Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Methods Mol Biol ; 2668: 99-108, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37140792

RESUMEN

Immunoaffinity chromatography (IAC) with selective antibodies immobilized on polymeric monolithic disk columns enables selective isolation of biomacromolecules from human plasma, while asymmetrical flow field-flow fractionation (AsFlFFF or AF4) can be used for further fractionation of relevant subpopulations of biomacromolecules (e.g., small dense low-density lipoproteins, exomeres, and exosomes) from the isolates. Here we describe how the isolation and fractionation of subpopulations of extracellular vesicles can be achieved without the presence of lipoproteins using on-line coupled IAC-AsFlFFF. With the developed methodology, it is possible to have fast, reliable, and reproducible automated isolation and fractionation of challenging biomacromolecules from human plasma with a high purity and high yields of subpopulations.


Asunto(s)
Exosomas , Vesículas Extracelulares , Fraccionamiento de Campo-Flujo , Humanos , Exosomas/química , Lipoproteínas/análisis , Lipoproteínas LDL , Fraccionamiento de Campo-Flujo/métodos
2.
Anal Biochem ; 647: 114672, 2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35395223

RESUMEN

Raman spectroscopy together with comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS) was employed to characterize exomere- (<50 nm) and exosome-sized (50-80 nm) EVs isolated from human plasma by the novel on-line immunoaffinity chromatography - asymmetric flow field-flow fractionation method. CD9+, CD63+, and CD81+ EVs were selected to represent general EV subpopulations secreted into plasma, while CD61+ EVs represented the specific EV subset derived from platelets. Raman spectroscopy could distinguish EVs from non-EV particles, including apolipoprotein B-100-containing lipoproteins, signifying its potential in EV purity assessment. Moreover, platelet-derived (CD61+) EVs of both exomere and exosome sizes were discriminated from other EV subpopulations due to different biochemical compositions. Further investigations demonstrated composition differences between exomere- and exosome-sized EVs, confirming the applicability of Raman spectroscopy in distinguishing EVs, not only from different origins but also sizes. In addition, fatty acids that act as building blocks for lipids and membranes in EVs were studied by GCxGC-TOF-MS. The results achieved highlighted differences in EV fatty acid compositions in both esterified (membrane lipids) and non-esterified (free fatty acids) fractions, indicating possible differences in membrane structures, biological functions, and roles in cell-to-cell communications of EV subpopulations.


Asunto(s)
Exosomas , Vesículas Extracelulares , Fraccionamiento de Campo-Flujo , Vesículas Extracelulares/química , Cromatografía de Gases y Espectrometría de Masas , Humanos , Espectrometría Raman
3.
Biosens Bioelectron ; 206: 114151, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35259607

RESUMEN

Continuous flow quartz crystal microbalance (QCM) was utilized to study binding kinetics between EV subpopulations (exomere- and exosome-sized EVs) and four affinity ligands: monoclonal antibodies against tetraspanins (anti-CD9, anti-CD63, and anti-CD81) and recombinant intercellular adhesion molecule-1 (ICAM-1) or CD54 protein). High purity CD9+, CD63+, and CD81+ EV subpopulations of <50 nm exomeres and 50-80 nm exosomes were isolated and fractionated using our recently developed on-line coupled immunoaffinity chromatography - asymmetric flow field-flow fractionation system. Adaptive Interaction Distribution Algorithm (AIDA), specifically designed for the analysis of complex biological interactions, was used with a four-step procedure for reliable estimation of the degree of heterogeneity in rate constant distributions. Interactions between exomere-sized EVs and anti-tetraspanin antibodies demonstrated two interaction sites with comparable binding kinetics and estimated dissociation constants Kd ranging from nM to fM. Exomeres exhibited slightly higher affinity compared to exosomes. The highest affinity with anti-tetraspanin antibodies was achieved with CD63+ EVs. The interaction of EV subpopulations with ICAM-1 involved in cell internalization of EVs was also investigated. EV - ICAM-1 interaction was also of high affinity (nM to pM range) with overall lower affinity compared to the interactions of anti-tetraspanin antibodies and EVs. Our findings proved that QCM is a valuable label-free tool for kinetic studies with limited sample concentration, and that advanced algorithms, such as AIDA, are crucial for proper determination of kinetic heterogeneity. To the best of our knowledge, this is the first kinetic study on the interaction between plasma-derived EV subpopulations and anti-tetraspanin antibodies and ICAM-1.


Asunto(s)
Técnicas Biosensibles , Vesículas Extracelulares , Vesículas Extracelulares/química , Molécula 1 de Adhesión Intercelular/análisis , Molécula 1 de Adhesión Intercelular/metabolismo , Cinética , Tecnicas de Microbalanza del Cristal de Cuarzo , Tetraspaninas/análisis , Tetraspaninas/metabolismo
4.
J Chromatogr A ; 1636: 461773, 2021 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-33316564

RESUMEN

Extracellular vesicles (EVs) are heterogenous membrane-bound vesicles released from various origins. EVs play a crucial role in cellular communication and mediate several physiological and pathological processes, highlighting their potential therapeutic and diagnostic applications. Due to the rapid increase in interests and needs to elucidate EV properties and functions, numerous isolation and separation approaches for EVs have been developed to overcome limitations of conventional techniques, such as ultracentrifugation. This review focuses on recently emerging and modern EV isolation and separation techniques, including size-, charge-, and affinity-based techniques while excluding ultracentrifugation and precipitation-based techniques due to their multiple limitations. The advantages and drawbacks of each technique are discussed together with insights into their applications. Emerging approaches all share similar features in terms of being time-effective, easy-to-operate, and capable of providing EVs with suitable and desirable purity and integrity for applications of interest. Combination and hyphenation of techniques have been used for EV isolation and separation to yield EVs with the best quality. The most recent development using an automated on-line system including selective affinity-based trapping unit and asymmetrical flow field-flow fractionation allows reliable isolation and fractionation of EV subpopulations from human plasma.


