Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Dent Sci ; 19(2): 1182-1189, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618102

RESUMEN

Background/purpose: Oral health is related to general health and a person's overall well-being. The aim of the present study was to explore the association between oral health status and bite force among young adults. Materials and methods: Maximum bite force (MBF) was measured using Dental Prescale II in conjunction with a pressure-sensitive film and bite force analyzer in 40 young adults aged 20 to 40. Supragingival dental plaque was collected and cultured. Plaque weight, pH, and colony counts were assessed. The decayed, missing, and filled teeth index (DMFT) and body mass index (BMI) were recorded. Results: Bite force was negatively correlated with the number of missing teeth and the sum of missing and filled teeth. When the filled-to-remaining-teeth ratio (F/R ratio) was less than 8%, the bite force was significantly higher compared to an F/R ratio of 8-25%. Additionally, the amount of total bacteria was positively correlated with total bite force, and the quantity of Streptococcus mutans (S. mutans) along with total bacteria was positively correlated with bite force in the molar region (∗P < 0.05). The molar region predominantly contributed to bite force. Conclusion: Elevated levels of cariogenic bacteria may increase the risk of tooth loss, subsequently leading to reduced bite force. This reduction in bite force can further impact the efficiency of chewing function and, consequently, the quality of life. An F/R ratio above 8% could be easily calculated clinically and could serve as a guide to identify patients, particularly young adults, at risk of reduced bite force.

2.
Front Bioeng Biotechnol ; 11: 1159639, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180046

RESUMEN

Introduction: To overcome the genuine bioinert properties of zirconia ceramic, functionalization of the surface with the bioactive protein fibronectin was conducted. Methods: Glow discharge plasma (GDP)-Argon was first used to clean the zirconia surface. Then allylamine was treated at three different powers of 50 W, 75 W, and 85 W and immersed into 2 different fibronectin concentrations (5 µg/ml and 10 µg/ml). Results and Discussion: After surface treatment, irregularly folded protein-like substances were attached on the fibronectin coated disks, and a granular pattern was observed for allylamine grafted samples. Infrared spectroscopy detected C-O, N-O, N-H, C-H, and O-H functional groups for fibronectin treated samples. Surface roughness rose and hydrophilicity improved after the surface modification, with MTT assay showing the highest level of cell viability for the A50F10 group. Cell differentiation markers also showed that fibronectin grafted disks with A50F10 and A85F10 were the most active, which in turn encouraged late-stage mineralization activity on 21d. Up-regulation of osteogenic related mRNA expression from 1d to 10d can be observed in RT-qPCR data for ALP, OC, DLX5, SP7, OPG and RANK biomarkers. These physical and biological properties clearly indicate that an allylamine and fibronectin composite grafted surface significantly stimulated the bioactivity of osteoblast-like cells, and can be utilized for future dental implant applications.

3.
J Pers Med ; 12(8)2022 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-36013175

RESUMEN

Preserving the marginal bone level (MBL) is essential for the long-term success of dental implant therapy, and bone remodeling around dental implants is considered to vary with time. Numerous studies comparing the platform-switching (PS) and platform-matching (PM) dental implants have indicated that PS dental implants showed a lesser reduction for the MBL, and the majority of them had a relatively short period. This study aimed to evaluate vertical and horizontal bone defects by using digital periapical radiographs to examine the changes in MBL around PM and PS dental implants over 5 years after functional loading. The vertical MBL (vMBL) was measured from the implant-abutment junction to the first bone-to-implant contact. The horizontal MBL (hMBL) was measured from the implant-abutment junction to the bone crest. All data were presented as means ± standard errors. Paired and independent t-tests with Welch's correction were used to analyze the data. A total of 61 dental implants in 38 patients after 5 years of functional loading were evaluated. Over time, PS dental implants were more likely to gain bone; by contrast, PM dental implants were more likely to lose bone during the observation time. Changes in vMBL for PS dental implants were significantly less than those for PM dental implants at 1-year (p = 0.045), 3-year (p = 0.021), and 5-year (p = 0.010) loading. Likewise, changes in hMBL for PS dental implants were significantly smaller than in those for PM dental implants at 3-year (p = 0.021) and 5-year (p = 0.006) loading; however, the changes were minimal in both approaches. PS dental implants had a significant increment in the percentage of bone integration, whereas that for PM dental implants dropped over time, with no significance. In PS dental implants that occlude with natural teeth, vertical and horizontal bone gain was observed, and it was significant at 3 years (p = 0.023). A significant horizontal bone gain was observed in the opposing natural teeth at 3-year (p = 0.002) and 5-year loading (p = 0.002). The PS concept appears to preserve more MBL around dental implants by stabilizing the vMBL and hMBL over a 5-year period. A minimal marginal bone change was detected in both concepts. The opposing natural teeth at PS dental implants showed a favorable effect on marginal bone tissues.

