1.
J Thorac Imaging ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38712920

RESUMEN

PURPOSE: We investigated spatial resolution loss away from isocenter for a prototype deep silicon photon-counting detector (PCD) CT scanner and compare with a clinical energy-integrating detector (EID) CT scanner. MATERIALS AND METHODS: We performed three scans on a wire phantom at four positions (isocenter, 6.7, 11.8, and 17.1 cm off isocenter). The acquisition modes were 120 kV EID CT, 120 kV high-definition (HD) EID CT, and 120 kV PCD CT. HD mode used double the projection view angles per rotation as the "regular" EID scan mode. The diameter of the wire was calculated by taking the full width of half max (FWHM) of a profile drawn over the radial and azimuthal directions of the wire. Change in wire diameter appearance was assessed by calculating the ratio of the radial and azimuthal diameter relative to isocenter. t tests were used to make pairwise comparisons of the wire diameter ratio with each acquisition and mean ratios' difference from unity. RESULTS: Deep silicon PCD CT had statistically smaller (P<0.05) changes in diameter ratio for both radial and azimuthal directions compared with both regular and HD EID modes and was not statistically different from unity (P<0.05). Maximum increases in FWMH relative to isocenter were 36%, 12%, and 1% for regular EID, HD EID, and deep silicon PCD, respectively. CONCLUSION: Deep silicon PCD CT exhibits less change in spatial resolution in both the radial and azimuthal directions compared with EID CT.

2.
Br J Radiol ; 97(1154): 292-305, 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38308038

RESUMEN

Metabolic syndrome, which affects around a quarter of adults worldwide, is a group of metabolic abnormalities characterized mainly by insulin resistance and central adiposity. It is strongly correlated with cardiovascular and all-cause mortality. Early identification of the changes induced by metabolic syndrome in target organs and timely intervention (eg, weight reduction) can decrease morbidity and mortality. Imaging can monitor the main components of metabolic syndrome and identify early the development and progression of its sequelae in various organs. In this review, we discuss the imaging features across different modalities that can be used to evaluate changes due to metabolic syndrome, including fatty deposition in different organs, arterial stiffening, liver fibrosis, and cardiac dysfunction. Radiologists can play a vital role in recognizing and following these target organ injuries, which in turn can motivate lifestyle modification and therapeutic intervention.


Asunto(s)
Síndrome Metabólico , Adulto , Humanos , Síndrome Metabólico/diagnóstico por imagen , Obesidad/complicaciones , Cirrosis Hepática/complicaciones
3.
Radiol Imaging Cancer ; 6(2): e230080, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38334471

RESUMEN

Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.6%] women) with 29 retroperitoneal tumors treated over 22 MWA procedures. Hydrodissection (0.9% saline with 2% iohexol) was injected in 17 of 22 (77.3%) procedures to protect nontarget anatomy. The primary outcomes evaluated were local tumor progression (LTP) and complication rates. Oncologic outcomes, including overall survival (OS), progression-free survival (PFS), and treatment-free interval (TFI), were examined as secondary outcome measures. Results Median follow-up was 18 months (range = 0.5-113). Hydrodissection was successful in displacing nontarget anatomy in 16 of 17 (94.1%) procedures. The LTP rate was 3.4% (one of 29; 95% CI: 0.1, 17.8) per tumor and 5.3% (one of 19; 95% CI: 0.1, 26.0) per patient. The overall complication rate per patient was 15.8% (three of 19), including two minor complications and one major complication. The OS rate at 1, 2, and 3 years was 81.8%, 81.8%, and 72.7%, respectively, with a median OS estimated at greater than 7 years. There was no evidence of a difference in OS (P = .34) and PFS (P = .56) between patients with renal cell carcinoma (six of 19 [31.6%]) versus other tumors (13 of 19 [68.4%]) and patients treated with no evidence of disease (15 of 22 [68.2%]) versus patients with residual tumors (seven of 22 [31.8%]). Median TFI was 18 months (range = 0.5-108). Conclusion Treatment of retroperitoneal tumors with MWA combined with hydrodissection provided high rates of local control, prolonged systemic therapy-free intervals, and few serious complications. Keywords: Ablation Techniques (ie, Radiofrequency, Thermal, Chemical), Retroperitoneum, Microwave Ablation, Hydrodissection © RSNA, 2024.


Asunto(s)
Neoplasias Renales , Neoplasias Retroperitoneales , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Neoplasias Retroperitoneales/diagnóstico por imagen , Neoplasias Retroperitoneales/radioterapia , Neoplasias Retroperitoneales/cirugía , Resultado del Tratamiento , Microondas/uso terapéutico , Estudios Retrospectivos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía
4.
Radiology ; 310(1): e230453, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38259204

RESUMEN

Background Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States. Biopsies were performed with needles that were 18 gauge or larger, with a comparison group of biopsies with needles smaller than 18 gauge. The primary outcome was significant bleeding after the procedure, defined by the presence of bleeding at CT performed within 30 days or angiography and/or surgery performed to manage the bleeding. Categorical variables were compared using the χ2 test and medians were compared using the Mann-Whitney test. Results A total of 239 patients (median age, 63 years; IQR, 50-71 years; 116 of 239 [48.5%] female patients) underwent splenic biopsy with an 18-gauge or smaller needle and 139 patients (median age, 58 years [IQR, 49-69 years]; 66 of 139 [47.5%] female patients) underwent biopsy with a needle larger than 18 gauge. Bleeding was detected in 20 of 239 (8.4%) patients in the 18-gauge or smaller group and 11 of 139 (7.9%) in the larger than 18-gauge group. Bleeding was treated in five of 239 (2.1%) patients in the 18-gauge or smaller group and one of 139 (1%) in the larger than 18-gauge group. No deaths related to the biopsy procedure were recorded during the study period. Patients with bleeding after biopsy had smaller lesions compared with patients without bleeding (median, 2.1 cm [IQR, 1.6-5.4 cm] vs 3.5 cm [IQR, 2-6.8 cm], respectively; P = .03). Patients with a history of lymphoma or leukemia showed a lower incidence of bleeding than patients without this history (three of 90 [3%] vs 28 of 288 [9.7%], respectively; P = .05). Conclusion Bleeding after splenic biopsy with a needle 18 gauge or larger was similar to biopsy with a needle smaller than 18 gauge and seen in 8% of procedures overall, with 2% overall requiring treatment. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grant in this issue.


Asunto(s)
Biopsia Guiada por Imagen , Agujas , Bazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía , Biopsia Guiada por Imagen/efectos adversos , Agujas/efectos adversos , Agujas/estadística & datos numéricos , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Bazo/patología , Anciano
5.
Abdom Radiol (NY) ; 48(11): 3322-3331, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37644134

RESUMEN

PURPOSE: To compare MiraLAX, a hypo-osmotic lavage, and magnesium citrate (MgC), a hyper-osmotic agent for bowel preparation at CTC. METHODS: 398 total screening CTC studies were included in this retrospective, single institution study. 297 underwent preparation with a double-dose MgC regimen (mean age, 61 ± 5.5 years; 142 male/155 female) and 101 with 8.3 oz (equivalent to 238 g PEG) of MiraLAX (mean age, 60 ± 9.6 years; 45 male/56 female). Oral contrast for tagging purposes was utilized in both regimens. Studies were retrospectively analyzed for residual fluid volume and attenuation by automated analysis, as well for subjective oral contrast coating of the normal colonic wall and polyps. 50 patients underwent successive CTC studies utilizing each agent (mean, 6.1 ± 1.7 years apart), allowing for intra-patient comparison. Chi-squared, Fisher's exact, McNemar, and t-tests were used for data comparison. RESULTS: Residual fluid volume (as percentage of total colonic volume) and fluid density was 7.2 ± 4.2% and 713 ± 183 HU for the MgC cohort and 8.7 ± 3.8% and 1044 HU ± 274 for the MiraLAX cohort, respectively (p = 0.001 and p < 0.001, respectively). Similar results were observed for the intra-patient cohort. Colonic wall coating negatively influencing interpretation was noted in 1.7% of MgC vs. 6.9% of MiraLAX examinations (p = 0.008). Polyps were detected in 12% of all MgC vs. 16% of all MiraLAX CTCs (p = 0.29). CONCLUSION: CTC bowel preparation with the hypo-osmotic MiraLAX agent appears to provide acceptable diagnostic quality that is comparable to the hyper-osmotic MgC agent, especially when factoring in patient safety and tolerance.

6.
J Vasc Interv Radiol ; 34(11): 1986-1996, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37481064

RESUMEN

PURPOSE: To compare the safety and efficacy of histotripsy with cryoablation in a chronic human-scale normal porcine kidney model. MATERIALS AND METHODS: Eighteen female domestic swine were divided evenly into histotripsy and cryoablation treatment arms. A planned 2-3 cm diameter treatment was performed under ultrasound (histotripsy) or ultrasound and computed tomography (CT) guidance (cryoablation). Contrast-enhanced CT and serum blood analysis were performed immediately postprocedure and on day 7, with either immediate killing (n = 3) or continued survival to day 30 (n = 6), at which time contrast-enhanced CT, serum blood analysis, and necropsy were performed. Animal welfare, treatment zone appearance, procedure-related adverse events, and histopathology of the treatment zones and surrounding tissues were assessed. RESULTS: Histotripsy treatment zones (mean ±standard deviation diameters, 2.7 ± 0.12 × 2.4 ± 0.19 × 2.4 ± 0.26 cm; volume, 8.3 ± 1.9 cm3) were larger than cryoablation zones (mean diameters, 2.2 ± 0.19 × 1.9 ± 0.13 × 1.7 ± 0.19 cm; volume, 3.9 ± 0.8 cm3; P < .001). At 30 days, histotripsy and cryoablation treatment zone volumes decreased by 96% and 83% on CT, respectively (P < .001). Perirenal hematomas were present after 8 of 9 (89%) cryoablation (mean volume, 22.2 cm3) and 1 of 9 (11%, P < .001) histotripsy (volume, 0.4 cm3) procedures, with active arterial extravasation in 4 of 9 (44%) cryoablation and no histotripsy animals (P = .206). All 9 histotripsy animals and 5 of 9 (56%) cryoablation animals had collecting system debris (P = .042). Changes in serum creatinine were similar between the groups (P = .321). CONCLUSIONS: Other than a higher rate of bleeding after cryoablation, the safety and early efficacy of histotripsy and cryoablation were comparable for creating treatment zones in a chronic normal porcine kidney model.


Asunto(s)
Criocirugía , Neoplasias Renales , Humanos , Porcinos , Femenino , Animales , Criocirugía/efectos adversos , Criocirugía/métodos , Riñón/patología , Neoplasias Renales/patología , Tomografía Computarizada por Rayos X , Hemorragia Gastrointestinal/etiología , Resultado del Tratamiento
7.
Radiographics ; 43(8): e230025, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37471245

RESUMEN

Penile malignancy is the third most common male-specific genitourinary malignancy, with squamous cell carcinoma representing the most common histologic type. Squamous cell carcinoma is an epithelial malignancy, frequently developing from the mucosal surfaces of the foreskin, glans, and coronal sulcus and manifesting as a distal infiltrative or ulcerated mass. This typically occurs in men from the 6th to 8th decades of life, and risk factors include human papillomavirus, phimosis, presence of foreskin and poor hygiene, chronic inflammatory conditions such as lichen sclerosus, trauma, and smoking. Primary urethral malignancies including urothelial carcinoma and adenocarcinoma can occur but may lack this distal predilection. Sarcoma, melanoma, leukemia or lymphoma, and metastatic disease are less common sources of penile malignancy. Because of the sensitive nature of penile malignancies, there may be delays in seeking care and in subsequent diagnosis. Recently, the staging guidelines for penile cancer have been updated concurrently with a shift toward more penile-preserving therapies, which have led to a larger role of imaging in diagnosis, staging, and treatment planning for penile malignancies. A variety of imaging modalities may play a role in the identification and staging of penile malignancy, including an increased use of MRI for local staging of tumors, CT and PET/CT for identification of nodal and distant disease, and US for image-guided biopsy. The authors discuss an imaging approach to a spectrum of penile malignancies, with an emphasis on radiologic and pathologic correlation and how knowledge of normal tissue types and anatomic structures can aid in the diagnosis and staging of these tumors. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.

8.
AJR Am J Roentgenol ; 221(5): 611-619, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37377359

RESUMEN

BACKGROUND. Splenomegaly historically has been assessed on imaging by use of potentially inaccurate linear measurements. Prior work tested a deep learning artificial intelligence (AI) tool that automatically segments the spleen to determine splenic volume. OBJECTIVE. The purpose of this study is to apply the deep learning AI tool in a large screening population to establish volume-based splenomegaly thresholds. METHODS. This retrospective study included a primary (screening) sample of 8901 patients (4235 men, 4666 women; mean age, 56 ± 10 [SD] years) who underwent CT colonoscopy (n = 7736) or renal donor CT (n = 1165) from April 2004 to January 2017 and a secondary sample of 104 patients (62 men, 42 women; mean age, 56 ± 8 years) with end-stage liver disease who underwent contrast-enhanced CT performed as part of evaluation for potential liver transplant from January 2011 to May 2013. The automated deep learning AI tool was used for spleen segmentation, to determine splenic volumes. Two radiologists independently reviewed a subset of segmentations. Weight-based volume thresholds for splenomegaly were derived using regression analysis. Performance of linear measurements was assessed. Frequency of splenomegaly in the secondary sample was determined using weight-based volumetric thresholds. RESULTS. In the primary sample, both observers confirmed splenectomy in 20 patients with an automated splenic volume of 0 mL; confirmed incomplete splenic coverage in 28 patients with a tool output error; and confirmed adequate segmentation in 21 patients with low volume (< 50 mL), 49 patients with high volume (> 600 mL), and 200 additional randomly selected patients. In 8853 patients included in analysis of splenic volumes (i.e., excluding a value of 0 mL or error values), the mean automated splenic volume was 216 ± 100 [SD] mL. The weight-based volumetric threshold (expressed in milliliters) for splenomegaly was calculated as (3.01 × weight [expressed as kilograms]) + 127; for weight greater than 125 kg, the splenomegaly threshold was constant (503 mL). Sensitivity and specificity for volume-defined splenomegaly were 13% and 100%, respectively, at a true craniocaudal length of 13 cm, and 78% and 88% for a maximum 3D length of 13 cm. In the secondary sample, both observers identified segmentation failure in one patient. The mean automated splenic volume in the 103 remaining patients was 796 ± 457 mL; 84% (87/103) of patients met the weight-based volume-defined splenomegaly threshold. CONCLUSION. We derived a weight-based volumetric threshold for splenomegaly using an automated AI-based tool. CLINICAL IMPACT. The AI tool could facilitate large-scale opportunistic screening for splenomegaly.

9.
Abdom Radiol (NY) ; 48(10): 3050-3062, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37369923

RESUMEN

PURPOSE: To describe and update stercoral colitis clinical risk factors, relative frequency, location, and CT imaging features correlated with surgical and pathological results. METHODS: CT reports over a 5-year period (05/2017-05/2022) at a single medical center were searched. Main inclusion criteria were luminal distention with formed stool, wall thickening, and surrounding inflammation. Positive cases were graded as mild (early or developing stercoral colitis) versus moderate-to-severe based on CT findings. Medical records were reviewed for risk factors and outcome data in moderate-to-severe cases. P-values were tabulated for comparison. RESULTS: 545 total cases (71 (60, 82) years, 278 males) were identified on CT, including 452 mild (82.9%) and 93 moderate-to-severe cases (17%, 67 (55, 79) years, 48 females). Twenty cases showed evidence of perforation (3.7% total cohort, 22% moderate-to-severe cohort). Diagnosis as an incidental finding was frequent (46.0% of mild cases). Most cases involved the rectum (97.6% of mild cohort and 69% of moderate-to-severe cohort). The sigmoid was involved in 31% of moderate-to-severe cases, but 95% of the perforated subcohort (19/20, 13/20 without rectal involvement). Among the moderate-to-severe cohort, perforation was associated with slightly increased wall thickness (6.4 vs. 5.7 mm, p = 0.03), opioid use (50 vs. 23%, p = 0.04), and disease-specific mortality (11 vs. 0%, p =0.04). Perforation was less associated with major neurocognitive disorders (20 vs. 60%, p = 0.003), institutionalized status (5 vs. 38%, p = 0.005), and a prescribed bowel regimen (30 vs. 63%, p = 0.01). CONCLUSION: Stercoral colitis may be under-reported. Perforation tends to favor sigmoid involvement and a less traditional patient cohort.


Asunto(s)
Colitis Isquémica , Impactación Fecal , Masculino , Femenino , Humanos , Impactación Fecal/complicaciones , Impactación Fecal/diagnóstico , Colitis Isquémica/complicaciones , Recto , Tomografía Computarizada por Rayos X , Factores de Riesgo
10.
Acad Radiol ; 30(10): 2340-2349, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37380534

RESUMEN

RATIONALE AND OBJECTIVES: Syringeless power injectors obviate the need for reloading iodinated contrast media (ICM) and plastic consumable pistons between exams. This study evaluates the potential time and material waste (ICM, plastic, saline, and total) saved using a multi-use syringeless injector (MUSI) compared to a single-use syringe-based injector (SUSI). MATERIALS AND METHODS: Two observers recorded technologist time spent using a SUSI and a MUSI over three clinical workdays. CT technologists (n = 15) were polled on their experience between the systems using a 5-point Likert scale survey. ICM, plastic, and saline waste data from each system were collected. A mathematical model was created to estimate total and categorical waste from each injector system over a 16-week period. RESULTS: On average, CT technologists spent 40.5 seconds less per exam with MUSI compared to SUSI (p < .001). Technologists rated MUSI work efficiency, user-friendliness, and overall satisfaction (strongly or somewhat improved) higher relative to SUSI (p < .05). Iodine waste was 31.3 L and 0.0 L for SUSI and MUSI, respectively. Plastic waste was 467.7 kg and 71.9 kg for SUSI and MUSI, respectively. Saline waste was 43.3 L and 52.5 L for SUSI and MUSI, respectively. Total waste was 555.0 kg and 124.4 kg for SUSI and MUSI respectively. CONCLUSION: Switching from SUSI to MUSI resulted in a 100%, 84.6%, and 77.6% reduction in ICM, plastic, and total waste. This system may fortify institutional endeavors toward green radiology initiatives. The potential time saved administering contrast using MUSI may improve CT technologist efficiency.


Asunto(s)
Jeringas , Tomografía Computarizada por Rayos X , Humanos , Flujo de Trabajo , Tomografía Computarizada por Rayos X/métodos , Inyecciones , Medios de Contraste
11.
AJR Am J Roentgenol ; 221(6): 736-746, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37341181

RESUMEN

BACKGROUND. Closure of a GE Healthcare facility in Shanghai, China, in 2022 disrupted the iodinated contrast media supply. Technologic advances have addressed limitations associated with the use of pulmonary MRA for diagnosis of pulmonary embolism (PE). OBJECTIVE. The purpose of this study was to describe a single institution's experience in the use of pulmonary MRA as an alternative to CTA for the diagnosis of PE in the general population during the iodinated contrast media shortage in 2022. METHODS. This retrospective single-center study included all CTA and MRA examinations performed to exclude PE from April 1 through July 31 (18 weekly periods) in 2019 (before the COVID-19 pandemic and contrast media shortage), 2021 (during the pandemic but before the shortage), and 2022 (during both the pandemic and the shortage). From early May through mid-July of 2022, MRA served as the preferred test for PE diagnosis, to preserve iodinated contrast media. CTA and MRA reports were reviewed. The total savings in iodinated contrast media volume resulting from preferred use of MRA was estimated. RESULTS. The study included 4491 examinations of 4006 patients (mean age, 57 ± 18 [SD] years; 1715 men, 2291 women): 1245 examinations (1111 CTA, 134 MRA) in 2019, 1547 examinations (1403 CTA, 144 MRA) in 2021, and 1699 examinations (1282 CTA, 417 MRA) in 2022. In 2022, the number of MRA examinations was four (nine when normalized to a 7-day period) in week 1, and this number increased to a maximum of 63 in week 10 and then decreased to 10 in week 18. During weeks 8-11, more MRA examinations (range, 45-63 examinations) than CTA examinations (range, 27-46 examinations) were performed. In 2022, seven patients with negative MRA underwent subsequent CTA within 2 weeks; CTA was negative in all cases. In 2022, 13.9% of CTA examinations (vs 10.3% of MRA examinations) were reported as having limited image quality. The estimated 4-month savings resulting from preferred use of MRA in 2022, under the assumption of uniform simple linear growth in CTA utilization annually and a CTA dose of 1 mL/kg, was 27 L of iohexol (350 mg I/mL). CONCLUSION. Preferred use of pulmonary MRA for PE diagnosis in the general population helped to conserve iodinated contrast media during the 2022 shortage. CLINICAL IMPACT. This single-center experience shows pulmonary MRA to be a practical substitute for pulmonary CTA in emergency settings.


Asunto(s)
Medios de Contraste , Embolia Pulmonar , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Pandemias , Angiografía por Resonancia Magnética/métodos , China , Embolia Pulmonar/diagnóstico por imagen
12.
J Comput Assist Tomogr ; 47(3): 429-436, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37185007

RESUMEN

BACKGROUND: Little guidance exists on how to stratify radiation dose according to diagnostic task. Changing dose for different cancer types is currently not informed by the American College of Radiology Dose Index Registry dose survey. METHODS: A total of 9602 patient examinations were pulled from 2 National Cancer Institute designated cancer centers. Computed tomography dose (CTDI vol ) was extracted, and patient water equivalent diameter was calculated. N-way analysis of variance was used to compare the dose levels between 2 protocols used at site 1, and three protocols used at site 2. RESULTS: Sites 1 and 2 both independently stratified their doses according to cancer indications in similar ways. For example, both sites used lower doses ( P < 0.001) for follow-up of testicular cancer, leukemia, and lymphoma. Median dose at median patient size from lowest to highest dose level for site 1 were 17.9 (17.7-18.0) mGy (mean [95% confidence interval]) and 26.8 (26.2-27.4) mGy. For site 2, they were 12.1 (10.6-13.7) mGy, 25.5 (25.2-25.7) mGy, and 34.2 (33.8-34.5) mGy. Both sites had higher doses ( P < 0.001) between their routine and high-image-quality protocols, with an increase of 48% between these doses for site 1 and 25% for site 2. High-image-quality protocols were largely applied for detection of low-contrast liver lesions or subtle pelvic pathology. CONCLUSIONS: We demonstrated that 2 cancer centers independently choose to stratify their cancer doses in similar ways. Sites 1 and 2 dose data were higher than the American College of Radiology Dose Index Registry dose survey data. We thus propose including a cancer-specific subset for the dose registry.


Asunto(s)
Radiología , Neoplasias Testiculares , Masculino , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Sistema de Registros
13.
AJR Am J Roentgenol ; 221(4): 539-547, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37255042

RESUMEN

BACKGROUND. Variable beam hardening based on patient size causes variation in CT numbers for energy-integrating detector (EID) CT. Photon-counting detector (PCD) CT more accurately determines effective beam energy, potentially improving CT number reliability. OBJECTIVE. The purpose of the present study was to compare EID CT and deep silicon PCD CT in terms of both the effect of changes in object size on CT number and the overall accuracy of CT numbers. METHODS. A phantom with polyethylene rings of varying sizes (mimicking patient sizes) as well as inserts of different materials was scanned on an EID CT scanner in single-energy (SE) mode (120-kV images) and in rapid-kilovoltage-switching dual-energy (DE) mode (70-keV images) and on a prototype deep silicon PCD CT scanner (70-keV images). ROIs were placed to measure the CT numbers of the materials. Slopes of CT number as a function of object size were computed. Materials' ideal CT number at 70 keV was computed using the National Institute of Standards and Technology XCOM Photon Cross Sections Database. The root mean square error (RMSE) between measured and ideal numbers was calculated across object sizes. RESULTS. Slope (expressed as Hounsfield units per centimeter) was significantly closer to zero (i.e., less variation in CT number as a function of size) for PCD CT than for SE EID CT for air (1.2 vs 2.4 HU/cm), water (-0.3 vs -1.0 HU/cm), iodine (-1.1 vs -4.5 HU/cm), and bone (-2.5 vs -10.1 HU/cm) and for PCD CT than for DE EID CT for air (1.2 vs 2.8 HU/cm), water (-0.3 vs -1.0 HU/cm), polystyrene (-0.2 vs -0.9 HU/cm), iodine (-1.1 vs -1.9 HU/cm), and bone (-2.5 vs -6.2 HU/cm) (p < .05). For all tested materials, PCD CT had the smallest RMSE, indicating CT numbers closest to ideal numbers; specifically, RMSE (expressed as Hounsfield units) for SE EID CT, DE EID CT, and PCD CT was 32, 44, and 17 HU for air; 7, 8, and 3 HU for water; 9, 10, and 4 HU for polystyrene; 31, 37, and 13 HU for iodine; and 69, 81, and 20 HU for bone, respectively. CONCLUSION. For numerous materials, deep silicon PCD CT, in comparison with SE EID CT and DE EID CT, showed lower CT number variability as a function of size and CT numbers closer to ideal numbers. CLINICAL IMPACT. Greater reliability of CT numbers for PCD CT is important given the dependence of diagnostic pathways on CT numbers.


Asunto(s)
Yodo , Silicio , Humanos , Reproducibilidad de los Resultados , Poliestirenos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Fotones , Agua
14.
Cancers (Basel) ; 15(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37173966

RESUMEN

Scientific understanding of how the immune microenvironment interacts with renal cell carcinoma (RCC) has substantially increased over the last decade as a result of research investigations and applying immunotherapies, which modulate how the immune system targets and eliminates RCC tumor cells. Clinically, immune checkpoint inhibitor therapy (ICI) has revolutionized the treatment of advanced clear cell RCC because of improved outcomes compared to targeted molecular therapies. From an immunologic perspective, RCC is particularly interesting because tumors are known to be highly inflamed, but the mechanisms underlying the inflammation of the tumor immune microenvironment are atypical and not well described. While technological advances in gene sequencing and cellular imaging have enabled precise characterization of RCC immune cell phenotypes, multiple theories have been suggested regarding the functional significance of immune infiltration in RCC progression. The purpose of this review is to describe the general concepts of the anti-tumor immune response and to provide a detailed summary of the current understanding of the immune response to RCC tumor development and progression. This article describes immune cell phenotypes that have been reported in the RCC microenvironment and discusses the application of RCC immunophenotyping to predict response to ICI therapy and patient survival.

15.
J Comput Assist Tomogr ; 47(4): 621-628, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36944097

RESUMEN

PURPOSES: The aims of the study are to identify factors contributing to computed tomography (CT) trauma scan turnaround time variation and to evaluate the effects of an automated intervention on time metrics. METHODS: Throughput metrics were captured via picture archiving and communication system from January 1, 2018, to December 16, 2019, and included 17,709 CT trauma scans from our institution. Initial data showed that imaging technologist variation played a significant role in trauma imaging turnaround time. In December 2019, we implemented a 2-pronged intervention: (1) educational intervention to techs and (2) modified trauma CT abdomen/pelvis to autogenerate and autosend reformats to picture archiving and communication system. A total of 13,169 trauma CT scans were evaluated from the postintervention period taking place from January 2020 to March 2021. Throughput metrics such as last image to first report interval and emergency department length of stay were captured and compared with performing technologist, time of day, and weekday versus weekend scans. RESULTS: Substantial variability among trauma CT scans was observed. For CT trauma abdomen/pelvis, the interval from last image to initial report decreased from 26.4 to 24.0 minutes ( P = 0.001) while the interval between first and last image time decreased from 11.4 to 4.2 minutes ( P < 0.001). Emergency department length of stay also decreased from 3.9 to 3.7 hours ( P < 0.0001) in the postintervention period. Variation among imaging technologist was statistically significant and became less significant after intervention ( P = 0.09, P = 0.54). CONCLUSIONS: Factors such as imaging technologist variability, time of day, and day of the week of trauma scans played a significant role in CT trauma turnaround time variability. Automation interventions can help with efficiency in image turnaround time.


Asunto(s)
Sistemas de Información Radiológica , Tomografía Computarizada por Rayos X , Humanos , Flujo de Trabajo , Tomografía Computarizada por Rayos X/métodos , Servicio de Urgencia en Hospital , Cintigrafía , Estudios Retrospectivos
16.
Abdom Radiol (NY) ; 48(6): 2091-2101, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36947205

RESUMEN

OBJECTIVE: To evaluate the prevalence of angular interface and the "drooping" sign in exophytic renal angiomyolipomas (AMLs) and the diagnostic performance in differentiating exophytic lipid-poor AMLs from other solid renal masses. METHODS: This IRB-approved, two-center study included 185 patients with 188 exophytic solid renal masses < 4 cm with histopathology and pre-operative CT within 30 days of surgical resection or biopsy. Images were reviewed for the presence of angular interface and the "drooping" sign qualitatively by three readers blinded to the final diagnosis, with majority rules applied. Both features were assessed quantitatively by cohort creators (who are not readers) independently. Free-marginal kappa was used to assess inter-reader agreement and agreement between two methods assessing each feature. Fisher's exact test, Mann-Whitney test, and multivariable logistic regression with two-tailed p < 0.05 were used to determine statistical significance. Diagnostic performance was assessed. RESULTS: Ninety-four patients had 96 AMLs, and 91 patients had 92 non-AMLs. Seventy-four (77%) of AMLs were lipid-poor based on quantitative assessment on CT. The presence of angular interface and the "drooping" sign by both qualitative and quantitative assessment were statistically significantly associated with AMLs (39% (qualitative) and 45% (quantitative) vs 15% (qualitative) and 13% (quantitative), and 48% (qualitative) and 43% (quantitative) vs 4% (qualitative) and 1% (quantitative), respectively, all p < 0.001) in univariable analysis. In multivariable analysis, only the "drooping" sign in either qualitative or quantitative assessment was a statistically significant predictor of AMLs (both p < 0.001). Inter-reader agreement for the "drooping" sign was moderate (k = 0.55) and for angular interface was fair (k = 0.33). Agreement between the two methods of assessing the "drooping" sign was substantial (k = 0.84) and of assessing the angular interface was moderate (k = 0.59). The "drooping" sign both qualitatively and quantitatively, alone or in combination of angular interface, had very high specificity (96-100%) and positive predictive value (PPV) (89-100%), moderate negative predictive value (62-68%), but limited sensitivity (23-49%) for lipid-poor AMLs. CONCLUSION: The "drooping" sign by both qualitative and quantitative assessment is highly specific for lipid-rich and lipid-poor AMLs. This feature alone or in combination with angular interface can aid in CT diagnosis of lipid-poor AMLs with very high specificity and PPV.


Asunto(s)
Angiomiolipoma , Carcinoma de Células Renales , Neoplasias Renales , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Angiomiolipoma/diagnóstico por imagen , Angiomiolipoma/patología , Carcinoma de Células Renales/patología , Sensibilidad y Especificidad , Diagnóstico Diferencial , Tomografía Computarizada por Rayos X/métodos , Lípidos , Estudios Retrospectivos
18.
J Comput Assist Tomogr ; 47(2): 315-321, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36728742

RESUMEN

OBJECTIVES: To provide the radiology community with data to address the question: "Compared with peer institutions, is my institution efficiently using its electrocardiographic (ECG) gating and cerebral perfusion-capable computed tomography (CT) scanners?" METHODS: In this retrospective study, we analyze 6 months of scanner utilization data from 62 institutions (299 locations, 507 scanners) to identify scanners capable of performing ECG gating and perfusion CT studies. We report the number of ECG gating/perfusion-capable scanners and locations as a function of the total number of locations and scanners in each institution. We additionally regress the number of ECG-gated and perfusion examinations on (1) the number of locations/scanners capable of performing these examinations and (2) the fraction of the institution's CT examination volume that requires ECG gating or perfusion. We provide look-up tables so an institution can compare its ECG-gated/perfusion examination volume to other institutions with similar ECG-gated/perfusion examination fractions and capable scanners. RESULTS: We detected an effect of both ECG-gating examination fraction and the number of ECG gating-capable scanners on ECG-gated examination volume ( χ21 = 77.5 [ P < 0.001] and χ21 = 64.2 [ P < 0.001], respectively). Similar results were obtained for perfusion examination fraction and perfusion-capable scanners as they relate to perfusion examination volume ( χ21 = 51.6 [ P < 0.001] and χ21 = 45.2 [ P < 0.001], respectively). The number of ECG gating/perfusion-capable scanners and locations within an institution were found to positively correlate with both the total number of locations and scanners within an institution ( P < 0.001 for all hypothesis tests). CONCLUSIONS: The study provides multi-institutional data on ECG gating and perfusion examination volumes that can be used to inform CT purchasing decisions.


Asunto(s)
Electrocardiografía , Tomografía Computarizada por Rayos X , Humanos , Estados Unidos , Estudios Retrospectivos , Prevalencia , Tomografía Computarizada por Rayos X/métodos , Electrocardiografía/métodos , Circulación Cerebrovascular
19.
Abdom Radiol (NY) ; 48(3): 1154-1163, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36692546

RESUMEN

PURPOSE: To evaluate diagnostic yield, safety profile, and specific technical considerations of transvaginal ultrasound (TVUS) guided biopsy/aspiration. MATERIALS/METHODS: TVUS guided biopsy (core, FNA) procedures with pre-procedure CT/MRI imaging at a single institution between 2001 and 2021 were reviewed. Relevant patient demographic data was extracted via the Electronic Health Record (EMR), technical details of the biopsy procedure were collected, and distance to target via transvaginal and transabdominal biopsy approach was measured on pre-procedure imaging. Surgical pathology was reviewed and assessed for concordance. Complications were assessed. Statistical analysis was performed using SPSS. RESULTS: 96 TVUS procedures (mean age, 58.7 ± 15.2 years; mean BMI, 27.4) were reviewed. TVUS guided approach decreased the distance to target (mean, 1.1 cm vs 8.6 cm transabdominal; p < 0.0001) and created a safe path not otherwise available in two patients. Average lesion size was 4.0 ± 2.1 cm (IQR 2.5, 5.2 cm) and targets at or above the vaginal cuff (0.9 ± 1.5 cm) and up to 0.5 ± 1.0 cm above the acetabular roof were accessible. 75 (78%) cases were core biopsies (18G; median, 2 passes) and 21 were FNA. Conscious sedation was used in 84.4% (n = 81) of cases and local anesthetic was also used in 84.4% (n = 81) of cases. Overall diagnostic yield was 98.9% (n = 94) with 94.7% (n = 89) cases confirmed as concordant diagnoses, including 57.4% (n = 54) malignant. Complications occurred in eight patients (8.3%), all minor. No post-biopsy infections were encountered regardless of administration of pre-procedure antibiotics (n = 14, 14.6%,), documentation of sterile prep (n = 92, 95.8%), or speculum use (n = 19, 19.8%). 50% (n = 48) had a prior hysterectomy, with no association with adequacy or complications (p = 0.9). CONCLUSION: Transvaginal biopsy of pelvic lesions offers excellent diagnostic yield and favorable safety profile, and can dramatically decrease distance to target. CLINICAL RELEVANCE: Ultrasound-guided transvaginal approach offers a safe and effective way to biopsy pelvic lesions in women.


Asunto(s)
Biopsia Guiada por Imagen , Imagen por Resonancia Magnética , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Biopsia Guiada por Imagen/métodos , Ultrasonografía , Biopsia con Aguja Fina , Estudios Retrospectivos , Ultrasonografía Intervencional/métodos
20.
AJR Am J Roentgenol ; 220(3): 371-380, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36000663

RESUMEN

BACKGROUND. CT examinations contain opportunistic body composition data with potential prognostic utility. Previous studies have primarily used manual or semiautomated tools to evaluate body composition in patients with colorectal cancer (CRC). OBJECTIVE. The purpose of this article is to assess the utility of fully automated body composition measures derived from pretreatment CT examinations in predicting survival in patients with CRC. METHODS. This retrospective study included 1766 patients (mean age, 63.7 ± 14.4 [SD] years; 862 men, 904 women) diagnosed with CRC between January 2001 and September 2020 who underwent pretreatment abdominal CT. A panel of fully automated artificial intelligence-based algorithms was applied to portal venous phase images to quantify skeletal muscle attenuation at the L3 lumbar level, visceral adipose tissue (VAT) area and subcutaneous adipose tissue (SAT) area at L3, and abdominal aorta Agatston score (aortic calcium). The electronic health record was reviewed to identify patients who died of any cause (n = 848). ROC analyses and logistic regression analyses were used to identify predictors of survival, with attention to highest- and lowest-risk quartiles. RESULTS. Patients who died, compared with patients who survived, had lower median muscle attenuation (19.2 vs 26.2 HU, p < .001), SAT area (168.4 cm2 vs 197.6 cm2, p < .001), and aortic calcium (620 vs 182, p < .001). Measures with highest 5-year AUCs for predicting survival in patients without (n = 1303) and with (n = 463) metastatic disease were muscle attenuation (0.666 and 0.701, respectively) and aortic calcium (0.677 and 0.689, respectively). A combination of muscle attenuation, SAT area, and aortic calcium yielded 5-year AUCs of 0.758 and 0.732 in patients without and with metastases, respectively. Risk of death was increased (p < .05) in patients in the lowest quartile for muscle attenuation (hazard ratio [HR] = 1.55) and SAT area (HR = 1.81) and in the highest quartile for aortic calcium (HR = 1.37) and decreased (p < .05) in patients in the highest quartile for VAT area (HR = 0.79) and SAT area (HR = 0.76). In 423 patients with available BMI, BMI did not significantly predict death (p = .75). CONCLUSION. Fully automated CT-based body composition measures including muscle attenuation, SAT area, and aortic calcium predict survival in patients with CRC. CLINICAL IMPACT. Routine pretreatment body composition evaluation could improve initial risk stratification of patients with CRC.


Asunto(s)
Inteligencia Artificial , Neoplasias Colorrectales , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Calcio , Tomografía Computarizada por Rayos X/métodos , Composición Corporal , Neoplasias Colorrectales/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...