Asunto(s)
Vesículas Extracelulares/química , Cromatografía de Afinidad , Cromatografía en Gel , Cromatografía por Intercambio Iónico , Electroforesis , Fraccionamiento de Campo-Flujo , Humanos , Ultracentrifugación
5.
Anal Chem ; 92(19): 13058-13065, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-32893620

RESUMEN

An automated on-line isolation and fractionation system including controlling software was developed for selected nanosized biomacromolecules from human plasma by on-line coupled immunoaffinity chromatography-asymmetric flow field-flow fractionation (IAC-AsFlFFF). The on-line system was versatile, only different monoclonal antibodies, anti-apolipoprotein B-100, anti-CD9, or anti-CD61, were immobilized on monolithic disk columns for isolation of lipoproteins and extracellular vesicles (EVs). The platelet-derived CD61-positive EVs and CD9-positive EVs, isolated by IAC, were further fractionated by AsFlFFF to their size-based subpopulations (e.g., exomeres and exosomes) for further analysis. Field-emission scanning electron microscopy elucidated the morphology of the subpopulations, and 20 free amino acids and glucose in EV subpopulations were identified and quantified in the ng/mL range using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The study revealed that there were significant differences between EV origin and size-based subpopulations. The on-line coupled IAC-AsFlFFF system was successfully programmed for reliable execution of 10 sequential isolation and fractionation cycles (37-80 min per cycle) with minimal operator involvement, minimal sample losses, and contamination. The relative standard deviations (RSD) between the cycles for human plasma samples were 0.84-6.6%.


Asunto(s)
Aminoácidos/sangre , Anticuerpos Monoclonales/sangre , Automatización , Cromatografía de Afinidad , Fraccionamiento de Campo-Flujo , Glucosa/análisis , Técnicas de Inmunoadsorción , Cromatografía Liquida , Humanos , Espectrometría de Masas en Tándem
6.
Sci Rep ; 9(1): 11235, 2019 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-31375727

RESUMEN

Low-density lipoprotein (LDL) is considered the major risk factor for the development of atherosclerotic cardiovascular diseases (ASCVDs). A novel and rapid method for the isolation of LDL from human plasma was developed utilising affinity chromatography with monolithic stationary supports. The isolation method consisted of two polymeric monolithic disk columns, one immobilized with chondroitin-6-sulfate (C6S) and the other with apolipoprotein B-100 monoclonal antibody (anti-apoB-100 mAb). The first disk with C6S was targeted to remove chylomicrons, very-low-density lipoprotein (VLDL) particles, and their remnants including intermediate-density lipoprotein (IDL) particles, thus allowing the remaining major lipoprotein species, i.e. LDL, lipoprotein(a) (Lp(a)), and high-density lipoprotein (HDL) to flow to the anti-apoB-100 disk. The second disk captured LDL particles via the anti-apoB-100 mAb attached on the disk surface in a highly specific manner, permitting the selective LDL isolation. The success of LDL isolation was confirmed by different techniques including quartz crystal microbalance. In addition, the method developed gave comparable results with ultracentrifugation, conventionally used as a standard method. The reliable results achieved together with a short isolation time (less than 30 min) suggest the method to be suitable for clinically relevant LDL functional assays.


Asunto(s)
Cromatografía de Afinidad/métodos , Lipoproteínas LDL/aislamiento & purificación , Anticuerpos Inmovilizados , Anticuerpos Monoclonales , Apolipoproteína B-100/inmunología , Sulfatos de Condroitina/química , Quilomicrones/aislamiento & purificación , Humanos , Lipoproteínas LDL/sangre , Factores de Tiempo
7.
Anal Chem ; 90(8): 5366-5374, 2018 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-29589451

RESUMEN

When using biosensors, analyte biomolecules of several different concentrations are percolated over a chip with immobilized ligand molecules that form complexes with analytes. However, in many cases of biological interest, e.g., in antibody interactions, complex formation steady-state is not reached. The data measured are so-called sensorgram, one for each analyte concentration, with total complex concentration vs time. Here we present a new four-step strategy for more reliable processing of this complex kinetic binding data and compare it with the standard global fitting procedure. In our strategy, we first calculate a dissociation graph to reveal if there are any heterogeneous interactions. Thereafter, a new numerical algorithm, AIDA, is used to get the number of different complex formation reactions for each analyte concentration level. This information is then used to estimate the corresponding complex formation rate constants by fitting to the measured sensorgram one by one. Finally, all estimated rate constants are plotted and clustered, where each cluster represents a complex formation. Synthetic and experimental data obtained from three different QCM biosensor experimental systems having fast (close to steady-state), moderate, and slow kinetics (far from steady-state) were evaluated using the four-step strategy and standard global fitting. The new strategy allowed us to more reliably estimate the number of different complex formations, especially for cases of complex and slow dissociation kinetics. Moreover, the new strategy proved to be more robust as it enables one to handle system drift, i.e., data from biosensor chips that deteriorate over time.


Asunto(s)
Algoritmos , Técnicas Biosensibles , Tecnicas de Microbalanza del Cristal de Cuarzo , Cinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA