Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
World J Radiol ; 16(9): 429-438, 2024 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-39355390

RESUMEN

BACKGROUND: Global and regional cerebral blood flow (CBF) changes in patients with unilateral internal carotid artery occlusion (ICAO) are unclear when the dual post-labeling delays (PLD) arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique is used. Manual delineation of regions of interest for CBF measurement is time-consuming and laborious. AIM: To assess global and regional CBF changes in patients with unilateral ICAO with the ASL-MRI perfusion technique. METHODS: Twenty hospitalized patients with ICAO and sex- and age-matched controls were included in the study. Regional CBF was measured by Dr. Brain's ASL software. The present study evaluated differences in global, middle cerebral artery (MCA) territory, anterior cerebral artery territory, and Alberta Stroke Program Early Computed Tomography Score (ASPECTS) regions (including the caudate nucleus, lentiform nucleus, insula ribbon, internal capsule, and M1-M6) and brain lobes (including frontal, parietal, temporal, and insular lobes) between ICAO patients and controls at PLD 1.5 s and PLD 2.5 s. RESULTS: When comparing CBF between ICAO patients and controls, the global CBF in ICAO patients was lower at both PLD 1.5 s and PLD 2.5 s; the CBF on the occluded side was lower in 15 brain regions at PLD 1.5 s, and it was lower in 9 brain regions at PLD 2.5 s; the CBF in the contralateral hemisphere was lower in the caudate nucleus and internal capsule at PLD 1.5 s and in M6 at PLD 2.5 s. The global CBF in ICAO patients was lower at PLD 1.5 s than at PLD 2.5 s. The ipsilateral CBF at PLD 1.5 s was lower than that at PLD 2.5 s in 15 regions, whereas the contralateral CBF was lower at PLD 1.5 s than at PLD 2.5 s in 12 regions. The ipsilateral CBF was lower than the contralateral CBF in 15 regions at PLD 1.5 s, and in M6 at PLD 2.5 s. CONCLUSION: Unilateral ICAO results in hypoperfusion in the global and MCA territories, especially in the ASPECTS area. Dual PLD settings prove more suitable for accurate CBF quantification in ICAO.

2.
Anal Chem ; 2024 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-39358909

RESUMEN

Enhancing the electrochemiluminescence (ECL) properties of polycyclic aromatic hydrocarbons (PAHs) is a significant topic in the ECL field. Herein, we elaborately chose PAH derivative luminophore 1,3,6,8-tetrakis(p-benzoic acid)pyrene (H4TBAPy) as the organic ligand to synthesize a new Ru-complex-free ECL-active metal-organic framework Dy-TBAPy. Interestingly, Dy-TBAPy exhibited a more brilliant ECL emission and higher ECL efficiency than H4TBAPy aggregates. On the one hand, TBAPy luminophores were assembled into rigid MOF skeleton via coordination bonds, which not only enlarged the distance between pyrene cores to eliminate the aggregation-caused quenching (ACQ) effect but also obstructed the intramolecular motions of TBAPy to diminish the nonradiative relaxation, thus realizing a remarkable coordination-enhanced ECL. On the other hand, the ultrahigh porosity of Dy-TBAPy was beneficial to the diffusion of electrons, ions, and coreactant (S2O82-) in the skeleton, which efficiently boosted the excitation of interior TBAPy luminophores and led to a high utilization ratio of TBAPy, further improving ECL properties. More intriguingly, the ECL intensity of the Dy-TBAPy/S2O82- system was about 4.1, 87.0-fold higher than those of classic Ru(bpy)32+/TPrA and Ru(bpy)32+/S2O82- systems. Considering the aforementioned fabulous ECL performance, Dy-TBAPy was used as an ECL probe to construct a supersensitive ECL biosensor for microRNA-21 detection, which showed an ultralow detection limit of 7.55 aM. Overall, our study manifests that coordinatively assembling PAHs into MOFs is a simple and practicable way to improve ECL properties, which solves the ACQ issue of PAHs and proposes new ideas for developing highly efficient Ru-complex-free ECL materials, therefore providing promising opportunities to fabricate high-sensitivity ECL biosensors.

3.
Angew Chem Int Ed Engl ; : e202414064, 2024 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375853

RESUMEN

Granzyme A (GzmA) secreted by natural killer (NK) cells has garnered considerable interest as a biomarker to evaluate the efficacy of cancer immunotherapy. However, current methodologies to selectively monitor the spatial distribution of GzmA in cancer cells during NK cell-targeted therapy are extremely challenging, primarily due to the existence of diverse cell populations, the low levels of GzmA expression, and the limited availability of GzmA probes. Herein we develop a multi-modular, structurally-ordered DNA nanodevice for evaluating NK cell-mediated cancer immunotherapy (MODERN), that permits spatioselective imaging of GzmA in cancer cells through GzmA-induced apurinic/apyrimidinic endonuclease 1 (APE1) inactivation. The MODERN incorporates multiple functional modules, including an APE1-gated recognition module, a photo-activated amplification module, an aptamer-mediated tumor-target module, and a polycatenane DNA module, enabling improved sensitivity and specificity towards intracellular GzmA. The MODERN was activated (on) in cancer cells due to the overexpression of APE1, whereas it remained silent (off) in the NK-treated cancer cells owing to the GzmA-induced APE1 inactivation. Furthermore, we demonstrated that GzmA-induced APE1 inactivation blocks the cellular repair of target cells, resulting in efficient cell death. This MODERN that relies on the specific inactivation of APE1 by GzmA should be beneficial for evaluating the efficacy of cancer immunotherapy.

4.
Anal Chem ; 96(40): 15915-15923, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39324376

RESUMEN

Accurate monitoring of base excision repair (BER) activity in cancer cells is critical for advancing the comprehension of DNA repair processes, gaining insights into cancer development, and guiding treatment strategies. However, current assay techniques for assessing BER activity in cancer cells face challenges due to the heterogeneous origins and diversity of BER enzymes. In this work, we present a highly reliable triple loop-interlocked DNA codec (GATED) that enables precise assessment of BER activity in cancer cells through signal amplification mediated by multienzyme orthogonal activation. The GATED device features a dumbbell-shaped DNA probe to encode two BER enzymes for BER-related signal conversion as well as two bound circular DNA to decode the apurinic/apyrimidinic sites for apurinic/apyrimidinic endonuclease 1 (APE1)-mediated signal amplification. Importantly, GATED is orthogonally activated by multiple target BER enzymes (i.e., uracil DNA glycosylase, thymine DNA glycosylase, and APE1), resulting in a unified fluorescent signal that significantly improves the detection specificity and sensitivity to BER enzymes. Additionally, we demonstrate that the GATED has exceptional biostability within complex biological systems, where it was successfully employed to monitor BER activity in cancer cells with high specificity and enabled cell-based high-throughput screening for BER inhibitors. The GATED provides a much-needed tool for the real-time monitoring of BER activity and the screening of BER inhibitors in cancer cells, potentially advancing both the investigation and clinical application of BER biology.


Asunto(s)
Reparación del ADN , Humanos , ADN/química , ADN/metabolismo , Neoplasias/diagnóstico por imagen , ADN-(Sitio Apurínico o Apirimidínico) Liasa/metabolismo , Línea Celular Tumoral , Imagen Óptica , Reparación por Escisión
5.
J Colloid Interface Sci ; 674: 745-752, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38955006

RESUMEN

The exploration of novel electrochemiluminescence (ECL) luminophores with excellent ECL properties is a current research hotspot in the ECL field. Herein, a novel high-efficiency Ru-complex-free ECL emitter PyTS-Zr-BTB-MOL has been prepared by using porous ultrathin Zr-BTB metal-organic layer (MOL) as carrier to coordinatively graft the cheap and easily available polycyclic aromatic hydrocarbon (PAH) derivative luminophore PyTS whose ECL performance has never been investigated. Gratifyingly, the ECL intensity and efficiency of PyTS-Zr-BTB-MOL were markedly enhanced compared to both PyTS monomers and PyTS aggregates. The main reason was that the distance between pyrene rings was greatly expanded after the PyTS grafting on the Zr6 clusters of Zr-BTB-MOL, which overcame the aggregation-caused quenching (ACQ) effect of PyTS and thus enhanced the ECL emission. Meanwhile, the porous nanosheet structure of PyTS-Zr-BTB-MOL could distinctly increase the exposure of PyTS luminophores and shorten the diffusion paths of coreactants and electrons/ions, which effectively promoted the electrochemical excitation of more PyTS luminophores and thus achieved a further ECL enhancement. In light of the remarkable ECL property of PyTS-Zr-BTB-MOL, it was employed as an ECL indicator to build a novel high-sensitivity ECL biosensor for microRNA-21 determination, possessing a satisfactory response range (100 aM to 100 pM) and an ultralow detection limit (10.4 aM). Overall, this work demonstrated that using MOLs to coordinatively graft the PAH derivative luminophores to eliminate the ACQ effect and increase the utilization rate of the luminophores is a promising and efficient strategy to develop high-performance Ru-complex-free ECL materials for assembling ultrasensitive ECL biosensing platforms.


Asunto(s)
Técnicas Electroquímicas , Mediciones Luminiscentes , MicroARNs , Pirenos , Circonio , MicroARNs/análisis , Técnicas Electroquímicas/métodos , Mediciones Luminiscentes/métodos , Circonio/química , Pirenos/química , Humanos , Técnicas Biosensibles/métodos , Estructuras Metalorgánicas/química , Límite de Detección , Tamaño de la Partícula , Propiedades de Superficie , Sustancias Luminiscentes/química , Porosidad
6.
Anal Chim Acta ; 1295: 342321, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38355235

RESUMEN

Enhancing electrochemiluminescence (ECL) properties of luminophores is a hot direction in the current ECL field. Herein, we found that covalent rigidification of the aggregation-induced emission luminogens (AIEgens) TABE (TABE = tetra-(4-aldehyde-(1,1-biphenyl))ethylene) into covalent organic framework nanosheets (TABE-PZ-CON, PZ = piperazine) could result in stronger ECL emission than those of TABE aggregates and TABE monomers. We termed the interesting phenomenon "covalent rigidification-triggered electrochemiluminescence (CRT-ECL) enhancement". The superior ECL performance of TABE-PZ-CON not only because massive TABE luminogens were covalently assembled into the rigid TABE-PZ-CON network, which limited the intramolecular motions of TABE and hampered the radiationless transition, but also because the ultrathin porous TABE-PZ-CON significantly reduced the transportation distance of ions, electrons, and coreactants, which enabled the electrochemical excitation of more TABE luminogens and thus enhanced the ECL efficiency. Bearing in mind the exceptional ECL performance of TABE-PZ-CON, it was utilized as a high-efficient ECL indicator in combination with the DNA walker and duplex-specific nuclease-assisted target recycling amplification strategies to design an "off-on" ECL biosensor for the ultrasensitive assay of microRNA-21, exhibiting a favorable response range (100 aM-1 nM) with an ultralow detection limit of 17.9 aM. Overall, this work offers a valid way to inhibit the intramolecular motions of AIEgens for ECL enhancement, which gives a new vision for building high-performance AIEgen-based ECL materials, thus offering more chances for assembling hypersensitive ECL biosensors.


Asunto(s)
Técnicas Biosensibles , Estructuras Metalorgánicas , MicroARNs , Estructuras Metalorgánicas/química , Mediciones Luminiscentes , Técnicas Electroquímicas , Fotometría , MicroARNs/química , Límite de Detección
7.
Anal Chem ; 96(4): 1651-1658, 2024 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-38239061

RESUMEN

The development of a highly accurate electrochemiluminescence (ECL) signal switch to avoid nonspecific stimulus responses is currently a significant and challenging task. Here, we constructed a universal signal switch utilizing a luminophore-quencher pair of mesostructured silica xerogel-confined polymer and gold nanoparticles (Au NPs) that can accurately detect low-abundance epigenetic markers in complex sample systems. Notably, the ECL polymer encapsulated in mesostructured silica xerogel acts as a luminophore, which demonstrated a highly specific dependence on the Au NPs-mediated energy transfer quenching. To demonstrate the feasibility, we specifically labeled the 5-hydroxymethylcytosine (5hmC) site on the random sequence using a double-stranded (dsDNA) tag that was skillfully designed with the CRISPR/Cas12a activator and recombinant polymerase amplification (RPA) template. After amplification by RPA, a large amount of dsDNA tag was generated as the activator to initiate the trans-cleavage activity of CRISPR/Cas12a and subsequently activate the signal switch, allowing for precise quantification of 5hmC. The ECL signal switch improves the stability of the luminophore and prevents nonspecific stimulus responses, providing a new paradigm for constructing high-precision biosensors.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Polímeros , Oro , Dióxido de Silicio , Mediciones Luminiscentes , Técnicas Electroquímicas , Epigénesis Genética
8.
Anal Chem ; 96(5): 2117-2123, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-38268109

RESUMEN

Despite the progress that has been made in diverse DNA-based nanodevices to in situ monitor the activity of the DNA repair enzymes in living cells, the significance of improving both the sensitivity and specificity has remained largely neglected and understudied. Herein, we propose a regulatable DNA nanodevice to specifically monitor the activity of DNA repair enzymes for early evaluation of cancer mediated by genomic instability. Concretely, an AND logic gate-regulated DNAzyme nanoflower was rationally designed by the self-assembly of the DNA duplex modified with both apurinic/apyrimidinic (AP) site and methyl lesion site. The DNAzyme nanoflower could be reconfigured under the repair of AP sites and O6-methylguanine sites by apurinic/apyrimidinic endonuclease 1 (APE1) and O6-methylguanine methyltransferase (MGMT) to produce a fluorescent signal, realizing the sensitive monitoring of the activity of APE1 and MGMT. Compared to the free DNAzyme duplex, the fluorescent response of the DNAzyme nanoflower increased by 60%, due to the effective enrichment of the DNA probes by the nanoflower structure. More importantly, we have demonstrated that the dual-enzyme activated strategy allows imaging of specific cancer cells in the AND logic gate manner using MCF-7 as a cancer cell model, improving the specificity of cancer cell imaging. This AND logic gate-regulated multifunctional DNAzyme nanoflower provides a simple tool for simultaneously visualizing multiple DNA repair enzymes, holding great potential in early clinical diagnosis and drug discovery.


Asunto(s)
Reparación del ADN , ADN Catalítico , Daño del ADN , Enzimas Reparadoras del ADN/genética , ADN-(Sitio Apurínico o Apirimidínico) Liasa/metabolismo , ADN/química
9.
ACS Sens ; 9(1): 344-350, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-38198738

RESUMEN

DNA nanostructure provides powerful tools for DNA demethylase activity detection, but its stability has been significantly challenged. By virtue of circular DNA with resistance to exonuclease degradation, herein, the circular DNAzyme duplex with artificial methylated modification was constructed to identify the target and output the DNA activators to drive the CRISPR/Cas12a, constructing an "on-off-on" electrochemiluminescence (ECL) biosensor for monitoring the activity of the O6-methylguanine-DNA methyltransferase (MGMT). Specifically, the circular DNAzyme duplex consisted of the chimeric RNA-DNA substrate ring with double activator sequences and two single-stranded DNAzymes, whose catalytic domains were premodified with the methyl groups. When the MGMT was present, the methylated DNAzymes were repaired and restored the catalytic activity to cleave the chimeric RNA-DNA substrates, followed by the output of DNA activators to initiate the CRISPR/Cas12a. Subsequently, the ECL signals of silver nanoparticle-modified SnO2 nanospheres (Ag@SnO2) were recovered by releasing the ferrocene-labeled quenching probes (Fc-DNA) from the electrode surface because of the trans-cleavage activity of CRISPR/Cas12a, thus achieving the specific and sensitive ECL detection of MGMT from 2.5 × 10-4 to 2.5 × 102 ng/mL with a low limit (9.69 × 10-5 ng/mL). This strategy affords novel ideas and insights into research on how to project stable nucleic acid probes to detect DNA demethylases beyond traditional methods.


Asunto(s)
ADN Catalítico , Nanopartículas del Metal , ADN Catalítico/química , Sistemas CRISPR-Cas , Nanopartículas del Metal/química , Plata , ADN/química , ARN
10.
Anal Chem ; 95(37): 13897-13903, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37682117

RESUMEN

Despite the fact that electrochemiluminescent (ECL) performance of carbon dots (CDs) could be improved by modulating their surface defects, they are still restricted by inferior controllability and poor reproducibility. In this work, we disclosed a new approach for synthesizing luminescent groups rich in CDs (Lu-CDs) by engineering the luminol as molecular emission centers into the CDs, which exhibited an 80-fold stronger ECL intensity at an ECL onset potential of 0.6 V than the CDs without pre-implanted luminol. Different from the significant deviation between the ECL and fluorescence emission of other surface state-dominated CDs, the ECL emission of Lu-CDs was nearly consistent with its fluorescence emission at 465 nm, which was defined as the molecular emission dominated-ECL CDs herein. To prove this principle, the Lu-CDs were employed to construct an ECL biosensor for MCF-7 cell analysis based on the cell direct recognition and amplification strategy, which made the MCF-7 cells as nanomachines via specific binding with aptamer signal probes on the DNA triangular scaffold. The proposed biosensor displayed a wide detection range from 101 to 104 cell mL-1 and a low detection limit of 8.91 cells mL-1. Overall, this work not only presents a new strategy for preparing CDs with high controllability and excellent reproducibility but also provides a platform for tumor cell sensing.


Asunto(s)
Luminol , Neoplasias , Reproducibilidad de los Resultados , Ingeniería , Carbono , Comunicación Celular
11.
Biosens Bioelectron ; 238: 115589, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37591158

RESUMEN

Given the targeted binding ability and cleavage activity of the emerging CRISPR/Cas12a assay which transduces the target into its cleavage activity exhibited broadly prospective applications in integrated sensing and actuating system. Here, we elaborated a universal approach to quickly activate CRISPR/Cas12a for low-abundance biomarker detection based on the amplification strategy of a target-induced spherical nucleic acid enzyme (SNAzyme) network that could accelerate the output of activators. Specifically, multifunctional Y-shaped probes and hairpin probes (HPs, which contained the specific sequence of the activators of CRISPR/Cas12a and the substrate chain of DNAzyme) were rationally designed to construct SNAzyme. Target recognition induced disassembly of the Y-shaped probes, which released DNAzyme strands to active DNAzyme and accompanied by SNAzyme self-assembly into SNAzyme network. Interestingly, compared with randomly dispersed SNAzyme, the reaction kinetics of the SNAzyme network enhanced 1.6 times in response to Α-methyl acyl-CoA racemase (AMACR, a biomarker for prostate cancer), which was attributed to the promoted catalytic efficiency of DNAzyme by the confined SNAzyme network. Benefiting from these, the prepared biosensor based on electrochemiluminescence (ECL) platform by loading AuAg nanoclusters (AuAgNCs) into metal-organic framework-5 (MOF-5) exhibited satisfying detection performance for AMACR with a wide linear range (0.001 µg/mL to 100 µg/mL) and a low detection limit (1.0 × 10-4 µg/mL, which exhibited significant potential in clinical diagnoses.


Asunto(s)
Técnicas Biosensibles , ADN Catalítico , Masculino , Humanos , Bioensayo , Catálisis
12.
Biosens Bioelectron ; 240: 115640, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37651947

RESUMEN

Paraquat (PQ) is a typical biotoxic small molecule. Knowledge of how to directly introduce it into cyclic amplification rather than transform it into a secondary target is lacking in current analytical methods. Considering the urgent need for trace pesticide residue detection and the inherent defects of small molecule analysis, a CRISPR/Cas12a-driven small molecule-induced dual-cycle strategy was developed based on the immune competition method. The key to signal amplification is the mutual activation and acceleration between Cycle 1 triggered by the small molecule and Cycle 2 driven by CRISPR/Cas12a. Impressively, small molecules have been successfully incorporated into the dual-cycle strategy, which achieves a low detection limit (3.1 pg/mL) and a wide linear range (from 10 pg/mL to 50 µg/mL). Moreover, the designed biosensor was successfully employed to evaluate the PQ residual level in real samples and showed effective implementation for the bioanalysis of small molecule targets and pesticide residue-related food safety.


Asunto(s)
Técnicas Biosensibles , Residuos de Plaguicidas , Paraquat , Inocuidad de los Alimentos
13.
Anal Chem ; 95(25): 9598-9604, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37311025

RESUMEN

5-Methylcytosine (5mC) and 5-hydroxymethylcytosine (5hmC) are two of the most abundant epigenetic marks in mammalian genomes, and it has been proven that these dual epigenetic marks give a more accurate prediction of recurrence and survival in cancer than the individual mark. However, due to the similar structure and low expression of 5mC and 5hmC, it is challenging to distinguish and quantify the two methylation modifications. Herein, we employed the ten-eleven translocation family dioxygenases (TET) to convert 5mC to 5hmC via a specific labeling process, which realized the identification of the two marks based on a nanoconfined electrochemiluminescence (ECL) platform combined with the amplification strategy of a recombinase polymerase amplification (RPA)-assisted CRISPR/Cas13a system. Benefiting from the TET-mediated conversion strategy, a highly consistent labeling pathway was developed for identifying dual epigenetic marks on random sequence, which reduced the system error effectively. The ECL platform was established via preparing a carbonized polymer dot embedded SiO2 nanonetwork (CPDs@SiO2), which exhibited higher ECL efficiencies and more stable ECL performance compared to those of the scattered emitters due to the nanoconfinement-enhanced ECL effect. The proposed bioanalysis strategy could be employed for the identification and quantification of 5mC and 5hmC in the range from 100 aM to 100 pM, respectively, which provides a promising tool for early diagnosis of diseases associated with abnormal methylation.


Asunto(s)
5-Metilcitosina , Citosina , Animales , 5-Metilcitosina/metabolismo , Citosina/metabolismo , Secuencia de Bases , Dióxido de Silicio , Metilación de ADN , Mamíferos/metabolismo
14.
J Am Chem Soc ; 145(23): 12812-12822, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37249527

RESUMEN

Life molecules' distributions in live systems construct the complex dynamic reaction networks, whereas it is still challenging to demonstrate the dynamic distributions of biomolecules in live systems. Herein, we proposed a dynamic analysis strategy via sequence-structure bispecific RNA with state-adjustable molecules to monitor the dynamic concentration and spatiotemporal localization of these biomolecules in live cells based on the new insight of fluorescent RNA (FLRNA) interactions and their mechanism of fluorescence enhancement. Typically, computer-based nucleic acid-molecular docking simulation and molecular theoretical calculation have been proposed to provide a simple and straightforward method for guiding the custom-design of FLRNA. Impressively, a novel FLRNA with sequence and structure bispecific RNA named as a structure-switching aptamer (SSA) was introduced to monitor the real-time concentration and spatiotemporal localization of biomolecules, contributing to a deeper insight of the dynamic monitoring and visualization of biomolecules in live systems.


Asunto(s)
Colorantes Fluorescentes , ARN , ARN/química , Simulación del Acoplamiento Molecular , Colorantes Fluorescentes/química
15.
Biosens Bioelectron ; 227: 115157, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36841115

RESUMEN

Improving the electrochemiluminescence (ECL) performance of luminophores is an ongoing research hotspot in the ECL realm. Herein, a high-performance metal-organic framework (MOF)-based ECL material (Ru@Ni3(HITP)2, HITP = 2,3,6,7,10,11-hexaiminotriphenylene) with conductivity- and confinement-enhanced ECL was successfully constructed by using conductive MOF Ni3(HITP)2 as the carrier to graft Ru(bpydc)34- (H2bpydc = 2,2'-bipyridine-4,4'-dicarboxylic acid) into the channels of Ni3(HITP)2. Compared to Ru@Cu3(HITP)2 and Ru@Co3(HITP)2 with relatively low conductivity, the ECL intensity of Ru@Ni3(HITP)2 was prominently increased about 6.76 times and 18.8 times, respectively, which demonstrated that the increase in conductivity induced the ECL enhancement of the MOF-based ECL materials. What's more, the hydrophobic and porous Ni3(HITP)2 can not only effectively enrich the lipophilic tripropylamine (TPrA) coreactants in its channels to enhance the electrochemical oxidation efficiency of TPrA, but also provide a conductive reaction micro-environment to boost the ECL reaction between Ru(bpydc)33- intermediates and TPrA• in confined spaces, thus realizing a remarkable confinement-enhanced ECL. Considering the excellent ECL performance of Ru@Ni3(HITP)2, an ultrasensitive ECL biosensor was prepared based on the Ru@Ni3(HITP)2 ECL indicator combining an exonuclease I-aided target cycling amplification strategy for thrombin determination. The constructed ECL biosensor showcased a wide linear range from 1 fM to 1 nM with a low detection limit of 0.62 fM. Overall, the conductivity- and confinement-enhanced ECL based on Ru@Ni3(HITP)2 provided effective and feasible strategies to enhance ECL performance, which paved a promising avenue for exploring high-efficient MOF-based ECL materials and thus broadened the application scope of conductive MOFs.


Asunto(s)
Técnicas Biosensibles , Estructuras Metalorgánicas , Rutenio , Técnicas Electroquímicas , Mediciones Luminiscentes , Rutenio/química , Estructuras Metalorgánicas/química
16.
Biosens Bioelectron ; 220: 114886, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36379174

RESUMEN

Ultrathin metal-organic layers (MOLs) have attracted substantial attention in fabricating highly efficient electrochemiluminescence (ECL) materials due to their porous structure, small diffusion blockage, and short electron/ion-diffusion pathway, yet MOLs suffer from the inherent poor electrical conductivity that astricted the electrochemical activation, resulting in the unsatisfactory utilization ratio of ECL emitters. Herein, to address this limitation, we in situ hybridized Zr-based ultrathin MOL (Zr-TCBPE-MOL, H4TCBPE = 1,1,2,2-tetra(4-carboxylbiphenyl)ethylene) with the highly conductive Ti3C2Tx MXene nanosheet to obtain a unique 2D-2D hybrid nanocomposite (Zr-TCBPE-MOL/MXene). Benefiting from the above-mentioned attractive virtues of ultrathin MOLs and the superior conductivity of Ti3C2Tx MXene nanosheet, the resulting Zr-TCBPE-MOL/MXene nanocomposite permitted fast electron/ion transport across the whole framework of Zr-TCBPE-MOL/MXene, which efficiently boosted the electrochemical activation of TCBPE luminophores and thus improved the utilization ratio of luminophores to realize a remarkable ECL emission. Gratifyingly, we found that the ECL signal of Zr-TCBPE-MOL/MXene nanocomposite was greatly enhanced by around 4.1 times in contrast to that of pure Zr-TCBPE-MOL. On basis of the prominent ECL performance of Zr-TCBPE-MOL/MXene nanocomposite, a novel "off-on" ECL biosensor was proposed to sensitively analyze microRNA-141, which possessed a wide response range (100 aM-1 nM) and a low detection limit of 16.2 aM. Overall, this work puts forward a rational strategy to construct high-performance ECL materials and sheds new light on developing sensitive ECL sensing platforms.


Asunto(s)
Técnicas Biosensibles , Electrones , Titanio , Transporte Iónico , Metales , Técnicas Electroquímicas , Mediciones Luminiscentes
17.
Anal Chem ; 94(47): 16402-16410, 2022 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-36383421

RESUMEN

It is universally recognized that the quantification of DNA hydroxymethylation at random gene sequences still remains challenging. Herein, the highly sensitive identifying strategy of 5-hydroxymethylcytosine (5-hmC) without sequence specificity was achieved with a novel electrochemiluminescence (ECL) biosensor, which deftly integrated metal-organic framework (MOF)-derived amorphous MnOxSy nanoflowers (MnOxSy NFs) as a bifunctional co-reaction accelerator and cross-shaped DNA tracks as a well-regulated signal switch. Specifically, the target recognition process of 5-hmC was performed through specific chemical modification, where the hydroxymethyl sites were first aminated and then labeled with a 5'-carboxyl-functioned DNA walker, thus forming the target labeled DNA walker (5-ghmC-walker). Subsequently, the cross-shaped DNA tracks were ingeniously designed to endow the 5-ghmC-walker with continuous mechanical motion due to the long periodic linear alignment structure and well-regulated highly ordered interfaces. Furthermore, as a bifunctional co-reaction accelerator synthesized by in situ Mn-MOF template-sacrificing strategy, the MnOxSy NFs could promote the reduction of both dissolved O2 and S2O82-, remarkably boosting the ECL intensity of a peroxydisulfate (S2O82-) solution by 5.2 times compared to the pure S2O82- solution. Benefiting from specific target recognition and a dual-pathway strategy for boosting ECL, the proposed ECL platform can quantify 5-hmC with a wide linear range of 1 fM-1 nM and a low detection limit of 0.29 fM. This simple, highly sensitive strategy without sequence specificity provides a powerful platform for 5-hmC detection in the epigenetic study and disease pathogenesis.


Asunto(s)
Técnicas Biosensibles , Estructuras Metalorgánicas , Técnicas Electroquímicas , 5-Metilcitosina , ADN , Mediciones Luminiscentes , Límite de Detección
18.
Anal Chem ; 94(45): 15832-15838, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36325718

RESUMEN

Exploring new electrochemiluminescence (ECL) luminophores with strong ECL emission is highly desirable for developing ultrasensitive ECL sensors. Herein, a pyrene-based hydrogen-bonded organic framework (Py-HOF) featuring prominent ECL performance was prepared by utilizing 1,3,6,8-tetrakis(p-benzoic acid) pyrene (H4TBAPy) with an aggregation-induced enhanced emission (AIEE) property as a building block, exhibiting a stronger ECL emission than those of H4TBAPy monomers, H4TBAPy aggregates, the low-porosity Py-HOF-210 °C and Py-HOF-180 °C. We have coined the term "the porosity- and aggregation-induced enhanced ECL (PAIE-ECL)" for this intriguing phenomenon. The Py-HOF displayed superb and stable ECL intensity, not only because the luminophore H4TBAPy was assembled into the Py-HOF via four pairs of O-H···O hydrogen bonds, which constrained the intramolecular movements to reduce nonradiative transition, but also because the H4TBAPy in Py-HOF was stacked in a slipped face-to-face mode to form J-aggregates that benefited the ECL enhancement. Furthermore, the high porosity of Py-HOF allowed the enrichment of coreactants and facilitated the migration of ions, electrons, and coreactants, which made it possible for the inner and outer H4TBAPy to be electrochemically excited. Considering the remarkable ECL performance, Py-HOF was first employed as an ECL probe combined with a 3D DNA nanomachine amplification strategy to assemble a hypersensitive "on-off" ECL sensor for the microRNA-141 assay, presenting a satisfactory linear range (100 aM to 1 nM) with a detection limit of 14.4 aM. The PAIE-ECL manifested by Py-HOF provided a bright avenue for the design and synthesis of outstanding HOF-based ECL materials and offered new opportunities for the development of ECL biosensors with excellent sensitivity.


Asunto(s)
Técnicas Biosensibles , MicroARNs , Técnicas Electroquímicas , Mediciones Luminiscentes , MicroARNs/química , Límite de Detección , Porosidad , Enlace de Hidrógeno , Pirenos , Hidrógeno
19.
ACS Sens ; 7(10): 3208-3215, 2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36239972

RESUMEN

Herein, an exogenous luminophore-free and disposable electrochemiluminescence (ECL) biosensor was established for rapid response of acute myocardial infarction (AMI) using programmable Y-shaped probes (Y-probes) with proximity bivalent recognition. Specifically, the indium tin oxide thin film coated glass electrode (ITO) was modified with urchin-like porous TiO2 microspheres (pTiO2 MSs), which could achieve strong and stable ECL in S2O82- solution due to the dual promoting effect of the coreaction accelerator pTiO2 MSs, exhibiting 2.7-fold higher ECL intensity in comparison with that of bare ITO. Moreover, the Y-probes as bivalent recognition elements containing two kinds of cardiac troponin I (cTnI, a biomarker of AMI) aptamers and a linker labeled with ferrocene (L-Fc) were designed to export a "signal off" mode. When the target cTnI was in the proximity of the Y-probes, the L-Fc was separated from the electrode surface due to the proximity recognition of cTnI and its aptamers, achieving the highly effective recovery of ECL, which allowed for a much more rapid detection of cTnI than the sandwich-type immunoassay. As a proof of concept, an exogenous luminophore-free and disposable ECL platform for rapid and sensitive monitoring of cTnI was obtained and displayed a desired linear range from 100 fg mL-1 to 100 ng mL-1 with a limit of detection (LOD) of 30.1 fg mL-1, which can be ingeniously expanded as a portable home tester with ECL biosensors developments.


Asunto(s)
Técnicas Biosensibles , Infarto del Miocardio , Humanos , Técnicas Electroquímicas , Mediciones Luminiscentes , Límite de Detección , Troponina I , Infarto del Miocardio/diagnóstico
20.
Adv Mater ; 34(49): e2206524, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36127132

RESUMEN

Deuterium water (D2 O) is a strategic material that is widely used in and scientific research and has applications in fields such as nuclear energy generation. However, its content in natural water is extremely low. Therefore, the development of a room-temperature technology for achieving simple, efficient, and low-cost separation of D2 O from natural water is challenging. In this study, porous graphene (PG) nanosheets with "crater-like" pores are sandwiched between two layers of graphene oxide (GO) membranes to prepare a GO/PG/GO membrane with a macroscopic heterostructure, which can be used to separate D2 O and H2 O by pressure-driven filtration. At 25 °C, the rejection rate of D2 O is ≈97%, the selectivity of H2 O/D2 O is ≈35.2, and the excellent performance can be attributed to the difference of transmembrane resistance and flow state of H2 O and D2 O in the confinement state. In addition, the D2 O concentration in natural water is successfully enriched from 0.013% to 0.059% using only one stage, and the membrane exhibits excellent structural and cycling stability. Therefore, this method does not require ultralow temperatures, high energy supplies, complex separation equipment, or the introduction of toxic chemicals. Thus, it can be directly applied to the large-scale industrial production and removal of D2 O.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...