Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Comput Biol Med ; 170: 108001, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38280254

RESUMEN

Intracranial arterial stenosis (ICAS) is characterized by the pathological narrowing or occlusion of the inner lumen of intracranial blood vessels. However, the retina can indirectly react to cerebrovascular disease. Therefore, retinal fundus images (RFI) serve as valuable noninvasive and easily accessible screening tools for early detection and diagnosis of ICAS. This paper introduces an adversarial learning-based domain adaptation algorithm (ALDA) specifically designed for ICAS detection in multi-source datasets. The primary objective is to achieve accurate detection and enhanced generalization of ICAS based on RFI. Given the limitations of traditional algorithms in meeting the accuracy and generalization requirements, ALDA overcomes these challenges by leveraging RFI datasets from multiple sources and employing the concept of adversarial learning to facilitate feature representation sharing and distinguishability learning. In order to evaluate the performance of the ALDA algorithm, we conducted experimental validation on multi-source datasets. We compared its results with those obtained from other deep learning algorithms in the ICAS detection task. Furthermore, we validated the potential of ALDA for detecting diabetic retinopathy. The experimental results clearly demonstrate the significant improvements achieved by the ALDA algorithm. By leveraging information from diverse datasets, ALDA learns feature representations that exhibit enhanced generalizability and robustness. This makes it a reliable auxiliary diagnostic tool for clinicians, thereby facilitating the prevention and treatment of cerebrovascular diseases.


Asunto(s)
Arterias , Retina , Humanos , Constricción Patológica , Fondo de Ojo , Algoritmos
2.
Artículo en Inglés | MEDLINE | ID: mdl-37831570

RESUMEN

The blood pressure (BP) waveform is a vital source of physiological and pathological information concerning the cardiovascular system. This study proposes a novel attention-guided conditional generative adversarial network (cGAN), named PPG2BP-cGAN, to estimate BP waveforms based on photoplethysmography (PPG) signals. The proposed model comprises a generator and a discriminator. Specifically, the UNet3+-based generator integrates a full-scale skip connection structure with a modified polarized self-attention module based on a spatial-temporal attention mechanism. Additionally, its discriminator comprises PatchGAN, which augments the discriminative power of the generated BP waveform by increasing the perceptual field through fully convolutional layers. We demonstrate the superior BP waveform prediction performance of our proposed method compared to state-of-the-art (SOTA) techniques on two independent datasets. Our approach first pre-trained on a dataset containing 683 subjects and then tested on a public dataset. Experimental results from the Multi-parameter Intelligent Monitoring in Intensive Care dataset show that the proposed method achieves a root mean square error of 3.54, mean absolute error of 2.86, and Pearson coefficient of 0.99 for BP waveform estimation. Furthermore, the estimation errors (mean error ± standard deviation error) for systolic BP and diastolic BP are 0.72 ± 4.34 mmHg and 0.41 ± 2.48 mmHg, respectively, meeting the American Association for the Advancement of Medical Instrumentation standard. Our approach exhibits significant superiority over SOTA techniques on independent datasets, thus highlighting its potential for future applications in continuous cuffless BP waveform measurement.

3.
Bioengineering (Basel) ; 10(8)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37627856

RESUMEN

One of the early manifestations of systemic atherosclerosis, which leads to blood circulation issues, is the enhanced arterial light reflex (EALR). Fundus images are commonly used for regular screening purposes to intervene and assess the severity of systemic atherosclerosis in a timely manner. However, there is a lack of automated methods that can meet the demands of large-scale population screening. Therefore, this study introduces a novel cross-scale transformer-based multi-instance learning method, named MIL-CT, for the detection of early arterial lesions (e.g., EALR) in fundus images. MIL-CT utilizes the cross-scale vision transformer to extract retinal features in a multi-granularity perceptual domain. It incorporates a multi-head cross-scale attention fusion module to enhance global perceptual capability and feature representation. By integrating information from different scales and minimizing information loss, the method significantly improves the performance of the EALR detection task. Furthermore, a multi-instance learning module is implemented to enable the model to better comprehend local details and features in fundus images, facilitating the classification of patch tokens related to retinal lesions. To effectively learn the features associated with retinal lesions, we utilize weights pre-trained on a large fundus image Kaggle dataset. Our validation and comparison experiments conducted on our collected EALR dataset demonstrate the effectiveness of the MIL-CT method in reducing generalization errors while maintaining efficient attention to retinal vascular details. Moreover, the method surpasses existing models in EALR detection, achieving an accuracy, precision, sensitivity, specificity, and F1 score of 97.62%, 97.63%, 97.05%, 96.48%, and 97.62%, respectively. These results exhibit the significant enhancement in diagnostic accuracy of fundus images brought about by the MIL-CT method. Thus, it holds potential for various applications, particularly in the early screening of cardiovascular diseases such as hypertension and atherosclerosis.

4.
Bioengineering (Basel) ; 10(8)2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37627863

RESUMEN

Retinopathy, a prevalent disease causing visual impairment and sometimes blindness, affects many individuals in the population. Early detection and treatment of the disease can be facilitated by monitoring the retina using fundus imaging. Nonetheless, the limited availability of fundus images and the imbalanced datasets warrant the development of more precise and efficient algorithms to enhance diagnostic performance. This study presents a novel online knowledge distillation framework, called CLRD, which employs a collaborative learning approach for detecting retinopathy. By combining student models with varying scales and architectures, the CLRD framework extracts crucial pathological information from fundus images. The transfer of knowledge is accomplished by developing distortion information particular to fundus images, thereby enhancing model invariance. Our selection of student models includes the Transformer-based BEiT and the CNN-based ConvNeXt, which achieve accuracies of 98.77% and 96.88%, respectively. Furthermore, the proposed method has 5.69-23.13%, 5.37-23.73%, 5.74-23.17%, 11.24-45.21%, and 5.87-24.96% higher accuracy, precision, recall, specificity, and F1 score, respectively, compared to the advanced visual model. The results of our study indicate that the CLRD framework can effectively minimize generalization errors without compromising independent predictions made by student models, offering novel directions for further investigations into detecting retinopathy.

5.
Artículo en Inglés | MEDLINE | ID: mdl-37368801

RESUMEN

Radiomics refers to the high-throughput extraction of quantitative features from medical images, and is widely used to construct machine learning models for the prediction of clinical outcomes, while feature engineering is the most important work in radiomics. However, current feature engineering methods fail to fully and effectively utilize the heterogeneity of features when dealing with different kinds of radiomics features. In this work, latent representation learning is first presented as a novel feature engineering approach to reconstruct a set of latent space features from original shape, intensity and texture features. This proposed method projects features into a subspace called latent space, in which the latent space features are obtained by minimizing a unique hybrid loss function including a clustering-like loss and a reconstruction loss. The former one ensures the separability among each class while the latter one narrows the gap between the original features and latent space features. Experiments were performed on a multi-center non-small cell lung cancer (NSCLC) subtype classification dataset from 8 international open databases. Results showed that compared with four traditional feature engineering methods (baseline, PCA, Lasso and L2,1-norm minimization), latent representation learning could significantly improve the classification performance of various machine learning classifiers on the independent test set (all p<0.001). Further on two additional test sets, latent representation learning also showed a significant improvement in generalization performance. Our research shows that latent representation learning is a more effective feature engineering method, which has the potential to be used as a general technology in a wide range of radiomics researches.

6.
Artículo en Inglés | MEDLINE | ID: mdl-37018254

RESUMEN

Pancreatic cancer is one of the most malignant cancers with high mortality. The rapid on-site evaluation (ROSE) technique can significantly accelerate the diagnostic workflow of pancreatic cancer by immediately analyzing the fast-stained cytopathological images with on-site pathologists. However, the broader expansion of ROSE diagnosis has been hindered by the shortage of experienced pathologists. Deep learning has great potential for the automatic classification of ROSE images in diagnosis. But it is challenging to model the complicated local and global image features. The traditional convolutional neural network (CNN) structure can effectively extract spatial features, while it tends to ignore global features when the prominent local features are misleading. In contrast, the Transformer structure has excellent advantages in capturing global features and long-range relations, while it has limited ability in utilizing local features. We propose a multi-stage hybrid Transformer (MSHT) to combine the strengths of both, where a CNN backbone robustly extracts multi-stage local features at different scales as the attention guidance, and a Transformer encodes them for sophisticated global modeling. Going beyond the strength of each single method, the MSHT can simultaneously enhance the Transformer global modeling ability with the local guidance from CNN features. To evaluate the method in this unexplored field, a dataset of 4240 ROSE images is collected where MSHT achieves 95.68% in classification accuracy with more accurate attention regions. The distinctively superior results compared to the state-of-the-art models make MSHT extremely promising for cytopathological image analysis. The codes and records are available at: https://github.com/sagizty/ Multi-Stage-Hybrid-Transformer.

7.
Phys Med Biol ; 68(4)2023 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-36696695

RESUMEN

Objective.Fluorescence molecular tomography (FMT) is a promising molecular imaging modality for quantifying the three-dimensional (3D) distribution of tumor probes in small animals. However, traditional deep learning reconstruction methods that aim to minimize the mean squared error (MSE) and iterative regularization algorithms that rely on optimal parameters are typically influenced by strong noise, resulting in poor FMT reconstruction robustness.Approach.In this letter, we propose an adaptive adversarial learning strategy (3D-UR-WGAN) to achieve robust FMT reconstructions. Unlike the pixel-based MSE criterion in traditional CNNs or the regularization strategy in iterative solving schemes, the reconstruction strategy can greatly facilitate the performance of the network models through alternating loop training of the generator and the discriminator. Second, the reconstruction strategy combines the adversarial loss in GANs with the L1 loss to significantly enhance the robustness and preserve image details and textual information.Main results.Both numerical simulations and physical phantom experiments demonstrate that the 3D-UR-WGAN method can adaptively eliminate the effects of different noise levels on the reconstruction results, resulting in robust reconstructed images with reduced artifacts and enhanced image contrast. Compared with the state-of-the-art methods, the proposed method achieves better reconstruction performance in terms of target shape recovery and localization accuracy.Significance.This adaptive adversarial learning reconstruction strategy can provide a possible paradigm for robust reconstruction in complex environments, and also has great potential to provide an alternative solution for solving the problem of poor robustness encountered in other optical imaging modalities such as diffuse optical tomography, bioluminescence imaging, and Cherenkov luminescence imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Óptica , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Fantasmas de Imagen , Artefactos
8.
Comput Methods Programs Biomed ; 229: 107293, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36481532

RESUMEN

BACKGROUND AND OBJECTIVE: Fluorescence molecular tomography (FMT) is a promising molecular imaging modality for quantifying the three-dimensional (3D) distribution of fluorescent probes in small animals. Over the past few years, learning-based FMT reconstruction methods have achieved promising results. However, these methods typically attempt to minimize the mean-squared error (MSE) between the reconstructed image and the ground truth. Although signal-to-noise ratios (SNRs) are improved, they are susceptible to non-uniform artifacts and loss of structural detail, making it extremely challenging to obtain accurate and robust FMT reconstructions under noisy measurements. METHODS: We propose a novel dual-domain joint strategy based on the image domain and perception domain for accurate and robust FMT reconstruction. First, we formulate an explicit adversarial learning strategy in the image domain, which greatly facilitates training and optimization through two enhanced networks to improve anti-noise ability. Besides, we introduce a novel transfer learning strategy in the perceptual domain to optimize edge details by providing perceptual priors for fluorescent targets. Collectively, the proposed dual-domain joint reconstruction strategy can significantly eliminate the non-uniform artifacts and effectively preserve the structural edge details. RESULTS: Both numerical simulations and in vivo mouse experiments demonstrate that the proposed method markedly outperforms traditional and cutting-edge methods in terms of positioning accuracy, image contrast, robustness, and target morphological recovery. CONCLUSIONS: The proposed method achieves the best reconstruction performance and has great potential to facilitate precise localization and 3D visualization of tumors in in vivo animal experiments.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Animales , Ratones , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía , Artroplastia , Percepción , Fantasmas de Imagen
9.
IEEE J Biomed Health Inform ; 27(5): 2219-2230, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35700247

RESUMEN

Ambulatory blood pressure (BP) monitoring plays a critical role in the early prevention and diagnosis of cardiovascular diseases. However, cuff-based inflatable devices cannot be used for continuous BP monitoring, while pulse transit time or multi-parameter-based methods require more bioelectrodes to acquire electrocardiogram signals. Thus, estimating the BP waveforms only based on photoplethysmography (PPG) signals for continuous BP monitoring has essential clinical values. Nevertheless, extracting useful features from raw PPG signals for fine-grained BP waveform estimation is challenging due to the physiological variation and noise interference. For single PPG analysis utilizing deep learning methods, the previous works depend mainly on stacked convolution operation, which ignores the underlying complementary time-dependent information. Thus, this work presents a novel Transformer-based method with knowledge distillation (KD-Informer) for BP waveform estimation. Meanwhile, we integrate the prior information of PPG patterns, selected by a novel backward elimination algorithm, into the knowledge transfer branch of the KD-Informer. With these strategies, the model can effectively capture the discriminative features through a lightweight architecture during the learning process. Then, we further adopt an effective transfer learning technique to demonstrate the excellent generalization capability of the proposed model using two independent multicenter datasets. Specifically, we first fine-tuned the KD-Informer with a large and high-quality dataset (Mindray dataset) and then transferred the pre-trained model to the target domain (MIMIC dataset). The experimental test results on the MIMIC dataset showed that the KD-Informer exhibited an estimation error of 0.02 ± 5.93 mmHg for systolic BP (SBP) and 0.01 ± 3.87 mmHg for diastolic BP (DBP), which complied with the association for the advancement of medical instrumentation (AAMI) standard. These results demonstrate that the KD-Informer has high reliability and elegant robustness to measure continuous BP waveforms.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Fotopletismografía , Humanos , Presión Sanguínea/fisiología , Fotopletismografía/métodos , Reproducibilidad de los Resultados , Determinación de la Presión Sanguínea/métodos , Análisis de la Onda del Pulso
10.
Biomed Opt Express ; 13(10): 5327-5343, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36425627

RESUMEN

Limited-projection fluorescence molecular tomography (FMT) allows rapid reconstruction of the three-dimensional (3D) distribution of fluorescent targets within a shorter data acquisition time. However, the limited-projection FMT is severely ill-posed and ill-conditioned due to insufficient fluorescence measurements and the strong scattering properties of photons in biological tissues. Previously, regularization-based methods, combined with the sparse distribution of fluorescent sources, have been commonly used to alleviate the severe ill-posed nature of the limited-projection FMT. Due to the complex iterative computations, time-consuming solution procedures, and less stable reconstruction results, the limited-projection FMT remains an intractable challenge for achieving fast and accurate reconstructions. In this work, we completely discard the previous iterative solving-based reconstruction themes and propose multi-branch attention prior based parameterized generative adversarial network (MAP-PGAN) to achieve fast and accurate limited-projection FMT reconstruction. Firstly, the multi-branch attention can provide parameterized weighted sparse prior information for fluorescent sources, enabling MAP-PGAN to effectively mitigate the ill-posedness and significantly improve the reconstruction accuracy of limited-projection FMT. Secondly, since the end-to-end direct reconstruction strategy is adopted, the complex iterative computation process in traditional regularization algorithms can be avoided, thus greatly accelerating the 3D visualization process. The numerical simulation results show that the proposed MAP-PGAN method outperforms the state-of-the-art methods in terms of localization accuracy and morphological recovery. Meanwhile, the reconstruction time is only about 0.18s, which is about 100 to 1000 times faster than the conventional iteration-based regularization algorithms. The reconstruction results from the physical phantoms and in vivo experiments further demonstrate the feasibility and practicality of the MAP-PGAN method in achieving fast and accurate limited-projection FMT reconstruction.

11.
IEEE Trans Med Imaging ; 41(12): 3812-3823, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35939461

RESUMEN

The accurate segmentation of multiple types of lesions from adjacent tissues in medical images is significant in clinical practice. Convolutional neural networks (CNNs) based on the coarse-to-fine strategy have been widely used in this field. However, multi-lesion segmentation remains to be challenging due to the uncertainty in size, contrast, and high interclass similarity of tissues. In addition, the commonly adopted cascaded strategy is rather demanding in terms of hardware, which limits the potential of clinical deployment. To address the problems above, we propose a novel Prior Attention Network (PANet) that follows the coarse-to-fine strategy to perform multi-lesion segmentation in medical images. The proposed network achieves the two steps of segmentation in a single network by inserting a lesion-related spatial attention mechanism in the network. Further, we also propose the intermediate supervision strategy for generating lesion-related attention to acquire the regions of interest (ROIs), which accelerates the convergence and obviously improves the segmentation performance. We have investigated the proposed segmentation framework in two applications: 2D segmentation of multiple lung infections in lung CT slices and 3D segmentation of multiple lesions in brain MRIs. Experimental results show that in both 2D and 3D segmentation tasks our proposed network achieves better performance with less computational cost compared with cascaded networks. The proposed network can be regarded as a universal solution to multi-lesion segmentation in both 2D and 3D tasks. The source code is available at https://github.com/hsiangyuzhao/PANet.


Asunto(s)
Imagen por Resonancia Magnética , Redes Neurales de la Computación , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos
12.
J Biomed Opt ; 27(7)2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35810324

RESUMEN

SIGNIFICANCE: Pharmacokinetic parametric images in dynamic fluorescence molecular tomography (FMT) can describe three-dimensional (3D) physiological and pathological information inside biological tissues, potentially providing quantitative assessment tools for biological research and drug development. AIM: In vivo imaging of the liver tumor with pharmacokinetic parametric images from dynamic FMT based on the differences in metabolic properties of indocyanine green (ICG) between normal liver cells and tumor liver cells inside biological tissues. APPROACH: First, an orthotopic liver tumor mouse model was constructed. Then, with the help of the FMT/computer tomography (CT) dual-modality imaging system and the direct reconstruction algorithm, 3D imaging of liver metabolic parameters in nude mice was achieved to distinguish liver tumors from normal tissues. Finally, pharmacokinetic parametric imaging results were validated against in vitro anatomical results. RESULTS: This letter demonstrates the ability of dynamic FMT to monitor the pharmacokinetic delivery of the fluorescent dye ICG in vivo, thus, enabling the distinction between normal and tumor tissues based on the pharmacokinetic parametric images derived from dynamic FMT. CONCLUSIONS: Compared with CT structural imaging technology, dynamic FMT combined with compartmental modeling as an analytical method can obtain quantitative images of pharmacokinetic parameters, thus providing a more powerful research tool for organ function assessment, disease diagnosis and new drug development.


Asunto(s)
Neoplasias Hepáticas , Tomografía , Animales , Colorantes Fluorescentes/farmacocinética , Células Hep G2 , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas/diagnóstico por imagen , Ratones , Ratones Desnudos , Trasplante de Neoplasias , Tomografía/métodos
13.
Front Pharmacol ; 13: 897597, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35833032

RESUMEN

Objectives: We aimed to identify whether ensemble learning can improve the performance of the epidermal growth factor receptor (EGFR) mutation status predicting model. Methods: We retrospectively collected 168 patients with non-small cell lung cancer (NSCLC), who underwent both computed tomography (CT) examination and EGFR test. Using the radiomics features extracted from the CT images, an ensemble model was established with four individual classifiers: logistic regression (LR), support vector machine (SVM), random forest (RF), and extreme gradient boosting (XGBoost). The synthetic minority oversampling technique (SMOTE) was also used to decrease the influence of data imbalance. The performances of the predicting model were evaluated using the area under the curve (AUC). Results: Based on the 26 radiomics features after feature selection, the SVM performed best (AUCs of 0.8634 and 0.7885 on the training and test sets, respectively) among four individual classifiers. The ensemble model of RF, XGBoost, and LR achieved the best performance (AUCs of 0.8465 and 0.8654 on the training and test sets, respectively). Conclusion: Ensemble learning can improve the model performance in predicting the EGFR mutation status of patients with NSCLC, showing potential value in clinical practice.

14.
Med Phys ; 49(11): 6960-6974, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35715882

RESUMEN

PURPOSE: The non-small cell lung cancer (NSCLC) can be divided into adenocarcinoma (ADC), squamous cell carcinoma (SCC), large cell carcinoma (LCC), and not otherwise specified (NOS), which is crucial for clinical decision-making. However, current related researches are rare for the complex multi-classification of NSCLC, mainly due to the serious data imbalance, the difficulty to unify the feature space, and the complicated decision boundary among multiple subtypes. The machine learning method of traditional "one-vs-one" (OVO) is difficult to solve these problems and achieve good results. METHODS: To this end, we propose a novel independent subtask learning (ISTL) method to better carry out the multi-classification task. Specifically, it includes four pertinent strategies: (1) independent data expansion; (2) independent feature selection (IFS); (3) independent model construction; and (4) a novel voting strategy: majority voting combined with Bayesian prior. We performed experiments using 1036 CT scans (ADC:SCC:LCC:NOS = 600:268:105:63) collected from eight international databases, and the data acquisition was highly complex and diverse. RESULTS: The experimental results showed that the ISTL method obtained an accuracy of 0.812 on the independent test cohort, which significantly improved the performance of multi-classification compared with the traditional OVO-support vector machine (0.691) and OVO-random forest (0.710) models. After the IFS, six selected feature sets of six binary tasks are obviously different, indicating that the ISTL method has better interpretability to distinguish the multiple NSCLC subtypes. The results of a further auxiliary contrast experiment showed that four pertinent strategies were all effective. CONCLUSION: Our work indicates that the ISTL method can effectively perform multi-classification of NSCLC subtypes with better interpretability for clinical computer-aided detection and has the potential to be applied in a wide range of multi-classification studies.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Teorema de Bayes , Neoplasias Pulmonares/diagnóstico por imagen
15.
Comput Methods Programs Biomed ; 219: 106741, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35338882

RESUMEN

BACKGROUND: Current clinical assessments of essential tremor (ET) are primarily based on expert consultation combined with reviewing patient complaints, physician expertise, and diagnostic experience. Thus, traditional evaluation methods often lead to biased diagnostic results. There is a clinical demand for a method that can objectively quantify the severity of the patient's disease. METHODS: This study aims to develop an artificial intelligence-aided diagnosis method based on multi-sensory fusion wearables. The experiment relies on a rigorous clinical trial paradigm to collect multi-modal fusion of signals from 98 ET patients. At the same time, three clinicians scored independently, and the consensus score obtained was used as the ground truth for the machine learning models. RESULTS: Sixty kinematic parameters were extracted from the signals recorded by the nine-axis inertial measurement unit (IMU). The results showed that most of the features obtained by IMU could effectively characterize the severity of the tremors. The accuracy of the optimal model for three tasks classifying five severity levels was 97.71%, 97.54%, and 97.72%, respectively. CONCLUSIONS: This paper reports the first attempt to combine multiple feature selection and machine learning algorithms for fine-grained automatic quantification of postural tremor in ET patients. The promising results showed the potential of the proposed approach to quantify the severity of ET objectively.


Asunto(s)
Inteligencia Artificial , Temblor , Algoritmos , Fenómenos Biomecánicos , Humanos , Aprendizaje Automático , Temblor/diagnóstico
16.
Phys Med Biol ; 67(10)2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35276686

RESUMEN

Objective.Fluorescence molecular tomography (FMT) is a promising non-invasive optical molecular imaging technology with strong specificity and sensitivity that has great potential for preclinical and clinical studies in tumor diagnosis, drug development and therapeutic evaluation. However, the strong scattering of photons and insufficient surface measurements make it very challenging to improve the quality of FMT image reconstruction and its practical application for early tumor detection. Therefore, continuous efforts have been made to explore more effective approaches or solutions in the pursuit of high-quality FMT reconstructions.Approach.This review takes a comprehensive overview of advances in imaging methodology for FMT, mainly focusing on two critical issues in FMT reconstructions: improving the accuracy of solving the forward physical model and mitigating the ill-posed nature of the inverse problem from a methodological point of view. More importantly, numerous impressive and practical strategies and methods for improving the quality of FMT reconstruction are summarized. Notably, deep learning methods are discussed in detail to illustrate their advantages in promoting the imaging performance of FMT thanks to large datasets, the emergence of optimized algorithms and the application of innovative networks.Main results.The results demonstrate that the imaging quality of FMT can be effectively promoted by improving the accuracy of optical parameter modeling, combined with prior knowledge, and reducing dimensionality. In addition, the traditional regularization-based methods and deep neural network-based methods, especially end-to-end deep networks, can enormously alleviate the ill-posedness of the inverse problem and improve the quality of FMT image reconstruction.Significance.This review aims to illustrate a variety of effective and practical methods for the reconstruction of FMT images that may benefit future research. Furthermore, it may provide some valuable research ideas and directions for FMT in the future, and could promote, to a certain extent, the development of FMT and other methods of optical tomography.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Óptica , Algoritmos , Fluorescencia , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Molecular/métodos , Redes Neurales de la Computación , Fantasmas de Imagen , Tomografía/métodos , Tomografía Computarizada por Rayos X
17.
Langmuir ; 37(49): 14314-14322, 2021 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-34865489

RESUMEN

Inspired by natural creatures, superhydrophobic surfaces with various adhesion behaviors have attracted significant scientific interest. In this study, by controlling the laser fluence, the scanning times, and the subsequent cleaning method, microcolumn arrays with different morphologies were fabricated on 304 stainless-steel surfaces using picosecond laser direct writing. To achieve wettability transition, the laser-processed samples were then subjected to heat treatments (120 °C) in air and in a low vacuum environment (6 kPa). The results show that after heat treatment in different environments and with various time lengths, the laser-processed surfaces become hydrophobic surfaces with different adhesion properties. It is worth noting that while surfaces heat-treated in air exhibit weak wettability transition potential and high adhesion, the surfaces heat-treated in a low vacuum environment present superhydrophobic and low adhesion properties with a minimum sliding angle of about 3.14°. Moreover, the low-vacuum heat-treated surfaces retain good superhydrophobic properties after 1 month of observation as well as an abrasion test. These transitions in hydrophobic behavior and adhesion properties may be mainly attributed to the heat treatment-induced (in the air or in a low vacuum environment) redistribution of surface compounds and the microstructure-induced alternation of the solid-liquid contact state. By controlling the laser processing parameters and the heat treatment time and environment, stable wettability transition and flexible adhesion control of stainless steel can be easily achieved.

18.
Comput Biol Med ; 139: 104880, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34700255

RESUMEN

BACKGROUND AND OBJECTIVE: Atrial fibrillation (AF) is the most common persistent cardiac arrhythmia in clinical practice, and its accurate screening is of great significance to avoid cardiovascular diseases (CVDs). Electrocardiogram (ECG) is considered to be the most commonly used technique for detecting AF abnormalities. However, previous ECG-based deep learning algorithms did not take into account the complementary nature of inter-layer information, which may lead to insufficient AF screening. This study reports the first attempt to use hybrid multi-scale information in a global space for accurate and robust AF detection. METHODS: We propose a novel deep learning classification method, namely, global hybrid multi-scale convolutional neural network (i.e., GH-MS-CNN), to implement binary classification for AF detection. Unlike previous deep learning methods in AF detection, an ingenious hybrid multi-scale convolution (HMSC) module, for the advantage of automatically aggregating different types of complementary inter-layer multi-scale features in the global space, is introduced into all dense blocks of the GH-MS-CNN model to implement sufficient feature extraction, and achieve much better overall classification performance. RESULTS: The proposed GH-MS-CNN method has been fully validated on the CPSC 2018 database and tested on the independent PhysioNet 2017 database. The experimental results show that the global and hybrid multi-scale information has tremendous advantages over local and single-type multi-scale information in AF screening. Furthermore, the proposed GH-MS-CNN method outperforms the state-of-the-art methods and achieves the best classification performance with an accuracy of 0.9984, a precision of 0.9989, a sensitivity of 0.9965, a specificity of 0.9998 and an F1 score of 0.9954. In addition, the proposed method has achieved comparable and considerable generalization capability on the PhysioNet 2017 database. CONCLUSIONS: The proposed GH-MS-CNN method has promising capabilities and great advantages in accurate and robust AF detection. It is assumed that this research has made significant improvements in AF screening and has great potential for long-term monitoring of wearable devices.


Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Algoritmos , Fibrilación Atrial/diagnóstico , Electrocardiografía , Humanos , Redes Neurales de la Computación
19.
JMIR Mhealth Uhealth ; 9(8): e25415, 2021 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-34387554

RESUMEN

BACKGROUND: With the development and promotion of wearable devices and their mobile health (mHealth) apps, physiological signals have become a research hotspot. However, noise is complex in signals obtained from daily lives, making it difficult to analyze the signals automatically and resulting in a high false alarm rate. At present, screening out the high-quality segments of the signals from huge-volume data with few labels remains a problem. Signal quality assessment (SQA) is essential and is able to advance the valuable information mining of signals. OBJECTIVE: The aims of this study were to design an SQA algorithm based on the unsupervised isolation forest model to classify the signal quality into 3 grades: good, acceptable, and unacceptable; validate the algorithm on labeled data sets; and apply the algorithm on real-world data to evaluate its efficacy. METHODS: Data used in this study were collected by a wearable device (SensEcho) from healthy individuals and patients. The observation windows for electrocardiogram (ECG) and respiratory signals were 10 and 30 seconds, respectively. In the experimental procedure, the unlabeled training set was used to train the models. The validation and test sets were labeled according to preset criteria and used to evaluate the classification performance quantitatively. The validation set consisted of 3460 and 2086 windows of ECG and respiratory signals, respectively, whereas the test set was made up of 4686 and 3341 windows of signals, respectively. The algorithm was also compared with self-organizing maps (SOMs) and 4 classic supervised models (logistic regression, random forest, support vector machine, and extreme gradient boosting). One case validation was illustrated to show the application effect. The algorithm was then applied to 1144 cases of ECG signals collected from patients and the detected arrhythmia false alarms were calculated. RESULTS: The quantitative results showed that the ECG SQA model achieved 94.97% and 95.58% accuracy on the validation and test sets, respectively, whereas the respiratory SQA model achieved 81.06% and 86.20% accuracy on the validation and test sets, respectively. The algorithm was superior to SOM and achieved moderate performance when compared with the supervised models. The example case showed that the algorithm was able to correctly classify the signal quality even when there were complex pathological changes in the signals. The algorithm application results indicated that some specific types of arrhythmia false alarms such as tachycardia, atrial premature beat, and ventricular premature beat could be significantly reduced with the help of the algorithm. CONCLUSIONS: This study verified the feasibility of applying the anomaly detection unsupervised model to SQA. The application scenarios include reducing the false alarm rate of the device and selecting signal segments that can be used for further research.


Asunto(s)
Electrocardiografía , Dispositivos Electrónicos Vestibles , Algoritmos , Arritmias Cardíacas , Humanos , Máquina de Vectores de Soporte
20.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 38(3): 583-593, 2021 Jun 25.
Artículo en Chino | MEDLINE | ID: mdl-34180205

RESUMEN

Wearable physiological parameter monitoring devices play an increasingly important role in daily health monitoring and disease diagnosis/treatment due to their continuous dynamic and low physiological/psychological load characteristics. After decades of development, wearable technologies have gradually matured, and research has expanded to clinical applications. This paper reviews the research progress of wearable physiological parameter monitoring technology and its clinical applications. Firstly, it introduces wearable physiological monitoring technology's research progress in terms of sensing technology and data processing and analysis. Then, it analyzes the monitoring physiological parameters and principles of current medical-grade wearable devices and proposes three specific directions of clinical application research: 1) real-time monitoring and predictive warning, 2) disease assessment and differential diagnosis, and 3) rehabilitation training and precision medicine. Finally, the challenges and response strategies of wearable physiological monitoring technology in the biomedical field are discussed, highlighting its clinical application value and clinical application mode to provide helpful reference information for the research of wearable technology-related fields.


Asunto(s)
Dispositivos Electrónicos Vestibles , Monitoreo Fisiológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA