Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Asunto principal
Intervalo de año de publicación
1.
Rev Sci Instrum ; 85(2): 02A707, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593441

RESUMEN

Intensity of hydrogen Balmer-alpha line is sensitive to distribution of populations of sublevels of excited state due to difference of radiative decay branching ratio for sublevels with different orbital quantum number. Since these sublevels are degenerate transitions between sublevels and mixing of its population may be caused by very weak action of environment. A beam of fast hydrogen atoms is a system in which these fine effects of population mixing can be observed. Experimental data of Hα line radiation intensities in hydrogen neutral beams are compared with calculations assumed different models of sublevel population. The comparison most probably point out that population mixing effects cause transitions from long-lived 3s to 3p sublevel with corresponding changes in Hα radiation intensities. Discussed effects may influence to results of Doppler-shift spectroscopy measurements of the neutral beam parameters such as species and impurities content and neutralizing efficiency.

2.
Rev Sci Instrum ; 85(2): 02B129, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593569

RESUMEN

The paper reviews the results of development of steady-state arc-discharge plasma generator with directly heated LaB6 cathode. This arc-discharge plasma generator produces a plasma jet which is to be converted into an atomic one after recombination on a metallic plate. The plate is electrically biased relative to the plasma in order to control the atom energies. Such an intensive jet of hydrogen atoms can be used in negative ion sources for effective production of negative ions on a cesiated surface of plasma grid. All elements of the plasma generator have an augmented water cooling to operate in long pulse mode or in steady state. The thermo-mechanical stresses and deformations of the most critical elements of the plasma generator were determined by simulations. Magnetic field inside the discharge chamber was optimized to reduce the local power loads. The first tests of the steady-state arc plasma generator prototype have performed in long-pulse mode.

3.
Rev Sci Instrum ; 83(2): 02B707, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380312

RESUMEN

The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35°. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.

4.
Rev Sci Instrum ; 81(2): 02B104, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20192411

RESUMEN

The status and the executing modernization of RUssian Diagnostic Injector (RUDI) are described. The ion source consists of arc plasma emitter and multiaperture four-electrode ion optical system. The present ion optical system with round beamlets is to be replaced by new slit apertures system for the reducing beam angular divergence in one direction. Due to enlarged dimensions and transparency of new ion optical system the extracted ion beam current will be by 50% increased. For the extension of beam pulse duration from 4 s to 8-10 s an optimized metal-ceramic arc-discharge channel is introduced. In the paper, the optical measurements results of beam parameters, including the profile of species distribution, scanned by custom-built multichannel spectroscope, are also presented.

5.
Ukr Biokhim Zh (1978) ; 63(1): 60-6, 1991.
Artículo en Ruso | MEDLINE | ID: mdl-2028518

RESUMEN

A simple method to estimate phospholipids is elaborated. This method is based on determination of optical density of phospholipid-molybdate complexes in chloroform. The method is used for the quantitative determination of phospholipids in biomembranes, liposomes and blood serum without their preliminary extraction, as well as in chloroform, methanol and chloroform-methanol solutions. It is also modified for the phospholipids determination in chromatographic fractions on silufol plates.


Asunto(s)
Fosfolípidos/análisis , Animales , Cloroformo , Liposomas/análisis , Lípidos de la Membrana/análisis , Metanol , Fosfolípidos/sangre , Ratas , Espectrofotometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...