Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Diagnostics (Basel) ; 13(14)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37510075

RESUMEN

Laser ablation for treatment of hypothalamic hamartoma (HH) is a minimally invasive and effective technique used to destroy hamartomatous tissue and disconnect it from the functioning brain. Currently, the gold standard to evaluate the amount of tissue being "burned" is the use of heat maps during the ablation procedure. However, these maps have low spatial resolution and can be misleading in terms of extension of the tissue damage. The aim of this study is to use different MRI sequences immediately after each laser ablation and correlate the extension of signal changes with the volume of malacic changes in a long-term follow-up scan. During the laser ablation procedure, we imaged the hypothalamic region with high-resolution axial diffusion-weighted images (DWI) and T2-weighted images (T2WI) after each ablation. At the end of the procedure, we also added a post-contrast T1-weighted image (T1WI) of the same region. We then correlated the product of the maximum diameters on axial showing signal changes (acute oedema on T2WI, DWI restriction rim, DWI hypointense core and post-contrast T1WI rim) with the product of the maximum diameters on axial T2WI of the malacic changes in the follow-up scan, both as a fraction of the total area of the hamartoma. The area of the hypointense core on DWI acquired immediately after the laser ablation statistically correlated better with the final area of encephalomalacia, while the T2WI, hyperintense oedema, DWI rim and T1WI rim of enhancement tended to overestimate the encephalomalacic damage. In conclusion, the use of intraoperative sequences (in particular DWI) during laser ablation can give surgeons valuable information in real time about the effective heating damage on the hamartomatous tissue, with better spatial resolution in comparison to the thermal maps.

2.
Diagnostics (Basel) ; 12(11)2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36428947

RESUMEN

Background: Diaphragmatic alterations occurring during mechanical ventilation (MV) can be monitored using ultrasound (US). The performance of computed tomography (CT) to evaluate diaphragmatic thickness is limited. Further, the association between muscle mass and outcome is increasingly recognized. However, no data are available on its correlation with diaphragmatic thickness. We aimed to determine correlation and agreement of diaphragmatic thickness between CT and US; and its association with muscle mass and MV parameters. Methods: Prospective observational study. US measurements of the diaphragmatic thickness were collected in patients undergoing MV within 12 h before or after performing a CT scan of the thorax and/or upper abdomen. Data on skeletal muscle index (SMI), baseline, and ventilatory data were recorded and correlated with US and CT measures of diaphragmatic thickness. Agreement was explored between US and CT data. Results: Twenty-nine patients were enrolled and the diaphragm measured by CT resulted overall thicker than US-based measurement of the right hemidiaphragm. The US thickness showed the strongest correlation with the left posterior pillar at CT (r = 0.49, p = 0.008). The duration of the controlled MV was negatively correlated with US thickness (r = -0.45, p = 0.017), the thickness of the right anterior pillar (r = -0.41, p = 0.029), and splenic dome by CT (r = -0.43, p = 0.023). SMI was positively correlated with US diaphragmatic thickness (r = 0.50, p = 0.007) and inversely correlated with the duration of MV before enrollment (r = -0.426, p = 0.027). Conclusions: CT scan of the left posterior pillar can estimate diaphragmatic thickness and is moderately correlated with US measurements. Both techniques show that diaphragm thickness decreases with MV duration. The diaphragmatic thickness by US showed a good correlation with SMI.

3.
J Clin Med ; 10(20)2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34682849

RESUMEN

Micro-computed tomography (CT) is a non-invasive alternative to conventional macroscopic dissection for the evaluation of human fetal cardiac anatomy. This paper aims to systematically review the literature regarding the use of micro-CT to examine human fetal hearts, to illustrate its educational and research implications and to explain its possible directions for the future. A systematic literature review was conducted following the PRISMA statement to identify publications concerning micro-CT applications for the isolated human fetal heart. The search strategy identified nine eligible studies. Micro-CT is technically feasible for postmortem examination of the human fetal heart coming from early and late termination of pregnancy. It reaches high diagnostic accuracy, and it seems to perform better than autopsy in small samples or in the case of early termination of pregnancy. Applications derived from micro-CT allow multiple off-time evaluations and interdisciplinary comparisons for educational purposes and research perspectives in biological and bioengineering domains.

4.
Neuroradiol J ; 34(5): 462-469, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33872086

RESUMEN

BACKGROUND AND PURPOSE: To evaluate the added value of a model-based reconstruction algorithm in the assessment of acute traumatic brain lesions in emergency non-enhanced computed tomography, in comparison with a standard hybrid iterative reconstruction approach. MATERIALS AND METHODS: We retrospectively evaluated a total of 350 patients who underwent a 256-row non-enhanced computed tomography scan at the emergency department for brain trauma. Images were reconstructed both with hybrid and model-based iterative algorithm. Two radiologists, blinded to clinical data, recorded the presence, nature, number, and location of acute findings. Subjective image quality was performed using a 4-point scale. Objective image quality was determined by computing the signal-to-noise ratio and contrast-to-noise ratio. The agreement between the two readers was evaluated using k-statistics. RESULTS: A subjective image quality analysis using model-based iterative reconstruction gave a higher detection rate of acute trauma-related lesions in comparison to hybrid iterative reconstruction (extradural haematomas 116 vs. 68, subdural haemorrhages 162 vs. 98, subarachnoid haemorrhages 118 vs. 78, parenchymal haemorrhages 94 vs. 64, contusive lesions 36 vs. 28, diffuse axonal injuries 75 vs. 31; all P<0.001). Inter-observer agreement was moderate to excellent in evaluating all injuries (extradural haematomas k=0.79, subdural haemorrhages k=0.82, subarachnoid haemorrhages k=0.91, parenchymal haemorrhages k=0.98, contusive lesions k=0.88, diffuse axonal injuries k=0.70). Quantitatively, the mean standard deviation of the thalamus on model-based iterative reconstruction images was lower in comparison to hybrid iterative one (2.12 ± 0.92 vsa 3.52 ± 1.10; P=0.030) while the contrast-to-noise ratio and signal-to-noise ratio were significantly higher (contrast-to-noise ratio 3.06 ± 0.55 vs. 1.55 ± 0.68, signal-to-noise ratio 14.51 ± 1.78 vs. 8.62 ± 1.88; P<0.0001). Median subjective image quality values for model-based iterative reconstruction were significantly higher (P=0.003). CONCLUSION: Model-based iterative reconstruction, offering a higher image quality at a thinner slice, allowed the identification of a higher number of acute traumatic lesions than hybrid iterative reconstruction, with a significant reduction of noise.


Asunto(s)
Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador , Encéfalo/diagnóstico por imagen , Humanos , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
5.
Contrast Media Mol Imaging ; 2019: 1767620, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30863218

RESUMEN

Aim: To assess the feasibility of dynamic contrast-enhanced perfusion-MRI in characterization of active small-bowel inflammation and chronic mural fibrosis in patients with Crohn's disease (CD). Methods: We analyzed a total of 37 (11 women; 23-69 years) patients with known biopsy proven CD, who underwent MR-enterography (MRE) study, performed on a 1.5 T MRI system (Achieva, Philips), using a phased array sense body multicoil, after oral administration of 1.5-2 L of PEG solution. MRE protocol included T1 weighted, SSh T2, sBTFE, and gadolinium-enhanced THRIVE sequences acquired on coronal and axial planes. A dedicated workstation was used to generate perfusion color maps, on which we drown ROI on normal bowel and on pathological segment, thus obtaining related perfusion parameters: relative arterial, venous, and late enhancement (RAE, RVE, and RLE), maximum enhancement (ME), and time to peak (TTP). Results: Quantitative perfusion analysis showed a good correlation with local degree of Crohn's inflammation activity. Twenty-nine out of 37 patients showed active inflammatory disease (reference standard of active disease: wall bowel thickness and layered enhancement) with following perfusion parameters: REA (%) = 116.1, RVE (%) = 125.3, RLE (%) = 127.1, ME (%) = 1054.7, TTP (sec) = 157. The same parameters calculated in patients with mural fibrosis were as follows: RAE (%): median = 56.4; RVE (%): 81.2; RLE (%): 85.4; ME (%):809.6; TTP (sec): 203.4. A significant difference (p < 0.001) between inflamed and fibrotic bowel wall vascularity, regarding all perfusion parameters evaluated, was found, with higher values in active CD localizations. Conclusion: Vascular assessment of perfusion kinetics of bowel wall by dynamic contrast perfusion-MR analysis may represent a complementary diagnostic tool that enables a quantitative evaluation of local inflammation activity in CD patients.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Inflamación/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Fibrosis/diagnóstico por imagen , Humanos , Intestino Delgado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Prohibitinas , Estudios Prospectivos , Estudios Retrospectivos , Adulto Joven
6.
Neuroradiology ; 61(7): 737-746, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30693410

RESUMEN

PURPOSE: The aim of our study was to evaluate the postmortem micro-CT anatomy of early fetal human fetal brains, either in situ or isolated. METHODS: We studied 12 ex vivo specimens, 9 whole human fetuses (9-18 GW), and 3 isolated samples (16-26 GW). Specimens were fixed in formalin, then immersed in Lugol solution. Images were evaluated by two neuroradiologists. The depiction of CNS structures was defined based on the comparison between micro-CT images and a reference histologic anatomical Atlas of human brain development. RESULTS: Micro-CT provided informative high-resolution brain images in all cases, with the exception of one case (9 weeks) due to advanced maceration. All major CNS structures (i.e., brain hemispheres, layering, ventricles, germinal neuroepithelium, basal ganglia, corpus callosum, major cranial nerves, and structures of the head and neck) were recognizable. CONCLUSIONS: Micro-CT imaging of the early fetal brain is feasible and provides high-quality images that correlate with the histological Atlas of the human brain, offering multiplanar and volumetric images that can be stored and shared for clinical, teaching, and research purposes.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/embriología , Feto/diagnóstico por imagen , Microtomografía por Rayos X , Autopsia , Cadáver , Edad Gestacional , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador
7.
Neuroradiology ; 60(12): 1273-1280, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30196373

RESUMEN

PURPOSE: Hyperdense artery sign is the earliest sign of ischemic stroke on non-enhanced computed tomography and it can be visible long before parenchymal changes. The aim of our study was to compare diagnostic value of model-based iterative reconstruction algorithm (IMR) with that of iterative reconstruction algorithm (iDose4) in identifying hyperdense artery sign. METHODS: We selected 56 consecutive patients suspected for ischemic stroke, who underwent a NCCT and that demonstrated a vessel occlusion at angio-CT or developed ischemic lesion at follow-up CT. Two readers randomly analyzed images of NCCT reconstructed both with iDose4 (4 mm) and IMR (2 mm), reporting presence of hyperdense artery sign (0: no; 1: yes; 2: not sure). They rated image quality on a 4-point scale (1: unacceptable; 4: more than average) and recorded HU values of clot and of normal vessel and measured noise index, CNR and SNR. RESULTS: Mean values of CTDI, DLP, and ED were respectively of 43 mGy, 819.7 mGy cm, and 1.72 mSv. By analyzing the IMR reconstruction, both readers were able to recognize hyperdense vessel sign in 55/56 patients, while only in 12/56 patients were identified with iDose. IMR obtained better rating of image quality (mean score for IMR 3.32 vs 2.53 for iDose), higher clot density (57.2 vs 46.7 HU), lower noise index (5 vs 2), higher CNR and SNR (respectively 4.2 vs 2 and 16.8 vs 8.5). CONCLUSIONS: Model-based approach significantly increases sensitivity in detecting hyperdense artery sign, offering higher SNR and CNR in brain CT images in comparison with standard hybrid reconstruction algorithm.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Isquemia Encefálica/patología , Angiografía Cerebral , Angiografía por Tomografía Computarizada , Diagnóstico Diferencial , Humanos , Dosis de Radiación , Estudios Retrospectivos , Sensibilidad y Especificidad , Relación Señal-Ruido , Accidente Cerebrovascular/patología
8.
Eur J Radiol ; 106: 62-68, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30150052

RESUMEN

PURPOSE: To investigate whether perfusion-CT (p-CT) imaging could depict the inhibition of tumor neoangiogenesis induced by Sorafenib in advanced hepatocellular carcinoma (HCC), and whether it could be useful in predicting survival during treatment. MATERIALS AND METHODS: Ninety-eight p-CT examinations were performed among 29 cirrhotic patients, with advanced HCC, before and every 2 months after Sorafenib administration, on a 256-slice MDCT scanner. Perfusion parameters were considered and statistically compared, at baseline and follow-up, between non-progressor (complete response, stable disease or partial response) and progressor (progressive disease) group. Kaplan-Meier analyses estimated the time-to-survival in overall population, after stratifying patients according to mRECIST. RESULTS: The group that responded to Sorafenib showed a significant reduction of values in HCC target lesions after anti-angiogenic therapy (p < 0.01), in comparison with progressor group that demonstrated an increase or no significant variation. When patients were stratified into mRECIST, higher survival rate was observed in the non-progressor group compared to the progressor (48.6% vs 28.6%), and statistically significant correlation (p=0.01) was found between percentage variation of perfusion parameters, from baseline to follow-up, and overall survival rate. CONCLUSION: Quantitative analysis of perfusion parameters, represents prognostic indicators useful in assessment of response to anti-angiogenic therapy, allowing for optimization of individualized treatment.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Hígado/efectos de los fármacos , Sorafenib/farmacología , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Antineoplásicos/farmacología , Biomarcadores , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/patología , Femenino , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Pronóstico , Intensificación de Imagen Radiográfica , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos
9.
J Comput Assist Tomogr ; 40(5): 692-700, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27560010

RESUMEN

PURPOSE: The aim of this study was to investigate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in evaluation of blood flow changes related to transarterial chemoembolization (TACE) and radiofrequency ablation (RFA) procedures in patients with hepatocellular carcinoma (HCC) lesions. METHODS: Fifty-four patients, with biopsy-proven HCC, who underwent TACE or RFA, were evaluated, 1 month after treatment, with upper abdominal MRI examination. Multiplanar T2-weighted, T1-weighted, and dynamic contrast-enhanced sequences were acquired. Dedicated perfusion software (T1 Perfusion Package, Viewforum; Philips Medical Systems, The Netherlands) was used to generate color permeability maps. After placing regions of interest in normal hepatic parenchyma, in successfully treated lesions, and in area of recurrence, the following perfusion parameters were calculated and statistically analyzed: relative arterial, venous, and late enhancement; maximum enhancement; maximum relative enhancement, and time to peak. RESULTS: Twenty-one of 54 patients had residual disease, and perfusion parameters values measured within tumor tissue were: relative arterial enhancement median, 42%; relative venous enhancement median, 69%; relative late enhancement median, 57.7%; maximum enhancement median, 749.6%; maximum relative enhancement median, 69%; time to peak median, 81.1 seconds. As for all the evaluated parameters, a significant difference (P < 0.05) was found between residual viable tumor tissue and effective treated lesions. CONCLUSIONS: Dynamic contrast-enhanced MRI represents a complementary noninvasive tool that may offer quantitative and qualitative information about HCC lesions treated with TACE and RFA.


Asunto(s)
Carcinoma Hepatocelular/fisiopatología , Carcinoma Hepatocelular/terapia , Circulación Hepática , Neoplasias Hepáticas/fisiopatología , Neoplasias Hepáticas/terapia , Angiografía por Resonancia Magnética/métodos , Anciano , Velocidad del Flujo Sanguíneo , Carcinoma Hepatocelular/diagnóstico por imagen , Ablación por Catéter/métodos , Quimioembolización Terapéutica/métodos , Medios de Contraste , Femenino , Gadolinio DTPA , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
10.
Eur J Radiol ; 85(1): 268-273, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26526900

RESUMEN

PURPOSE: To compare radiation dose, image quality and diagnostic performance of low dose CT enterography (CTE) protocol combined with iterative reconstruction algorithm (iDose(4)) with standard dose CTE in follow-up of patients with known Crohn's disease (CD). MATERIALS AND METHOD: Thirty-six patients (12 females), with CD underwent a low-dose CTE scan during single venous phase on 256 MDCT scanner, with the following parameters: 120 kV, automated mAs dose-modulation, slice thickness 2mm and iDose(4) iterative reconstruction algorithm. A control group of thirty-seven patients underwent standard dose CTE examination on the same CT scanner. Two radiologists, blinded to clinical and pathological findings, independently evaluated in each scan, HU values in bowel wall and any presence of CD activity features and disease complications. Image noise and diagnostic quality were evaluated using a 4-point scale. Dose-length product (DLP) and CT-dose-index (CTDI) were recorded and data from both examinations were compared and statistically analyzed. RESULTS: Low-dose CTE protocol showed high diagnostic quality in assessment of Crohn's disease obtaining significantly (p ≤ 0.001) lower values of DLP and CTDI (604.98 mGy*cm and 12.29 mGy) as compared to standard dose examinations (974.85 mGy*cm and 19.71 mGy), with an overall dose reduction of 37.6%. Noise resulted slightly higher in iDose(4) images (SD=15.97) than in standard dose ones (SD=13.61) but this difference was not statistically significant (p=0.064). CONCLUSION: Low-dose CTE combined with iDose(4) reconstruction algorithm offers high quality images with significant reduction of radiation dose, and therefore can be considered a useful tool in the management of CD patients, considering their young age and the frequent imaging follow-up required.


Asunto(s)
Algoritmos , Enfermedad de Crohn/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Femenino , Estudios de Seguimiento , Humanos , Intestinos/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...