1.
Dent Mater ; 29(7): 788-96, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23694844

RESUMEN

OBJECTIVES: A validated numerical model for stress/strain predictions is essential in understanding the biomechanical behavior of implant-supported dental prostheses. The digital image correlation (DIC) method for full-field strain measurement was compared with finite element analysis (FEA) in assessing bone strain induced by implants. METHODS: An epoxy resin model simulating the lower arch was made for the experimental test with acrylic resin replicas of the first premolar and second molar and threaded implants replacing the second premolar and first molar. Splinted (G1/G3) and non-splinted (G2/G4) metal-ceramic screw-retained crowns were fabricated and loaded with (G1/G2) or without (G3/G4) the second molar that provided proximal contact. A single-camera, two-dimensional DIC system was used to record deformation of the resin model surface under a load of 250N. Three-dimensional finite element (FE) models were constructed for the physical models using computer-aided design (CAD) software. Surface strains were used for comparison between the two methods, while internal strains at the implant/resin block interface were calculated using FEA. RESULTS: Both methods found similar strain distributions over the simulant bone block surface, which indicated possible benefits of having splinted crowns and proximal contact in reducing bone strains. Internal strains predicted by FEA at the implant-resin interface were 8 times higher than those on the surface of the model, and they confirmed the results deduced from the surface strains. FEA gave higher strain values than experiments, probably due to incorrect material properties being used. SIGNIFICANCE: DIC is a useful tool for validating FE models used for the biomechanical analysis of dental prosthesis.


Asunto(s)
Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Análisis de Elementos Finitos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Análisis Numérico Asistido por Computador , Análisis de Varianza , Fenómenos Biomecánicos , Fuerza Compresiva , Implantes Dentales , Módulo de Elasticidad , Humanos , Estadísticas no Paramétricas
2.
J Dent Biomech ; 4: 1758736013483747, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23554848

RESUMEN

A preliminary study was conducted on the development of an intelligent dental handpiece with functionality to detect subtle changes in mechanical properties of tooth tissue during milling. Such equipment would be able to adopt changes in cutting parameters and make real-time measurements to avoid tooth tissue damage caused by overexertion and overextension of the cutting tool. A modified dental handpiece, instrumented with strain gauges, microphone, displacement sensor, and air pressure sensor, was mounted to a linear movement table and used to mill three to four cavities in >50 bovine teeth. Extracted sound frequency and density were analyzed along with force, air pressure, and displacement for correlations and trends. Experimental results showed a high correlation (coefficient close to 0.7) between the feed force, the rotational frequency, and the averaged gray scale. These results could form the basis of a feedback control system to improve the safety of dental cutting procedures. This article is written in memory of Dr Hongyan Sun, who passed away in 2011 at a young age of 37.

3.
Dent Mater ; 28(10): 1098-104, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22857877

RESUMEN

OBJECTIVE: A novel technique using a composite disk under diametral compression was presented in a previous study for measuring the bond strength between intracanal posts and dentin. This study deals with the stress distribution within the composite disk to allow the bond strength to be calculated accurately. The effects of changing geometrical and material parameters on the post-dentin interfacial stress are also evaluated. METHODS: The finite element method with 3D models is used to analyze the stress distribution and to carry out the sensitivity analysis. Progressive post-dentin interfacial debonding is also simulated to better understand the failure process observed in experiments. RESULTS: Material mismatch causes stress concentrations at the interfaces. The results are presented as correction factors to be used in conjunction with the analytical solution for a homogeneous disk. Comparison between the stresses at the post-dentin interface and those in dentin confirms that interfacial debonding will take place prior to fracture in the dentin. SIGNIFICANCE: The numerical solutions presented here will facilitate the adoption of the composite disk in diametral compression for bond strength measurement.


Asunto(s)
Resinas Compuestas/química , Análisis del Estrés Dental/métodos , Recubrimientos Dentinarios/química , Dentina/química , Análisis de Elementos Finitos , Ensayo de Materiales , Modelos Dentales , Propiedades de Superficie , Resistencia a la Tracción
4.
Acta Biomater ; 8(4): 1597-602, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22266033

RESUMEN

New methods are needed that can predict the clinical failure of dental restorations that primarily rely on dentin bonding. Existing methods have shortcomings, e.g. severe deviation in the actual stress distribution from theory and a large standard deviation in the measured bond strength. We introduce here a novel test specimen by examining an endodontic model for dentin bonding. Specifically, we evaluated the feasibility of using the modified Brazilian disk test to measure the post-dentin interfacial bond strength. Four groups of resin composite disks which contained a slice of dentin with or without an intracanal post in the center were tested under diametral compression until fracture. Advanced nondestructive examination and imaging techniques in the form of acoustic emission (AE) and digital image correlation (DIC) were used innovatively to capture the fracture process in real time. DIC showed strain concentration first appearing at one of the lateral sides of the post-dentin interface. The appearance of the interfacial strain concentration also coincided with the first AE signal detected. Utilizing both the experimental data and finite-element analysis, the bond/tensile strengths were calculated to be: 11.2 MPa (fiber posts), 12.9 MPa (metal posts), 8.9 MPa (direct resin fillings) and 82.6 MPa for dentin. We have thus established the feasibility of using the composite disk in diametral compression to measure the bond strength between intracanal posts and dentin. The new method has the advantages of simpler specimen preparation, no premature failure, more consistent failure mode and smaller variations in the calculated bond strength.


Asunto(s)
Resinas Compuestas/química , Fuerza Compresiva , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Ensayo de Materiales/métodos , Acústica , Análisis de Elementos Finitos , Humanos , Procesamiento de Imagen Asistido por Computador , Resistencia a la Tracción , Factores de Tiempo , Microtomografía por Rayos X
5.
J Oral Implantol ; 38(4): 311-23, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20712446

RESUMEN

Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61° and 2.39° in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01° to 9.7°. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.


Asunto(s)
Implantación Dental Endoósea/instrumentación , Implantes Dentales , Arco Dental/patología , Arco Dental/cirugía , Implantación Dental Endoósea/normas , Implantes Dentales/estadística & datos numéricos , Diseño de Equipo , Humanos , Internado y Residencia , Arcada Parcialmente Edéntula/clasificación , Arcada Parcialmente Edéntula/cirugía , Maxilar/patología , Maxilar/cirugía , Modelos Dentales , Periodoncia/educación , Método Simple Ciego , Estudiantes de Odontología
6.
J Prosthodont Res ; 56(1): 25-31, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21684233

RESUMEN

PURPOSE: A digital image correlation (DIC) method for full-field surface strain measurement was used to analyze the effect of two veneering materials for implant supported crowns on the strain distribution within the surrounding bone. METHODS: An epoxy resin model of a bone block was made by housing acrylic resin replicas of a mandibular first premolar and second molar together with threaded implants replacing the second premolar and first molar. Porcelain-veneered (G1 and G3) and resin-veneered (G2 and G4) screw-retained splinted crowns were fabricated and loaded with (G1 and G2) and without (G3 and G4) the presence of the second molar replica. A 2-dimensional DIC measuring system was used to record surface deformation of the bone block model at a frequency of 1.0 Hz during application of a 250-N load. RESULTS: Maximum compressive strains (ɛ(XX), %) were found for the following regions: between molars, G1 (-0.21), G2 (-0.18), G3 (-0.26), and G4 (-0.25); between implants, G1 (-0.19), G2 (-0.13), G3 (-0.19), and G4 (-0.14). The magnitude of strains in the simulated bone block with the resin-veneered crowns was lower than that with porcelain-veneered crowns, irrespective of the presence or absence of the second molar. CONCLUSIONS: The softer resin veneer helped to spread the load more evenly amongst the supporting teeth and implants, thus reducing the strains in the simulant bone block. Conversely, using the harder porcelain veneer resulted in the load being concentrated within one or two teeth or implants, thus leading to higher strain values in the bone block.


Asunto(s)
Huesos/fisiología , Coronas , Implantes Dentales , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Estrés Mecánico , Materiales Dentales , Coronas con Frente Estético , Dentadura Parcial Fija , Humanos , Resinas Sintéticas
7.
J Biomech ; 44(6): 1008-13, 2011 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-21377159

RESUMEN

This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0Hz under a load from 0 to 250N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact.


Asunto(s)
Diente Premolar , Implantes Dentales , Procesamiento de Imagen Asistido por Computador , Diente Molar , Resistencia al Corte , Estrés Mecánico , Análisis de Falla de Equipo/métodos , Humanos , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...