n = 3 at each temperature) were analyzed by high-performance liquid chromatography (HPLC)-UV/vis at daily time intervals in the first week, weekly time intervals in the first month, and monthly thereafter for a period of one year to determine the DMTS content. No measurable loss of DMTS was found at 4 and 22 °C, and good stability was noted up to five months for samples stored at 37 °C. At 37 °C, a 10% (M/M) decrease of DMTS was discovered at the sixth month and only 30% (M/M) of DMTS remained by the end of the study; discoloration of the formulation and the growth of new peaks in the HPLC chromatogram were also observed. To identify the unknown peaks at 37 °C, controlled oxidation studies were performed on DMTS using two strong oxidizing agents: meta-chloroperoxybenzoic acid (mCPBA) and hydrogen peroxide (H2O2). Dimethyl tetrasulfide and dimethyl pentasulfide were observed as products using both of the oxidizing agents. Dimethyl disulfide was also observed as a product of degradation, which was further oxidized to S-methyl methanethiosulfonate only when mCPBA was used. HPLC-UV/vis and gas chromatography-mass spectrometry/solid phase microextraction analysis revealed good agreement between the degradation products of the stability study at 37 °C and those of disproportionation reactions. Furthermore, at 4 and 22 °C, chromatograms were remarkably stable over the one-year study period, indicating that the F3-formulated DMTS shows excellent long-term storage stability at T ≤ 22 °C.

5.
Artículo en Inglés | MEDLINE | ID: mdl-30738339

RESUMEN

2-aminothiazoline-4-carboxylic acid (ATCA) is a minor metabolite of cyanide and is suggested to be a promising biomarker for cyanide exposure due to its specificity to cyanide metabolism and its excellent short- and long-term stability during storage. In this study, magnetic carbon nanotubes, including magnetic multi-walled carbon nanotubes (Mag-MWCNT) and magnetic single-walled carbon nanotubes (Mag-SWCNT) were synthesized as a novel sorbent for dispersive micro solid phase extraction (d-µSPE) to extract ATCA from biological matrices. ATCA spiked deionized water samples with the addition of the isotopic internal standard (ATCA - 13C, 15N) were subjected to Mag-CNT/d-µSPE to confirm extraction efficiency of this new technique. The extracted ATCA was derivatized and quantitated using gas chromatography/mass spectrometry (GC/MS) analysis. The extraction parameters were optimized and a detection limits of 15 and 25 ng/mL were obtained for synthetic urine and bovine blood respectively with a linear dynamic range of 30-1000 ng/mL. The optimized Mag-CNT/d-µSPE method facilitated efficient extraction of ATCA using 2 mg of Mag-MWCNT with a 10-minute extraction time. The current assay was also found to be effective for the extraction of ATCA with average recoveries of 97.7 ±â€¯4.0% (n = 9) and 96.5 ±â€¯12.1% (n = 9) from synthetic urine and bovine blood respectively. The approach of using Mag-CNT to facilitate d-µSPE offered a novel alternative to extract ATCA from complex biological matrices.


Asunto(s)
Cianuros/metabolismo , Nanopartículas de Magnetita/química , Nanotubos de Carbono/química , Extracción en Fase Sólida/métodos , Tiazoles/aislamiento & purificación , Animales , Bovinos , Cromatografía de Gases y Espectrometría de Masas , Humanos , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Tiazoles/sangre , Tiazoles/metabolismo , Tiazoles/orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...