1.
Biosens Bioelectron ; 248: 115961, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38150800

RESUMEN

Whole-cell biosensors could be helpful for in situ disease diagnosis. However, their use in analyzing biological samples has been hindered by unstable responses, low signal enhancement, and growth inhibition in complex media. Here, we offered a solution by building a visual whole-cell biosensor for urinary mercury determination. With deoxyviolacein as the preferred signal for the mercury biosensor for the first time, it enabled the quantitative detection of urinary mercury with a favorable linear range from 1.57 to 100 nM. The biosensor can accurately diagnose urine mercury levels exceeding the biological exposure index with 95.8% accuracy. Thus, our study provided a biosensing platform with great potential to serve as a stable, user-friendly, and high-throughput alternative for the daily monitoring or estimating of urinary mercury.


Asunto(s)
Técnicas Biosensibles , Mercurio , Humanos , Ensayos Analíticos de Alto Rendimiento