Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Appl Radiat Isot ; 204: 111148, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38128301

RESUMEN

In this work, both undoped and Thulium (Tm3+) doped (0.3-10 mol%) magnesium pyrophosphate (Mg2P2O7) powders were synthesized by the solvent evaporation method to study their photo-and thermoluminescent properties. Two crystalline phases were observed in the powders by X-Ray diffraction (XRD), the main phase being Mg2P2O7 and the second one thulium phosphate (TmPO4). The superficial morphology was analyzed by scanning electron microscopy (SEM), which revealed that the powders are agglomerates with an undefined form and grains with non-uniform size distribution. The photoluminescence (PL) emission spectra of Tm3+ doped powders show the 1D2 → 3F4 transition, associated with Tm3+ ions, at 452 and 458 nm. The thermoluminescence (TL) properties were analyzed in the undoped and Tm3+ doped powders exposed to 90Sr beta source. The TL glow curve of Tm3+ doped powders exhibits three maxima at about ⁓64-66 °C, ⁓198-202 °C, and ⁓301 °C. The TL dose-response is sub-linear from 0.11 to 0.54 Gy, linear between 0.79 and 24.95 Gy, and supra-linear from 34.99 to 599.95 Gy. Acceptable repeatability with a coefficient of variation of ∼1% was obtained after ten cycles of irradiation and readout. At 63 d of storage, the powders show fading of 30%, and at 1.6 years (585 d), the integrated TL intensity decays by 47%. The kinetic parameters of activation energy and frequency factor were evaluated using the Initial Rise, Booth, Bohun, and Porfianovitch (BBP) and Hoogenstraaten methods and Glow Curve Deconvolution with a general order kinetic model.

3.
Microb Ecol ; 86(2): 810-824, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36574041

RESUMEN

It is widely accepted that in many aquatic ecosystems bacterioplankton is dependent on and regulated by organic carbon supplied by phytoplankton, leading to coupled algae-bacteria relationship. In this study, an in-depth analysis of this relationship has been carried out by combining two approaches: (i) a correlation analyses between heterotrophic bacterial production (BP) vs. primary production (PP) or algal excretion of organic carbon (EOC), (ii) the balance between bacterial carbon demands (BCD) and the supply of C as EOC, measured as BCD:EOC ratio. During the study period (2013-2016), the algae-bacteria relationship was constantly changing from a coupling in 2013, uncoupling in 2014 and 2015, and an incipient return to coupling (in 2016). Our results show that top-down control (bacterivory) by algal mixotrophy acts as a decoupling force since it provides a fresh C source different to algal EOC to satisfy bacterial carbon demands. Notably, a relationship between the BCD:EOC ratio and the ecosystem metabolic balance (Primary production (PP): respiration (R)) was found, suggesting that PP:R may be a good predictor of the algae-bacteria coupling. This analysis, including the comparison between basal and potential ecosystem metabolic balance, can be a tool to improve knowledge on the interaction between both biotics compartments, which the traditional analyses on coupling may not capture.


Asunto(s)
Ecosistema , Fitoplancton , Fitoplancton/metabolismo , Bacterias/metabolismo , Carbono/metabolismo
4.
Appl Radiat Isot ; 191: 110532, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36332425

RESUMEN

This work reports on the thermoluminescence (TL) properties and detection of contaminating minerals isolated from Mexican cocoa beans irradiated with gamma radiation and stored for 4 years. Contaminating minerals isolated from cocoa beans consisting of quartz, diopside, plagioclase, albite, and iron oxide with irregular and rectangular grains and average length of 135 µm. Cocoa beans are detected as irradiated even after 4 years of storage using the shape and maximum temperature of the TL glow curve of contaminating minerals. The TL properties of dose-response, and fading of minerals were also analysed. The TL dose-response is linear from 5 to 100 Gy, supra-linear between 250 and 1000 Gy, and sub-linear above 1500 Gy. Based on the TL1/TL2 ratio the minerals are identified as irradiated from 250 Gy to 4500 Gy in the dose-response test and after different storage times in the darkness at room temperature. A continuum trap distribution can be associated with the TL glow curve of minerals using the Tm-Tstop method. First order kinetic peaks were used in the Glow Curve Deconvolution of natural and irradiated (1 and 10 kGy) TL curves.


Asunto(s)
Cuarzo , Rayos gamma , Temperatura
5.
Appl Radiat Isot ; 179: 110021, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34775272

RESUMEN

In this investigation, the Continuous-Wave Optically Stimulated Luminescence (CW-OSL) properties of polyminerals extracted from Mexican and Peruvian Guajillo chilli were studied using a source of cesium-137 (Cs-137) gamma radiation. The Guajillo chilli polyminerals were stimulated with blue light for 120 s, and their luminescence was detected in the UV region. The General Order Kinetics (GOK) deconvolution analysis of the CW-OSL curves was carried out using three individual components. The CW-OSL dose response from 10 to 5000 Gy was analysed in Guajillo chilli polyminerals. After different storage periods, the polyminerals show an increase in the CW-OSL intensity. A strong and moderate effect of the sunlight (60 min) and artificial (6 h) light is observed on the CW-OSL response. Therefore, the CW-OSL properties of polyminerals could be used in the identification of Mexican and Peruvian Guajillo chilli exposed to Cs-137 gamma radiation.


Asunto(s)
Rayos gamma , Iluminación , Minerales/química , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Radioisótopos de Cesio/química , Luz Solar
6.
Rev. chil. neuro-psiquiatr ; 59(3): 255-261, sept. 2021. tab, ilus
Artículo en Español | LILACS | ID: biblio-1388395

RESUMEN

Resumen La presencia de alteraciones de señal en resonancia magnética (RM) cerebral durante o posterior a un evento epiléptico es cada vez más reconocida en la literatura. Los cambios de señal peri-ictales se considera que sería el resultado de edema cerebral localizado, defecto de la autorregulación cerebral y disrupción de la barrera hemato-encefálica que ocurre durante una crisis epiléptica sostenida. Reportamos el caso de un hombre de 62 años diagnosticado de un síndrome parietal de instalación subaguda cuyo estudio con RM de cerebro mostró una lesión tumefacta con edema cortico-subcortical de ubicación temporo-occipital derecha. El estudio con electroencefalograma mostró actividad ictal en la misma localización. Se inició terapia con fármacos anticonvulsivantes mostrando franca mejoría clínica y electrofisiológica. El control con RM diferido mostró resolución completa de las alteraciones descritas.


The presence seizure-induced signal changes on brain magnetic resonance imaging (MRI) have been increasingly recognized in the literature. The reversible MRI changes in epileptic patients may be the result of a local brain swelling, a defect of cerebral autoregulation and a blood-brain barrier disruption during sustained epileptogenic activity. We report a 62 years old man diagnosed with a subacute right parietal syndrome. MRI shows a tumefactive lesion in right temporo-occipital lobes mimicking a structural lesion. Electroencephalogram (EEG) exhibits continuous ictal activity in the same region. Antiepileptic drugs were started achieving progressive electro-clinical improvement. Subsequent MRI showed remission of signal changes.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Convulsiones/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Convulsiones/fisiopatología , Diagnóstico Diferencial , Electroencefalografía , Epilepsia
7.
Phys Med Biol ; 66(15)2021 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-34233309

RESUMEN

Purpose.Electronic portal image devices (EPIDs) have been investigated previously for beams-eye view (BEV) applications such as tumor tracking but are limited by low contrast-to-noise ratio and detective quantum efficiency. A novel multilayer imager (MLI), consisting of four stacked flat-panels was used to measure improvements in fiducial tracking during liver stereotactic body radiation therapy (SBRT) procedures compared to a single layer EPID.Methods.The prototype MLI was installed on a clinical TrueBeam linac in place of the conventional DMI single-layer EPID. The panel was extended during volumetric modulated arc therapy SBRT treatments in order to passively acquire data during therapy. Images were acquired for six patients receiving SBRT to liver metastases over two fractions each, one with the MLI using all 4 layers and one with the MLI using the top layer only, representing a standard EPID. The acquired frames were processed by a previously published tracking algorithm modified to identify implanted radiopaque fiducials. Truth data was determined using respiratory traces combined with partial manual tracking. Results for 4- and 1-layer mode were compared against truth data for tracking accuracy and efficiency. Tracking and noise improvements as a function of gantry angle were determined.Results. Tracking efficiency with 4-layers improved to 82.8% versus 58.4% for the 1-layer mode, a relative improvement of 41.7%. Fiducial tracking with 1-layer returned a root mean square error (RMSE) of 2.1 mm compared to 4-layer RMSE of 1.5 mm, a statistically significant (p < 0.001) improvement of 0.6 mm. The reduction in noise correlated with an increase in successfully tracked frames (r = 0.913) and with increased tracking accuracy (0.927).Conclusion. Increases in MV photon detection efficiency by utilization of a MLI results in improved fiducial tracking for liver SBRT treatments. Future clinical applications utilizing BEV imaging may be enhanced by including similar noise reduction strategies.


Asunto(s)
Aceleradores de Partículas , Radiocirugia , Algoritmos , Diagnóstico por Imagen , Marcadores Fiduciales , Humanos , Fantasmas de Imagen
8.
Phys Med Biol ; 65(22): 225004, 2020 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-33284786

RESUMEN

Electronic portal imaging devices (EPIDs) lend themselves to beams-eye view clinical applications, such as tumor tracking, but are limited by low contrast and detective quantum efficiency (DQE). We characterize a novel EPID prototype consisting of multiple layers and investigate its suitability for use under clinical conditions. A prototype multi-layer imager (MLI) was constructed utilizing four conventional EPID layers, each consisting of a copper plate, a Gd2O2S:Tb phosphor scintillator, and an amorphous silicon flat panel array detector. We measured the detector's response to a 6 MV photon beam with regards to modulation transfer function, noise power spectrum, DQE, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and the linearity of the detector's response to dose. Additionally, we compared MLI performance to the single top layer of the MLI and the standard Varian AS-1200 detector. Pre-clinical imaging was done on an anthropomorphic phantom, and the detector's CNR, SNR and spatial resolution were assessed in a clinical environment. Images obtained from spine and liver patient treatment deliveries were analyzed to verify CNR and SNR improvements. The MLI has a DQE(0) of 9.7%, about 5.7 times the reference AS-1200 detector. Improved noise performance largely drives the increase. CNR and SNR of clinical images improved three-fold compared to reference. A novel MLI was characterized and prepared for clinical translation. The MLI substantially improved DQE and CNR performance while maintaining the same resolution. Pre-clinical tests on an anthropomorphic phantom demonstrated improved performance as predicted theoretically. Preliminary patient data were analyzed, confirming improved CNR and SNR. Clinical applications are anticipated to include more accurate soft tissue tracking.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Equipos y Suministros Eléctricos , Humanos , Fantasmas de Imagen , Relación Señal-Ruido , Investigación Biomédica Traslacional
9.
Sci Adv ; 6(19): eaaz2433, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32494709

RESUMEN

Coxsackievirus B (CVB) enteroviruses are common human pathogens known to cause severe diseases including myocarditis, chronic dilated cardiomyopathy, and aseptic meningitis. CVBs are also hypothesized to be a causal factor in type 1 diabetes. Vaccines against CVBs are not currently available, and here we describe the generation and preclinical testing of a novel hexavalent vaccine targeting the six known CVB serotypes. We show that the vaccine has an excellent safety profile in murine models and nonhuman primates and that it induces strong neutralizing antibody responses to the six serotypes in both species without an adjuvant. We also demonstrate that the vaccine provides immunity against acute CVB infections in mice, including CVB infections known to cause virus-induced myocarditis. In addition, it blocks CVB-induced diabetes in a genetically permissive mouse model. Our preclinical proof-of-concept studies demonstrate the successful generation of a promising hexavalent CVB vaccine with high immunogenicity capable of preventing CVB-induced diseases.


Asunto(s)
Infecciones por Coxsackievirus , Miocarditis , Animales , Infecciones por Coxsackievirus/prevención & control , Enterovirus Humano B , Ratones , Primates , Vacunas Combinadas
10.
Arch Soc Esp Oftalmol (Engl Ed) ; 95(8): 379-385, 2020 Aug.
Artículo en Inglés, Español | MEDLINE | ID: mdl-32532593

RESUMEN

PURPOSE: Spectral-domain optical coherence tomography (SD-OCT) is the most useful tool to measure choroidal thickness (CT). CT may be increased in ocular and systemic diseases. However, there are concerns relating reproducibility and external validity of OCT. The aim of this study was to assess the inter-observer and intra-observer variability of manual OCT measurements. METHODS: CT was manually measured in the central choroid of 40 eyes from 21 subjects (11 healthy and 10 with ankylosing spondylitis) using RTVue-100 OCT (Optovue Inc., Fremont, CA, EE.UU.). Measurements were performed by 9 independent ophthalmologists from 6 different centers. To assess the inter-observer variability, the intra-class correlation coefficient (ICC) method was calculated. Also, intra-observer variability was assessed in 2 of the ophthalmologists. RESULTS: The mean subfoveal CT was 364.9±85.1µm (range, 170 to 572). The inter-observer ICC was 0.823 (CI 95%, 0.749 to 0.888, p<0.001). The intra-observer ICCs were 0.885 (CI 95%, 0.783 to 0.939, p<0.001) and 0.925 (CI 95%, 0.859 to 0.960. p<0.001). CONCLUSIONS: In this study, manual measurements of CT with OCT showed a good concordance. These results suggest that manual OCT is a valid tool for multicenter studies.


Asunto(s)
Coroides/anatomía & histología , Coroides/diagnóstico por imagen , Tomografía de Coherencia Óptica , Adolescente , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reproducibilidad de los Resultados , Adulto Joven
11.
Phys Med Biol ; 65(12): 125011, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32330918

RESUMEN

Tumor tracking during radiotherapy treatment can improve dose accuracy, conformity and sparing of healthy tissue. Many methods have been introduced to tackle this challenge utilizing multiple imaging modalities, including a template matching based approach using the megavoltage (MV) on-board portal imager demonstrated on 3D conformal treatments. However, the complexity of treatments is evolving with the introduction of VMAT and IMRT, and successful motion management is becoming more important due to a trend towards hypofractionation. We have developed a markerless lung tumor tracking algorithm, utilizing the electronic portal imager (EPID) of the treatment machine. The algorithm has been specifically adapted to track during complex treatment deliveries with gantry and MLC motion. The core of the algorithm is an adaptive template matching method that relies on template stability metrics and local relative orientations to perform multiple feature tracking simultaneously. Only a single image is required to initialize the algorithm and features are automatically added, modified or removed in response to the input images. This algorithm was evaluated against images collected during VMAT arcs of a dynamic thorax phantom. Dynamic phantom images were collected during radiation delivery for multiple lung SBRT breathing traces and an example patient data set. The tracking error was 1.34 mm for the phantom data and 0.68 mm for the patient data. A multi-region, markerless tracking algorithm has been developed, capable of tracking multiple features simultaneously without requiring any other a priori information. This novel approach delivers robust target localization during complex treatment delivery. The reported tracking error is similar to previous reports for 3D conformal treatments.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Automatización , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento , Fantasmas de Imagen
12.
Rev Clin Esp (Barc) ; 220(3): 149-154, 2020 Apr.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31690452

RESUMEN

BACKGROUND: The increased survival of patients with HIV infection thanks to antiretroviral therapy (ART) is accompanied by a higher rate of cardiovascular disease (CVD). We analysed the prevalence of the cardiovascular risk factors (CRFs) and estimated the risk of CVD in a cohort of patients with HIV in Spain. METHODS: We conducted a cross-sectional, observational study of CRFs in the Spanish VACH cohort of patients with HIV who undergo ART. RESULTS: The study assessed 15,559 patients with HIV (76% men; mean age, 46 years). Some 3.7% had experienced at least 1 CVD event. The prevalence of CRFs was high (hyperlipidaemia, 64%; tobacco use, 47%; arterial hypertension, 22%; and diabetes, 16%). According to the Framingham scale, 10.9% of the patients presented a high CVD risk, and 28.8% presented a moderate risk. Of the patients with a high CVD risk, 49% took protease inhibitors and 43% took abacavir. Fifty-three percent of the patients diagnosed with arterial hypertension took antihypertensive drugs, and 2.6% of the patients with diabetes took antidiabetic agents. CONCLUSIONS: Classical CRFs are common in patients with HIV undergoing ART in Spain, and a large proportion of them have a moderate-high risk of CVD. Therefore, controlling the modifiable CRFs in patients with HIV should be improved, and the use of drugs with a better cardiovascular risk profile should be assessed.

13.
Appl Radiat Isot ; 124: 44-48, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28324825

RESUMEN

In this work, luminescent emissions of beta-calcium pyrophosphate doped with terbium ions (ß-Ca2P2O7:Tb3+) were studied. The Ca2P2O7:Tb3+ powders were prepared by precipitation and annealed at 900°C for 2h was applied on the powders to observe the beta phase. Radioluminescence measurements showed emission bands related with 5D3 (5D4)→7FJ transitions of Tb3+ ions. Three overlapped peaks at 126, 165 and 220°C were observed in thermoluminescence response. A linear TL dose-response in the range of 0.2-10Gy and an acceptable TL reproducibility were showed by the ß-Ca2P2O7:Tb3+ samples exposed to 60Co gamma radiation. The TL glow curves were analyzed by Initial Rise method and Computational Glow-Curve Deconvolution assuming a General Order Kinetic model to evaluate the kinetic parameters related with the TL peaks.

14.
J Antimicrob Chemother ; 72(1): 246-253, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27629070

RESUMEN

OBJECTIVES: We evaluated whether maintenance therapy with atazanavir/ritonavir plus lamivudine (ATV/r + 3TC) was non-inferior to ATV/r plus two nucleosides (ATV/r + 2NUCs) at 96 weeks of follow-up. METHODS: SALT is a multicentre, open-label, non-inferiority clinical trial in HIV-1-infected virologically suppressed patients. Hepatitis B virus surface antigen-negative subjects with no previous treatment failure/resistance mutations and HIV-1-RNA <50 copies/mL for ≥6 months were randomized (1 : 1) to ATV/r + 3TC or ATV/r + 2NUCs. The primary endpoint was HIV-1-RNA <50 copies/mL in the PP population. Non-inferiority was demonstrated if the lower bound of the 95% CI for the difference was not below -12%. RESULTS: Some 286 patients were analysed. At week 96, 74.4% had HIV-1-RNA <50 copies/mL in the ATV/r + 3TC arm versus 73.9% in the ATV/r + 2NUCs arm (95% CI for the difference, -9.9%-11.0%). In both groups, similar values were observed for patients with confirmed virological failure in ATV/r + 3TC versus ATV/r + 2NUCs (9 versus 5), death (1 versus 0), discontinuation due to ART-related toxicity (7 versus 11), withdrawal from the study (7 versus 9) and loss to follow-up (6 versus 6). One patient taking ATV/r + 2NUCs developed resistance mutations (M184V and L63P). Similar values were obtained for change in mean CD4 count [19 versus 18 cells/mm3 (95% CI for the difference, -49.3-50.7), grade 3-4 adverse events (70.7% versus 70.2%) and changes in the global deficit score, -0.3 (95% CI, -0.5 to -0.1) for ATV/r + 3TC, versus -0.2 (95% CI, -0.4 to -0.1) for ATV/r + 2NUCs]. CONCLUSIONS: The long-term results of switching to ATV/r + 3TC show that this strategy is effective, safe and non-inferior to ATV + 2NUCs in virologically suppressed HIV-infected patients.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Terapia Antirretroviral Altamente Activa/métodos , Quimioterapia de Mantención/métodos , Adulto , Anciano , Anciano de 80 o más Años , Fármacos Anti-VIH/efectos adversos , Terapia Antirretroviral Altamente Activa/efectos adversos , Femenino , Humanos , Quimioterapia de Mantención/efectos adversos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Carga Viral , Adulto Joven
15.
HIV Med ; 18(3): 196-203, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27476742

RESUMEN

OBJECTIVES: The aim of the study was to investigate whether very low level viraemia (VLLV) (20-50 HIV-1 RNA copies/mL) was associated with increased risk of virological failure (VF) as compared with persistent full suppression (< 20 copies/mL). METHODS: From the VACH Cohort database, we selected those patients who started antiretroviral therapy (ART) after January 1997 and who achieved effective viral suppression [two consecutive viral loads (VLs) < 50 copies/mL] followed by full suppression (at least one VL <20 copies/mL). We carried out survival analyses to investigate whether the occurrence of VLLV rather than maintaining full suppression at < 20 copies/mL was associated with virological failure (two consecutive VLs > 200 copies/mL or one VL > 200 copies/mL followed by a change of ART regimen, administrative censoring or loss to follow-up), adjusted for nadir CD4 cell count, sex, age, ethnicity, transmission group, type of ART and time on effective suppression at < 50 copies/mL. RESULTS: Of 21 480 patients who started ART, 13 674 (63.7%) achieved effective suppression at < 50 copies/mL, of whom 4289 (31.4%) further achieved full suppression at < 20 copies/mL after May 2009. A total of 2623 patients (61.1%) remained fully suppressed thereafter, while 1666 had one or more episodes of VL detection > 20 copies/mL (excluding virological failure). A total of 824 patients had VLLV after suppression at < 20 copies/mL. VLLV was not associated with virological failure as compared with persistent full suppression [hazard ratio (HR) 0.67; 95% confidence interval (CI) 0.44-1.00], independently of the number of blips recorded (from one to 18). CONCLUSIONS: In our population of HIV-infected patients on ART who achieved viral suppression at < 20 copies/mL, the risk of virological failure was no different for patients who remained fully suppressed compared with those who experienced subsequent episodes of VLLV.


Asunto(s)
Antirretrovirales/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , VIH-1/aislamiento & purificación , Respuesta Virológica Sostenida , Carga Viral , Viremia , Adolescente , Adulto , Estudios de Cohortes , Femenino , Infecciones por VIH/virología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Riesgo , Medición de Riesgo , Insuficiencia del Tratamiento , Adulto Joven
16.
Int J Cosmet Sci ; 39(1): 101-107, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27506896

RESUMEN

OBJECTIVES: To study (i) the diversity of the natural colour of the human hair through both visual assessment of hair tone levels and colorimetric measurements of hair strands collected from 2057 human male and female volunteers, from 23 regions of the world and (ii) the correlation between visual assessments and colorimetric measurements. METHODS: Hair strands were analysed by a spectrocolorimeter under the L*, a*, b* referential system and scored in vivo by experts before sampling, through standardized visual reference scales based on a 1-10 range. RESULTS: Results show that from a typological aspect, black or dark brown hairs largely predominate among studied ethnic groups, whereas Caucasian or derived populations exhibit the widest palette of medium to fair shades, partly explaining some past interbreeding among populations. Instrumental measurements clearly confirm that a given colour of a pigmented hair, at the exclusion of red hairs, is mostly governed by two components, L* and b*, from the L*, a*, b* reference system. CONCLUSION: The comparisons between visual assessments and instrumental data show that these appear closely linked. Darker hairs show close or subtle variations in L*, a*, b* parameters, making their individual colour differentiation calling for technical improvements in colorimetric measurements. The latter are likely governed by other physical factors such as shape, diameter and shine.


Asunto(s)
Color del Cabello , Colorimetría , Femenino , Humanos , Masculino , Encuestas y Cuestionarios
18.
Artículo en Inglés | MEDLINE | ID: mdl-24594886

RESUMEN

This paper reports on both cathodoluminescence (CL) and blue thermoluminescence (TL) emission of well-characterized natural Spanish and Brazilian apatites [Ca5(PO4)3(OH, F, Cl)]. Chemical analyses performed by means of Electron Microprobe Analysis (EMPA) have shown the presence of trace elements that can induce CL bands. In this sense, the apatites shown emission bands peaked at 3.26, 2.86, 2.62, 2.14, 2.02 and 1.94eV are respectively linked to substitutional Ce(3+), Tb(3+), Dy(3+), Pr(3+), Sm(3+) and Mn(2+) in structural Ca(2+) positions. The 3.18eV emission band can be associated with intrinsic electron defects on oxygen of the phosphate group (PO4)(3-). The presence of (UO2)(2+) gives rise to an emission at 2.14eV. All the studied aliquots exhibit one single UV-blue TL peak that modifies the position from one sample to another (370, 256 and 268°C) probably due to (i) the variation in the crystallinity index (from 0.88 to 1.34) and (ii) successive chemical processes such as oxidation, dehydration, dehydroxylation, and fluorine ions losses due to the thermal readout.


Asunto(s)
Apatitas/química , Calcio/análisis , Elementos de la Serie de los Lantanoides/análisis , Luminiscencia , Mediciones Luminiscentes , Manganeso/análisis , Espectrometría Raman , Uranio/análisis , Difracción de Rayos X
19.
Artículo en Inglés | MEDLINE | ID: mdl-24210921

RESUMEN

The luminescence (cathodoluminescence and thermoluminescence) properties of natural bones (Siberian mammoth and adult elephant), commercial hydroxyapatite and collagen were analyzed. Chemical analyses of the natural bones were determined using by Electron Probe Micro-Analysis (EMPA). Structural, molecular and thermal characteristics were determined by X-ray Diffraction (XRD), Raman spectroscopy and Differential Thermal and Thermogravimetric analysis (DTA-TG). Cathodoluminescence (CL) spectra of natural bones and collagen showed similar intense broad bands at 440 and 490 nm related to luminescence of the tetrahedral anion [Formula: see text] or structural defects. A weaker luminescence exhibited at 310 nm could be attributed to small amount of rare earth elements (REEs). Four luminescent bands at 378, 424, 468 and 576 nm were observed in the commercial hydroxyapatite (HAP). Both natural bones and collagen samples exhibited natural thermoluminescence (NTL) with well-defined glow curves whereas that the induced thermoluminescence (ITL) only appears in the samples of commercial hydroxyapatite and collagen. Additional explanations for the TL anomalous fading of apatite, as a crucial difficulty performing dosimetry and dating, are also considered.


Asunto(s)
Huesos/química , Colágeno/química , Durapatita/química , Animales , Bovinos , Elefantes , Luminiscencia , Mediciones Luminiscentes , Mamuts , Espectrometría Raman , Difracción de Rayos X
20.
Reprod Domest Anim ; 49(1): 27-31, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23879476

RESUMEN

In the spermatozoa of some species, the ubiquitin-proteasome system detects altered proteins and tags them for elimination by the proteasome. In some species' ejaculates, a high proportion of ubiquitinated spermatozoa (i.e. those having ubiquitin bound to the altered or damaged membrane proteins) has been related to infertility. The aim of this study was to assess whether the percentage of ubiquitinated spermatozoa relates to fertility of dairy bulls and whether ubiquitination increases during protein remodelling that occurs during in vitro spermatic capacitation. Thirty-two frozen semen straws from four high-fertility (ReproMax(®) ) and four normal-fertility (Normal) Holstein-Friesian sires were evaluated. Ubiquitinated and capacitated spermatozoa were quantified by sperm ubiquitin tag immunoassay and chlortetracycline stain, respectively. Fertilizing capacity of sires was assessed by in vitro fertilization. No differences were found between Normal and ReproMax(®) sires with regard to the observed percentage of ubiquitinated spermatozoa (42.97 ± 3.69% and 49.68 ± 9.27%, respectively; p > 0.05). Additionally, no differences were found in the percentage of ubiquitinated spermatozoa as a consequence of spermatic capacitation in either Normal (42.97 ± 3.69% before capacitation vs 44.67 ± 7.5% after; p > 0.05) or ReproMax(®) sires (49.68 ± 9.27% before vs 45.05 ± 7.51% after; p > 0.05). The percentage of ubiquitinated spermatozoa in a thawed sperm samples did not correlate with its in vitro fertilizing capacity; thus, this assay does not prove useful to detect in vivo fertility differences between sires. Additionally, protein degradation occurring during remodelling of the spermatozoon plasma membrane during the capacitation process does not seem to involve the ubiquitin-proteasome system.


Asunto(s)
Bovinos , Fertilización/fisiología , Preservación de Semen/veterinaria , Espermatozoides/química , Espermatozoides/fisiología , Animales , Criopreservación/veterinaria , Fertilización In Vitro/veterinaria , Calor , Masculino , Preservación de Semen/métodos , Capacitación Espermática , Recuento de Espermatozoides/veterinaria , Ubiquitinación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...