Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Neurosci ; 27(5): 913-926, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38528202

RESUMEN

Piezo1 regulates multiple aspects of the vascular system by converting mechanical signals generated by fluid flow into biological processes. Here, we find that Piezo1 is necessary for the proper development and function of meningeal lymphatic vessels and that activating Piezo1 through transgenic overexpression or treatment with the chemical agonist Yoda1 is sufficient to increase cerebrospinal fluid (CSF) outflow by improving lymphatic absorption and transport. The abnormal accumulation of CSF, which often leads to hydrocephalus and ventriculomegaly, currently lacks effective treatments. We discovered that meningeal lymphatics in mouse models of Down syndrome were incompletely developed and abnormally formed. Selective overexpression of Piezo1 in lymphatics or systemic administration of Yoda1 in mice with hydrocephalus or Down syndrome resulted in a notable decrease in pathological CSF accumulation, ventricular enlargement and other associated disease symptoms. Together, our study highlights the importance of Piezo1-mediated lymphatic mechanotransduction in maintaining brain fluid drainage and identifies Piezo1 as a promising therapeutic target for treating excessive CSF accumulation and ventricular enlargement.


Asunto(s)
Líquido Cefalorraquídeo , Canales Iónicos , Vasos Linfáticos , Animales , Ratones , Líquido Cefalorraquídeo/metabolismo , Hidrocefalia/genética , Canales Iónicos/metabolismo , Canales Iónicos/genética , Vasos Linfáticos/metabolismo , Mecanotransducción Celular/fisiología , Meninges/metabolismo , Ratones Endogámicos C57BL , Ratones Transgénicos , Pirazinas , Tiadiazoles , Humanos
2.
Cell Mol Bioeng ; 16(4): 325-339, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37811004

RESUMEN

Introduction: Lymphatic vessels (LVs) maintain fluid homeostasis by draining excess interstitial fluid, which is accomplished by two distinct LVs: initial LVs and collecting LVs. The interstitial fluid is first drained into the initial LVs through permeable "button-like" lymphatic endothelial cell (LEC) junctions. Next, the drained fluid ("lymph") transports to lymph nodes through the collecting LVs with less permeable "zipper-like" junctions that minimize loss of lymph. Despite the significance of LEC junctions in lymphatic drainage and transport, it remains unclear how luminal or interstitial flow affects LEC junctions in vascular endothelial growth factors A and C (VEGF-A and VEGF-C) conditions. Moreover, it remains unclear how these flow and growth factor conditions impact lymphatic sprouting. Methods: We developed a 3D human lymphatic vessel-on-chip that can generate four different flow conditions (no flow, luminal flow, interstitial flow, both luminal and interstitial flow) to allow an engineered, rudimentary LV to experience those flows and respond to them in VEGF-A/C. Results: We examined LEC junction discontinuities, lymphatic sprouting, LEC junction thicknesses, and cell contractility-dependent vessel diameters in the four different flow conditions in VEGF-A/C. We discovered that interstitial flow in VEGF-C generates discontinuous LEC junctions that may be similar to the button-like junctions with no lymphatic sprouting. However, interstitial flow or both luminal and interstitial flow stimulated lymphatic sprouting in VEGF-A, maintaining zipper-like LEC junctions. LEC junction thickness and cell contractility-dependent vessel diameters were not changed by those conditions. Conclusions: In this study, we provide an engineered lymphatic vessel platform that can generate four different flow regimes and reveal the roles of interstitial flow and VEGF-A/C for lymphatic sprouting and discontinuous junction formation. Supplementary Information: The online version contains supplementary material available at 10.1007/s12195-023-00780-0.

3.
J Biol Eng ; 16(1): 11, 2022 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-35578246

RESUMEN

Age-related macular degeneration (AMD) is a progressive, degenerative disease of the macula, leading to severe visual loss in the elderly population. There are two types of AMD: non-exudative ('dry') AMD and exudative ('wet') AMD. Non-exudative AMD is characterized by drusen formation and macular atrophy, while the blood vessels are not leaky. Exudative AMD is a more advanced form of the disease, featured with abnormal blood vessel growth and vascular leakage. Even though anti-angiogenic therapies have been effective in treating wet AMD by normalizing blood vessels, there is no treatment available to prevent or treat dry AMD. Currently, the mechanisms of drusen formation and macular atrophy in the dry AMD are poorly understood, in part because the currently available in vivo models of AMD could not decouple and isolate the complex biological and biophysical factors in the macular region for a detailed mechanism study, including the complement system, angiogenesis factors, extracellular matrix, etc. In the present review article, we describe the biological background of AMD and the key cells and structures in AMD, including retinal epithelium, photoreceptor, Bruch's membrane, and choriocapillaris. We also discuss pre-clinical animal models of AMD and in vivo tissue-engineered approaches, including cell suspension injection and organoid-derived cell sheet transplantation. We also discuss in vitro tissue-engineered models for AMD research. Specifically, we evaluate and compare currently available two- and three-dimensional AMD tissue-engineered models that mimic key anatomical players in AMD progression, including pathophysiological characteristics in Bruch's membrane, photoreceptor, and choriocapillaris. Finally, we discuss the limitation of current AMD models and future directions.

4.
iScience ; 24(3): 102163, 2021 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-33665579

RESUMEN

Bioelectrochemical systems (BESs) can fulfill the demand for renewable energy and wastewater treatment but still face significant challenges to improve their overall performance. Core efforts have been made to enhance the bioelectrode performance, yet, previous approaches are fragmented and have limited applicability, unable to flexibly adjust physicochemical and structural properties of electrodes for specific requirements in various applications. Here, we propose a facile electrode design strategy that integrates three-dimensional printing technology and functionalized modular electrode materials. A customized graphene-based electrode with hierarchical pores and functionalized components (i.e., ferric ions and magnetite nanoparticles) was fabricated. Owing to efficient mass and electron transfer, a high volumetric current density of 10,608 ± 1,036 A/m3 was achieved, the highest volumetric current density with pure Geobacter sulfurreducens to date. This strategy can be readily applied to existing BESs (e.g., microbial fuel cells and microbial electrosynthesis) and provide a feasibility for practical application.

5.
Biotechnol Bioeng ; 118(2): 1006-1012, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33022744

RESUMEN

As a precursor of graphene, graphene oxide (GO) exhibits excellent mechanical, thermal, and electrical properties, besides appreciable biocompatibility in tissue engineering applications. However, the current GO-3D fabrication technology is still in need of optimization and simplification to ensure fine architecture and reasonable mechanical properties, which would further promote the performance of GO as bio-scaffolds in cell or microorganism attachment and in material transformation. To address this issue, we proposed a GO ink, with appreciable rheological properties and excellent printing performance via high-speed centrifugation and ferric ion-assisted cross-linking. A woodpile structure with controllable micro-pores was produced by micro-extrusion-based 3D printing technology followed by an optimized freeze-drying process. Cellular adhesion and viability were verified by inoculation and culture of HepaRG cells using the fabricated GO 3D structure, thus suggesting ferric ion-assisted cross-linking and controllable pore distribution for improving the performance of the GO construct as a bio-scaffold for in vitro liver tissue models.


Asunto(s)
Grafito/química , Hidrogeles/química , Ensayo de Materiales , Impresión Tridimensional , Ingeniería de Tejidos , Andamios del Tejido/química , Línea Celular , Humanos
6.
Micromachines (Basel) ; 11(6)2020 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-32599818

RESUMEN

Glaucoma is a group of optic neuropathies characterized by the progressive degeneration of retinal ganglion cells (RGCs). Patients with glaucoma generally experience elevations in intraocular pressure (IOP), followed by RGC death, peripheral vision loss and eventually blindness. However, despite the substantial economic and health-related impact of glaucoma-related morbidity worldwide, the surgical and pharmacological management of glaucoma is still limited to maintaining IOP within a normal range. This is in large part because the underlying molecular and biophysical mechanisms by which glaucomatous changes occur are still unclear. In the present review article, we describe current tissue-engineered models of the intraocular space that aim to advance the state of glaucoma research. Specifically, we critically evaluate and compare both 2D and 3D-culture models of the trabecular meshwork and nerve fiber layer, both of which are key players in glaucoma pathophysiology. Finally, we point out the need for novel organ-on-a-chip models of glaucoma that functionally integrate currently available 3D models of the retina and the trabecular outflow pathway.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...