Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Endosc Ultrasound ; 10(6): 440-447, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34975042

RESUMEN

BACKGROUND AND OBJECTIVES: There is no clear evidence of a negative impact of biliary stents on the diagnostic yield of EUS-guided fine-needle biopsy (EUS-FNB) for diagnosing pancreatic head lesions. We aimed to evaluate the association between the presence of biliary stents and the diagnostic accuracy of EUS-FNB. MATERIALS AND METHODS: A multicenter retrospective study including all jaundiced patients secondary to pancreatic head masses was performed. Patients were divided into two groups according to the presence of a biliary stent placed before EUS-FNB. Pathological results were classified according to the Papanicolaou classification and compared against the final diagnosis. Diagnostic measures in the two groups were compared. Multivariate logistic regression analyses including potential factors affecting EUS-FNB accuracy were performed. RESULTS: Overall, 842 patients were included, 495 (58.8%) without and 347 (41.2%) with biliary stent. A plastic or a metal stent was placed in 217 (62.5%) and 130 (37.5%) cases, respectively. Diagnostic sensitivity and accuracy were significantly higher in patients without biliary stent than in those with stent (91.9% and 92.1% vs. 85.9% and 86.4%, P = 0.010 At multivariate analyses, lesion size (odds ratio [OR]: 1.05, 95% confidence interval [CI]: 1.02-1.09, P = 0.01) and presence of biliary stent (OR: 0.51, 95% CI: 0.32-0.89, P = 0.01) were independently associated with diagnostic accuracy. In the subgroup of patients with biliary stent, the type of stent (plastic vs. metal) did not impact EUS-FNB yield, whereas the use of larger bore needles enhanced diagnostic accuracy (OR: 2.29, 95% CI: 1.28-4.12, P = 0.005). CONCLUSIONS: In this large retrospective study, an indwelling biliary stent negatively impacted the diagnostic accuracy of EUS-FNB. Preferably, EUS-FNB should precede endoscopic retrograde cholangiopancreatography, especially in the case of small tumors.

2.
Pancreas ; 49(6): 793-798, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32541636

RESUMEN

OBJECTIVE: To evaluate a rapid checklist capable of identifying exocrine pancreatic insufficiency in outpatients. METHODS: Prospective observational study of a multicenter cohort. RESULTS: One hundred and two patients were enrolled; 61.8% of the patients had medically-treated benign or malignant pancreatic disease, and 38.2% had a pancreatic resection. Visual examination of the feces was evaluated in 84 patients and it was related to steatorrhea in 51 patients (50.0%). Receiver operating characteristic curves were evaluated for each symptom or clinical sign and four of them (ie, increase in daily bowel movements, number of bowel movements, fatty stools, >10% weight loss) had a satisfactory area under the curve. At multivariate analysis, fatty stools and >10% weight loss entered into this analysis having an area under the curve of 0.916 (95% confidence interval, 0.851-0.981). At 1 month and at one year of follow-up, the pancreatic enzyme replacement therapy administered showed that pancreatic extracts were able to significantly improve the increase in daily bowel movements, the number of bowel movements, fatty and bulky stools and >10% weight loss. CONCLUSION: Both fatty stools and >10% weight loss were able to clinically evaluate steatorrhea, and their improvement was sufficient to evaluate substitution therapy.


Asunto(s)
Lista de Verificación/estadística & datos numéricos , Insuficiencia Pancreática Exocrina/diagnóstico , Pacientes Ambulatorios/estadística & datos numéricos , Sistema de Registros/estadística & datos numéricos , Adulto , Anciano , Terapia de Reemplazo Enzimático/métodos , Insuficiencia Pancreática Exocrina/fisiopatología , Insuficiencia Pancreática Exocrina/terapia , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Pruebas de Función Pancreática/métodos , Estudios Prospectivos , Curva ROC
3.
Endosc Ultrasound ; 9(2): 122-129, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32295970

RESUMEN

Background and Objective: EUS-FNA sensitivity for malignancy in parenchymal masses of patients with concurrent chronic pancreatitis (CP) has been reported to be unsatisfactory. The aim of the present study was to directly compare the diagnostic accuracy of EUS-FNA and EUS-fine-needle biopsy (FNB) in differentiating between inflammatory masses and malignancies in the setting of CP. Methods: We performed a retrospective analysis of prospective, multicentric databases of all patients with pancreatic masses and clinico-radiological-endosonographic features of CP who underwent EUS-FNA or FNB. Results: Among 1124 patients with CP, 210 patients (60% males, mean age: 62.7 years) with CP and pancreatic masses met the inclusion criteria and were enrolled. In the FNA group (110 patients), a correct diagnosis was obtained in all but 18 cases (diagnostic accuracy 83.6%, sensitivity 69.5%, specificity 100%, positive predictive value [PPV] 100%, and negative predictive value [NPV] 73.9%); by contrast, among 100 patients undergoing FNB, a correct diagnosis was obtained in all but seven cases (diagnostic accuracy 93%, sensitivity 86.8%, specificity 100%, PPV 100%, and NPV 87%) (P = 0.03, 0.03, 1, 1, and 0.07, respectively). At binary logistic regression, focal pancreatitis (odds of event occurrence [OR]: 4.9; P < 0.001), higher Ca19-9 (OR: 2.3;P= 0.02), and FNB (OR: 2.5; P < 0.01) were the only independent factors associated with a correct diagnosis. Conclusion: EUS-FNB is effective in the differential diagnosis between pseudotumoral masses and solid neoplasms in CP, showing higher diagnostic accuracy and sensitivity than EUS-FNA. EUS-FNB should be considered the preferred diagnostic technique for diagnosing cancer in the setting of CP.

4.
Dig Liver Dis ; 52(5): 547-554, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32122771

RESUMEN

INTRODUCTION: A prospective survey to evaluate the diagnostic workup of cystic pancreatic neoplasms (CPNs) according to the Italian guidelines. METHODS: An online data sheet was built. RESULTS: Fifteen of the 1385 patients (1.1%) had non cystic neoplastic lesions. Forty percent (518/1295) had at least one 1st degree relative affected by a solid tumor of the digestive and extra-digestive organs. Symptoms/signs associated with the cystic lesion were present in 24.5% of the patients. The cysts were localized in the head of the pancreas in 38.5% of patients. Of the 2370 examinations (1.7 examinations per patient) which were carried out for the diagnosis, magnetic resonance imaging was performed as a single test in 48.4% of patients and in combination with endoscopic ultrasound in 27% of the cases. Of the 1370 patients having CPNs, 89.9% had an intraductal papillary mucinous neoplasm (IPMN) (70.1% a branch duct IPMN, 6.2% a mixed type IPMN and 4.6% a main duct IPMN), 12.7% had a serous cystadenoma, 2.8% a mucinous cystadenoma, 1.5% a non-functioning cystic neuroendocrine neoplasm, 0.7% a solid-pseudopapillary cystic neoplasm, 0.3% a cystic adenocarcinoma, and 1.2% an undetermined cystic neoplasm. Seventy-eight (5.7%) patients were operated upon after the initial work-up. CONCLUSIONS: This prospective study offers a reliable real-life picture of the diagnostic work-up CPN.


Asunto(s)
Cistoadenoma Mucinoso/epidemiología , Cistadenoma Seroso/epidemiología , Páncreas/diagnóstico por imagen , Páncreas/patología , Neoplasias Pancreáticas/epidemiología , Adenocarcinoma/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Endosonografía , Femenino , Humanos , Italia/epidemiología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/epidemiología , Guías de Práctica Clínica como Asunto , Estudios Prospectivos , Encuestas y Cuestionarios , Adulto Joven
5.
Dig Liver Dis ; 52(2): 178-184, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31601535

RESUMEN

BACKGROUND: Standard suction and slow-pull techniques have been utilized during endoscopic ultrasound-guided fine needle aspiration of pancreatic solid lesions, but the correct sampling technique remains unclear. New needles designed to obtain samples suitable for histological evaluation have become available. We performed a study comparing the two sampling methods during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in patients with pancreatic solid lesions. METHODS: We performed EUS-FNB with a 20 Gauge FNB needle using slow-pull or standard suction techniques in a prospective, randomized, multicenter study. The primary aim was bloodiness of the collected specimens. Secondary aims were technical success and performance of the two techniques. RESULTS: 110 patients were included (55 per group). No difference in blood contamination was observed (slow-pull 80% vs. suction 74%, p = 0.917). Technical success was 95% (96% vs. 94%, p = 0315). Sensitivity (96% vs. 93%), specificity (100% vs. 100%), positive likelihood ratio (NA), negative likelihood ratio (0.04 vs. 0.07), diagnostic accuracy (96 vs. 93%) did not differ between the two groups. CONCLUSION: EUS-FNB with slow-pull and standard suction techniques are comparable in terms of blood contamination providing similar high diagnostic sensitivity and accuracy in pancreatic solid lesions. The use of the new generation FNB needle allows to reach such high level of diagnostic adequacy regardless of the technique utilized.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Agujas , Neoplasias Pancreáticas/patología , Succión/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/patología , Estudios Prospectivos , Sensibilidad y Especificidad
7.
Endosc Ultrasound ; 8(4): 261-268, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31115386

RESUMEN

BACKGROUND AND OBJECTIVE: EUS-guided fine-needle biopsy has become the standard for tissue sampling. A new 20G ProCore™ (PC) needle has been developed to overcome the limitations of tissue acquisition of the smaller needles (22G, 25G) and the rigidity of the larger one (19G). The aim of this study is to assess the performance of the 20G PC needle. MATERIALS AND METHODS: Patients who underwent EUS-guided tissue acquisition with the 20G PC needle of pancreatic and extra-pancreatic mass lesions were retrospectively identified at three Italian centers (Bologna, Fermo, and Palermo). Diagnostic adequacy, accuracy, and tissue core acquisition were the outcome measures. All the cases were performed without rapid on-site evaluation. RESULTS: A total of 384 patients with pancreatic (62.2%) and extra-pancreatic lesions were included in the study. For pancreatic lesions, adequacy, accuracy, sensitivity, and specificity were 92.4%, 91.5%, 90.8%, and 100%, respectively, with a number needed to misdiagnose (NNM) of 11.8. The tissue core was obtained in 72% of cases. Transduodenal approach was performed in 150 pancreatic lesions; adequacy, accuracy, and tissue core acquisition were 88.7%, 90%, and 66%, respectively (NNM 10). For extrapancreatic lesions, adequacy, accuracy, sensitivity, specificity, and tissue core sampling were 95.3%, 95.3%, 92.6%, 100%, and 84.5% (NNM 21.3). CONCLUSIONS: The 20G PC needle showed high diagnostic adequacy and accuracy, regardless the access route.

8.
Endosc Ultrasound ; 8(2): 105-110, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29770781

RESUMEN

BACKGROUND AND OBJECTIVE: A new 20-gauge (G) biopsy needle with a core-trap technology has been developed with a large core size and enhanced flexibility. The aim of this multicenter study was to determine the feasibility, efficacy, and safety of EUS-guided fine-needle biopsy (EUS-FNB) with the new 20G needle in diagnosing subepithelial lesions (SELs). MATERIALS AND METHODS: Retrospectively collected data from consecutive patients with SELs undergoing EUS-FNB with the 20G needle at five centers were analyzed. RESULTS: A total of 50 SELs were included. The mean lesion size was 43.1 ± 17.5 mm. The lesion locations were esophagus (n = 1), stomach (n = 37), distal duodenum (n = 5), rectum (n = 6), and colon (n = 1). The procedure was technically feasible in all patients. Definitive diagnosis with full histological assessment including immunohistochemistry was obtained in 88% (44/50) of the patients. Considering malignant versus benign lesions, the sensitivity, specificity, positive predictive value, and negative predictive value were 85% (95% confidence interval [CI] 70.2-94.3), 100% (95% CI 58.7%-100%), 100% (95% CI 85.1%-100%), and 62.5 (95% CI 27.7-84.8), respectively. No major complications requiring additional care have been observed. CONCLUSIONS: In this multicenter study, we found that EUS-FNB with the new 20G core needle is an effective and safe method for the diagnosis of SELs with a high rate of producing adequate histological material and high diagnostic accuracy even from difficult-to-approach anatomical locations.

10.
Endosc Int Open ; 6(7): E892-E897, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29978011

RESUMEN

BACKGROUND AND STUDY AIMS: This study was designed to evaluate the impact of additional tissue obtained with endoscopic ultrasound (EUS)-guided 25-gauge core biopsy needle (25G-PC) following an unsuccessful fine-needle biopsy (FNB) performed with larger-bore needles for the characterization of gastrointestinal subepithelial lesions (GI-SELs). PATIENTS AND METHODS: We prospectively collected and retrospectively analyzed information in our database from January 2013 to June 2017 for all patients with GI-SELs who received a EUS-guided FNB (EUS-FNB) with 25G-PC during the same procedure after failure of biopsy performed with larger-bore needle. Diagnostic yield, diagnostic accuracy and procedural complications were evaluated. RESULTS: Sixteen patients were included in this study, 10 men and 6 women, median age 67.8 (range 43 to 76 years). Five patients were found to have a SEL localized in the distal duodenum, five in the gastric antrum, two in the gastric fundus and four in the gastric body. The mean size of the lesions was 20.5 mm (range 18 - 24 mm). EUS-FNB with 25G-PC enabled final diagnosis in nine patients (56.2 %). Regarding the subgroup of duodenal lesions, the procedure was successful in four of five (80 %). Final diagnoses with EUS-guided sampling were GIST (n = 6), leiomyoma (n = 2) and metastatic ovarian carcinoma (n = 1). No procedure-related complications were recorded. CONCLUSION: In patients with small GI-SELs, additional tissue obtained with 25G-PC could represents a "rescue" strategy after an unsuccessful procedure with larger-bore needles, especially when lesions are localized in the distal duodenum.

11.
Dig Liver Dis ; 50(1): 1-5, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29170072

RESUMEN

Exocrine pancreatic insufficiency (EPI) is one of the possible mechanisms of fat maldigestion following gastric surgery, together with reduced food intake, loss of gastric reservoir, small bowel bacterial overgrowth and rapid small bowel transit. Oral pancreatic enzyme replacement therapy (PERT) is the mainstay of treatment for EPI. The efficacy and safety of pancreatic enzyme substitution in patients following gastric resection remains unclear. This review article summarizes relevant studies addressing PERT after gastric resection.


Asunto(s)
Terapia de Reemplazo Enzimático/métodos , Insuficiencia Pancreática Exocrina/tratamiento farmacológico , Gastrectomía/efectos adversos , Páncreas/efectos de los fármacos , Insuficiencia Pancreática Exocrina/etiología , Insuficiencia Pancreática Exocrina/fisiopatología , Fármacos Gastrointestinales/uso terapéutico , Humanos , Páncreas/enzimología , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
World J Gastrointest Oncol ; 9(11): 452-456, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-29204254

RESUMEN

We describe an uncommon case of a patient with a metastatic adenocarcinoma of ovarian origin presented as a gastric subepithelial tumor (SET) and that was diagnosed by endoscopic ultrasound fine-needle biopsy (EUS-FNB). Malignant gastric lesions are rarely metastatic and the primary tumor is mainly breast, lung, esophageal cancer or cutaneous melanoma. Gastric metastasis from ovarian cancer is unusual, presenting synchronously with the primary tumor but also several years later than the initial diagnosis. From an endoscopic point of view, gastric metastasis does not present specific features. They may mimic both a primary gastric tumor or, less frequently, an SET. This case demonstrates the importance of EUS-FNB in distinguishing SETs and how this may alter treatment and prognosis.

17.
Dig Liver Dis ; 49(8): 898-902, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28465092

RESUMEN

OBJECTIVE: While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. METHODS: All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. RESULTS: A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. CONCLUSION: The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Biliar , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Páncreas/patología , Neoplasias Pancreáticas/patología , Stents , Anciano , Femenino , Humanos , Italia , Ictericia Obstructiva/etiología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Plásticos , Análisis de Regresión , Estudios Retrospectivos , Sensibilidad y Especificidad , Centros de Atención Terciaria
19.
Pancreas ; 46(4): 524-527, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28196017

RESUMEN

OBJECTIVES: We have previously shown that at least 50% of patients with asymptomatic chronic pancreatic hyperenzymemia (ACPH) may develop morphological pancreatic alterations. Endoscopic ultrasonography (EUS) may detect small lesions, and its sensitivity seems to be higher than other imaging techniques. The aim of this study was to evaluate whether EUS may modify the management of patients having ACPH. METHODS: In 2 referral centers for pancreatic disease, a retrospective analysis of prospectively enrolled patients with ACPH was conducted. RESULTS: Seventy-three patients with ACPH were enrolled for the purpose of this study. Endoscopic ultrasonography was performed as the last examination in 45 subjects who resulted negative at previous imaging studies (abdominal ultrasound, computed tomography, magnetic resonance imaging associated with cholangiopancreatography). Using EUS in 7 subjects, abnormalities were found in the following: 3 branch-duct intraductal papillary mucinous neoplasms, 1 duodenal diverticulum, 1 annular pancreas, 1 findings suggestive of chronic pancreatitis, and 1 undefined cyst (<5 mm). CONCLUSIONS: Endoscopic ultrasonography is able to detect alteration not found by other imaging technique in 15.5% of patients with ACPH and may be useful to select those patients who require a more strict follow-up.


Asunto(s)
Endosonografía/métodos , Pancreatitis Crónica/diagnóstico por imagen , Pancreatitis Crónica/enzimología , Adulto , Anciano , Anciano de 80 o más Años , Amilasas/sangre , Femenino , Estudios de Seguimiento , Humanos , Lipasa/sangre , Masculino , Persona de Mediana Edad , Pancreatitis Crónica/sangre , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tripsina/sangre , Adulto Joven
20.
Surg Endosc ; 31(1): 225-230, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27194261

RESUMEN

BACKGROUND: Rapid on-site evaluation (ROSE) improves the adequacy and accuracy of EUS-guided tissue acquisition, although it is not routinely widely available. Evidence suggested that core needles might overcome the absence of ROSE. The aim of this study was to evaluate the influence of ROSE on the adequacy and accuracy of EUS-guided tissue acquisition with core needles in patients with pancreatic solid lesions. METHODS: Patients who underwent EUS-guided tissue acquisition of pancreatic mass lesions were retrospectively identified at three tertiary referral centers and those performed with the core needle were included. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without ROSE was the primary outcome measure. The diagnostic accuracy and tissue core acquisition were the secondary outcome measures. RESULTS: A total of 333 patients with pancreatic solid mass lesions were included in the study; 140 cases sampled with ROSE and 193 cases without ROSE. The adequacy was 92.1 % in the group sampled with ROSE and 88.1 % in the group without ROSE (p = 0.227). In the ROSE group sensitivity, specificity, and accuracy were 90.7, 100 and 92.1 %, respectively. In the group without ROSE, sensitivity, specificity, and accuracy were 87.2, 100, and 88.1 %, respectively. No difference for all these figures was observed between the two groups. The tissue core was available in 61.4 and 53.4 % of cases with and without ROSE, respectively (p = 0.143). CONCLUSION: In the absence of ROSE, EUS-based tissue acquisition with Core needle should be considered since it achieves comparable tissue sampling adequacy and accuracy.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas/patología , Adenocarcinoma/patología , Anciano , Carcinoma Neuroendocrino/patología , Femenino , Humanos , Masculino , Páncreas/patología , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...