Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 382
Filtrar
1.
Eur Heart J ; 2024 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-39397777

RESUMEN

Despite key advances in catheter-based treatments, the management of persistent atrial fibrillation (AF) remains a therapeutic challenge in a significant subset of patients. While success rates have improved with repeat AF ablation procedures and the concurrent use of antiarrhythmic drugs, the likelihood of maintaining sinus rhythm during long-term follow-up is still limited. Atrioventricular node ablation (AVNA) has returned as a valuable treatment option given the recent developments in cardiac pacing. With the advent of conduction system pacing, AVNA has seen a revival where pacing-induced cardiomyopathy after AVNA is felt to be overcome. This review will discuss the role of permanent pacemaker implantation and AVNA for AF management in this new era of conduction system pacing. Specifically, this review will discuss the haemodynamic consequences of AF and the mechanisms through which 'pace-and-ablate therapy' enhances outcomes, analyse historical and more recent literature across various pacing methods, and work to identify patient groups that may benefit from earlier implementation of this approach.

2.
Europace ; 26(10)2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39344253

RESUMEN

AIMS: Reduction of atrial fibrillation (AF) burden is the preferred outcome measure over categorical AF rhythm recurrence after AF ablation. In this sub-analysis of the TeleCheck-AF project, we tested the feasibility of smartphone app-based approximation of time spent with AF and/or symptoms. METHODS AND RESULTS: Patients scheduled for at least one teleconsultation during the 12-month follow-up after AF ablation were instructed to use a smartphone photoplethysmography-based application for simultaneous symptom and rhythm monitoring three times daily for 1 week. Proxies of time spent with AF and/or symptoms (% recordings, load, and % days), temporal aggregation of AF and/or symptoms (density), and symptom-rhythm correlation (SRC) were assessed. In total, 484 patients (60% male, 62 ± 9.9 years) were included. Adherence, motivation, and patient satisfaction were high. %AF recordings, AF load, and %AF days (rs = 0.88-0.95) and %symptom recordings, symptom load, and %symptom days (rs = 0.95-0.98) showed positive correlations. The SRC correlated negatively with time spent with symptoms (rs = -0.65-0.90) and with time spent with AF (rs = -0.31-0.34). In patients with paroxysmal AF before ablation and AF during the monitoring period, 87% (n = 39/44) had a low-density score <50% ('paroxysmal AF pattern') while 5% (n = 2/44) had a high-density score >90% ('persistent AF pattern'). Corresponding numbers for patients with persistent AF before ablation were 48% (n = 11/23) and 43% (n = 10/23), respectively. CONCLUSION: On-demand, app-based simultaneous rhythm and symptom assessment provides objective proxies of time spent with AF and/or symptoms and SRC, which may assist in assessing AF and symptom outcomes after AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Aplicaciones Móviles , Teléfono Inteligente , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Factores de Tiempo , Resultado del Tratamiento , Fotopletismografía/instrumentación , Fotopletismografía/métodos , Satisfacción del Paciente/estadística & datos numéricos , Recurrencia , Frecuencia Cardíaca , Consulta Remota , Cooperación del Paciente/estadística & datos numéricos , Telemedicina , Motivación
3.
Int J Cardiol ; 417: 132526, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39244096

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, yet its underlying pathophysiology remains poorly understood. This study assessed whether circulating biomarker concentrations differ in paroxysmal AF patients during an acute episode compared to sinus rhythm. METHODS: The Time of Calamity study is a prospective biomarker study within the RACE V study. Patients underwent venous blood sampling in sinus rhythm at inclusion in RACE V, as well as during a subsequent acute episode of AF for which patients reported to the hospital. Ten biomarkers were analyzed. RESULTS: Thirty-nine patients (mean age 60 ± 9 years, 10 (25 %) women) were enrolled. During an acute AF episode, dickkopf-related protein 3 and insulin-like growth factor binding protein 7 were significantly lower, while N-terminal pro B-type natriuretic peptide (NT-proBNP), high-sensitive troponin T (hsTnT), growth differentiation factor 15, and interleukin 6 were significantly higher (all p < 0.05). CONCLUSIONS: Biomarker concentrations in paroxysmal AF patients are dynamic and differ between sinus rhythm and acute AF episodes. Notably, NT-proBNP and hsTnT, commonly used in clinical practice, were significantly elevated during an acute AF episode.


