Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Thorac Imaging ; 39(4): 208-216, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38635472

RESUMEN

PURPOSE: Small left atrial (LA) volume was recently reported to be one of the best predictors of acute pulmonary embolism (PE)-related adverse events (AE). There is currently no data available regarding the impact that body surface area (BSA)-indexing of atrial measurements has on the association with PE-related adverse events. Our aim is to assess the impact of indexing atrial measurements to BSA on the association between computed tomography (CT) atrial measurements and AE. MATERIALS AND METHODS: Retrospective study (IRB: 2015P000425). A database of hospitalized patients with acute PE diagnosed on CT pulmonary angiography (CTPA) between May 2007 and December 2014 was reviewed. Right and left atrial volume, largest axial area, and axial diameters were measured. Patients undergo both echocardiographies (from which the BSA was extracted) and CTPAs within 48 hours of the procedure. The patient's body weight was measured during each admission. LA measurements were correlated to AE (defined as the need for advanced therapy or PE-related mortality at 30 days) before and after indexing for BSA. The area under the ROC curve was calculated to determine the predictive value of the atrial measurements in predicting AE. RESULTS: The study included 490 acute PE patients; 62 (12.7%) had AE. There was a significant association of reduced BSA-indexed and non-indexed LA volume (both <0.001), area (<0.001 and 0.001, respectively), and short-axis diameters (both <0.001), and their respective RA/LA ratios (all <0.001) with AE. The AUC values were similar for BSA-indexed and non-indexed LA volume, diameters, and area with LA volume measurements being the best predictor of adverse outcomes (BSA-indexed AUC=0.68 and non-indexed AUC=0.66), followed by non-indexed LA short-axis diameter (indexed AUC=0.65, non-indexed AUC=0.64), and LA area (indexed AUC=0.64, non-indexed AUC=0.63). CONCLUSION: Adjusting for BSA does not substantially affect the predictive ability of atrial measurements on 30-day PE-related adverse events, and therefore, this adjustment is not necessary in clinical practice. While LA volume is the better predictor of AE, LA short-axis diameter has a similar predictive value and is more practical to perform clinically.


Asunto(s)
Superficie Corporal , Angiografía por Tomografía Computarizada , Atrios Cardíacos , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagen , Femenino , Estudios Retrospectivos , Masculino , Atrios Cardíacos/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Angiografía por Tomografía Computarizada/métodos , Tamaño de los Órganos , Ecocardiografía/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años
2.
J Thorac Imaging ; 38(5): 261-269, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37115947

RESUMEN

In this report and analysis of the results of a late 2021 post-COVID pandemic survey of members of the Society of Thoracic Radiology, we compared cardiothoracic radiologist workloads and burnout rates with those obtained from a prepandemic survey of society members. The more recent survey also asked respondents to provide a subjective assessment of their individual workload capacity should they be required to read cases at a section average daily case work volume, and this assessment was correlated with burnout rates. To measure nonrelative value unit workload, we requested data on non-case-related work responsibilities including teaching and multidisciplinary conferences that were not assessed in the first survey. In addition, we asked respondents to provide information on the availability of support services, personnel, and hardware and software tools that could improve work efficiency and reduce radiologist stress levels thereby mitigating burnout. We found that postpandemic case workload and cardiothoracic radiologists' burnout rates were similarly high compared with prepandemic levels with an overall burnout rate of 88% including a 100% burnout rate among women which had significantly increased. The range of radiologists' workload capacity is broad, although 80% of respondents reported that reading at an average sectional case volume was at or above their capacity, and the perceived capacity correlated with burnout measures. The presence of fellows and computer-aided diagnosis/artificial intelligence tools were each associated with significant decreases in burnout, providing 2 potential strategies that could be employed to address high cardiothoracic radiologist burnout rates.


Asunto(s)
Agotamiento Profesional , COVID-19 , Radiología , Humanos , Femenino , Carga de Trabajo , Inteligencia Artificial , Radiólogos , Encuestas y Cuestionarios , Radiología/educación
3.
Eur J Radiol ; 143: 109886, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34412010

RESUMEN

PURPOSE: Assess and compare the quality and diagnostic performance of CCTA between pre-liver and pre-kidney transplant patients, and gauge impact of CCTA on ICA requirements. METHODS: Patients without known coronary artery disease (CAD) were selected for CCTA if considered high-risk or after abnormal stress testing. All pre-liver and pre-kidney CCTAs between March 2018 and August 2020 were retrospectively included. CCTA quality was qualitatively graded as excellent/good/fair/poor, and CAD graded as < or ≥50% stenosis. Heart rate, coronary artery calcium (CAC) scores, and fractional flow reserve CT (FFRCT) results were collected. CAD stenosis was graded on invasive coronary angiogram (ICA) images, with ≥50% stenosis defined as significant. RESULTS: 162 pre-transplant patients (91 pre-liver, 71 pre-kidney). Pre-kidney patients had poorer CCTA quality (p = 0.04) and higher heart rate (median: 65 bpm vs 60 bpm, p < 0.001). Out of 147 diagnostic CCTAs (pre-liver: 84, pre-kidney: 63), 73 (49.7%) had a ≥50% stenosis (pre-liver: 38 (45.2%), pre-kidney:35 (55.6%)). 12/38 (31.6%) had a significantly reduced FFRCT, and 19/53 (35.8%) had ≥50% stenosis on ICA. Among patients whose CCTA was diagnostic and had ICA, stenosis severity was concordant in 10/23 (43.5%) pre-liver and 10/25 (40%) pre-kidney patients. All discordant cases had stenosis 'over-called' on CCTA. CONCLUSION: Diagnostic-quality CCTAs in high-risk pre-transplant patients are achievable and can greatly reduce ICA requirements by excluding significant CAD. CCTA quality is poorer in pre-kidney transplant patients compared to pre-liver, possibly due to higher heart rate.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Trasplante de Riñón , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Hígado , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
4.
Medicina (Kaunas) ; 52(5): 276-282, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27746117

RESUMEN

BACKGROUND AND AIM: Cutaneous squamous cell carcinoma (CSCC) is a malignant epithelial cell tumor. CSCC has a tendency to spread via lymphogenic pathway. Metastases are found in 2%-6% of cases. Prognosis of patients with CSCC is directly related to the morphology and localization of primary tumor. The aim of this study was to evaluate the recurrence-free survival of patients with CSCC after tumor excision and SLNB as well as to analyze morphologic CSCC features related to patient recurrence-free survival. MATERIALS AND MATERIALS: A retrospective analysis of 51 patients with CSCC, who underwent surgical treatment between January 1, 2012, and December 31, 2014, in the Clinic of Plastic and Reconstructive Surgery, Hospital of the Lithuanian University of Health Sciences, was done. The diagnosis of CSCC was verified on a histological examination, and all patients had no clinical evidence of nodal or distant metastases on a physical examination or imaging studies. Sentinel lymph node biopsy (SLNB) was performed for low- and high-risk CSCC patients. RESULTS: A total of 51 patients were enrolled into the study (34 women and 17 men). Total of 68 lymph nodes were removed during sentinel lymph node biopsy. No micrometastases were identified. Until April 1, 2015, no relapse event was documented. The mean time after operation was 27.5 months. During the follow-up period, no distant metastases were identified. CONCLUSIONS: No patient who had no micrometastases in sentinel lymph nodes developed local and distant CSCC metastases during the follow-up period. Our report supports the concept that SLNB can be applied for CSCC. It is obvious that larger prospective studies with longer follow-up period are needed to establish the efficacy of SLNB and define the optimal treatment of occult nodal metastasis for CSCC.


Asunto(s)
Carcinoma de Células Escamosas/mortalidad , Carcinoma de Células Escamosas/patología , Ganglio Linfático Centinela/patología , Neoplasias Cutáneas/mortalidad , Neoplasias Cutáneas/patología , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/cirugía , Supervivencia sin Enfermedad , Femenino , Humanos , Metástasis Linfática , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Biopsia del Ganglio Linfático Centinela , Neoplasias Cutáneas/cirugía , Tomografía Computarizada de Emisión , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...