Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.077
Filtrar
1.
J Formos Med Assoc ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38724340

RESUMEN

BACKGROUND: Current guidelines advocate for maintaining BP level below 180/105 mmHg during EVT, determining the safe lower boundary remains primarily consensus-driven by experts. This study aims to delve into the correlation between various targets of lower boundary for systolic and diastolic BP (SBP and DBP) during EVT and 3-month functional outcomes. METHODS: A cohort study was conducted across two EVT-capable centers, enrolling patients with large artery occlusion undergoing EVT within 8 h of stroke onset. Mean BP values during EVT were meticulously recorded, and logistic regression models were utilized to evaluate the correlation between outcomes and diverse lower boundary targets for SBP and DBP. Additionally, logistic regression models investigated the relationship between periprocedural BP variability and subsequent outcomes. RESULTS: Among the 201 patients included, having a SBP higher than 130 or 140 mmHg showed an independent association with increased good functional outcomes at 3 months (adjusted odds ratio, aOR 2.80, 95% Cis, 1.26-6.39 for 140 mmHg; aOR 2.34, 95% Cis, 1.03-5.56 for 130 mmHg). Additionally, an SBP exceeding 130 mmHg was correlated with decreased 3-month mortality (aOR, 0.24, 95% CI 0.07-0.74). No significant relationship was observed between DBP and functional outcomes. Patients with higher periprocedural SBP coefficient variance exhibited a decreased rate of good functional outcomes at 3 months (aOR, 0.42, 95% CI, 0.18-0.96). CONCLUSIONS: A SBP range above 130-140 mmHg could potentially serve as a safe lower boundary during EVT, while minimizing BP fluctuations may correlate with improved post-EVT functional outcomes.

2.
Front Med (Lausanne) ; 11: 1188629, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38737765

RESUMEN

Introduction: Mifepristone-misoprostol treatment for medical abortion and miscarriage are safe and effective. This study aimed to assess clinical factors associated with subsequent surgical intervention after medical termination of early viable or non-viable pregnancy. Methods: This retrospective, single-center study included women who underwent medical abortion at Taipei Medical University between January 2010 and December 2019. A total of 1,561 subjects, with 1,080 viable and 481 non-viable pregnancies, who were treated with oral mifepristone 600 mg followed by misoprostol 600 mg 48 h later were included. Data of all pregnancies and medical termination of pregnancy were evaluated using regression analysis. The main outcome was successful termination of pregnancy. Results: The success rate of medical abortion was comparable in women with viable and non-viable (92.13% vs. 92.93%) pregnancies. Besides retained tissue, more existing pregnancies with ultrasonographic findings were found in the non-viable pregnancy group than in the viable pregnancy group (29.4% vs. 14.1%, p = 0.011). Multivariate analysis showed that previous delivery was an independent risk factor for failed medical abortion among all included cases. In women with viable pregnancy, longer gestational age [adjusted odds ratio (aOR): 1.483, 95% confidence interval (CI): 1.224-1.797, p < 0.001] and previous Cesarean delivery (aOR: 2.177, 95% CI: 1.167-40.62, p = 0.014) were independent risk factors for failed medical abortion. Number of Cesarean deliveries (aOR: 1.448, 95% CI: 1.029-2.039, p = 0.034) was an independent risk factor for failed medication abortion in women with non-viable pregnancies. Conclusion: This is the first cohort study to identify risk factors for subsequent surgical intervention in women with viable or non-viable pregnancies who had undergone early medically induced abortions. The success rate of medical abortion is comparable in women with viable and non-viable pregnancies. Previous delivery is an independent risk factor for failed medical abortion. Clinical follow-up may be necessary for women who are at risk of subsequent surgical intervention.

3.
Res Sq ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38766077

RESUMEN

Purpose Breast cancer surgery, even with reconstruction, can make it difficult for patients to find a bra that fits properly, is comfortable, and meets their aesthetic standards. We explored breast cancer survivors' experiences with bras over time to identify preferences, needs, and challenges throughout their journeys. Methods Fifteen women who had undergone mastectomy and either delayed or immediate breast reconstruction participated in the study. Focus groups were conducted to explore the participants' current experiences with bras. They were also prompted to recall their experiences before mastectomy and immediately after reconstruction. The discussion included bra materials, styles, construction techniques, color, quality, and price. Results Thematic analysis generated five major themes: "Sense of normalcy and personal well-being," "Struggles immediately following surgery," "Transitions in bra experiences and preference," "Practicality with outfit," and "Association between quality and price". Conclusion Breast cancer survivors' well-being is linked to their experiences with bras and the associated purchasing process, and bra needs change throughout the cancer care journey. Survivors' experiences with bras impact their sense of normalcy and sense of control over significant bodily changes arising from cancer and its treatment. The study underscores the importance of future research on examining the relationship between survivors' quality of life and garment experiences, including factors such as color choices, closure options, and adjustability for individual needs.

4.
Anal Chim Acta ; 1309: 342671, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38772664

RESUMEN

Electrochemical biosensors, known for their low cost, sensitivity, selectivity, and miniaturization capabilities, are ideal for point-of-care devices. The magnetic metal-organic framework (MMOF), synthesized using the in-situ growth method, consists of ferric salt, magnetic nanoparticles, histidine, and benzene tetracarboxylic acid. MMOF was sequentially modified with aptamer-biotin and streptavidin-horseradish peroxidase, serving as a detector for spike protein and a transducer converting electrochemical signals using H2O2-hydroquinone on a screen-printed electrode. MMOF facilitates easy washing and homogeneous deposition on the working electrode with a magnet, enhancing sensitivity and reducing noise. The physical and electrochemical properties of the modified MMOFs were thoroughly characterized using various analytical techniques. The aptasensors' performance achieved a detection limit of 6 pM for voltammetry and 5.12 pM for impedance spectroscopy in human serum samples. This cost-effective, portable MMOF platform is suitable for rapid point-of-care testing for SARS-CoV-2 spike proteins.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Límite de Detección , Estructuras Metalorgánicas , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Estructuras Metalorgánicas/química , Glicoproteína de la Espiga del Coronavirus/análisis , Aptámeros de Nucleótidos/química , Humanos , Técnicas Biosensibles/métodos , SARS-CoV-2/aislamiento & purificación , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , COVID-19/diagnóstico , COVID-19/virología , Nanopartículas de Magnetita/química , Electrodos
5.
Nutrients ; 16(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732503

RESUMEN

(1) Background: This study investigated the effects of caffeinated chewing gum on the basketball-specific performance of trained basketball players. A double-blind, randomized crossover design was employed. (2) Methods: Fifteen participants (age: 20.9 ± 1.0 years; height: 180.9 ± 5.4 cm; mass: 77.2 ± 7.5 kg; training age: 8.2 ± 0.3 years) were recruited and divided into a caffeine trial (CAF) and placebo trial (PL). The participants in the CAF trial chewed gum containing 3 mg/kg of caffeine for 10 min, while those in the PL trial chewed a placebo gum without caffeine. Following a 15 min rest, all the participants completed basketball-specific performance tests. (3) Results: The free throw accuracy for the CAF trial was significantly higher than that for the PL trial (CAF: 79.0 ± 4.31%; PL: 73.0 ± 9.16%; p = 0.012; Cohen's d = 0.94). Additionally, the CAF trial demonstrated significantly better performance in the 20 m segmented dash (CAF: 2.94 ± 1.12 s; PL: 3.13 ± 0.10 s; p < 0.001; Cohen's d =1.8) and squats (p < 0.05), and exhibited lower fatigue indexes (CAF: 3.6 ± 1.6%; PL: 5.2 ± 1.6%; p = 0.009; Cohen's d =1.0). (4) Conclusions: These findings suggest that chewing gum containing 3 mg/kg of caffeine offers moderate-to-large improvements in key performance aspects relevant to professionally trained basketball players.


Asunto(s)
Rendimiento Atlético , Baloncesto , Cafeína , Goma de Mascar , Estudios Cruzados , Humanos , Baloncesto/fisiología , Método Doble Ciego , Cafeína/administración & dosificación , Rendimiento Atlético/fisiología , Adulto Joven , Masculino , Adulto , Atletas , Estimulantes del Sistema Nervioso Central/administración & dosificación , Estimulantes del Sistema Nervioso Central/farmacología
6.
PLoS One ; 19(5): e0303431, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38723011

RESUMEN

The immune checkpoint proteins were reported to involve to host resistance to Mycobacteria tuberculosis (Mtb). Here, we evaluated 11 single nucleotide polymorphisms (SNPs) in PDCD1, CTLA4, and HAVCR2 genes between participants with and without TB infection. Genomic DNA isolated from 285 patients with TB and 270 controls without TB infection were used to perform the genotyping assay. Odds ratios were used to characterize the association of 11 SNPs with TB risk. In this study, the various genotypes of the 11 SNPs did not differ significantly in frequency between the non-TB and TB groups. When patients were stratified by sex, however, men differed significantly from women in genotype frequencies at HAVCR2 rs13170556. Odds ratios indicated that rs2227982, rs13170556, rs231775, and rs231779 were sex-specifically associated with TB risk. In addition, the combinations of rs2227982/rs13170556 GA/TC in men and the A-C-C haplotype of rs231775-rs231777-rs231779 in women were significantly associated with TB risk. Our results indicate that rs2227982 in PDCD1 and rs13170556 in HAVCR2 are associated with increased TB susceptibility in men and that the CTLA4 haplotype appears protective against TB in women.


Asunto(s)
Antígeno CTLA-4 , Predisposición Genética a la Enfermedad , Receptor 2 Celular del Virus de la Hepatitis A , Polimorfismo de Nucleótido Simple , Receptor de Muerte Celular Programada 1 , Tuberculosis , Humanos , Masculino , Femenino , Antígeno CTLA-4/genética , Receptor de Muerte Celular Programada 1/genética , Receptor 2 Celular del Virus de la Hepatitis A/genética , Tuberculosis/genética , Adulto , Persona de Mediana Edad , Haplotipos , Estudios de Casos y Controles , Genotipo
7.
Artículo en Inglés | MEDLINE | ID: mdl-38700794

RESUMEN

Type 2 diabetes mellitus (T2DM) is a metabolic disease. Diabetes increases the risk of benign prostatic hyperplasia (BPH). Capsaicin is extracted from chili peppers and possesses many pharmacological properties, including anti-diabetic, pain-relieving, and anti-cancer properties. This study aimed to investigate the effects of capsaicin on glucose metabolism and prostate growth in T2DM mice and uncover the related mechanisms. Mice model of diabetes was established by administering a high-fat diet and streptozotocin. Oral administration of capsaicin for 2 weeks inhibited prostate growth in testosterone propionate (TP)-treated mice. Furthermore, oral administration of capsaicin (5 mg/kg) for 2 weeks decreased fasting blood glucose, prostate weight, and prostate index in diabetic and TP-DM mice. Histopathological alterations were measured using hematoxylin & eosin (H&E) staining. The protein expression of 5α-reductase type II, androgen receptor (AR), and prostate-specific antigen (PSA) were upregulated in diabetic and TP-DM mice, but capsaicin reversed these effects. Capsaicin decreased the protein expression of p-AKT, insulin-like growth factor-1 (IGF-1), IGF-1R, and the receptor for advanced glycation end products (RAGE) in diabetic and TP-DM mice. Capsaicin also regulated epithelial-mesenchymal transition (EMT) and modulated the expression of fibrosis-related proteins, including E-cadherin, N-cadherin, vimentin, fibronectin, α-SMA, TGFBR2, TGF-ß1, and p-Smad in TP-DM mice. In this study, capsaicin alleviated diabetic prostate growth by attenuating EMT. Mechanistically, capsaicin affected EMT by regulating RAGE/IGF-1/AKT, AR, and TGF-ß/Smad signalling pathways. These results provide with new therapeutic approach for treating T2DM or T2DM-induced prostate growth.

9.
Heliyon ; 10(7): e27948, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38571643

RESUMEN

Ischemic stroke is a significant burden on human health worldwide. Carotid Atherosclerosis stenosis plays an important role in the comprehensive assessment and prevention of ischemic stroke patients. High-resolution vessel wall magnetic resonance imaging has emerged as a successful technique for assessing carotid atherosclerosis stenosis. This advanced imaging modality has shown promise in effectively displaying a wide range of characteristics associated with the condition, leading to a comprehensive evaluation. High-resolution vessel wall magnetic resonance imaging not only enables a comprehensive evaluation of the instability of carotid atherosclerosis stenosis plaques but also provides valuable information for understanding the pathogenesis and predicting the prognosis of ischemic stroke patients. The purpose of this article is to review the application of high-resolution magnetic resonance imaging in ischemic stroke and carotid atherosclerotic stenosis.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38619943

RESUMEN

Extracting data insights and generating visual data stories from tabular data are critical parts of data analysis. However, most existing studies primarily focus on tabular data stored as flat tables, typically without leveraging the relations between cells in the headers of hierarchical tables. When properly used, rich table headers can enable the extraction of many additional data stories. To assist analysts in visual data storytelling, an approach is needed to organize these data insights efficiently. In this work, we propose CoInsight, a system to facilitate visual storytelling for hierarchical tables by connecting insights. CoInsight extracts data insights from hierarchical tables and builds insight relations according to the structure of table headers. It further visualizes related data insights using a nested graph with edge bundling. We evaluate the CoInsight system through a usage scenario and a user experiment. The results demonstrate the utility and usability of CoInsight for converting data insights in hierarchical tables into visual data stories.

11.
Biomed Opt Express ; 15(4): 2708-2718, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38633062

RESUMEN

The two-photon all-optical physiology system has attracted great interest in deciphering neuronal circuits in vivo, benefiting from its advantages in recording and modulating neuronal activities at single neuron resolutions. However, the interference, or crosstalk, between the imaging and photostimulation beams introduces a significant challenge and may impede the future application of voltage indicators in two-photon all-optical physiology system. Here, we propose the time multiplexed excitation method to distinguish signals from neuronal activities and crosstalks from photostimulation. In our system, the laser pulses of the imaging beam and photostimulation beam are synchronized, and a time delay is introduced into these pulses to separate the fluorescence signal generated by these two beams. We demonstrate the efficacy of our system in eliminating crosstalk signals from photostimulation and evaluate its influence on both genetically encoded calcium indicators (GECIs) and genetically encoded voltage indicators (GEVIs) through in vivo experiments.

12.
Med Image Anal ; 95: 103180, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38657423

RESUMEN

The high noise level of dynamic Positron Emission Tomography (PET) images degrades the quality of parametric images. In this study, we aim to improve the quality and quantitative accuracy of Ki images by utilizing deep learning techniques to reduce the noise in dynamic PET images. We propose a novel denoising technique, Population-based Deep Image Prior (PDIP), which integrates population-based prior information into the optimization process of Deep Image Prior (DIP). Specifically, the population-based prior image is generated from a supervised denoising model that is trained on a prompts-matched static PET dataset comprising 100 clinical studies. The 3D U-Net architecture is employed for both the supervised model and the following DIP optimization process. We evaluated the efficacy of PDIP for noise reduction in 25%-count and 100%-count dynamic PET images from 23 patients by comparing with two other baseline techniques: the Prompts-matched Supervised model (PS) and a conditional DIP (CDIP) model that employs the mean static PET image as the prior. Both the PS and CDIP models show effective noise reduction but result in smoothing and removal of small lesions. In addition, the utilization of a single static image as the prior in the CDIP model also introduces a similar tracer distribution to the denoised dynamic frames, leading to lower Ki in general as well as incorrect Ki in the descending aorta. By contrast, as the proposed PDIP model utilizes intrinsic image features from the dynamic dataset and a large clinical static dataset, it not only achieves comparable noise reduction as the supervised and CDIP models but also improves lesion Ki predictions.

13.
Artículo en Inglés | MEDLINE | ID: mdl-38602002

RESUMEN

Adhesion molecules play critical roles in maintaining the structural integrity of the airway epithelium in airways under stress. Previously, we reported that catenin alpha-like 1 (CTNNAL1) is downregulated in an asthma animal model and upregulated at the edge of human bronchial epithelial cells (HBECs) after ozone stress. In this work, we explore the potential role of CTNNAL1 in the structural adhesion of HBECs and its possible mechanism. We construct a CTNNAL1 ‒/‒ mouse model with CTNNAL1-RNAi recombinant adeno-associated virus (AAV) in the lung and a CTNNAL1-silencing cell line stably transfected with CTNNAL1-siRNA recombinant plasmids. Hematoxylin and eosin (HE) staining reveals that CTNNAL1 ‒/‒ mice have denuded epithelial cells and structural damage to the airway. Silencing of CTNNAL1 in HBECs inhibits cell proliferation and weakens extracellular matrix adhesion and intercellular adhesion, possibly through the action of the cytoskeleton. We also find that the expressions of the structural adhesion-related molecules E-cadherin, integrin ß1, and integrin ß4 are significantly decreased in ozone-treated cells than in vector control cells. In addition, our results show that the expression levels of RhoA/ROCK1 are decreased after CTNNAL1 silencing. Treatment with Y27632, a ROCK inhibitor, abolished the expressions of adhesion molecules induced by ozone in CTNNAL1-overexpressing HBECs. Overall, the findings of the present study suggest that CTNNAL1 plays a critical role in maintaining the structural integrity of the airway epithelium under ozone challenge, and is associated with epithelial cytoskeleton dynamics and the expressions of adhesion-related molecules via the RhoA/ROCK1 pathway.

14.
IEEE Trans Med Imaging ; PP2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38578853

RESUMEN

Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomography (CT) is commonly used to derive attenuation maps (µ-maps) for attenuation correction (AC) of cardiac SPECT, but it will introduce additional radiation exposure and SPECT-CT misalignments. Although various methods have been developed to solely focus on LD denoising, LV reconstruction, or CT-free AC in SPECT, the solution for simultaneously addressing these tasks remains challenging and under-explored. Furthermore, it is essential to explore the potential of fusing cross-domain and cross-modality information across these interrelated tasks to further enhance the accuracy of each task. Thus, we propose a Dual-Domain Coarse-to-Fine Progressive Network (DuDoCFNet), a multi-task learning method for simultaneous LD denoising, LV reconstruction, and CT-free µ-map generation of cardiac SPECT. Paired dual-domain networks in DuDoCFNet are cascaded using a multi-layer fusion mechanism for cross-domain and cross-modality feature fusion. Two-stage progressive learning strategies are applied in both projection and image domains to achieve coarse-to-fine estimations of SPECT projections and CT-derived µ-maps. Our experiments demonstrate DuDoCFNet's superior accuracy in estimating projections, generating µ-maps, and AC reconstructions compared to existing single- or multi-task learning methods, under various iterations and LD levels. The source code of this work is available at https://github.com/XiongchaoChen/DuDoCFNet-MultiTask.

15.
Medicina (Kaunas) ; 60(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38674293

RESUMEN

Background and Objectives: The Taiwan Triage and Acuity Scale (TTAS) is reliable for triaging patients in emergency departments in Taiwan; however, most triage decisions are still based on chief complaints. The reverse-shock index (SI) multiplied by the simplified motor score (rSI-sMS) is a more comprehensive approach to triage that combines the SI and a modified consciousness assessment. We investigated the combination of the TTAS and rSI-sMS for triage compared with either parameter alone as well as the SI and modified SI. Materials and Methods: We analyzed 13,144 patients with trauma from the Taipei Tzu Chi Trauma Database. We investigated the prioritization performance of the TTAS, rSI-sMS, and their combination. A subgroup analysis was performed to evaluate the trends in all clinical outcomes for different rSI-sMS values. The sensitivity and specificity of rSI-sMS were investigated at a cutoff value of 4 (based on previous study and the highest score of the Youden Index) in predicting injury severity clinical outcomes under the TTAS system were also investigated. Results: Compared with patients in triage level III, those in triage levels I and II had higher odds ratios for major injury (as indicated by revised trauma score < 7 and injury severity score [ISS] ≥ 16), intensive care unit (ICU) admission, prolonged ICU stay (≥14 days), prolonged hospital stay (≥30 days), and mortality. In all three triage levels, the rSI-sMS < 4 group had severe injury and worse outcomes than the rSI-sMS ≥ 4 group. The TTAS and rSI-sMS had higher area under the receiver operating characteristic curves (AUROCs) for mortality, ICU admission, prolonged ICU stay, and prolonged hospital stay than the SI and modified SI. The combination of the TTAS and rSI-sMS had the highest AUROC for all clinical outcomes. The prediction performance of rSI-sMS < 4 for major injury (ISS ≥ 16) exhibited 81.49% specificity in triage levels I and II and 87.6% specificity in triage level III. The specificity for mortality was 79.2% in triage levels I and II and 87.4% in triage level III. Conclusions: The combination of rSI-sMS and the TTAS yielded superior prioritization performance to TTAS alone. The integration of rSI-sMS and TTAS effectively enhances the efficiency and accuracy of identifying trauma patients at a high risk of mortality.


Asunto(s)
Triaje , Heridas y Lesiones , Humanos , Triaje/métodos , Triaje/normas , Masculino , Femenino , Taiwán/epidemiología , Persona de Mediana Edad , Adulto , Heridas y Lesiones/mortalidad , Anciano , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Puntaje de Gravedad del Traumatismo , Sensibilidad y Especificidad , Índices de Gravedad del Trauma , Choque/mortalidad , Choque/diagnóstico , Tiempo de Internación/estadística & datos numéricos
16.
Int J Surg ; 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38549224

RESUMEN

INTRODUCTION: Septic cardiomyopathy is a sepsis-mediated cardiovascular complication with severe microcirculatory malperfusion. Emerging evidence has highlighted the protective effects of pulsatile flow in case of microcirculatory disturbance, yet the underlying mechanisms are still elusive. The objective of this study was to investigate the mechanisms of N6-methyladenosine (m6A) modification in the alleviation of septic cardiomyopathy associated with extracorporeal membrane oxygenation (ECMO)-generated pulsatile flow. METHODS: Rat model with septic cardiomyopathy was established and was supported under ECMO either with pulsatile or non-pulsatile flow. Peripheral perfusion index (PPI) and cardiac function parameters were measured using ultrasonography. Dot blot assay was applied to examine the m6A level, while qRT-PCR, Western blot, immunofluorescence, and immunohistochemistry were used to measure the expressions of related genes. RNA immunoprecipitation assay was performed to validate the interaction between molecules. RESULTS: The ECMO-generated pulsatile flow significantly elevates microcirculatory PPI, improves myocardial function, protects the endothelium, and prolongs survival in rat models with septic cardiomyopathy. The pulsatile flow mediates the METTL14-mediated m6A modification to zonula occludens- (ZO-) 1 mRNA which stabilizes the ZO-1 mRNA depending on the presence of YTHDF2. The pulsatile flow suppresses the PI3K-Akt signaling pathway, of which the downstream molecule Foxo1, a negative transcription factor of METTL14, binds to the METTL14 promoter and inhibits the METTL14-induced m6A modification. CONCLUSION: The ECMO-generated pulsatile flow increases METTL14-induced m6A modification in ZO-1 and attenuates the progression of septic cardiomyopathy, suggesting that pulsatility might be a new therapeutic strategy in septic cardiomyopathy by alleviating microcirculatory disturbance.

17.
Br J Ophthalmol ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38514167

RESUMEN

BACKGROUND: To develop and assess the usability of a smartphone-based visual acuity (VA) test with an automatic distance calibration (ADC) function, the iOS version of WHOeyes. METHODS: The WHOeyes was an upgraded version with a distinct feature of ADC of an existing validated VA testing app called V@home. Three groups of Chinese participants with different ages (≤20, 20-40, >40 years) were recruited for distance and near VA testing using both an Early Treatment Diabetic Retinopathy Study (ETDRS) chart and the WHOeyes. The ADC function would determine the testing distance. Infrared rangefinder was used to determine the testing distance for the ETDRS, and actual testing distance for the WHOeyes. A questionnaire-based interview was administered to assess the satisfaction. RESULTS: The actual testing distance determined by the WHOeyes ADC showed an overall good agreement with the desired testing distance in all three age groups (p>0.50). Regarding the distance and near VA testing, the accuracy of WHOeyes was equivalent to ETDRS. The mean difference between the WHOeyes and ETDRS ranged from -0.084 to 0.012 logMAR, and the quadratic weighted kappa (QWK) values were >0.75 across all groups. The test-retest reliability of WHOeyes was high for both near and distance VA, with a mean difference ranging from -0.040 to 0.004 logMAR and QWK all >0.85. The questionnaire revealed an excellent user experience and acceptance of WHOeyes. CONCLUSIONS: WHOeyes could provide accurate measurement of the testing distance as well as the distance and near VA when compared to the gold standard ETDRS chart.

18.
Heliyon ; 10(6): e27582, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38496848

RESUMEN

The proximal convoluted tubule (PCT) of the kidney is a crucial functional segment responsible for reabsorption, secretion, and the maintenance of electrolyte and water balance within the renal tubule. However, there is a lack of a well-defined endogenous transgenic line for studying PCT morphogenesis. By analyzing single-cell transcriptome data from the adult zebrafish kidney, we have identified the expression of odd-skipped-related 2 (osr2, which encodes an odd-skipped zinc-finger transcription factor) in the PCT. To gain insight into the role of osr2 in PCT morphogenesis, we have generated a transgenic zebrafish line Tg(osr2:EGFP), expressing enhanced green fluorescent protein (EGFP). The EGFP expression pattern closely mirrors that of endogenous Osr2, faithfully recapitulating its native expression profile. During kidney development, we can use EGFP to track PCT development, which is also preserved in adult zebrafish. Additionally, osr2:EGFP-labeled zebrafish PCT fragments displayed short lengths with infrequent overlap, rendering them conducive for nephrons counting. The generation of Tg(osr2:EGFP) transgenic line is accompanied by simultaneous disruption of osr2 activity. Importantly, our findings demonstrate that osr2 inactivation had no discernible impact on the development and regeneration of Tg(osr2:EGFP) zebrafish nephrons. Overall, the establishment of this transgenic zebrafish line offers a valuable tool for both genetic and chemical analysis of PCT.

19.
Psych J ; 13(2): 176-189, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38298170

RESUMEN

The high incidence of adolescent depression has become the focus of social and academic attention. Exercise is an important method to improve adolescent depression, but its intervention effect is still controversial. This study first compares and analyzes the relevant studies at home and abroad and finds that exercise prescription in adolescent depression intervention is not accurate enough. A meta-analysis was conducted to develop a precise exercise intervention strategy for adolescent depression. Firstly, this thesis identified how to optimize five elements (exercise intensity, exercise frequency, exercise time, exercise cycle, and exercise type) of exercise prescription to improve depression in adolescents. This is the problem. Furthermore, the concept of "precision exercise" was proposed, and a precision exercise intervention strategy (moderate-intensity aerobic exercise for 8-10 weeks, 3 times/week, 45-50 min/time) was constructed to improve adolescent depression. This paper also presents research that strengthens the cross-sectional research and empirical research on adolescent depression and establishes a precision exercise prescription database for adolescent depression in China. In conclusion, this study not only puts forward the concept of "precision exercise" but also constructs a precision exercise intervention strategy for adolescent depression, which has important theoretical and practical significance for improving the high incidence of adolescent depression.


Asunto(s)
Depresión , Terapia por Ejercicio , Humanos , Adolescente , Estudios Transversales , Terapia por Ejercicio/métodos , Ejercicio Físico , China
20.
Analyst ; 149(8): 2236-2243, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38414418

RESUMEN

Cadmium poisoning is a chronic accumulation process, and long-term drinking of even low cadmium content water will cause kidney damage, so an ultra-low detection limit is particularly important. However, at the present stage, the traditional detection method cannot reach a sufficiently low detection limit, the response time is too long, and the cost of detection is very high, so that real-time measurement cannot be realized. Therefore, the traditional cadmium ion detection method has a slow response and an insufficient detection limit. This paper presents a fiber optic cadmium ion sensor functionalized based on an Fe3O4@SiO2@CS magnetic ion imprinting polymer (M-IIP). The sensor is based on the coupling characteristics of the optical microfiber coupler (OMC) cone region to achieve a highly sensitive response to the change in the cadmium ion concentration. M-IIP materials were prepared by surface imprinting polymerization to achieve low cross-sensitivity and thus improve the detection limit of the sensor. The results show that the developed fiber sensor has high specificity and a rapid response to cadmium ions. The experimental limit of detection (LOD) reached 0.051 nM within 0-1 µM with a response time of less than 50 s. Moreover, the proposed fiber cadmium ion sensor exhibits excellent performance in terms of sensitivity, stability, repeatability and biocompatibility.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA