Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Opt Express ; 32(9): 16027-16039, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38859240

RESUMEN

We present the theory and experimental results of a microwave photonic (MWP) filter based instantaneous frequency measurement system. A quantum dash mode-locked laser is used as an optical frequency comb source. With up to 41 flat comb lines and a real-time feedback loop for comb shaping, a set of MWP filters with linear frequency responses for either linear unit or dB unit are experimentally demonstrated. The maximum measurement frequency can be up to 20 GHz limited by the available test-and-measurement instruments. By using one MWP filter, the root-mean-square error is 51∼66 MHz, which can be improved to 42.2 MHz for linear unit, and 30.7 MHz for dB unit by using two MWP filters together.

2.
Sci Prog ; 107(1): 368504231221407, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38314759

RESUMEN

Foggy images affect image analysis and measurement because of their low definition and blurred details. Despite numerous studies on haze in natural images in hazy environments, the recovery effect is not ideal for processing hazy images in sky areas. A dark channel priori technique for processing haze images with sky areas where atmospheric light values are misestimated and halo artefacts are produced, as well as an improved dark channel priori single-image defogging technique based on image segmentation and joint filtering, are proposed. First, an estimation method of the atmospheric illumination value using image segmentation is proposed to obtain the atmospheric illumination value. The probability density distribution function of the haze-grey image was constructed during image segmentation. The probability density distribution function of the grey image value, the K-means clustering technique, and the method for estimating atmospheric illumination values are combined to improve image segmentation techniques and achieve the segmentation of sky and non-sky areas in hazy images. Based on the segmentation threshold, the number of pixels in the sky and non-sky areas, as well as the normalisation results, were counted to calculate the atmospheric illumination values. Second, to address the halo artefact phenomenon, a method for optimising the image transmittance map using joint filtering is proposed. The image transmittance map was optimised by combining fast-guided filtering and weighted least-squares filtering to retain the edge information and smooth the gradient change of the internal region. Finally, gamma correction and automatic level optimisation are used to improve the brightness and contrast of the defogged images. The experimental results show that the proposed technique can effectively achieve sky segmentation. Compared to the traditional dark-channel prior technique, the proposed technique suppress halo artefacts and improve image detail recovery. Compared to other techniques, the proposed technique exhibited excellent performance in subjective and objective evaluations.

3.
Opt Express ; 32(1): 217-229, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38175050

RESUMEN

We investigate the capabilities and limitations of quantum-dash mode-locked lasers (QD-MLLDs) as optical frequency comb sources in coherent optical communication systems. We demonstrate that QD-MLLDs are on par with conventional single-wavelength narrow linewidth laser sources and can support high symbol rates and modulation formats. We manage to transmit 64 quadrature amplitude modulation (QAM) signals up to 80 GBd over 80 km of standard single-mode fiber (SSMF), which highlights the distinctive phase noise performance of the QD-MLLD. Using a 38.5 GHz (6 dB bandwidth) silicon photonic (SiP) modulator, we achieve a maximum symbol rate of 104 GBd with 16QAM signaling and a maximum net rate of 416 Gb/s per carrier in a single polarization setup and after 80 km-SSMF transmission. We also compare QD-MLLD performance with commercial narrow-linewidth integrable tunable laser assemblies (ITLAs) and explore their potential for use as local oscillators (LOs) and signal carriers. The QD-MLLD has 45 comb lines usable for transmission at a frequency spacing of 25 GHz, and an RF linewidth of 35 kHz.

4.
Appl Opt ; 62(32): 8696-8701, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-38037987

RESUMEN

We demonstrate photonic beamforming using a quantum-dash (QD) optical frequency comb (OFC) source. Thanks to the 25 GHz free spectral range (FSR) and up to 40 comb lines available from the QD OFC, we can implement phased antenna arrays (PAAs) with directional radiation and scanning. We consider two types of PAAs: a uniform linear array (ULA) and a uniform planar array (UPA). By selecting different comb lines with a programmable optical filter, we can tune the FSR of the OFC source and realize a discrete scanning function. We evaluate the beam squint of the ULAs, and the results show that we can achieve broadband operation. Finally, we show that we can achieve both directional radiation and scanning simultaneously using the UPA.

5.
Micromachines (Basel) ; 14(12)2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38138398

RESUMEN

We present here a performance comparison of quantum-dash (Qdash) semiconductor amplifiers (SOAs) with three, five, eight, and twelve InAs dash layers grown on InP substrates. Other than the number of Qdash layers, the structures were identical. The eight-layer Qdash SOA gave the highest amplified spontaneous emission power (4.3 dBm) and chip gain (26.4 dB) at 1550 nm, with a 300 mA CW bias current and at 25 °C temperature, while SOAs with fewer Qdash layers (for example, three-layer Qdash SOA), had a wider ASE bandwidth (90 nm) and larger 3 dB gain saturated output power (18.2 dBm) in a shorter wavelength range. The noise figure (NF) of the SOAs increased nearly linearly with the number of Qdash layers. The longest gain peak wavelength of 1570 nm was observed for the 12-layer Qdash SOA. The most balanced performance was obtained with a five-layer Qdash SOA, with a 25.4 dB small-signal chip gain, 15.2 dBm 3 dB output saturated power, and 5.7 dB NF at 1532 nm, 300 mA and 25 °C. These results are better than those of quantum well SOAs reported in a recent review paper. The high performance of InAs/InP Qdash SOAs with different Qdash layers shown in this paper could be important for many applications with distinct requirements under uncooled scenarios.

6.
Sci Rep ; 13(1): 19691, 2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-37951963

RESUMEN

The combined rock breaking method with the saw blade and conical pick is proposed to improve the rock breaking efficiency. The numerical simulation of combined rock breaking with the saw blade and conical pick is established to investigate the rock damage mechanism. And verified and modified the numerical simulation model with the rock breaking comprehensive test bench, the quantitative analysis error is less than 0.05, indicated quantitative analysis system is accuracy. The result indicated that the cutting parameters of the saw blade and conical pick affect the rock damage. And the cutting parameters of conical pick and structural parameters of rock plate have been studied to influence rock breaking volume. The research result could help optimize the cutting parameters of the saw blade and conical pick to improve the rock breaking efficiency.

7.
Opt Lett ; 48(12): 3179-3182, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37319056

RESUMEN

A simple polarization-insensitive coherent radio-over-fiber (RoF) link with increased spectrum efficiency and transmission capacity is proposed and demonstrated. Instead of using two polarization splitters (PBSs), two 90° hybrids, and four pairs of balanced photodetectors (PDs) in a conventional polarization-diversity coherent receiver (PDCR), a simplified PDCR with only one PBS, one optical coupler (OC), and two PDs is employed in the coherent RoF link. At the simplified receiver, a novel, to the best of our knowledge, digital signal processing (DSP) algorithm is proposed to achieve polarization-insensitive detection and demultiplexing of two spectrally overlapping microwave vector signals as well as the elimination of the joint phase noise originating from the transmitter and the local oscillator (LO) laser sources. An experiment is performed. The transmission and detection of two independent 16QAM microwave vector signals at identical microwave carrier frequencies of 3 GHz with a symbol rate of 0.5 GSym/s over a 25-km single-mode fiber (SMF) is demonstrated. Thanks to the spectrum superposition of the two microwave vector signals, the spectral efficiency as well as the data transmission capacity is increased.


Asunto(s)
Telecomunicaciones , Diseño de Equipo , Análisis de Falla de Equipo , Procesamiento de Señales Asistido por Computador
8.
Opt Lett ; 48(11): 2953-2956, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37262252

RESUMEN

We experimentally demonstrate a high-rate discretely modulated continuous-variable quantum key distribution over 80-km standard single-mode fiber with a 2.5 Gbaud, 16-symbol, two-ring constellation. With the help of well-designed digital signal processing algorithms, the excess noise of the system can be effectively suppressed. The achieved secret key rates are 49.02 Mbits/s, 11.86 Mbits/s, and 2.11 Mbits/s over 25-km, 50-km, and 80-km optical fiber, respectively, and achieve 67.4%, 70.0%, and 66.5% of the secret key rate performance of a Gaussian-modulated protocol. Our work shows that it is feasible to build a high-performance, long-distance continuous-variable quantum key distribution system with only a small constellation size.

9.
J Fungi (Basel) ; 9(6)2023 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-37367608

RESUMEN

The Complex of Proteins Associated with Set1 (COMPASS) methylates lysine K4 on histone H3 (H3K4) and is conserved from yeast to humans. Its subunits and regulatory roles in the meningitis-causing fungal pathogen Cryptococcus neoformans remain unknown. Here we identified the core subunits of the COMPASS complex in C. neoformans and C. deneoformans and confirmed their conserved roles in H3K4 methylation. Through AlphaFold modeling, we found that Set1, Bre2, Swd1, and Swd3 form the catalytic core of the COMPASS complex and regulate the cryptococcal yeast-to-hypha transition, thermal tolerance, and virulence. The COMPASS complex-mediated histone H3K4 methylation requires H2B mono-ubiquitination by Rad6/Bre1 and the Paf1 complex in order to activate the expression of genes specific for the yeast-to-hypha transition in C. deneoformans. Taken together, our findings demonstrate that putative COMPASS subunits function as a unified complex, contributing to cryptococcal development and virulence.

10.
Infect Dis Poverty ; 12(1): 20, 2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36932414

RESUMEN

BACKGROUND: Emerging fungal pathogens pose important threats to global public health. The World Health Organization has responded to the rising threat of traditionally neglected fungal infections by developing a Fungal Priority Pathogens List (FPPL). Taking the highest-ranked fungal pathogen in the FPPL, Cryptococcus neoformans, as a paradigm, we review progress made over the past two decades on its global burden, its clinical manifestation and management of cryptococcal infection, and its antifungal resistance. The purpose of this review is to drive research efforts to improve future diagnoses, therapies, and interventions associated with fungal infections. METHODS: We first reviewed trends in the global burden of HIV-associated cryptococcal infection, mainly based on a series of systematic studies. We next conducted scoping reviews in accordance with the guidelines described in the Preferred Reporting Items for Systematic Reviews and Meta-analyses extension for Scoping Reviews using PubMed and ScienceDirect with the keyword Cryptococcus neoformans to identify case reports of cryptococcal infections published since 2000. We then reviewed recent updates on the diagnosis and antifungal treatment of cryptococcal infections. Finally, we summarized knowledge regarding the resistance and tolerance of C. neoformans to approved antifungal drugs. RESULTS: There has been a general reduction in the estimated global burden of HIV-associated cryptococcal meningitis since 2009, probably due to improvements in highly active antiretroviral therapies. However, cryptococcal meningitis still accounts for 19% of AIDS-related deaths annually. The incidences of CM in Europe and North America and the Latin America region have increased by approximately two-fold since 2009, while other regions showed either reduced or stable numbers of cases. Unfortunately, diagnostic and treatment options for cryptococcal infections are limited, and emerging antifungal resistance exacerbates the public health burden. CONCLUSION: The rising threat of C. neoformans is compounded by accumulating evidence for its ability to infect immunocompetent individuals and the emergence of antifungal-resistant variants. Emphasis should be placed on further understanding the mechanisms of pathogenicity and of antifungal resistance and tolerance. The development of novel management strategies through the identification of new drug targets and the discovery and optimization of new and existing diagnostics and therapeutics are key to reducing the health burden.


Asunto(s)
Cryptococcus neoformans , Infecciones por VIH , Meningitis Criptocócica , Micosis , Humanos , Meningitis Criptocócica/tratamiento farmacológico , Meningitis Criptocócica/epidemiología , Meningitis Criptocócica/complicaciones , Antifúngicos/farmacología , Antifúngicos/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Micosis/complicaciones , Micosis/tratamiento farmacológico
11.
Cancer Imaging ; 23(1): 1, 2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36600283

RESUMEN

PURPOSE: A comparative retrospective study to assess the impact of PSMA Ligand PET/MRI ([68 Ga]-Ga-PSMA-11 and [18F]-F-PSMA-1007 PET/MRI) as a new method of target delineation compared to conventional imaging on whole-pelvis radiotherapy for high-risk prostate cancer (PCa). PATIENTS AND METHODS: Forty-nine patients with primary high-risk PCa completed the whole-pelvis radiotherapy plan based on PSMA PET/MRI and MRI. The primary endpoint compared the size and overlap of clinical target volume (CTV) and nodal gross tumour volume (GTVn) based on PSMA PET/MRI and MRI. The diagnostic performance of two methods for pelvic lymph node metastasis (PLNM) was evaluated. RESULTS: In the radiotherapy planning for high-risk PCa patients, there was a significant correlation between MRI-CTV and PET/MRI-CTV (P = 0.005), as well as between MRI-GTVn and PET/MRI-GTVn (P < 0.001). There are non-significant differences in the CTV and GTVn based on MRI and PET/MRI images (P = 0.660, P = 0.650, respectively). The conformity index (CI), lesion coverage factor (LCF) and Dice similarity coefficient (DSC) of CTVs were 0.999, 0.953 and 0.954. The CI, LCF and DSC of GTVns were 0.927, 0.284, and 0.32. Based on pathological lymph node analysis of 463 lymph nodes from 37 patients, the sensitivity, specificity of PET/MRI in the diagnosis of PLNM were 77.78% and 99.76%, respectively, which were higher than those of MRI (P = 0.011). Eight high-risk PCa patients who finished PSMA PET/MRI changed their N or M stage. CONCLUSION: The CTV delineated based on PET/MRI and MRI differ little. The GTVn delineated based on PET/MRI encompasses metastatic pelvic lymph nodes more accurately than MRI and avoids covering pelvic lymph nodes without metastasis. We emphasize the utility of PET/MRI fusion images in GTVn delineation in whole pelvic radiotherapy for PCa. The use of PSMA PET/MRI aids in the realization of more individual and precise radiotherapy for PCa.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Radioisótopos de Galio , Tomografía de Emisión de Positrones , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Imagen por Resonancia Magnética , Ácido Edético
12.
Opt Express ; 30(15): 27912-27925, 2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-36236950

RESUMEN

In continuous-variable quantum key distribution (CV-QKD), the key information are encoded on quadratures of the optical field, which are measured via balanced homodyne detector (BHD). The bandwidth of the BHD is one of key parameters for precise characterization of quantum states. We establish a theoretical model to analyze the impact of the BHD bandwidth and signal modulation patterns on the channel parameters estimation of CV-QKD systems. Based on the proposed model, the secure key rate of a practical CV-QKD system under different BHD bandwidths and signal modulation patterns are investigated. Our results show that insufficient BHD bandwidth will result in wrong estimate of the transmission loss and excess noise, which significantly affects the performance of CV-QKD systems. Given the BHD bandwidth, there exists an optimal signal repetition rate that maximizes the secure key rate. The BHD bandwidth requirement of the QKD system increases with the transmission distance for large duty cycle pulse. Furthermore, the root raised-cosine pulse signal modulation performs better than the square pulse signal modulation in general.

13.
Sci Rep ; 12(1): 17346, 2022 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-36245010

RESUMEN

Circular saw blades are widely used in stone processing. The circular saw blade cutting hard rock numerical simulation model based on ANSYS/LS-DYNA was established to investigate the complex dynamic problem in rock cutting. The failure mechanism of the rock and the influence of cutting parameters on the cutting force and rock fragments were studied by numerical simulation. The results demonstrated that the failure modes of the rock were mainly tensile failure with some shear failure and compressive failure. The cutting force and the number of fragments increased with the feed speed. With the increasing circular saw blade rotational speed, the cutting force and the number of fragments decreased and tended to stabilize. With the distance between the circular saw blades increasing, the cutting force and rock fragments number increase and then maintain basic stability, and when the distance between double circular saw blades reaches 25 mm, it will form a completed rock plate and the interaction of circular saw blades will decrease. The numerical simulation can accurately simulate rock breakage and force when a circular saw blade cuts rock.

14.
Cancer Imaging ; 22(1): 36, 2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35869521

RESUMEN

BACKGROUND: We aimed to assess the clinical value of 18F-PSMA-1007 and 68Ga-PSMA-11 PET/MRI in the gross tumor volume (GTV) delineation of radiotherapy for prostate cancer (PCa). METHODS: Sixty-nine patients were retrospectively enrolled (57 in the 18F subgroup and 12 in the 68Ga subgroup). Three physicians delineated the GTV and tumor length by the visual method and threshold method with thresholds of 30%, 40%, 50%, and 60% SUVmax. The volume correlation and differences in GTVs were assessed. The dice similarity coefficient (DSC) was applied to estimate the spatial overlap between GTVs. For 51 patients undergoing radical prostatectomy, the tumor length (Lpath) of the maximum area was measured, and compared with the longest tumor length obtained based on the images (LMRI, LPET/MRI, LPET, LPET30%, LPET40%, LPET50%, LPET60%) to determine the best delineation method. RESULTS: In the 18F subgroup, (1) GTV-PET/MRI (p < 0.001) was significantly different from the reference GTV-MRI. DSC between them was > 0.7. (2) GTV-MRI (R2 = 0.462, p < 0.05) was the influencing factor of DSC. In the 68Ga subgroup, (1) GTV-PET/MRI (p < 0.05) was significantly different from the reference GTV-MRI. DSC between them was > 0.7. (2) There was a significant correlation between GTV-MRI (r = 0.580, p < 0.05) and DSC. The longest tumor length measured by PET/MRI was in good agreement with that measured by histopathological analysis in both subgroups. CONCLUSION: It is feasible to visually delineate GTV on PSMA PET/MRI in PCa radiotherapy, and we emphasize the utility of PET/MRI fusion images in GTV delineation. In addition, the overlap degree was the highest between GTV-MRI and GTV-PET/MRI, and it increased with increasing volume.


Asunto(s)
Radioisótopos de Galio , Neoplasias de la Próstata , Isótopos de Galio , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Niacinamida/análogos & derivados , Oligopéptidos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Estudios Retrospectivos , Carga Tumoral
15.
Opt Lett ; 47(5): 1133-1136, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35230309

RESUMEN

We demonstrate a reconfigurable microwave photonic (MWP) filter using a quantum dash (QDash) mode-locked laser (MLL) that can generate an optical frequency comb (OFC) with ∼50 comb lines and a free spectral range of 25 GHz. Thanks to the large number of comb lines, the MWP filter responses can be easily programmed by tailoring the OFC spectrum. We implement MWP filter responses with Gaussian, sinc, flat-top, and multiple peaks, as well as demonstrate that tuning of the central frequency. We achieve a minimum 3 dB bandwidth of ∼100 MHz for a sinc-shaped MWP filter, while the maximum out-of-band rejection can be up to ∼30 dB with Gaussian apodization. Our results show that the QDash-MLL is a promising OFC source for developing integrated and reconfigurable MWP filters.

16.
Opt Express ; 30(3): 3205-3214, 2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35209585

RESUMEN

Chip-scale optical frequency comb sources are ideal compact solutions to generate high speed optical pulses for applications in wavelength division multiplexing (WDM) and high-speed optical signal processing. Our previous studies have concentrated on the use of quantum dash based lasers, but here we present results from an InAs/InP quantum dot (QDot) C-band passively mode-locked laser (MLL) for frequency comb generation. By using this single-section QDot-MLL we demonstrate an aggregate line rate of 12.544 Tbit/s 16QAM data transmission capacity for both back-to-back (B2B) and over 100-km of standard single mode fiber (SSMF). This finding highlights the viability for InAs/InP QDot lasers to be used as a low-cost optical source for large-scale networks.

17.
Sci Prog ; 105(1): 368504221079191, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35188834

RESUMEN

To improve the conical pick cutting performance by per cutting to the free surface. The cutting performance of rock and rock plate breaking are investigated by theoretical and experimental methods. Analyzed the fracture position of the rock plate with constrained one side by the pick to study the effect of rock properties and the rock plate structural parameters on cutting force. The results indicated that the rock plate fracture is mainly from the constrained side and center of the rock plate. The cutting force of the conical pick is significantly affected by the rock plate structural parameters and the constraint sides of the rock plate number. The cutting force increases obviously with the increase of plate thickness, cutting point depth, and the rock uniaxial compressive strength. However, the influence of rock plate constrains sides number is opposite. It provides a basis for improving the cutting performance of pick and predicting the rock plate fracture.

18.
Entropy (Basel) ; 25(1)2022 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-36673221

RESUMEN

We propose a multidimensional reconciliation encoding algorithm based on a field-programmable gate array (FPGA) with variable data throughput that enables quantum key distribution (QKD) systems to be adapted to different throughput requirements. Using the circulatory structure, data flow in the most complex pipeline operation in the same time interval, which enables the structural multiplexing of the algorithm. We handle the calculation and storage of eight-dimensional matrices cleverly to conserve resources and increase data processing speed. In order to obtain the syndrome more efficiently, we designed a simplified algorithm according to the characteristics of the FPGA and parity-check matrix, which omits the unnecessary operation of matrix multiplication. The simplified algorithm could adapt to different rates. We validated the feasibility and high speed of the algorithm by implementing the multidimensional reconciliation encoding algorithm on a Xilinx Virtex-7 FPGA. Our simulation results show that the maximum throughput could reach 4.88 M symbols/s.

19.
Sci Prog ; 104(4): 368504211050293, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34842471

RESUMEN

The conical pick is the most crucial tool of roadheader for breaking rock, establishing the conical pick cutting rock and conical pick fatigue life numerical simulation models to investigate the influence of cutting parameters on rock damage, average peak cutting force, specific cutting energy and the conical pick fatigue life. The research results indicate that the width and depth of rock damage increase with increasing cutting depth and cutting speed. The average peak cutting force and the specific cutting energy have the same changing tendency. The changing trend of conical pick fatigue life and conical pick stress is opposite relationship. The optimum cutting angle of the conical pick cutting rock is 45°. Applying the research results for guiding the optimization of the cutting parameters reduces the specific cutting energy and stress and improves the conical pick fatigue life.

20.
Cancer Manag Res ; 13: 5383-5389, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34262346

RESUMEN

PURPOSE: Hybrid PET/MRI has been increasingly incorporated into the practice of radiation oncologists since it contains both anatomical and biological data and may bring about personalized radiation plans for each patient. The objective of this study was to evaluate the feasibility of GTV delineation from hybrid PET/MRI compared with that from current-practice MRI during radiotherapy planning in patients with colorectal liver metastases. PATIENTS AND METHODS: Twenty-four patients (thirty lesions) with colorectal liver metastases were prospectively enrolled in this study. Three physicians delineated the target volume with the most popular delineating methods-the visual method. First of all, differences among the three observers were assessed. The difference and correlation of GTV values obtained by MRI, PET, and hybrid PET/MRI were subjected to statistical analysis afterwards. Finally, the dice similarity coefficient (DSC) was calculated to assess the spatial overlap. Based on the value of DSC, we also evaluate the correlation between DSC and tumor size. GTV-MRI was set as a reference. RESULTS: There was no significant difference among observers in GTV-MRI (F=0.118, p=0.889), GTV-PET (F=0.070, p=0.933) and GTV-PET/MRI (F=0.40, p=0.961). 83.33% of GTV-PET/MRI and 63.33% of GTV-PET were larger than the reference GTV-MRI. Statistical analysis revealed that GTV-PET/MRI (p<0.001) and GTV-PET (p<0.05) diverged statistically significantly from GTV-MRI. GTV-PET (r=0.992, p<0.001) and GTV-PET/MRI (r=0.997, p<0.001) were significantly related to GTV-MRI. The average DSC value between GTV-MRI and GTV-PET was 0.51 (range 0-0.90) and that between GTV-MRI and GTV-PET/MRI was 0.72 (range 0.42-0.90). There was a positive correlation between the DSC and GTV-MRI (r=0.851, p<0.05). CONCLUSION: With the database used, there is good agreement among observers. Hybrid PET/MRI in colorectal liver metastases radiotherapy may affect the GTV delineation. Moreover, the overlap degree between GTV-MRI and GTV-PET/MRI is higher and increases with volume.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...