Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Acta Pharm ; 65(3): 311-20, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26431108

RESUMEN

In an attempt to provide a reliable status of metal ions in children, new methods of analysis of children's sera are proposed. New flame atomic-absorption spectrometric (FAAS) methods are simple, cost- and time-effective and, above all, labor-, reagent- and sample-saving. Two methods were suggested: method A for simultaneous determination of Cu and Zn from 5-fold diluted sera, and method B, for assaying zinc alone in 10-fold diluted samples. Both methods are based on a single-step sample pretreatment (deproteinization with 3 mol dm-3 HCl). Method A uses a single-step calibration with a mixed standard. The main advantage of method B is an additional reduction in sample consumption. Both methods were fully validated against reference methods. Accuracy, sensitivity and precision have proven them to be comparable to the reference methods in terms of analytical performance, and applicable to analyses of children's sera.


Asunto(s)
Cobre/sangre , Suero/química , Tuberculosis/diagnóstico , Zinc/sangre , Niño , Humanos , Pronóstico , Espectrofotometría Atómica/métodos , Tuberculosis/sangre
2.
Acta Pharm ; 65(3): 321-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26431109

RESUMEN

Newly introduced methods of assaying simultaneously copper and zinc and zinc alone in serum by flame atomic-absorption spectrometry are simple and economical, especially in saving the consumption of serum material. Along with biochemical parameters, they have been successfully applied to diagnostics/prognostics of tuberculosis in children, through analyses of sera from pediatric patients with lung tuberculosis or suspected tuberculosis, enabling the follow-up of therapeutic efficiency. The prognostic strength of Cu and Cu/Zn ratio together with C-reactive protein, complement components C3 and C4, and erythrocyte sedimentation rate have been documented.


Asunto(s)
Cobre/sangre , Suero/química , Tuberculosis/diagnóstico , Zinc/sangre , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Pronóstico , Espectrofotometría Atómica/métodos , Tuberculosis/sangre
3.
Food Chem ; 140(1-2): 390-7, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23578658

RESUMEN

This report is aimed at intra-laboratory and inter-laboratory comparison of the results obtained during spectrophotometric and HPLC analyses of lycopene, ß-carotene and total carotenoids in tomato products and yellow maize flours/grits. Extensive statistical analyses are performed in order to identify the main sources of uncertainties which may occur when using: (i) different techniques/methods/approaches in the same/different laboratories, in various food samples, and (ii) to indicate the facts/conditions under which the biases between results may remain unidentified after applying statistical testing. Our data points to the inertness of t-test to detect significance of differences, particularly at low R values: in general, the higher correlation coefficient, the higher is sensitivity of statistical testing, especially of the paired t-test. Therefore, simple deviation of relationship line slope from unity could be used as additional evaluation parameter. This adds to reliable and objective quality assurance of foods in regard to carotenoids.


Asunto(s)
Carotenoides/análisis , Cromatografía Líquida de Alta Presión/métodos , Harina/análisis , Solanum lycopersicum/química , Espectrofotometría/métodos , Zea mays/química
4.
Talanta ; 84(2): 341-6, 2011 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-21376955

RESUMEN

The analytical performance of the newly proposed laser-based photoacoustic spectroscopy (PAS) and of optothermal window (OW) method for quantification of total anthocyanin concentration (TAC) in five sour cherry varieties is compared to that of the spectrophotometry (SP). High performance liquid chromatography (HPLC) was used to identify and quantify specific anthocyanins. Both, PAS and OW are direct methods that unlike SP and HPLC obviate the need for the extraction of analyte. The outcome of the study leads to the conclusion that PAS and OW are both suitable for quick screening of TAC in sour cherries. The correlation between the two methods and SP is linear with R(2)=0.9887 for PAS and R(2)=0.9918 for OW, respectively. Both methods are capable of the rapid determination of TAC in sour cherries without a need for a laborious sample pretreatment.


Asunto(s)
Antocianinas/análisis , Fotoquímica/métodos , Prunus/química , Temperatura , Acústica , Cromatografía Líquida de Alta Presión , Análisis Espectral/métodos
5.
Acta Pharm ; 61(1): 93-102, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21406347

RESUMEN

A new and simple flame atomic-absorption spectrometric (FAAS) method is proposed for simultaneous determination of iron and copper in children's sera. It is based on single-step sample pretreatment (deproteinization with 3 mol L-1 HCl, ratio 1:1) and single-step calibration using 1.5 mol L-1 HCl standard. During method's optimization a short multifactorial design experiment was used. The proposed method assures accuracy, sensitivity and precision comparable to that of the reference methods. The new approach is simple and time-, labour- and serum-saving, the latter being especially important in pediatric diagnostics.


Asunto(s)
Cobre/sangre , Hierro/sangre , Espectrofotometría Atómica/métodos , Niño , Humanos , Reproducibilidad de los Resultados , Factores de Tiempo
6.
Food Biophys ; 6(1): 12-19, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21423327

RESUMEN

This study describes the application of the laser photoacoustic spectroscopy (PAS) for quantification of total carotenoids (TC) in corn flours and sweetpotato flours. Overall, thirty-three different corn flours and nine sweetpotato flours were investigated. All PAS measurements were performed at room temperature using 488-nm argon laser radiation for excitation and mechanical modulation of 9 and 30 Hz. The measurements were repeated within a run and within several days or months. The UV-Vis spectrophotometry was used as the reference method. The concentration range that allows for the reliable analysis of TC spans a region from 1 to 40 mg kg(-1) for corn flours and from 9 to 40 mg kg(-1) for sweetpotato flours. In the case of sweetpotato flours, the quantification may extend even to 240 mg kg(-1) TC. The estimated detection limit values for TC in corn and sweetpotato flours were 0.1 and 0.3 mg kg(-1), respectively. The computed repeatability (n = 3-12) and intermediate precision (n = 6-28) RSD values at 9 and 30 Hz are comparable: 0.1-17.1% and 5.3-14.7% for corn flours as compared with 1.4-9.1% and 4.2-23.0% for sweetpotato flours. Our results show that PAS can be successfully used as a new analytical tool to simply and rapidly screen the flours for their nutritional potential based on the total carotenoid concentration.

