Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Esp Cardiol (Engl Ed) ; 77(2): 150-157, 2024 Feb.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37879431

RESUMEN

INTRODUCTION AND OBJECTIVES: The optimal antithrombotic strategy following left atrial appendage closure (LAAC) is poorly defined in patients with nonvalvular atrial fibrillation. We assessed the safety and effectiveness of a single antiplatelet treatment (SAPT) strategy after LAAC in a population at high risk of ischemic and bleeding events. METHODS: This single-center, observational, prospective study included a consecutive cohort of patients who underwent LAAC using the LAmbre device (Lifetech Scientific, China) and who were discharged with SAPT. The primary outcome was a composite of stroke, systemic embolism, and device-related thrombosis during follow-up. Secondary endpoints were cardiovascular mortality and major bleeding events (BARC ≥3a). Clinical follow-up was performed at 1, 6, and 12 months and subsequently on an annual basis. Transesophageal echocardiography was performed at 1 and 12 months of follow-up. RESULTS: The study comprised 74 patients. The median age was 77 [72-83] years and 43% were women. The cohort exhibited a high prevalence of comorbidities and cardiovascular risk factors. The median CHA2DS2-VASc and HAS-BLED scores were 4 [3-6] and 4 [4-5], respectively. The median length of follow-up was 2.5 years (188 patients-year). During follow-up, device-related thrombosis occurred in 3 patients (4%). Ischemic stroke occurred in 1 patient (1.3%, rate 0.5%/y), representing a 90.9% relative risk reduction compared with the risk predicted by CHA2DS2-VASc. Major bleeding events occurred in 12 patients (16%, 6.4%/y), with a relative risk reduction of 26.4% of that predicted by HAS-BLED. Cardiovascular-related mortality was observed in 2 patients (2.7%). CONCLUSIONS: SAPT appears to be a safe and effective treatment following LAAC in patients at high ischemic and hemorrhagic risk. Further studies are needed to confirm our findings.


Asunto(s)
Fibrilación Atrial , Cierre del Apéndice Auricular Izquierdo , Inhibidores de Agregación Plaquetaria , Anciano , Femenino , Humanos , Masculino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Accidente Cerebrovascular/epidemiología , Trombosis/epidemiología , Resultado del Tratamiento , Anciano de 80 o más Años
2.
J Clin Med ; 10(7)2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33915971

RESUMEN

The LAmbreTM device is a novel system designed for left atrial appendage closure (LAAC). First registries showed a high rate of device implantation success. However, few mid-term results are available. We present our 1- and 12-month follow-up results for this device. This prospective, single-center registry included consecutive patients with nonvalvular atrial fibrillation who underwent LAAC with the LAmbreTM device. Transesophageal echocardiography (TEE) was performed at 1-month follow-up. In total, 55 patients were included. The population was elderly (75 ± 9.4 years), with a high proportion of comorbidities. The mean CHA2DS2-VASc and HAS-BLED scores were 4.6 ± 1.6 and 3.9 ± 1.0, respectively. Previous history of a major bleeding event was present in 37 patients (67.3%). Procedural success was achieved in 54 patients (98.2%). Device success was achieved in 100% of patients in whom device implantation was attempted (54 patients). Major in-hospital device-related complications included mortality of one patient (1.8%) and pericardial tamponade in two patients (3.6%); the incidence of stroke was 0%. No thrombus or significant leaks (≥5 mm) were observed on 1-month TEE. At 12 months, adverse events were overall death (1.8%), transient ischemic attack/ischemic stroke (1.8%), and major bleeding events (Bleeding Academic Research Consortium (BARC) 3a and 3c; 11%). In this high-risk population, the LAmbreTM device seems to be a safe and effective option for LAAC with a remarkable mid-term performance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...