Asunto(s)
Fibrilación Atrial , Biomarcadores , Humanos , Fibrilación Atrial/sangre , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Biomarcadores/sangre , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Enfermedad Aguda , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Frecuencia Cardíaca/fisiología , Troponina T/sangre
4.
Eur Heart J ; 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39288159

RESUMEN

Atrial fibrillation (AF) is the most prevalent sustained cardiac arrhythmia. Comprehensive modification of established AF risk factors combined with dietary interventions and breaking deleterious habits has been shown to reduce AF burden and recurrence. Numerous AF risk factors, such as diabetes, obesity or hypertension can be partially related to dietary and lifestyle choices. Therefore, dietary interventions may have potential as a therapeutic approach in AF. Based on available data, current guidelines recommend alcohol abstinence or reduction to decrease AF symptoms, burden, and progression, and do not indicate the need for caffeine abstention to prevent AF episodes (unless it is a trigger for AF symptoms). Uncertainty persists regarding harms or benefits of other dietary factors including chocolate, fish, salt, polyunsaturated and monounsaturated fatty acids, vitamins, and micronutrients. This article provides a systematic review of the association between AF and both dietary patterns and components. Additionally, it discusses potentially related mechanisms and introduces different strategies to assess patients' nutrition patterns, including mobile health solutions and diet indices. Finally, it highlights the gaps in knowledge requiring future investigation.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39313856

RESUMEN

INTRODUCTION: Left bundle branch area pacing (LBBAP) comprises pacing at the left ventricular septum (LVSP) or left bundle branch (LBBP). The aim of the present study was to investigate the differences in ventricular electrical heterogeneity between LVSP, LBBP, right ventricular pacing (RVP) and intrinsic conduction with different dyssynchrony measures using the ECG, vectorcardiograpy, ECG belt, and Ultrahigh frequency (UHF-)ECG. METHODS: Thirty-seven patients with a pacemaker indication for bradycardia or cardiac resynchronization therapy underwent LBBAP implantation. ECG, vectorcardiogram, ECG belt and UHF-ECG signals were recorded during RVP, LVSP and LBBP, and intrinsic activation. QRS duration (QRSd) was measured from the ECG, QRS area was calculated from the vectorcardiogram, LV activation time (LVAT) and standard deviation of activation time (SDAT) from ECG belt and electrical dyssynchrony (e-DYS16) from UHF-ECG. RESULTS: Both LVSP and LBBP significantly reduced ventricular electrical heterogeneity as compared to underlying LBBB and RV pacing in terms of QRS area (p < .001), SDAT (p < .001), LVAT (p < .001) and e-DYS16 (p < .001). QRSd was only reduced as compared to RV pacing(p < .001). QRS area was similar during LBBP and normal intrinsic conduction, e-DYS16 was similar during LVSP and normal intrinsic conduction, whereas SDAT was similar for LVSP, LBBP and normal intrinsic conduction. For all these variables there was no significant difference between LVSP and LBBP. CONCLUSION: Both LVSP and LBBP resulted in a more synchronous LV activation than LBBB and RVP. Especially LBBP resulted in levels of LV synchrony comparable to normal intrinsic conduction.

6.
Heart Rhythm ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39127229

RESUMEN

BACKGROUND: Bursting nonsustained cardiac arrhythmia events are a common observation during sleep. OBJECTIVES: The purpose of this study was to investigate the hypothesis that nocturnal arrhythmia episode durations could follow a power law, whose exponent could predict long-term clinical outcomes. METHODS: We defined "nocturnal arrhythmia avalanche" (NAA) as any instance of a drop in electrocardiographic (ECG) template-matched R-R intervals ≥30% of R-R baseline, followed by a return to 90% of baseline. We studied NAA in ECG recordings obtained from the Sleep Heart Health Study (SHHS), Osteoporotic Fractures in Men Study (MrOS) Study, and Multi-Ethnic Study of Atherosclerosis (MESA). The association of nocturnal arrhythmia durations with a power-law distribution was evaluated and the association of derived power-law exponents (α) with major adverse cardiovascular (CV) events and mortality assessed with multivariable Cox regression. RESULTS: A total of 9176 participants were studied. NAA episodes distribution was consistent with power-law vs comparator distributions in all datasets studied (positive log likelihood ratio of power-law vs exponential in MESA: 83%; SHHS: 69%; MrOS: 81%; power-law vs log-normal in MESA: 95%; SHHS: 35%; MrOS: 64%). The NAA power-law exponent (α) showed a significant association of with adverse CV outcomes (association with CV mortality: SHHS hazard ratio 1.39 [1.07-1.79], P = .012; MrOS hazard ratio 1.42 [1.02-1.94], P = .039; association with CV events: MESA HR 3.46 [1.46-8.21], P = .005) in multivariable Cox regression, after adjusting for conventional CV risk factors and nocturnal ectopic rate. CONCLUSION: The NAA power-law exponent is a reproducible, predictive marker for incident CV events and mortality.

7.
Heart Rhythm ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39121980

RESUMEN

BACKGROUND: Early postoperative atrial fibrillation (POAF) is common after cardiac surgery and is associated with late-POAF recurrences. However, little is known about the burden of POAF and its potential impact on long-term outcomes after cardiac surgery, particularly on the risk for late-POAF recurrences. OBJECTIVE: The purpose of this study was to establish the distribution of POAF burden and to determine the association between early-POAF burden and late-POAF recurrences during 2.5 years of continuous rhythm monitoring after cardiac surgery in patients with and without preoperative history of atrial fibrillation (AF). METHODS: Patients undergoing cardiac surgery were prospectively enrolled and postoperatively continuously monitored with an implantable loop recorder for 2.5 years. All patients underwent extensive clinical assessment at baseline. During follow-up, all AF episodes were registered, and AF associated metrics, such as burden, were calculated for different time intervals. Early-POAF was defined as AF within first 90 postoperative days and late-POAF as AF after this interval. RESULTS: A total of 98 consecutive patients were included. POAF burden during the early postoperative phase was significantly higher compared to the late postoperative phase (P <.001). The longest individual POAF episode was strongly associated with increased POAF burden after adjusting for age, sex, and AF history (standardized Beta: 0.91, P <.001). Also, early-POAF burden was associated with late-POAF (re)occurrence after adjusting for age, sex, AF history (adjusted hazard ratio 1.93, 95% confidence interval 1.42-2.62, P <.001). CONCLUSION: POAF burden was significantly associated with the longest individual POAF episode duration. Additionally, greater early-POAF burden was associated with increased late-POAF incidence, highlighting its potential in estimating the risk for long-term POAF recurrences.

8.
Hypertension ; 81(10): 2027-2037, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39136127

RESUMEN

More than 1.5 billion people worldwide have arterial hypertension. Hypertension increases the risks of death and cardiovascular disease, such as atrial fibrillation and heart failure. The autonomic nervous system plays an essential role in hypertension development and disease progression. While lifestyle factors, such as obesity and obstructive sleep apnea, predispose to hypertension by increasing sympathetic activity, hypertension itself maintains the autonomic nervous imbalance, providing the substrate for atrial fibrillation and heart failure. Therefore, autonomic nervous system modulation either by direct targeting or indirect treatment of comorbidities has the potential to treat both hypertension and related atrial and ventricular end-organ damage. We discuss interventions for the modulation of the autonomic nervous system for hypertension and related cardiac end-organ damage, including pharmacological adrenergic beta-receptor blockade, renal denervation, carotid baroreceptor stimulation, low-level vagal stimulation, and ablation of ganglionated plexuses. In summary, the literature suggests that targeting the autonomic nervous system potentially represents a therapeutic approach to prevent atrial and ventricular end-organ damage in patients with hypertension. However, clinical trials specifically designed to test the effect of autonomic modulation on hypertension-mediated cardiac end-organ damage are scarce.


Asunto(s)
Sistema Nervioso Autónomo , Hipertensión , Humanos , Hipertensión/fisiopatología , Hipertensión/terapia , Sistema Nervioso Autónomo/fisiopatología , Antagonistas Adrenérgicos beta/uso terapéutico , Antagonistas Adrenérgicos beta/farmacología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia
11.
Heart Rhythm ; 21(10): 1877-1887, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38971417

RESUMEN

BACKGROUND: Idiopathic epicardial premature ventricular contractions (PVCs) originating from the left ventricular summit are difficult to eliminate. OBJECTIVE: The purpose of this study was to describe the feasibility and procedural safety of monopolar biphasic focal pulsed field ablation (F-PFA) from within the great cardiac vein (GCV) for treatment of idiopathic epicardial PVCs. METHODS: In 4 pigs, F-PFA (Centauri, CardioFocus) was applied from within the GCV followed by macroscopic gross analysis. In 4 patients with previously failed radiofrequency ablation, electroanatomic mapping was used to guide F-PFA from within the GCV and the ventricular outflow tracts. Coronary angiography and optical coherence tomography (OCT) were performed in 2 patients. RESULTS: In pigs, F-PFA from within the GCV (5 mm away from the coronary arteries) resulted in myocardial lesions with a maximal depth of 4 mm, which was associated with nonobstructive transient coronary spasms. In patients, sequential delivery of F-PFA in the ventricular outflow tracts and from within the GCV eliminated the PVCs. During F-PFA delivery from within the GCV with prophylactic nitroglycerin application, coronary angiography showed no coronary spasm when F-PFA was delivered >5 mm away from the coronary artery and a transient coronary spasm without changes in a subsequent OCT, when F-PFA was delivered directly on the coronary artery. Intracardiac echocardiography and computed tomography integration was used to monitor F-PFA delivery from within the GCV. There were no immediate or short-term complications. CONCLUSION: Sequential mapping-guided F-PFA from endocardial ventricular outflow tracts and from within the GCV is feasible with a favorable procedural safety profile for treatment of epicardial PVCs.


Asunto(s)
Ablación por Catéter , Angiografía Coronaria , Complejos Prematuros Ventriculares , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía , Complejos Prematuros Ventriculares/diagnóstico , Animales , Ablación por Catéter/métodos , Porcinos , Humanos , Masculino , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Persona de Mediana Edad , Femenino , Tomografía de Coherencia Óptica/métodos , Estudios de Factibilidad , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Modelos Animales de Enfermedad , Electrocardiografía , Insuficiencia del Tratamiento
13.
Eur Heart J Digit Health ; 5(4): 461-468, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39081939

RESUMEN

Aims: Direct current cardioversion (DCCV) is a commonly utilized rhythm control technique for atrial fibrillation. Follow-up typically comprises a hospital visit for 12-lead electrocardiogram (ECG) two weeks post-DCCV. We report the feasibility, costs, and environmental benefit of remote photoplethysmography (PPG) monitoring as an alternative. Methods and results: We retrospectively analysed DCCV cases at our centre from May 2020 to October 2022. Patients were stratified into those with remote PPG follow-up and those with traditional 12-lead ECG follow-up. Monitoring type was decided by the specialist nurse performing the DCCV at the time of the procedure after discussing with the patient and offering them both options if appropriate. Outcomes included the proportion of patients who underwent PPG monitoring, patient compliance and experience, and cost, travel, and environmental impact. Four hundred sixteen patients underwent 461 acutely successful DCCV procedures. Two hundred forty-six underwent PPG follow-up whilst 214 underwent ECG follow-up. Patient compliance was high (PPG 89.4% vs. ECG 89.8%; P > 0.999) and the majority of PPG users (90%) found the app easy to use. Sinus rhythm was maintained in 71.1% (PPG) and 64.7% (ECG) of patients (P = 0.161). Twenty-nine (11.8%) PPG patients subsequently required an ECG either due to non-compliance, technical failure, or inconclusive PPG readings. Despite this, mean healthcare costs (£47.91 vs. £135 per patient; P < 0.001) and median cost to the patient (£0 vs. £5.97; P < 0.001) were lower with PPG. Median travel time per patient (0 vs. 44 min; P < 0.001) and CO2 emissions (0 vs. 3.59 kg; P < 0.001) were also lower with PPG. No safety issues were identified. Conclusion: Remote PPG monitoring is a viable method of assessing for arrhythmia recurrence post-DCCV. This approach may save patients significant travel time, reduce environmental CO2 emission, and be cost saving in a publicly-funded healthcare system.

14.
Card Electrophysiol Clin ; 16(3): 271-280, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39084720

RESUMEN

Several complex mechanisms, working alone, or together, initiate and maintain atrial fibrillation (AF). At disease onset, pulmonary vein-atrial triggers, producing ectopy, predominate. Then, as AF progresses, a shift toward substrate occurs, which AF also self-perpetuates. The autonomic nervous system (ANS) plays an important role as trigger and substrate. Although the efferent arm of the ANS as AF trigger is well-established, there is emerging evidence to show that (1) the ANS is a substrate for AF and (2) afferent or regulatory ANS dysfunction occurs in AF patients. These findings could represent a mechanism for the progression of AF.


Asunto(s)
Fibrilación Atrial , Sistema Nervioso Autónomo , Fibrilación Atrial/fisiopatología , Humanos , Sistema Nervioso Autónomo/fisiopatología
15.
Artículo en Inglés | MEDLINE | ID: mdl-39001763

RESUMEN

BACKGROUND: Dark-blood late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) has better correlation with bipolar voltage (BiV) to define ablation scar in the left atrium (LA) compared to conventional bright-blood LGE CMR. OBJECTIVES: This study sought to determine the optimal signal intensity threshold of dark-blood LGE CMR to identify LA ablation scar. METHODS: In 54 patients scheduled for atrial fibrillation ablation, image intensity ratios (IIRs) were derived from preprocedural dark-blood LGE CMR. In 26 patients without previous ablation, the upper limit of normal was derived from the 95th and 98th percentiles of pooled IIR values. In 28 patients with previous atrial fibrillation ablation, BiV was compared with the corresponding IIR. Receiver-operating characteristics analyses were employed to determine the optimal IIR threshold (ie, the point with the smallest distance to the upper left corner of the receiver-operating characteristics) for LA ablation scar (BiV ≤0.15 mV). RESULTS: Upper limit of normal corresponded to IIR values 1.16 and 1.21, yielding low sensitivities of 0.32 and 0.09 to detect LA ablation scar. Receiver-operating characteristics analysis of IIR and BiV comparison achieved a median area under the curve of 0.77. Median optimal IIR threshold for LA ablation scar was 1.09, with an average sensitivity of 0.73, specificity of 0.75, and accuracy of 0.71. Median IIR thresholds of 1.00 and 1.10 corresponded to 80% sensitivity and 80% specificity, respectively. There was considerable interpatient variability: optimal IIR thresholds per patient ranged from 1.01 to 1.22. CONCLUSIONS: The optimal IIR threshold to identify LA ablation scar by dark-blood LGE CMR is 1.09. Because of interpatient variability, the investigators recommend using a lower (1.00) and upper (1.10) threshold to prevent over- or underestimation of ablation scar.

16.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
17.
Heart ; 110(16): 1030-1039, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-38944418

RESUMEN

BACKGROUND: We aimed to evaluate the association between atrial fibrillation (AF) burden, duration and number of episodes with healthcare utilisation and quality of life in patients with early paroxysmal AF without a history of AF. METHODS: In this observational cohort study, we included 417 patients with paroxysmal AF from the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V) Study. Patients were monitored with an insertable cardiac monitor for 1 year. Outcomes collected were healthcare utilisation, and quality of life assessed using the Atrial Fibrillation Severity Scale and EuroQol EQ-5D-5L questionnaires. RESULTS: During 1 year of follow-up, 63 973 AF episodes were detected in 353 (85%) patients. The median AF burden was 0.7% (IQR 0.1-4.0%). AF ablation was performed more frequently in patients with intermediate-to-high AF burdens (>0.2%) (16.2% vs 5.9%, p=0.01) and longer AF episode duration (>1 hour) (15.8% vs 2.0%, p=0.01), whereas cardioversions were more frequent in patients with longer episode duration (>1 hour) (9.5% vs 0%, p=0.04) and intermediate (0.2-1.9%) (but not high) AF burdens (13.6% vs 4.2%, p=0.01). Patients with many episodes (>147) reported higher symptom severity (p=0.001). No differences in symptom severity nor in EQ-5D-5L scores according to AF burden or duration were observed. CONCLUSION: In patients with early paroxysmal AF, higher AF burden and longer episode duration were associated with increased rates of healthcare utilisation but not with symptoms and quality of life. Patients with a higher number of episodes experienced more severe symptoms. TRIAL REGISTRATION NUMBER: NCT02726698.


Asunto(s)
Fibrilación Atrial , Calidad de Vida , Humanos , Fibrilación Atrial/terapia , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Ablación por Catéter/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Aceptación de la Atención de Salud/estadística & datos numéricos , Cardioversión Eléctrica/estadística & datos numéricos , Encuestas y Cuestionarios
18.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
19.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38758963

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. METHODS AND RESULTS: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. CONCLUSION: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Modelos Animales de Enfermedad , Venas Pulmonares , Animales , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/prevención & control , Fibrilación Atrial/diagnóstico , Porcinos , Ablación por Catéter/métodos , Apnea Obstructiva del Sueño/fisiopatología , Insuficiencia del Tratamiento , Frecuencia Cardíaca , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...