7.
Food Biophys ; 5(1): 24-33, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20401182

RESUMEN

The trans-lycopene content of fresh tomato homogenates was assessed by means of the laser photoacoustic spectroscopy, the laser optothermal window, micro-Raman spectroscopy, and colorimetry; none of these methods require the extraction from the product matrix prior to the analysis. The wet chemistry method (high-performance liquid chromatography) was used as the absolute quantitative method. Analytical figures of merit for all methods were compared statistically; best linear correlation was achieved for the chromaticity index a* and chroma C*.

8.
Acta Chim Slov ; 57(4): 781-7, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24061878

RESUMEN

Total carotenoids (TC) were determined as a measure of total xanthophylls in grain flours and grits, by new validated spectrophotometric method based on A1cm1%-approach. The general analytical procedure is easily adjustable to different samples, the number of extraction steps depending on TC concentration in the sample. Basically, two methods have been suggested: the rapid one for low-TC samples (white corn, wheat, soybean, sorghum) including one to two extractions, and the one for high-TC samples (yellow corn) needing three to four extractions. Method's accuracy was proven against the reference standard material (102.1±3.9%) and the reference method. Good precision (repeatability and intermediate precision of upto 9% for yellow corn products) and sensitivity with LOD (limit of detection) and LLOQ (lower limit of quantitation) of 0.2 and 0.6 mg kg-1 TC, resp., were estimated. The method was applied to the control of nutritional value of cereal grain products. TC concentration (in mg kg-1) in the samples ranged from 11-23 in yellow corn flours, 0.7-0.9 in white corn flours, 17-22 in yellow corn grits, 1.1-1.3 in wheat flours, 1.6 in wheat grits and 1.5 in sorghum flour, to 0.9-9.9 in soybean flours.

9.
Anal Chim Acta ; 573-574: 466-73, 2006 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-17723562

RESUMEN

Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of time needed to complete the analysis. The resulting analytical procedure is characterized in details in terms of the figures of merit. The method is sensitive, precise and accurate; for both, standard additions and calibration in soybean oil, recovery ranges between 98 and 102%. For the most accurate analyses the approach of standard additions is preferred but for quick routine analyses this latter can be replaced by the calibration in soybean oil. Limit of detection value (LOD=3S.D.(B)/a, where S.D.(B) is the standard deviation of the blank, "a" is the slope of calibration line) as low as 12 microg TC/100 g was achieved in soybean oil enabling the sensitive detection. Concentration of TC in margarines declared as being coloured with beta-carotene (carotene) ranges between 0.3 and 0.9 mg/100 g while in carrot extract-coloured margarine TC is 0.2 mg/100 g.

10.
J Agric Food Chem ; 53(9): 3295-9, 2005 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-15853362

RESUMEN

This study reports on the first use of the "optothermistor" as a novel, precise, fast, and low-cost detector of lycopene in a wide range of commercially available processed-tomato products. The quantitative performance of the new device was evaluated by comparing data obtained to that acquired by conventional methods, namely, absorption spectrophotometry and high-performance liquid chromatography (HPLC); the linear correlation was high (R = 0.98). The variation of data obtained with the optothermistor in a series of consecutive measurements performed with the same loading of the sample was better than 1%. However, the repeatability (RSD 0.5-9.0%, n = 3-5) achieved with the optothermistor by independent analyses (multiple loading) is comparable to that of HPLC and spectrophotometry. Results of the studies performed on the 19 products derived from tomatoes demonstrated that the optothermistor is suitable for selective, accurate, precise, and simple determination of lycopene (range = 7-75 mg/100 g of product weight) without the need for a sample pretreatment step. The estimated sensitivity of the present optothermistor is 2 mg of lycopene/100 g of product.


Asunto(s)
Carotenoides/análisis , Análisis de los Alimentos/métodos , Manipulación de Alimentos/métodos , Calor , Solanum lycopersicum/química , Cromatografía Líquida de Alta Presión , Licopeno , Sensibilidad y Especificidad , Espectrofotometría
11.
Anal Chem ; 76(17): 5203-7, 2004 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-15373462

RESUMEN

The concept of the optothermal window (OW) is proposed as a reliable analytical tool to rapidly determine the concentration of lycopene in a large variety of commercial tomato products in an extremely simple way (the determination is achieved without the need for pretreatment of the sample). The OW is a relative technique as the information is deduced from the calibration curve that relates the OW data (i.e., the product of the absorption coefficient beta and the thermal diffusion length micro) with the lycopene concentration obtained from spectrophotometric measurements. The accuracy of the method has been ascertained with a high correlation coefficient (R = 0.98) between the OW data and results acquired from the same samples by means of the conventional extraction spectrophotometric method. The intrinsic precision of the OW method is quite high (better than 1%), whereas the repeatability of the determination (RSD = 0.4-9.5%, n= 3-10) is comparable to that of spectrophotometry.


Asunto(s)
Carotenoides/análisis , Análisis de los Alimentos/métodos , Solanum lycopersicum/química , Calibración , Rayos Láser , Licopeno , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA