RESUMEN
Testicular torsion is a critical urologic condition for which testicular detorsion surgery is considered irreplaceable as well as the golden method of reversal. However, the surgical treatment is equivalent to a blood reperfusion process, and no specific drugs are available to treat blood reperfusion injuries. Salidroside (SAL) is one of the main effective substances in rhodiola, which has been shown to have antioxidant and antiapoptosis activities. This study was designed to determine whether SAL exerted a protective effect on testicular ischemia-reperfusion (I/R) injury. In this study, the I/R injury model of the testes and reoxygenation (OGD/R) model were used for verification, and SAL was administered at doses of 100 mg/kg and 0.05 mmol/L, respectively. After the experiments, the testicular tissue and TM4 Sertoli cells were collected for histopathologic and biochemical analyses. The results revealed that SAL improves the structure of testicular tissue and regulates the oxidation-antioxidation system. To further understand the molecular mechanisms of SAL in treating testicular I/R injuries, transcriptomics and metabonomics analyses were integrated. The results show that the Nfr2/HO-1/GPX4/ferroptosis signaling pathway is enriched significantly, indicating that it may be the main regulatory pathway for SAL in the treatment of testicular I/R injuries. Thereafter, transfection with Nrf2 plasmid-liposome was used to reverse verify that the Nfr2/HO-1/GPX4/ferroptosis signaling pathway was the main pathway for SAL anti-testicular I/R injury treatment. Thus, it is suggested that SAL can protect against testicular I/R injuries by regulating the Nfr2/HO-1/GPX4 signaling pathway to inhibit ferroptosis and that SAL may be a potential drug for the treatment of testicular I/R injuries.
RESUMEN
AIM: To compare the consistency of two autorefractors (Tianle RM-9000 and Topcon KR-800) for school-age myopia children, and to provide a basis for largescale data analysis and comparison. METHODS: The refractive error in 909 subjects (age 4-18y) were measured using both autorefractors without cycloplegia. The data were analyzed using Fourier decomposition and the correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman limits of agreement (LoA) for each parameter were calculated. RESULTS: There was a strong correlation between the spherical equivalent (SE), sphere diopter (DS), and cylinder diopter (DC) readings of the Tianle RM-9000 and those of the Topcon KR-800, with correlation coefficient values of 0.98, 0.98 and 0.83 and ICC values of 0.99, 0.99 and 0.93, respectively. However, the correlation coefficients and ICC values of J0 and J45 were unreliable (R=-0.004, -0.034; both ICC<0.10). Bland-Altman analysis revealed that SE, DS, and DC measured by the Tianle RM-9000 were significantly biased toward myopia compared with the Topcon KR-800, and the mean differences were -0.072, -0.026, -0.091 D, respectively (all P<0.01). The minimum absolute value of the difference within the 95% LoA for SE, DS, and DC was 0.63 D, 0.50 D, 0.62 D, respectively; all these values were in the clinically acceptable range. For J0 and J45, the mean differences were close to zero (P=0.43, 0.84); however, the 95% LoA were relatively wide (J0 SD: 0.53; 95%CI: -1.00, 1.10; J45 SD: 0.52; 95%CI: -1.00, 1.00). CONCLUSION: The two autorefractors are consistent with each other, as the differences in SE, DS, and DC were within the clinically acceptable range. Readers can compare the data measured by either device in different studies and use the two devices in the same study to generate a dataset that can be analyzed together. However, the J0 and J45 vectors are unreliable and should not be used to assess astigmatism.
RESUMEN
One novel cadmium(II)-coordination polymer [Cd3L2(datrz)(H2O)3] (CP 1) is controllably synthesized by surmising the astute combination of semi-rigid tricarboxylate acid 4-(2',3'-dicarboxylphenoxy) benzoic acid (H3L) and auxiliary ligand 3,5-diamino-1,2,4-triazole (datrz). Structure analysis shows that CP 1 has a two-dimensional (2D) layer structure with a 5-nodal (43) (44·62) (45·64·8) (45·6) (47·66·82) topology. Further investigations reveal that CP 1 shows superordinary water stability and good thermal stability. The fluorescent explorations suggest that the as-synthesized CP 1 could emit blue light centered at 485 nm, attributing to ligand-based emission. In terms of sensing investigations, CP 1 could act as a fluorescent sensor for detecting hypochlorite (ClO-) and acetylacetone (acac) through fluorescence turn-off process in aqueous solution, and the detection limit could reach 0.18 µM and 0.056 µM, respectively. Further research reveals that it is more likely the N-H···O-Cl hydrogen bonds between -NH2 groups of the triazole ligands and O atoms of ClO- plays the key role in the system, which may serve as a bridge for the energy transfer, leading to fluorescence quenching of the chemosensor. While the photoinduced electron transfer (PET) combined with inner filter effect (IFT) should be responsible for the turn-off fluorescence of CP 1 triggered by acac.
Asunto(s)
Ácido Hipocloroso , Agua , Agua/química , Cadmio/análisis , LigandosRESUMEN
AIM: To analyse the association of sleep quality with myopia under different genetic risk (GR) levels. METHODS: A cross-sectional survey of students aged 9-14y in Wenzhou, China, was conducted. Refraction without cycloplegia and ocular parameters were measured. Sleep quality was assessed with the Pittsburgh Sleep Quality Index (PSQI). Seventeen single nucleotide polymorphisms (SNPs) were replicated by association analysis and used to compute the GR score (GRS). Possible confounders were assessed by a questionnaire that collected information about the children and their parents. Generalized linear models were used to analyse the sleep quality, the GR, and their interaction effects on the risk of myopia. RESULTS: Out of 1354 children included in this study, 353 (26.07%) had sleep disturbances. The GRS ranged from 4.49 to 12.89 with a mean of 7.74±1.23, and the participants were divided into a low GR group, a moderate GR group and a high GR group according to the GRS quartile. In the generalized linear model, the children with sleep disturbances and high GR had a higher risk of myopia than those without sleep disturbances and with low GR (OR=1.59, 95%CI: 1.12-2.25; OR=1.88, 95%CI: 1.23-2.88, respectively). Compared to those with low GR and SDs, children with high GR with or without SDs had a higher risk of myopia (OR=4.88, 95%CI: 2.03-11.71; OR=1.70, 95%CI: 1.06-2.72, respectively). CONCLUSION: The prevalence of sleep disturbances in elementary school students in Wenzhou was 26.07%. There is a significant interaction between sleep disturbances and a high GR of myopia, suggesting that a high GR of myopia may increase children's sensitivity to sleep disturbances. This study indicates that children with a high GR of myopia need to achieve adequate sleep duration and excellent sleep quality.
RESUMEN
The electrochemical redox of ferulic acid (FA) was investigated systematically by cyclic voltammetry (CV) with a poly(diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode (PDDA-G/GCE) as a working electrode. A simple and sensitive differential pulse voltammetry (DPV) technique was proposed for the direct quantitative determination of FA in Angelica sinensis and spiked human urine samples for the first time. The dependence of the intensities of currents and potentials on nature of the supporting electrolyte, pH, scan rate, and concentration was investigated. Under optimal conditions, the proposed sensor exhibited excellent electrochemical sensitivity to FA, and the oxidation peak current was proportional to FA concentration in the range of 8.95 × 10(-8) M ~5.29 × 10(-5) M, with a relatively low detection limit of 4.42 × 10(-8) M. This fabricated sensor also displayed acceptable reproducibility, long-term stability, and high selectivity with negligible interferences from common interfering species. Besides, it was applied to detect FA in Angelica sinensis and biological samples with satisfactory results, making it a potential alternative tool for the quantitative detection of FA in pharmaceutical analysis.