Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sleep Med ; 54: 78-85, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30529781

RESUMEN

OBJECTIVES: The main objective of this meta-analysis was to assess the accuracy of the Sleep-Related Breathing Disorder (SRBD) Scale in the diagnosis of obstructive sleep apnea syndrome (OSAS) in children. PATIENTS/METHODS: A literature search of studies comparing SRBD to polysomnography for the diagnosis of OSAS in children was performed. Risks of biases were quantified using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Analyses determined the summary receiver operator characteristic area under the curve (SROC), the pooled sensitivity (Se), the specificity (Sp), and the positive and negative likelihood ratios (LR+ and LR-). Results were graded and are expressed as means [95% confidence interval]. Post-test probabilities were computed for various populations. RESULTS: Eleven studies were included; and two were considered to have high risk of bias. The SROC was 0.73 [CI: 0.63; 0.82]. The combined Se, Sp, LR+ and LR- were: 0.72 [CI: 0.68; 0.77], 0.59 [CI: 0.56; 0.63], 1.74 [CI: 1.32; 2.30], 0.53 [CI: 0.39; 0.71], respectively. Sub-group analyses displayed similar results in comparison to overall results. GRADE evidence for the overall analysis was low to moderate. Finally, pre-test to post-test probabilities were estimated to be: 3.5%-1%, 50%-30% and 75%-30%, for the general population, the obese patients and the patients assigned for surgical treatment of OSAS, respectively. CONCLUSIONS: The current meta-analysis indicates that the SRBD scale has acceptable accuracy in detecting patients with OSAS. It may be useful when evaluating patients with suspected OSAS before surgery. STUDY REGISTRATION: PROSPERO database (CRD42018088216).


Asunto(s)
Polisomnografía , Apnea Obstructiva del Sueño/diagnóstico , Niño , Humanos , Sensibilidad y Especificidad , Encuestas y Cuestionarios
2.
Paediatr Anaesth ; 24(10): 1088-98, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25074619

RESUMEN

BACKGROUND: Rate of perioperative respiratory complications between tracheal intubation (TI) and laryngeal mask airway remains unclear during pediatric anesthesia. OBJECTIVES: The aim of the present meta-analysis was to compare the perioperative respiratory complications between laryngeal mask airway and TI. METHODS: A meta-analysis of available controlled studies comparing laryngeal mask airway to TI was conducted. Studies including patients with airway infection were excluded. Data from each trial were combined to calculate the pooled odds ratios (OR) or mean difference (MD) and 95% confidence intervals. RESULTS: The meta-analysis was performed on 19 studies. In 12 studies, patients were given muscle relaxation, and in 16 studies, ventilation was controlled. During recovery from anesthesia, the incidence of desaturation (OR = 0.34 [0.19-0.62]), laryngospasm (OR = 0.34 [0.2-0.6]), cough (OR = 0.18 [0.11-0.27]), and breath holding (0.19 [0.05-0.68]) was lower when laryngeal mask airway was used to secure the airway. Postoperative incidences of sore throat (OR = 0.87 [0.53-1.44]), bronchospasm (OR = 0.56 [0.25-1.25]), aspiration (1.33 [0.46-3.91]) and blood staining on the device (OR = 0.62 [0.21-1.82]) did not differ between laryngeal mask airway and TI. Results were homogenous across the studies, with the exceptions of blood staining on the device. CONCLUSIONS: This meta-analysis found that the use of laryngeal mask airway in pediatric anesthesia results in a decrease in a number of common postanesthetic complications. It is therefore a valuable device for the management of the pediatric airway.


Asunto(s)
Manejo de la Vía Aérea/métodos , Intubación Intratraqueal/métodos , Máscaras Laríngeas/efectos adversos , Trastornos Respiratorios/etiología , Adolescente , Manejo de la Vía Aérea/efectos adversos , Manejo de la Vía Aérea/instrumentación , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Complicaciones Intraoperatorias/epidemiología , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Complicaciones Posoperatorias/epidemiología , Trastornos Respiratorios/terapia
3.
Pain ; 135(3): 291-299, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18258367

RESUMEN

We investigated the role of the glutamatergic and endogenous opioidergic systems in the paradoxical pain evoked by the simultaneous application of innocuous warm and cold stimuli to the skin with a "thermal grill". Two parallel randomized, double-blind, cross-over studies, including two groups of 12 healthy volunteers, were carried out to compare the effects of i.v. ketamine or naloxone to those of placebo, on the sensations produced by a thermode (i.e. thermal grill) composed of six bars applied on the palmar surface of the right hand. The temperature of alternate (even- and odd-numbered) bars could be controlled independently by Peltier elements to produce various patterns of the grill. During each experimental session we measured the effects of ketamine, naloxone or placebo on the intensity of: (i) paradoxical pain; (ii) "normal" thermal (heat and cold) pain; and (iii) non-painful thermal (warm and cool) sensations. Ketamine administration resulted in a significant reduction of paradoxical pain intensity but did not alter normal pain or non-painful thermal sensations. By contrast, naloxone had no effect on paradoxical pain, normal pain or non-painful thermal sensations. This study demonstrates for the first time that the "thermal grill illusion of pain" can be modulated pharmacologically. This paradoxical pain, which involves the glutamatergic systems, acting through the NMDA receptors, but not the tonic endogenous opioids systems, might share some mechanisms with pathological pain.


Asunto(s)
Ácido Glutámico/metabolismo , Hiperalgesia/fisiopatología , Ilusiones/fisiología , Péptidos Opioides/metabolismo , Dimensión del Dolor/métodos , Sensación Térmica/fisiología , Analgésicos/farmacología , Frío/efectos adversos , Estudios Cruzados , Método Doble Ciego , Antagonistas de Aminoácidos Excitadores/farmacología , Calor/efectos adversos , Humanos , Hiperalgesia/tratamiento farmacológico , Hiperalgesia/psicología , Ilusiones/efectos de los fármacos , Ketamina/farmacología , Naloxona/farmacología , Antagonistas de Narcóticos/farmacología , Nociceptores/efectos de los fármacos , Nociceptores/metabolismo , Dimensión del Dolor/efectos de los fármacos , Umbral del Dolor/efectos de los fármacos , Umbral del Dolor/fisiología , Dolor Intratable/metabolismo , Dolor Intratable/fisiopatología , Placebos , Receptores de Glutamato/efectos de los fármacos , Receptores de Glutamato/metabolismo , Receptores Opioides/efectos de los fármacos , Receptores Opioides/metabolismo , Sensación Térmica/efectos de los fármacos
4.
Anesthesiology ; 106(6): 1112-9, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17525585

RESUMEN

BACKGROUND: Malposition of percutaneously inserted chest tubes is considered as a rare complication in critically ill patients. Its incidence, however, remains uncertain. The aims of the study were to assess the true incidence of chest tube malposition in critically ill patients and to identify predicting factors. METHODS: The authors prospectively studied 122 chest tubes percutaneously inserted in 75 consecutive critically ill patients. For clinical reasons independent of the study, thoracic computed tomography scanning was performed in 63 patients, allowing direct visualization of 106 chest tubes. Based on these findings, chest tube position was classified as intrapleural, intrafissural, or intraparenchymal. Factors predicting chest tube malposition were analyzed by univariate and multivariate analysis. RESULTS: The mean delay between chest tube placement and thoracic scan was 3.5+/-2.9 days. Twenty-two chest tubes were diagnosed as being intrafissural (21%), and 10 were diagnosed as being intraparenchymal (9%). The only predicting factor associated with the risk of malposition was the use of a trocar for the percutaneous insertion of the chest tube (P=0.032). CONCLUSIONS: Malposition was detected in 30% of percutaneously inserted chest tubes, a higher incidence than previously reported. Avoiding the use of a trocar may reduce significantly the incidence of chest tube malposition.


Asunto(s)
Tubos Torácicos/efectos adversos , Enfermedad Crítica , Errores Médicos/estadística & datos numéricos , Tomografía Computarizada por Rayos X , Enfermedad Crítica/mortalidad , Enfermedad Crítica/terapia , Femenino , Humanos , Incidencia , Masculino , Errores Médicos/clasificación , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...