4.
Polymers (Basel) ; 14(15)2022 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-35956724

RESUMEN

Guided bone regeneration surgery is an important dental operation used to regenerate enough bone to successfully heal dental implants. When this technique is performed on maxilla sinuses, hyaluronic acid (HLA) can be used as an auxiliary material to improve the graft material handling properties. Recent studies have indicated that low-molecular hyaluronic acid (L-HLA) provides a better regeneration ability than high-molecular-weight (H-HLA) analogues. The aim of this study was to fabricate an L-HLA-carboxymethyl cellulose (CMC) hybrid to promote bone regeneration while maintaining viscosity. The proliferation effect of fabricated L-HLA was tested using dental pulp stem cells (DPSCs). The mitogen-activated protein kinase (MAPK) pathway was examined using cells cultured with L-HLA combined with extracellular-signal-regulated kinase (ERK), c-Jun N-terminal kinase (JNK), and p38 inhibitors. The bone growth promotion of fabricated L-HLA/CMC hybrids was tested using an animal model. Micro-computer tomography (Micro-CT) and histological images were evaluated quantitatively to compare the differences in the osteogenesis between the H-HLA and L-HLA. Our results show that the fabricated L-HLA can bind to CD44 on the DPSC cell membranes and affect MAPK pathways, resulting in a prompt proliferation rate increase. Micro CT images show that new bone formation in rabbit calvaria defects treated with L-HLA/CMC was almost two times higher than in defects filled with H-HLA/CMC (p < 0.05) at 4 weeks, a trend that remained at 8 weeks and was confirmed by HE-stained images. According to these findings, it is reasonable to conclude that L-HLA provides better bone healing than H-HLA, and that the L-HLA/CMC fabricated in this study is a potential candidate for improving bone healing efficiency when a guided bone regeneration surgery was performed.

5.
J Pers Med ; 12(7)2022 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-35887548

RESUMEN

Background: The maintenance of marginal bone levels around dental implants is an important criterion for evaluating the success of implants. Although computer-aided design/computer-aided manufacturing (CAD/CAM) customized abutments (CAs) provide more flexible solutions, compared with the original preformed stock abutments (PAs), there are dimensional tolerances and underlying drawbacks in the production of CAD/CAM CAs, which may change the tightness and seamless connection between fixtures and abutments set by the manufacturer and then affect the long-term stability of the abutments. This study aimed to examine the change in both mesial and distal bone levels using digital periapical radiographs to evaluate the difference between CAD/CAM CAs and original PAs.Material and methods: Radiographs were taken before delivery; after functional loading for 1 month; and after 3, 6, and 12 months; and the vertical marginal bone levels (vMBLs) of both the mesial and distal surrounding implant bones were measured. All data are presented as means ± standard errors and were analyzed using Student's t-test. A p-value < 0.05 was judged to represent a significant difference. Results: A total of 57 implants in 50 patients were divided into 22 CAD/CAM CAs and 35 original stock abutments. The PAs appeared to have a more stable bone level. By contrast, the amount of bone level change in the CAs was higher than that in the PAs. The change in the vMBL of the CAs was significantly more than that of the PAs after functional loading for 1 month (p = 0.006), 3 months (p = 0.013), 6 months (p = 0.014), and 12 months (p = 0.002). In contrast, the distal marginal bone level was lower than the mesial marginal bone level in any period. Nevertheless, the bone levels of the CAs and PAs in any period were comparable with no significant difference. Conclusions: Significant differences were found between the mesial and distal bone levels in the PAs. The CAD/CAM CAs showed a significantly greater bone level change than the original stock abutments after functional loading.

6.
Int J Mol Sci ; 23(12)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35743116

RESUMEN

Titanium is widely used in medical implants despite the release of heavy metal ions over long-term use. Zirconia is very close to the color of teeth; however, its biological inertness hinders bonding with bone tissue. Alkaline treatment and coatings of calcium phosphate can be used to enhance bone regeneration adjacent to dental implants. This study examined the effects of alkaline treatment, calcium phosphate coatings, and sintering, on the physical properties of implant material. Our analysis confirmed that the calcium phosphate species were octacalcium phosphate (OCP). The sintering of calcium phosphate was shown to create B-type HAP, which is highly conducive toward the differentiation of mesenchymal stem cells (MSCs) into osteoblasts for the facilitation of bone integration. Conclusions: This study demonstrated the room-temperature fabrication of dental implants with superhydrophilic surfaces to enhance biocompatibility.


Asunto(s)
Materiales Biocompatibles Revestidos , Implantes Dentales , Fosfatos de Calcio , Materiales Biocompatibles Revestidos/farmacología , Oseointegración , Fosfatos , Propiedades de Superficie , Titanio/farmacología , Circonio
7.
Int J Mol Sci ; 23(3)2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35163639

RESUMEN

In vitro, in vivo, and clinical studies have shown how the physicochemical and biological properties of ß-tricalcium phosphate (ß-TCP) work in bone regeneration. This study aimed to improve the properties of ß-TCP by achieving optimum surface and bulk ß-TCP chemical/physical properties through the hydrothermal addition of magnesium (Mg) and to later establish the biocompatibility of ß-TCP/Mg for bone grafting and tissue engineering treatments. Multiple in vitro and in vivo analyses were used to complete ß-TCP/Mg physicochemical and biological characterization. The addition of MgO brought about a modest rise in the number of ß-TCP surface particles, indicating improvements in alkaline phosphatase (ALP) activity on day 21 (p < 0.05) and in the WST-1assay on all days (p < 0.05), with a corresponding increase in the upregulation of ALP and bone sialoprotein. SEM analyses stated that the surfaces of the ß-TCP particles were not altered after the addition of Mg. Micro-CT and histomorphometric analysis from rabbit calvaria critical defects resulted in ß-TCP/Mg managing to reform more new bone than the control defects and ß-TCP control at 2, 6, and 8 weeks (* p ≤ 0.05, ** p ≤ 0.01, *** p ≤ 0.001, and **** p ≤ 0.0001). The hydrothermal addition of MgO to the ß-TCP surfaces ameliorated its biocompatibility without altering its surface roughness resulting from the elemental composition while enhancing cell viability and proliferation, inducing more bone regeneration by osteoconduction in vivo and osteoblastic differentiation in vitro.


Asunto(s)
Regeneración Ósea , Fosfatos de Calcio/farmacología , Diferenciación Celular , Magnesio/farmacología , Osteogénesis , Andamios del Tejido , Animales , Línea Celular , Humanos , Masculino , Conejos
8.
Materials (Basel) ; 13(17)2020 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-32859067

RESUMEN

Peri-implantitis is the pathological condition of connective tissue inflammation and the progressive loss of supporting bone around dental implants. One of the primary causes of peri mucositis evolving into peri-implantitis is bacterial infection, including infection from Porphyromonas gingivalis. Enhancing the surface smoothness of implants helps to prevent P. gingivalis adhesion to the implant's surface. Interaction analyses between bacteria and the surface roughness of zirconia (Zr) discs subjected to a glow discharge plasma (GDP) treatment compared with non-plasma-treated autoclaved control Zr discs were done. Examinations of the material prosperities revealed that the GDP-treated Zr group had a smoother surface for a better wettability. The GDP-treated Zr discs improved the proliferation of the osteoblast-like cells MG-63, and the osteoblastic differentiation was assessed through alkaline phosphatase detection and marker gene bone sialoprotein (Bsp) and osteocalcin (OC) induction. Scanning electron microscopy demonstrated a relatively low P. gingivalis adhesion on GDP-treated Zr disks, as well as lower colonization of P. gingivalis compared with the control. Our findings confirmed that the GDP treatment of Zr discs resulted in a significant reduction of P. gingivalis adhesion and growth, demonstrating a positive correlation between surface roughness and bacteria adhesion. Therefore, the GDP treatment of Zr dental implants can provide a method for reducing the risk of peri-implantitis.

9.
Materials (Basel) ; 13(3)2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32046015

RESUMEN

Porphyromonas gingivalis infection is one of the causes of implant failures, which can lead to peri-implantitis. Implant surface roughness is reportedly related strongly to P. gingivalis adhesion, which can lead to peri-implantitis and, later, cell adhesion. Our aim was to evaluate the effects of Er,Cr:YSGG laser on titanium (Ti) disc surfaces and its interaction with bacterial adhesion and fibroblast viability. Ti discs underwent two treatments: autoclaving (control) and erbium, chromium-doped yttrium scandium gallium garnet (Er,Cr:YSGG) laser treatment (test). Ti disc surfaces were examined with scanning electronic microscope (SEM), Energy-dispersive spectrometry (EDX), X-ray photoelectron spectroscopy (XPS). The surface roughness same as wettability were also investigated. Fibroblast viability was assessed with the water-soluble tetrazolium 1 (WST-1) test, and osteoblast differentiation was assessed with the alkaline phosphatase (ALP) assay. Bacterial structure and colony formation were detected with scanning electron microscopy and Gram stain. In comparison to control discs, the test discs showed smoother surfaces, with 0.25-µm decrease in surface roughness (p < 0.05); lower P. gingivalis adhesion (p < 0.01); less P. gingivalis colonization (p < 0.05); and increased fibroblast viability and osteoblast differentiation (p < 0.05). Er,Cr:YSGG laser treatment improved disc surfaces by making them slightly smoother, which reduced P. gingivalis adhesion and increased fibroblast viability and osteoblast differentiation. Er,Cr:YSGG laser treatment can be considered a good option for managing peri-implantitis. Further investigations of laser-assisted therapy are necessary for better guidelines in the treatment of peri-implantitis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA