Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Pathogens ; 13(3)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38535606

RESUMEN

The COVID-19 pandemic has underscored the pivotal role of epidemiology in studying pathogenic agents [...].

3.
Sensors (Basel) ; 22(21)2022 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-36366194

RESUMEN

The most robust and economical method for laboratory diagnosis of tuberculosis (TB) is to identify mycobacteria acid-fast bacilli (AFB) under acid-fast staining, despite its disadvantages of low sensitivity and labor intensity. In recent years, artificial intelligence (AI) has been used in TB-smear microscopy to assist medical technologists with routine AFB smear microscopy. In this study, we evaluated the performance of a TB automated system consisting of a microscopic scanner and recognition program powered by artificial intelligence and machine learning. This AI-based system can detect AFB and classify the level from 0 to 4+. A total of 5930 smears were evaluated on the performance of this automatic system in identifying AFB in daily lab practice. At the first stage, 120 images were analyzed per smear, and the accuracy, sensitivity, and specificity were 91.3%, 60.0%, and 95.7%, respectively. In the second stage, 200 images were analyzed per smear, and the accuracy, sensitivity, and specificity were increased to 93.7%, 77.4%, and 96.6%. After removing disqualifying smears caused by poor staining quality and smear preparation, the accuracy, sensitivity, and specificity were improved to 95.2%, 85.7%, and 96.9%, respectively. Furthermore, the automated system recovered 85 positive smears initially identified as negative by manual screening. Our results suggested that the automated TB system could achieve higher sensitivity and laboratory efficiency than manual microscopy under the quality control of smear preparation. Automated TB smear screening systems can serve as a screening tool at the first screen before manual microcopy.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis , Humanos , Inteligencia Artificial , Tuberculosis/diagnóstico , Microscopía/métodos , Coloración y Etiquetado , Sensibilidad y Especificidad
4.
Pathogens ; 11(10)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36297160

RESUMEN

Introduction: Extracorporeal shock wave lithotripsy (ESWL) is a well-established, popular treatment choice for renal stones. Traditionally, the semi-liquid gel is used as a coupling medium in ESWL. During ESWL, body fluid or blood might transmit between the patients when the probe or gel used in the procedure is contaminated and cause potential nosocomial infections. To solve this problem, we developed a solid coupling medium (isolation coupling pad, referred to as "icPad") between the patient's skin and the probe as a shock wave transmission medium to prevent contamination. This study aimed to investigate the isolative efficacy of the icPad in blocking the permeation of microbes. Method: Rhodamine 6G (a fluorescent dye) was used as a tracer to simulate the microorganisms. The penetration of the fluorescent dye on the longitudinal section of the icPad was observed by a microscope after the dye was placed on the body side of the icPad for 40 min. After the shock wave, icPad was extracted with 75% ethanol, and fluorescence intensity was measured with a fluorescence spectrometer. Results: Our results revealed that the body side of icPad is free of fluorescent dye during lithotripsy. Qualitative analysis results confirmed that icPad has an isolative effect on simulating contaminants such as bacteria or viruses. Conclusion: In this in vitro phantom study, a proprietary icPad can be an isolative coupling medium and is speculated to avoid cross-contamination of bacterial or viral infection during ESWL.

5.
BMC Urol ; 22(1): 56, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413871

RESUMEN

This study aimed to investigate clinical effectiveness of stone disintegration by using isolation coupling pad ("icPad") as coupling medium to reduce trapped air pockets during extracorporeal shock wave lithotripsy (ESWL). Patients underwent ESWL between Oct. 2017 and May 2018 were enrolled in this clinical observational study. An electromagnetic lithotripter (Dornier MedTech Europe GmbH Co., Germany) was used in this study. Patients were divided into icPad group P1, P2 and semi-gel group C by different coupling medium. The energy level and total number of shock wave (SW) for group P1 and C was set at level 2 and 3000 and group P2 at level 3 and 2500. The successful stone disintegration rate (SSDR) was determined to evaluate the treatment outcome. All patients were evaluated by KUB film and ultrasonography after 90 days. Complications during ESWL were recorded. A total of 300 patients satisfied the inclusion criteria. There were no significant differences in characteristics of patients and stone among three groups. The corresponding SSDRs for patients in group P1, P2 and C was 73.0%, 73.2% and 55.3%, respectively. The SSDR in group P1 was statistically higher than Group C. Comparing to semi-liquid gel, coupling medium using by icPad could achieve better treatment outcome of stone disintegration in ESWL.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Fatiga , Humanos , Cálculos Renales/terapia , Resultado del Tratamiento , Cálculos Ureterales/terapia
6.
BMC Urol ; 21(1): 79, 2021 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-33990213

RESUMEN

INTRODUCTION: Air pockets between the lithotripter head and body surface are almost inevitably generated when applying a handful of gel onto the contact portion of the treatment head and that on the patient's skin during coupling procedure. These air pockets can compromise the transmission of acoustic energy of shock wave and may significantly affect efficacy of stone disintegration. Comparing to conventional gel, this study aims to investigate efficacy of stone disintegration by using a proprietary isolation-coupling pad ("icPad") as the coupling medium to reduce trapped air pockets during ESWL procedure. METHOD: In this phantom study, Dornier lithotripter (Delta-2 RC, Dornier MedTech Europe GmbH Co., Germany) was used with a proprietary gel pads (icPad, Diameter = 150 mm, Thickness = 4 mm and 8 mm). The lithotripter was equipped with inline camera to observe the trapped air pockets between the contact surface of the lithotripter head. A testing and measuring device were used to observe experimental stone disintegration using icPad and semi-liquid gel. The conventional semi-liquid gel was used as control for result comparison. RESULTS: The stone disintegration rate of icPad 4 mm and 8 mm after 200 shocks of energy at level 2 were significantly higher than that of the semi-liquid gel (disintegration rate 92.3%, 85.0% vs. 45.5%, respectively, p < 0.001). The number of shocks for complete stone disintegration by icPad of 4 mm and 8 mm at the same energy level 2 were significantly lower than that of the semi-liquid gel (the number of shocks 242.0 ± 13.8, 248.7 ± 6.3 vs. 351.0 ± 54.6, respectively, p = 0.011). Furthermore, quantitative comparison of observed air pockets under Optical Coupling Control (OCC) system showed that the area of air pockets in semi-liquid group was significantly larger than that of the group using icPad (8 mm) and that of the group using icPad (8 mm) after sliding (332.7 ± 91.2 vs. 50.3 ± 31.9, 120.3 ± 21.5, respectively, p < 0.05). CONCLUSION: The advantages of icPad includes: (1) reduced the numbers of shock wave and increased stone disintegration rate due to icPad's superior efficacy; (2) significantly reduce trapped air pockets in ESWL coupling. Due to the study limitation, more data are needed to confirm our observations before human trials.


Asunto(s)
Geles , Litotricia/métodos , Aire , Humanos , Litotricia/instrumentación , Fantasmas de Imagen
7.
J Clin Microbiol ; 47(10): 3226-30, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19587299

RESUMEN

This study was designed to determine the strength of the association between the isolation of nonfermentative gram-negative bacilli (NFGNB) from tap water faucet aerators and the prevalence of colonization or infection of patients in intensive care units (ICUs). Surveillance cultures were obtained during a 4-month period from 162 faucet aerators located in seven different ICUs. The prevalence of colonization or infection of ICU patients with NFGNB was determined by prospective surveillance during the same period. Fifty four (33%) of the faucet aerators contained NFGNB. Among the 66 NFGNB isolated from faucet aerators, the most frequently encountered ones were Sphingomonas paucimobili (26 isolates), Pseudomonas aeruginosa (14 isolates), Chryseobacterium meningosepticum (13 isolates), Achromobacter xylosoxidans (6 isolates), Burkholderia cepacia (4 isolates), and Stenotrophomonas maltophilia (3 isolates). Acinetobacter baumannii was not recovered. The most common NFGNB isolated from ICU patients were P. aeruginosa and A. baumannii. There was a significant correlation between the overall prevalence of NFGNB in faucet aerators and their prevalence in exposed ICU patients (Spearman r = 0.821, P = 0.02). There was also a significant correlation between the prevalence of C. meningosepticum in faucet aerators and its prevalence among ICU patients (Spearman r = 0.847, P = 0.016). The electrokaryotypes of four clinical isolates of C. meningosepticum were similar to those of faucet isolates. Measures directed at making the water supply safe may prevent infection by C. meningosepticum and other waterborne pathogens.


Asunto(s)
Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Microbiología Ambiental , Bacterias Gramnegativas/clasificación , Bacterias Gramnegativas/aislamiento & purificación , Infecciones por Bacterias Gramnegativas/epidemiología , Infecciones por Bacterias Gramnegativas/microbiología , Técnicas de Tipificación Bacteriana , Portador Sano/epidemiología , Portador Sano/microbiología , Análisis por Conglomerados , Dermatoglifia del ADN , ADN Bacteriano/genética , Genotipo , Humanos , Unidades de Cuidados Intensivos , Epidemiología Molecular , Prevalencia , Taiwán/epidemiología
8.
Int J Infect Dis ; 12(4): 416-20, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18243750

RESUMEN

BACKGROUND: The major sources of Legionnaires' disease (LD) are the potable water systems of large buildings including hospitals, nursing homes, and hotels. Culturing the hospital water system for Legionella allows a preventive approach for hospital-acquired LD. However, hospital-acquired LD is rarely reported in Taiwan, and environmental cultures of Legionella in hospital water systems in Taiwan have never been systematically performed. OBJECTIVE: The objective of this study was to determine if Legionella is present in hospital water systems in Taiwan. Water quality analysis was also performed to determine if geographic differences in water quality result in different Legionella positivity rates. METHOD: The water systems of 16 hospitals throughout Taiwan were tested for Legionella by culture. Standardized culture procedures were followed. RESULTS: Legionella pneumophila was isolated from 63% (10/16) of the hospital water systems; 19% (3/16) of the hospitals had an L. pneumophila positive rate greater than 30%. L. pneumophila serogroups 1 and 6 (strains that are most responsible for Legionella infections) were isolated from 80% (8/10) and 60% (6/10), respectively, of the hospitals that yielded L. pneumophila in their water distribution systems. CONCLUSION: As was shown in epidemiological studies in the USA and Spain, hospital-acquired legionellosis may be prevalent but underdiagnosed in Taiwan.


Asunto(s)
Equipos y Suministros de Hospitales/microbiología , Legionella pneumophila/aislamiento & purificación , Microbiología del Agua , Abastecimiento de Agua/análisis , Humanos , Control de Infecciones , Administración de la Seguridad , Taiwán
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...