Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 453
Filtrar
1.
Front Psychol ; 15: 1423540, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045443

RESUMEN

In today's volatile, uncertain, complex, and ambiguous (VUCA) work environments, mitigating employee burnout and turnover has become a critical concern. The enhancement of employee engagement stands out as a pivotal focus in corporate human resource management. Coaching leadership focuses on the encouragement and inspiration of employees, which can effectively stimulate the internal potential of employees, enhance work ability and enhance engagement. However, previous research on the relationship between coaching leadership style and employee engagement are limited, thus obscures the essential function in enterprise development and core competitiveness. The research collected 402 valid responses from MBA and EMBA students at the School of Business, and examines the effect of coaching leadership on employee engagement. Results indicate that coaching leadership significantly enhances multiple facets of employee engagement, including vigor, devotion, and absorption. Crucially, organizational self-esteem emerges as a mediating factor, while learning goal orientation strengthens the positive effects of coaching leadership. This research sheds light on the nuanced dynamics of effective leadership in contemporary workplaces, also it underscores the need for more nuanced, industry-specific analyses and broader exploration of moderating variables. Ultimately, the insights garnered hold profound implications for leadership training, human resource strategies, and performance metrics, emphasizing a more integrative and holistic approach to leadership and employee development in vocational contexts.

2.
Nutrients ; 16(13)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38999895

RESUMEN

Excessive alcohol consumption has led to the prevalence of gastrointestinal ailments. Alleviating gastric disorders attributed to alcohol-induced thinning of the mucus layer has centered on enhancing mucin secretion as a pivotal approach. In this study, foxtail millet bran polyphenol BPIS was divided into two components with MW < 200 D and MW > 200 D by molecular interception technology. Combined with MTT, cell morphology observation, and trypan blue staining, isoferulic acid (IFA) within the MW < 200 D fraction was determined as the effective constituent to mitigate ethanol-induced damage of gastric epithelial cells. Furthermore, a Wistar rat model with similar clinical features to alcohol-induced gastric mucosal injury was established. Then, gastric morphological observation, H&E staining, and assessments of changes in gastric hexosamine content and gastric wall binding mucus levels were carried out, and the results revealed that IFA (10 mg/Kg) significantly ameliorated alcohol-induced gastric mucosal damage. Finally, we applied techniques including Co-IP, molecular docking, and fluorescence spectroscopy and found that IFA inhibited the alcohol-induced downregulation of N-acetylgalactosamintransferase 2 (GALNT2) activity related to mucus synthesis through direct interaction with GALNT2 in gastric epithelial cells, thus promoting mucin synthesis. Our study lays a foundation for whole grain dietary intervention tailored to individuals suffering from alcoholic gastric mucosal injury.


Asunto(s)
Etanol , Mucosa Gástrica , Ratas Wistar , Animales , Mucosa Gástrica/efectos de los fármacos , Mucosa Gástrica/patología , Ratas , Masculino , Setaria (Planta) , Extractos Vegetales/farmacología , Humanos , Células Epiteliales/efectos de los fármacos , Simulación del Acoplamiento Molecular , Modelos Animales de Enfermedad
3.
Food Sci Nutr ; 12(6): 4473-4485, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38873460

RESUMEN

Quinoa is a nutrient-dense pseudocereal that has garnered global attention for its potential to bolster food security and nutrition. Despite its celebrated status, the detailed nutritional profiles of various quinoa varieties remain poorly understood, which poses a significant barrier to the strategic cultivation and utilization of quinoa's genetic diversity to combat malnutrition. The impetus for this research lies in the urgent need to identify superior quinoa strains that can be tailored to meet specific nutritional requirements and adapt to diverse agro-ecological zones. Our findings reveal substantial variation in nutrient content across different quinoa varieties, highlighting the variety ZLZX-8 as a particularly nutrient-rich strain with the highest levels of protein, fat, essential fatty acids, amino acids, and key minerals such as Mg, K, and Zn. Moreover, ZLZX-8's exceptional antioxidant capacity suggests it may have additional health benefits beyond its macronutrient profile. In contrast, ZLZX-7 stands out for its dietary fiber and phenolic content, which are critical for digestive health and disease prevention, respectively. Meanwhile, ZLZX-5, with its high starch content, could be better suited for energy production in dietary applications. Notably, the study also uncovers a correlation between grain color and nutrient profile, with colored quinoa varieties exhibiting superior fiber, inositol, phenolic content, and antioxidant activity compared to their white counterparts. This work lays the groundwork for an informed selection of quinoa varieties that can enhance dietary quality, support local and global food systems, and contribute to the fight against malnutrition.

4.
JAMA Ophthalmol ; 142(8): 708-715, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38935400

RESUMEN

Importance: Capsular tension rings (CTRs) can support weak zonules and inhibit capsular shrinkage, thus potentially reducing intraocular lens (IOL) decentration and tilt. However, it has been debated whether CTRs can reduce IOL decentration and tilt in highly myopic eyes and whether CTR implantation is necessary for all highly myopic eyes. Objective: To evaluate the influence of CTR implantation on IOL decentration and tilt in highly myopic eyes. Design, Setting, and Participants: This randomized clinical trial was conducted between November 2021 and September 2023 at the Zhongshan Ophthalmic Center, Guangzhou, China. Patients with cataract and an axial length (AL) of 26 mm or longer were enrolled. Interventions: Participants were stratified into 3 groups based on the AL (stratum 1, 26 mm ≤ AL <28 mm; stratum 2, 28 mm ≤ AL <30mm; stratum 3, AL ≥30 mm), and further randomly assigned to the CTR group (a C-loop IOL combined with a CTR) or the control group (only a C-loop IOL) within each stratum. Main Outcomes and Measures: IOL decentration at 3 months after cataract surgery was evaluated using anterior segment optical coherence tomography. Results: A total of 186 eyes of 186 participants (mean [SD] age, 57.3 [10.9] years; 118 female [63.4%]) were randomized into the CTR group (93 [50%]) or control group (93 [50%]), with 87 eyes (93.6%) and 92 eyes (98.9%) completing follow-up at 3 months, respectively. The CTR group showed smaller IOL decentration (0.19 mm vs 0.23 mm; difference, -0.04 mm; 95% CI, -0.07 to -0.01 mm; P = .02) and tilt at 3 months, and lower proportions of clinically significant IOL decentration (≥0.4 mm) and tilt (≥7°) at 3 months compared with the control group. Similar results were only found in eyes with an AL of 30 mm or longer (IOL decentration: 0.20 mm vs 0.28 mm; difference, -0.08 mm; 95% CI, -0.14 to -0.02 mm; P = .01). Additionally, the CTR group showed a smaller change in IOL decentration from 1 week to 3 months, higher prediction accuracy, and better visual quality and patient satisfaction in this stratum. No differences were observed between the CTR and control groups in eyes with an AL less than 30 mm. Conclusions and Relevance: CTR implantation reduced C-loop IOL decentration and tilt, increased position stability, and improved visual quality in eyes with an AL of 30 mm or longer. These findings support use of CTR implantation in eyes with an AL of 30 mm or longer and implanted with C-loop IOLs. Trial Registration: ClinicalTrials.gov Identifier: NCT05161520.


Asunto(s)
Migracion de Implante de Lente Artificial , Lentes Intraoculares , Facoemulsificación , Agudeza Visual , Humanos , Femenino , Masculino , Persona de Mediana Edad , Agudeza Visual/fisiología , Anciano , Migracion de Implante de Lente Artificial/fisiopatología , Migracion de Implante de Lente Artificial/cirugía , Implantación de Lentes Intraoculares , Miopía Degenerativa/fisiopatología , Miopía Degenerativa/cirugía , Prótesis e Implantes , Estudios Prospectivos , Refracción Ocular/fisiología , Estudios de Seguimiento , Tomografía de Coherencia Óptica , Cápsula del Cristalino/cirugía , Implantación de Prótesis
5.
Transl Vis Sci Technol ; 13(5): 24, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38809530

RESUMEN

Purpose: To evaluate the association between preoperative ocular parameters and myopic shift following primary intraocular lens (IOL) implantation in pediatric cataracts. Methods: Eyes from pediatric patients undergoing bilateral cataract surgery with primary IOL implantation were included. Eyes were grouped by age at surgery and subdivided into three axial length (AL) subgroups and three keratometry subgroups. Mixed-effects linear regression was utilized to assess the trend in myopic shift among subgroups. Multivariable analysis was performed to determine factors associated with myopic shift. Results: A total of 222 eyes were included. The median age at surgery was 4.36 years (interquartile range [IQR], 3.16-6.00 years) and the median follow-up was 4.18 years (IQR, 3.48-4.64 years). As preoperative AL increased, a decreased trend was observed in myopic shift and rate of myopic shift (P = 0.008 and P = 0.003, respectively, in the 4 to <6 years old group; P = 0.002 and P < 0.001, respectively, in the ≥6 years old group). Greater myopic shift and rate of myopic shift were associated with younger age at surgery (P = 0.008 and P = 0.008, respectively). Both myopic shift and rate of myopic shift were negatively associated with AL. Conclusions: Age at surgery and preoperative AL were associated with myopic shift in pediatric cataracts following primary IOL implantation. Adjusting the target refraction based on preoperative AL could potentially improve patients' long-term refractive outcome. Translational Relevance: This study may help to guide the selection of postoperative target refraction according to age at surgery and preoperative ocular parameters for pediatric cataracts.


Asunto(s)
Implantación de Lentes Intraoculares , Miopía , Humanos , Implantación de Lentes Intraoculares/efectos adversos , Femenino , Miopía/cirugía , Miopía/fisiopatología , Masculino , Preescolar , Niño , Estudios Retrospectivos , Refracción Ocular/fisiología , Longitud Axial del Ojo/patología , Catarata/complicaciones , Catarata/fisiopatología , Extracción de Catarata/efectos adversos , Agudeza Visual/fisiología , Periodo Preoperatorio , Estudios de Seguimiento
6.
Int J Ophthalmol ; 17(3): 473-479, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721502

RESUMEN

AIM: To establish a classification for congenital cataracts that can facilitate individualized treatment and help identify individuals with a high likelihood of different visual outcomes. METHODS: Consecutive patients diagnosed with congenital cataracts and undergoing surgery between January 2005 and November 2021 were recruited. Data on visual outcomes and the phenotypic characteristics of ocular biometry and the anterior and posterior segments were extracted from the patients' medical records. A hierarchical cluster analysis was performed. The main outcome measure was the identification of distinct clusters of eyes with congenital cataracts. RESULTS: A total of 164 children (299 eyes) were divided into two clusters based on their ocular features. Cluster 1 (96 eyes) had a shorter axial length (mean±SD, 19.44±1.68 mm), a low prevalence of macular abnormalities (1.04%), and no retinal abnormalities or posterior cataracts. Cluster 2 (203 eyes) had a greater axial length (mean±SD, 20.42±2.10 mm) and a higher prevalence of macular abnormalities (8.37%), retinal abnormalities (98.52%), and posterior cataracts (4.93%). Compared with the eyes in Cluster 2 (57.14%), those in Cluster 1 (71.88%) had a 2.2 times higher chance of good best-corrected visual acuity [<0.7 logMAR; OR (95%CI), 2.20 (1.25-3.81); P=0.006]. CONCLUSION: This retrospective study categorizes congenital cataracts into two distinct clusters, each associated with a different likelihood of visual outcomes. This innovative classification may enable the personalization and prioritization of early interventions for patients who may gain the greatest benefit, thereby making strides toward precision medicine in the field of congenital cataracts.

9.
Nat Commun ; 15(1): 3650, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38688925

RESUMEN

Utilization of digital technologies for cataract screening in primary care is a potential solution for addressing the dilemma between the growing aging population and unequally distributed resources. Here, we propose a digital technology-driven hierarchical screening (DH screening) pattern implemented in China to promote the equity and accessibility of healthcare. It consists of home-based mobile artificial intelligence (AI) screening, community-based AI diagnosis, and referral to hospitals. We utilize decision-analytic Markov models to evaluate the cost-effectiveness and cost-utility of different cataract screening strategies (no screening, telescreening, AI screening and DH screening). A simulated cohort of 100,000 individuals from age 50 is built through a total of 30 1-year Markov cycles. The primary outcomes are incremental cost-effectiveness ratio and incremental cost-utility ratio. The results show that DH screening dominates no screening, telescreening and AI screening in urban and rural China. Annual DH screening emerges as the most economically effective strategy with 341 (338 to 344) and 1326 (1312 to 1340) years of blindness avoided compared with telescreening, and 37 (35 to 39) and 140 (131 to 148) years compared with AI screening in urban and rural settings, respectively. The findings remain robust across all sensitivity analyses conducted. Here, we report that DH screening is cost-effective in urban and rural China, and the annual screening proves to be the most cost-effective option, providing an economic rationale for policymakers promoting public eye health in low- and middle-income countries.


Asunto(s)
Catarata , Análisis Costo-Beneficio , Tamizaje Masivo , Humanos , China/epidemiología , Catarata/economía , Catarata/diagnóstico , Catarata/epidemiología , Persona de Mediana Edad , Tamizaje Masivo/economía , Tamizaje Masivo/métodos , Masculino , Tecnología Digital/economía , Femenino , Cadenas de Markov , Anciano , Inteligencia Artificial , Telemedicina/economía , Telemedicina/métodos
10.
Exp Eye Res ; 243: 109899, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38636802

RESUMEN

Virus-like particles (VLP) are a promising tool for intracellular gene delivery, yet their potential in ocular gene therapy remains underexplored. In this study, we bridged this knowledge gap by demonstrating the successful generation and application of vesicular stomatitis virus glycoprotein (VSVG)-pseudotyped mouse PEG10 (MmPEG10)-VLP for intraocular mRNA delivery. Our findings revealed that PEG10-VLP can efficiently deliver GFP mRNA to adult retinal pigment epithelial cell line-19 (ARPE-19) cells, leading to transient expression. Moreover, we showed that MmPEG10-VLP can transfer SMAD7 to inhibit epithelial-mesenchymal transition (EMT) in RPE cells effectively. In vivo experiments further substantiated the potential of these vectors, as subretinal delivery into adult mice resulted in efficient transduction of retinal pigment epithelial (RPE) cells and GFP reporter gene expression without significant immune response. However, intravitreal injection did not yield efficient ocular expression. We also evaluated the transduction characteristics of MmPEG10-VLP following intracameral delivery, revealing transient GFP protein expression in corneal endothelial cells without significant immunotoxicities. In summary, our study established that VSVG pseudotyped MmPEG10-based VLP can transduce mitotically inactive RPE cells and corneal endothelial cells in vivo without triggering an inflammatory response, underscoring their potential utility in ocular gene therapy.


Asunto(s)
Técnicas de Transferencia de Gen , ARN Mensajero , Epitelio Pigmentado de la Retina , Animales , Ratones , Epitelio Pigmentado de la Retina/metabolismo , ARN Mensajero/genética , Terapia Genética/métodos , Vectores Genéticos , Ratones Endogámicos C57BL , Humanos , Proteínas Fluorescentes Verdes/genética , Transición Epitelial-Mesenquimal , Glicoproteínas de Membrana/genética , Glicoproteínas de Membrana/metabolismo
11.
Exp Eye Res ; 243: 109906, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38657786

RESUMEN

Pediatric cataract, including congenital and developmental cataract, is a kind of pediatric vision-threatening disease with extensive phenotypic heterogeneity and multiple mechanisms. We aimed to investigate the metabolite profile of aqueous humor (AH) in patients with pediatric cataracts, and identify underlying mutual correlations between differential metabolites. Metabolomic profiles of AH were analyzed and compared between pediatric cataract patients (n = 33) and age-related cataract patients without metabolic diseases (n = 29), using global untargeted metabolomics with ultra-high-performance liquid chromatography tandem mass spectrometry. Principal component analysis, partial least squares discriminant analysis and heat map were applied. Enriched pathway analysis was conducted using Kyoto Encyclopedia of Genes and Genomes. Receiver-operating characteristic (ROC) analyses were employed to select potential biomarkers. A total of 318 metabolites were identified, of which 54 differential metabolites (25 upregulated and 29 downregulated) were detected in pediatric cataract group compared with controls (variable importance of projection >1.0, fold change ≥1.5 or ≤ 0.667 and P < 0.05). A significant accumulation of N-Acetyl-Dl-glutamic acid was observed in pediatric cataract group. The differential metabolites were mainly enriched in histidine metabolism (increased L-Histidine and decreased 1-Methylhistamine) and the tryptophan metabolism (increased N-Formylkynurenine and L-Kynurenine). 5-Aminosalicylic acid showed strong positive mutual inter-correlation with L-Tyrosinemethylester and N,N-Diethylethanolamine, both of which were down-regulated in pediatric cataract group. The ROC analysis implied 11 metabolites served as potential biomarkers for pediatric cataract patients (all area under the ROC curve ≥0.900). These results illustrated novel potential metabolites and metabolic pathways in pediatric cataract, which provides new insights into the pathophysiology of pediatric cataract.


Asunto(s)
Humor Acuoso , Biomarcadores , Catarata , Metabolómica , Humanos , Humor Acuoso/metabolismo , Catarata/metabolismo , Metabolómica/métodos , Masculino , Femenino , Preescolar , Cromatografía Líquida de Alta Presión , Niño , Biomarcadores/metabolismo , Curva ROC , Espectrometría de Masas en Tándem , Metaboloma/fisiología , Lactante
12.
Br J Ophthalmol ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38604621

RESUMEN

AIMS: To document longitudinal changes in spherical equivalent refraction (SER) and related biometric factors during early refractive development. METHODS: This was a prospective cohort study of Chinese children, starting in 2018 with annual follow-ups. At each visit, children received cycloplegic autorefraction and ocular biometry measurements. Lens power (LP) was calculated using Bennett's formula. Children were divided into eight groups based on baseline age: the 3-year-old (n=426, 49.77% girls), 4-year-old (n=834, 47.36% girls), 6-year-old (n=292, 46.58% girls), 7-year-old (n=964, 43.46% girls), 9-year-old (n=981, 46.18% girls), 10-year-old (n=1181, 46.32% girls), 12-year-old (n=504, 49.01%) and 13-year-old (n=644, 42.70%) age groups. RESULTS: This study included right-eye data from 5826 children. The 3-year-old and 4-year-old age groups demonstrated an inflection point in longitudinal SER changes at a mild hyperopic baseline SER (+1 to +2 D), with children with more myopic SER showing hyperopic refractive shifts while those with more hyperopic SER showing myopic shifts. The hyperopic shift in SER was mainly attributed to rapid LP loss and was rarely seen in the older age groups. Axial elongation accelerated in the premyopia stage, accompanied by a partially counter-balancing acceleration of LP loss. For children aged 3-7 years, those with annual SER changes <0.25 D were all mildly hyperopic at baseline (mean: 1.23 D, 95% CI 1.20 to 1.27 D). CONCLUSION: Our findings suggest that during early refractive development, refractions cluster around or above +1.00 D. There is a pushback process in which increases in the rate of LP occur in parallel with increases in axial elongation.

13.
Artículo en Inglés | MEDLINE | ID: mdl-38647002

RESUMEN

With the rapid development of multimedia technology, the student centered flipped classroom model (FCM) and massive open online courses (MOOCs) have been increasingly introduced and implemented in higher medical education. However, comparative analyses of the offline face-to-face FCM and completely online FCM have been rarely reported. In this study, we focused specifically on a set of flipped classrooms in which prerecorded videos were provided before class. Using the Zhihuishu platform as the major online course platform, our team built a MOOC and evaluated the teaching effectiveness of the FCM in both the offline face-to-face class and the online electronic live class for medical genetics education. Questionnaires, paper-based and oral exams were used to collect data on the teaching effects of the different teaching methods. We found that student satisfaction and overall student performance in the offline FCM group was significantly higher than that in the completely online teaching group. Although online FCM allowed students to play back and review anywhere and anytime after class, students taught in offline FCM had a significantly higher degree of knowledge mastery, had a deeper understanding of theoretical knowledge, and were better at knowledge comprehensive application. The effects of their training on genetic disease clinical diagnosis and treatment skills were significantly better, and their capacity for scientific research was also significantly improved. Our research discussed the advantages of the online courses and the problems brought about by using these technologies, and it provided insight into online teaching practices in the era of internet-based medical education.

14.
Foods ; 13(5)2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38472825

RESUMEN

Plant-derived exosome-like nanovesicles (PELNs) are bilayer membrane-enclosed nanovesicles secreted by plant cells, serving as carriers of various substances such as proteins, RNA, and metabolites. The mounting evidence suggests that PELN plays a crucial role in transmembrane signaling, nutrient transportation, apoptosis, and regulation of gut microbiota composition. This makes it a promising "dark nutrient" for plants to modulate human physiology and pathogenesis. A comprehensive understanding of PELN formation, uptake, and functional mechanisms can offer novel insights into plant nutrition and functional properties, thereby facilitating the precise development of plant-based foods and drugs. This article provides a summary of PELN extraction and characterization, as well as absorption and delivery processes. Furthermore, it focuses on the latest discoveries and underlying physiological mechanisms of PELN's functions while exploring future research directions.

15.
J Hazard Mater ; 469: 134056, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38522208

RESUMEN

The extensive use of antidiabetic drugs (ADDs) and their detection in high concentrations in the environment have been extensively documented. However, the mechanism of ADDs dissipation in aquatic environments is still not well understood. This study thoroughly investigates the dissipation behavior of ADDs and the underlying mechanisms in the aerobic activated sludge system. The results indicate that the removal efficiencies of ADDs range from 3.98% to 100% within 48 h, largely due to the biodegradation process. Additionally, the gene expression of cytochrome P450 (CYP450) is shown to be significantly upregulated in most ADDs-polluted samples (P < 0.05), indicating the vital role of CYP450 enzymes in the biodegradation of ADDs. Enzyme inhibition experiments validated this hypothesis. Moreover, molecular docking and simulation results indicate that a strong correlation between the biodegradation of ADDs and the interactions between ADDs and CYP450 (Ebinding). The differences in dissipation behavior among the tested ADDs are possibly due to their electrophilic characteristics. Overall, this study makes the initial contribution to a more profound comprehension of the crucial function of CYP450 enzymes in the dissipation behavior of ADDs in a typical aquatic environment.


Asunto(s)
Sistema Enzimático del Citocromo P-450 , Aguas del Alcantarillado , Aguas del Alcantarillado/química , Simulación del Acoplamiento Molecular , Sistema Enzimático del Citocromo P-450/genética , Sistema Enzimático del Citocromo P-450/metabolismo , Biodegradación Ambiental
16.
Am J Ophthalmol ; 262: 237-245, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38452920

RESUMEN

PURPOSE: To investigate the relationship between effective lens position (ELP) and patient characteristics, and to further develop a new intraocular lens (IOL) calculation formula for cataract patients with previous pars plana vitrectomy (PPV). DESIGN: Cross-sectional study. METHODS: A total of 2793 age-related cataract patients (group 1) and 915 post-PPV cataract patients (group 2) who underwent phacoemulsification with IOL implantation were included. The ELP of 2 groups was compared and the association between ELP and patient characteristics was further evaluated using standardized multivariate regression coefficients. An ensemble artificial intelligence-based ELP prediction model was developed using a training set of 810 vitrectomized eyes, and a thick-lens IOL formula (LISA-PPV) was constructed and compared with 7 existing formulas on an external multi-center testing set of 105 eyes. RESULTS: Compared to eyes with age-related cataract, vitrectomized eyes showed a similar ELP distribution (P = .19), but different standardized coefficients of preoperative biometry for ELP. The standardized coefficients also varied with the type of vitreous tamponade, history of scleral buckling, and ciliary sulcus IOL implantation. The LISA-PPV formula showed the lowest mean and median absolute prediction error (MAE: 0.63 D; MedAE: 0.44 D), and the highest percentages of eyes within ±0.5 D of prediction error (57.14%) in the testing dataset. CONCLUSIONS: The ELP prediction required optimization specifically for vitrectomized eyes based on their biometric and surgical characteristics. The LISA-PPV formula is a useful and accurate tool for determining IOL power in cataract patients with previous PPV (available at http://ppv-iolcalculator.com/).


Asunto(s)
Inteligencia Artificial , Biometría , Implantación de Lentes Intraoculares , Lentes Intraoculares , Óptica y Fotónica , Facoemulsificación , Vitrectomía , Humanos , Estudios Transversales , Masculino , Femenino , Anciano , Vitrectomía/métodos , Biometría/métodos , Persona de Mediana Edad , Agudeza Visual/fisiología , Anciano de 80 o más Años , Refracción Ocular/fisiología , Catarata/fisiopatología , Catarata/complicaciones , Estudios Retrospectivos
17.
Asia Pac J Ophthalmol (Phila) ; 13(1): 100001, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38383078

RESUMEN

PURPOSE: To investigate the between-eye differences of the crystalline lens in subjects with unilateral high myopia and assess its contribution to the interocular refractive error disparity. METHODS: Children and adolescents with unilateral high myopia, defined as cycloplegic spherical equivalent (SE) ≤ -5D in one eye and ≥ -3D in the other eye, were recruited. Ocular biometric parameters, including axial length (AL) and lens thickness (LT), were measured by IOLMaster 700. Other lens-related parameters, including anterior lens radius of curvature (ALR) and posterior lens radius of curvature (PLR), were measured by CASIA2 swept-source optical coherence tomography. Lens power (LP) was calculated using Bennett's formula. Paired t-test was used to assess the between-eye difference in biometric parameters, and multiple regression analysis was used to assess factors associated with the between-eye SE difference. RESULTS: Ninety-one participants (6-18 years of age; 52.75% girls) were included. The highly myopic eyes showed significantly lower LP (P < 0.001) and smaller ALR (P < 0.001) than the contralateral eyes, while no significant difference was found in central LT. In both eyes, ALR was significantly related to SE (P = 0.001 and P = 0.006, respectively); while LT was not associated with SE (P = 0.051 and P = 0.052, respectively). Paired-eye analysis showed that the between-eye difference in ALR was the only lenticular parameter significantly associated with the between-eye difference in SE (P = 0.005). CONCLUSION: In highly myopic eyes, the crystalline lens reduced total power but morphologically changed to a more curved shape without significant lens thinning, suggesting that the LP loss is mainly achieved by reducing its internal power in high myopes.


Asunto(s)
Cristalino , Miopía , Errores de Refracción , Niño , Femenino , Humanos , Adolescente , Masculino , Ojo , Miopía/complicaciones , Refracción Ocular , Errores de Refracción/complicaciones , Longitud Axial del Ojo
18.
Nucleic Acids Res ; 52(5): 2212-2230, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38364871

RESUMEN

Nonreference sequences (NRSs) are DNA sequences present in global populations but absent in the current human reference genome. However, the extent and functional significance of NRSs in the human genomes and populations remains unclear. Here, we de novo assembled 539 genomes from five genetically divergent human populations using long-read sequencing technology, resulting in the identification of 5.1 million NRSs. These were merged into 45284 unique NRSs, with 29.7% being novel discoveries. Among these NRSs, 38.7% were common across the five populations, and 35.6% were population specific. The use of a graph-based pangenome approach allowed for the detection of 565 transcript expression quantitative trait loci on NRSs, with 426 of these being novel findings. Moreover, 26 NRS candidates displayed evidence of adaptive selection within human populations. Genes situated in close proximity to or intersecting with these candidates may be associated with metabolism and type 2 diabetes. Genome-wide association studies revealed 14 NRSs to be significantly associated with eight phenotypes. Additionally, 154 NRSs were found to be in strong linkage disequilibrium with 258 phenotype-associated SNPs in the GWAS catalogue. Our work expands the understanding of human NRSs and provides novel insights into their functions, facilitating evolutionary and biomedical researches.


Asunto(s)
Genoma Humano , Estudio de Asociación del Genoma Completo , Grupos de Población , Humanos , Diabetes Mellitus Tipo 2/genética , Desequilibrio de Ligamiento , Fenotipo , Polimorfismo de Nucleótido Simple , Genética de Población , Grupos de Población/genética
19.
Acta Ophthalmol ; 102(5): e718-e726, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38235601

RESUMEN

PURPOSE: To determine whether correcting the axial length (AL) measurement error of the IOLMaster 700 could improve the refractive prediction accuracy in silicone oil-filled eyes. METHODS: This study included 265 cataract patients (265 eyes) with silicone oil tamponade who were scheduled for phacoemulsification with intraocular lens (IOL) implantation. The performances of various formulas, including Barrett Universal II, Emmetropia Verifying Optical, Hoffer-QST, Kane, Ladas Super Formula, Pearl-DGS, Radial Basis Function and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T), were evaluated. The refractive prediction errors (PE) calculated with measured AL (ALmeas) and corrected AL with silicone oil adjustment (SOAL) were compared. Subgroup analysis was performed based on the ALmeas (<23 mm; 23-26 mm; ≥26 mm). RESULTS: Using SOAL significantly reduced the hyperopic PE of formulas when compared to ALmeas (-0.05 to 0.17 D vs 0.15 to 0.38 D, p < 0.001). After applying AL correction, all formulas showed a lower mean absolute PE (0.47-0.57 D vs 0.50-0.69 D). The percentage of eyes within ±1.0 D of PE increased from 84.91%-88.68% to 89.81%-91.32% for new formulas and from 78.11%-83.40% to 85.66%-88.68% for traditional formulas, with the use of SOAL. Subgroup analysis showed that the majority of formulas with SOAL in prediction accuracy for eyes with an AL ≥26 mm (p < 0.05). CONCLUSIONS: The refractive prediction accuracy in silicone oil-filled eyes was improved by correcting the AL measurement error of the IOLMaster 700, especially for long eyes.


Asunto(s)
Longitud Axial del Ojo , Facoemulsificación , Refracción Ocular , Aceites de Silicona , Humanos , Aceites de Silicona/administración & dosificación , Femenino , Masculino , Longitud Axial del Ojo/diagnóstico por imagen , Refracción Ocular/fisiología , Anciano , Facoemulsificación/métodos , Persona de Mediana Edad , Agudeza Visual/fisiología , Biometría/métodos , Estudios Retrospectivos , Endotaponamiento/métodos , Reproducibilidad de los Resultados , Errores de Refracción/fisiopatología , Errores de Refracción/diagnóstico , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Anciano de 80 o más Años
20.
Acta Ophthalmol ; 102(5): e805-e812, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38292001

RESUMEN

PURPOSE: The purpose of this study was to compare the tilt and decentration of one-piece anti-vaulting haptic intraocular lenses (IOL) and three-piece C-loop haptic IOLs in paediatric eyes undergoing secondary IOL implantation into the ciliary sulcus. METHODS: Paediatric aphakic patients receiving either one-piece anti-vaulting haptic or three-piece C-loop haptic IOL implants into the ciliary sulcus were enrolled in this prospective non-randomized interventional study and followed up for 3 years. IOL decentration and tilt were measured using Scheimpflug images. Preoperative and postoperative information, including demographic data and ocular biometric parameters and complications, were collected and analysed. RESULTS: Among 123 eyes of 79 paediatric patients, there were 72 eyes (58.54%) in the anti-vaulting haptic IOL group and 51 eyes (41.46%) in the C-loop haptic group. The anti-vaulting haptic IOL group had a lower incidence of clinically significant vertical IOL decentration than the C-loop haptic IOL group (23.88% vs. 43.14%, p = 0.037). No intergroup differences were observed in vertical or horizontal tilt or in horizontal decentration (all p > 0.05). One-piece anti-vaulting haptic IOL implantation was associated with a lower risk of clinically significant vertical decentration than three-piece C-loop haptic IOL implantation (odds ratio: 0.42, p = 0.037). There was a higher incidence of IOL dislocation in the C-loop haptic IOL group (15.22% vs. 4.17%, p = 0.046). CONCLUSIONS: In paediatric aphakic eyes undergoing secondary IOL implantation into the ciliary sulcus, one-piece anti-vaulting haptic IOLs can reduce the risk of clinically significant vertical IOL decentration compared with three-piece C-loop haptic IOLs and may favour long-term IOL positional stability.


Asunto(s)
Cuerpo Ciliar , Implantación de Lentes Intraoculares , Lentes Intraoculares , Diseño de Prótesis , Agudeza Visual , Humanos , Estudios Prospectivos , Masculino , Femenino , Lentes Intraoculares/efectos adversos , Preescolar , Estudios de Seguimiento , Cuerpo Ciliar/cirugía , Implantación de Lentes Intraoculares/métodos , Niño , Afaquia Poscatarata/fisiopatología , Afaquia Poscatarata/cirugía , Migracion de Implante de Lente Artificial/diagnóstico , Migracion de Implante de Lente Artificial/etiología , Migracion de Implante de Lente Artificial/prevención & control , Migracion de Implante de Lente Artificial/fisiopatología , Lactante , Refracción Ocular/fisiología , Complicaciones Posoperatorias/epidemiología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...