RESUMEN
Objectives: To investigate the change in severity of mitral regurgitation (MR) after transcatheter aortic valve replacement (TAVR) and its effect on 5-year mortality. Background: There is inconsistency in literature on pre-existing MR influencing long-term survival in patients who undergo TAVR. Methods: Patients who underwent TAVR at the University Hospital Schleswig-Holstein (USKH) Campus Kiel between March 2009 and February 2018 have been enrolled. Echocardiography determined the degree of MR before and within 7 days after TAVR. Patients were divided into two groups according to their MR at baseline: MR-grade ≤ 2 (non-relevant MR, nr-MR) and baseline MR-grade > 2 (relevant MR, r-MR). Primary endpoint was a composite of MR baseline influence on mortality and MR reduction and its' impact on mortality. Results: A total of 820 patients (642 nr-MR and 178 in r-MR) were included in this study. Of these, 167 patients showed an improvement in MR-grade. Thereof 106 (63.5 %) referred to r-MR with a significant decrease in mean MR-grade (p < 0.01). Systolic pulmonary artery pressure (sPAP) (p < 0.01) and NT-proBNP (p = 0.03) decreased in patients who had an improvement. There was no significant difference in 5-year mortality for MR at baseline (p = 0.35) or reduction in mortality for r-MR patients with an MR improvement compared to patients with worsening or equal MR status (p = 0.80). Conclusion: In patients undergoing TAVR, 63.5 % of patients with MR-grade ≥ 2 at baseline showed an improvement of grade of MR after TAVR with reduction of their sPAP and NT-proBNP values but there was no significant difference in mortality.
RESUMEN
The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.
RESUMEN
BACKGROUND: Composite T-grafts between left internal mammary artery (LIMA) and radial artery (RA) are a common concept in complete arterial myocardial revascularization. The aim of the present study was to investigate whether the use of the great saphenous vein (SV) instead of RA leads to comparably good results in terms of outcome in this context. METHODS: Patients who underwent myocardial revascularization with a T-graft using RA or a segment of SV to the right coronary artery or circumflex artery between the beginning of 2014 and the end of 2019 at the Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel were included. To minimize surgical variation, only patients were observed by a single senior surgeon in the department. Exclusion criteria were previous cardiac surgery, preoperative extracorporeal circulatory support, off-pump surgery, additional aortocoronary bypasses, and cardiac combination procedures. RESULTS: A total of 115 patients were studied. In 55 patients, the T-graft was placed between the LIMA and SV, and in 60 patients, the T-graft was placed between the LIMA and RA. Patients in the SV group were older (70.6 ± 7.8 vs. 58.5 ± 10.0 years; p < 0.001), suffered more frequently from non-ST elevation myocardial infarction (12.7 vs. 1.7%; p = 0.027), arterial hypertension (83.6 vs. 61.7%; p = 0.009), and atrial fibrillation (18.2 vs. 1.7%; p = 0.003). They were less likely to be active smokers (16.4 vs. 38.3%; p = 0.009) and less likely to have a history of variceal surgery (0 vs. 15.0%; p = 0.003). Calcification of the ascending aorta was also found more frequently in the saphenous group (18.2 vs. 3.3%, p = 0.009). Operative times and number of distal anastomoses did not differ significantly between the two groups. Postoperative deliriums (16.7 vs. 5.0%; p = 0.043) were observed more frequently in venous patients. Wound healing disorders of the leg (11.1 vs. 0%; p = 0.011) did only occur in SV group and wound infections of the arm only in the RA group. Complete follow-up was achieved in 74.8% of cases. Median follow-up was 60.3 (39.6; 73.2) months. Serious adverse cardiac-cerebral events (19.0 vs. 22.7%; p = 0.675) and mortality (14.5 vs. 6.7%; p = 0.167) did not differ significantly between the groups at follow-up. Myocardial infarction (0 vs. 2.5%; p = 1.000) and stroke (0 vs. 7.5%; p = 0.245) were observed exclusively in RA group. Percutaneous coronary intervention was required in single patients of RA group (0 vs. 15.0%; p = 0.028). No patient from either group underwent repeat coronary artery bypass grafting (CABG). The patients of SV group had angiographically competent grafts and open anastomoses. Graft failure was noted in a single patient in RA group, in which case both grafts and native coronary vessels were stented. Kaplan-Meier analysis revealed no significant survival disadvantage for SV group compared with RA group. CONCLUSION: CABG with a composite T-graft between LIMA and a segment of SV may be comparable to bypass surgery with a composite T-graft between LIMA and RA. This might be true in terms of morbidity and mortality over an intermediate-term observation period. The results of our studies give rise to the hypothesis that the decision not to perform aortic bypass anastomosis may be more important than the choice of graft material.
RESUMEN
Bone sarcoma are infrequent diseases, representing < 0.2% of all adult neoplasms. A multidisciplinary management within reference centers for sarcoma, with discussion of the diagnostic and therapeutic strategies within an expert multidisciplinary tumour board, is essential for these patients, given its heterogeneity and low frequency. This approach leads to an improvement in patient's outcome, as demonstrated in several studies. The Sarcoma European Latin-American Network (SELNET), aims to improve clinical outcome in sarcoma care, with a special focus in Latin-American countries. These Clinical Practice Guidelines (CPG) have been developed and agreed by a multidisciplinary expert group (including medical and radiation oncologist, surgical oncologist, orthopaedic surgeons, radiologist, pathologist, molecular biologist and representatives of patients advocacy groups) of the SELNET consortium, and are conceived to provide the standard approach to diagnosis, treatment and follow-up of bone sarcoma patients in the Latin-American context.
Asunto(s)
Neoplasias Óseas , Osteosarcoma , Sarcoma , Neoplasias de los Tejidos Blandos , Adulto , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/patología , Neoplasias Óseas/terapia , Humanos , Osteosarcoma/diagnóstico , Osteosarcoma/patología , Osteosarcoma/terapia , Guías de Práctica Clínica como Asunto , Sarcoma/diagnóstico , Sarcoma/patología , Sarcoma/terapia , Neoplasias de los Tejidos Blandos/patologíaAsunto(s)
Tumores del Estroma Gastrointestinal/tratamiento farmacológico , Guías como Asunto , Neoplasias de los Tejidos Blandos/tratamiento farmacológico , Tumores del Estroma Gastrointestinal/epidemiología , Humanos , América Latina/epidemiología , Sarcoma , Neoplasias de los Tejidos Blandos/epidemiologíaRESUMEN
In 2017, JRC-Geel organised a proficiency test for 120 participants on the massic activity determination of 131I, 134Cs and 137Cs in maize powder. The proficiency test reference material was produced by spiking blank maize powder. The material was characterised for its radioactive content using γ-ray spectrometry. The z scores of the reported massic activity were acceptable in 92% of the results for 131I, and in 94% for both 134Cs and 137Cs. The ζ scores were consistent with the reference value for 66% of the results for 131I, 56% for 134Cs and 68% for 137Cs.
Asunto(s)
Radioisótopos de Cesio/química , Radioisótopos de Yodo/química , Zea mays/química , Polvos , Espectrometría gamma/métodos , IncertidumbreRESUMEN
The emission probabilities of γ rays produced in the 227Ac decay series were determined by high-resolution γ-ray spectrometry of sources with standardised activity. The sources were prepared quantitatively on glass discs by drop deposition of a solution with 227Ac in radioactive equilibrium with its daughter nuclides. Their activity was measured by a primary standardisation technique based on alpha-particle counting at a defined low solid angle. Four laboratories performed γ-ray spectrometry and derived absolute γ-ray intensities. Mean values were calculated and compared with literature data and the currently recommended evaluated data. New values on certain γ-ray emission probabilities are proposed.
RESUMEN
Accurate measurements were performed of the photon emission probabilities following the α decay of 235U to 231Th. Sources of highly enriched 235U were characterised in terms of isotopic composition by mass spectrometry and their activities were standardised by means of alpha-particle counting at a low defined solid angle. The standardised sources were subsequently measured by high-resolution γ-ray spectrometry with calibrated high-purity germanium detectors to determine the photon emission probabilities. Four laboratories participated in this work and reported emission probabilities for 33 γ-ray lines. Most of them agree with previously published evaluated data. In addition, new values are proposed for γ-lines which have been measured only once in the past.
RESUMEN
At the JRC-Geel's RadioNuclide Metrology sector, a Monte Carlo code based on EGSnrc, and a general purpose calculation sheet implemented in Microsoft Excel®, have been developed to make the quantitative gamma-ray spectrometry analysis of samples simpler and more robust. The further aim is that the software can be used by non-experts in gamma-ray spectrometry e.g. external researchers using JRC-Geel's facilities through the EUFRAT transnational access scheme. This paper presents the developed Monte Carlo software and the functionality included in the calculation sheet.
RESUMEN
The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of 208Tl and 214Bi in thin materials, initially developed to measure the radiopurity of the double ß decay source foils of the SuperNEMO experiment at the µBq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some µBq/kg.
RESUMEN
Reliable measurement of Naturally Occurring Radioactive Materials is of significance in order to comply with environmental regulations and for radiological protection purposes. This paper discusses the standardisation of three reference materials, namely sand, tuff and TiO2 to serve as quality control materials for traceability, method validation and instrument calibration. The sample preparation, material characterization via γ, α and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and the assignment of values for both the 4n (Thorium) and 4n+2 (Uranium) decay series are described.
RESUMEN
A measurement station dedicated for quantitative radiological characterisation of naturally occurring radionuclides in a metallurgical company and based on gamma-ray spectrometry was developed. The station is intended for performing quality control of final non-ferrous metal products and for radiological checks of incoming materials. A low-background point-contact HPGe-detector was used and the signal was split in two branches to enable collecting simultaneously spectra with high amplification (for gamma-ray energies below 250keV) and low amplification.
RESUMEN
We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-ß decay of ^{150}Nd using a total exposure of 0.19 kg yr recorded with the NEMO-3 detector at the Modane Underground Laboratory. We find no evidence of this decay and set lower limits on the half-life in the range T_{1/2}>(1.1-3.2)×10^{21} yr at the 90% C.L., depending on the model used for the kinematic distributions of the emitted electrons.
RESUMEN
Heart valves are constantly exposed to high dynamic loading and are prone to degeneration. Therefore, it is a challenge to develop a durable heart valve substitute. A promising approach in heart valve engineering is the development of hybrid scaffolds which are composed of a mechanically strong inorganic mesh enclosed by valvular tissue. In order to engineer an efficient, durable and very thin heart valve for transcatheter implantations, we developed a fabrication process for microstructured heart valve leaflets made from a nickel-titanium (NiTi) thin film shape memory alloy. To examine the capability of microstructured NiTi thin film as a matrix scaffold for tissue engineered hybrid heart valves, leaflets were successfully seeded with smooth muscle cells (SMCs). In vitro pulsatile hydrodynamic testing of the NiTi thin film valve leaflets demonstrated that the SMC layer significantly improved the diastolic sufficiency of the microstructured leaflets, without affecting the systolic efficiency. Compared to an established porcine reference valve model, magnetron sputtered NiTi thin film material demonstrated its suitability for hybrid tissue engineered heart valves.
Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Níquel/química , Diseño de Prótesis/métodos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Titanio/química , Animales , Fenómenos Biomecánicos , Arterias Carótidas/citología , Válvulas Cardíacas/fisiología , Válvulas Cardíacas/cirugía , Modelos Cardiovasculares , OvinosRESUMEN
Approximately 30 % of patients suffering from severe valvular heart disease, such as mitral valve regurgitation are non-compliant to the gold standard of minimally invasive surgery, reconstruction or valve replacement. The number of these mostly old patients with severe comorbidities is increasing; therefore, transcatheter interventions have been developed to address an unmet clinical need and may be an alternative therapeutic option to the reference standard. Apart from the successful MitraClip therapy, alternative transcatheter reconstruction technologies are being developed. As with transcatheter aortic valve implantation (TAVI) procedures, the off-pump implantation of a valved stent into the mitral position mainly via a transapical approach will be of great benefit. Recently, the feasibility of transcatheter mitral valved stent implantation in high-risk patients has already been reported.
Asunto(s)
Cateterismo Cardíaco/tendencias , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Prótesis Valvulares Cardíacas/tendencias , Anuloplastia de la Válvula Mitral/tendencias , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Cateterismo Cardíaco/instrumentación , Medicina Basada en la Evidencia , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Anuloplastia de la Válvula Mitral/instrumentación , Diseño de Prótesis/tendencias , Resultado del TratamientoRESUMEN
Following the accident at the Fukushima Daiichi nuclear power plant, a campaign of sampling and measuring anthropogenic radionuclides in North Pacific seawater was set up. The main aim was to study natural processes using these radionuclides as tracers. Because of dilution, the activities of anthropogenic radionuclides at long range were very low and their measurement required advanced pre-concentration techniques and underground gamma-ray spectrometry. Data and metrological aspects of the measurements using HPGe-detectors are presented and discussed.
Asunto(s)
Bioensayo/métodos , Accidente Nuclear de Fukushima , Plancton/química , Radioisótopos/análisis , Radiometría/métodos , Agua de Mar/química , Contaminantes Radiactivos del Agua/análisis , Monitoreo del Ambiente/métodos , Océano Pacífico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría gamma/métodosRESUMEN
The aim of this study was to check for equivalence of computer codes that are capable of performing calculations of true coincidence summing (TCS) correction factors. All calculations were performed for a set of well-defined detector parameters, sample parameters and decay scheme data. The studied geometry was a point source of (133)Ba positioned directly on the detector window of a low-energy (n-type) detector. Good agreement was established between the TCS correction factors computed by the different codes.
RESUMEN
Scaffolds for tissue engineering enable the possibility to fabricate and form biomedical implants in vitro, which fulfill special functionality in vivo. In this study, free-standing NickelTitanium(NiTi) thin film mesheswere produced by means of magnetron sputter deposition.Meshes contained precisely defined rhombic holes in the size of 440 to 1309 µm2 and a strut width ranging from 5.3 to 9.2 µm. The effective mechanical properties of the microstructured superelastic NiTi thin film were examined by tensile testing. These results will be adapted for the design of the holes in the film. The influence of hole and strut dimensions on the adhesion of sheep autologous cells (CD133+) was studied after 24 h and after seven days of incubation. Optical analysis using fluorescence microscopy and scanning electron microscopy showed that cell adhesion depends on the structural parameters of the mesh. After 7 days in cell culture a large part of the mesh was covered with aligned fibrous material. Cell adhesion is particularly facilitated on meshes with small rhombic holes of 440 µm2 and a strut width of 5.3 µm. Our results demonstrate that free-standing NiTi thin film meshes have a promising potential for applicationsin cardiovascular tissue engineering, particularly for the fabrication of heart valves.