Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Eur J Endocrinol ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38917410

RESUMEN

OBJECTIVE: Brown adipose tissue (BAT) is a therapeutic target for obesity. 18F-Fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is commonly used to quantify human BAT mass and activity. Detectable 18F-FDG uptake by BAT is associated with reduced prevalence of cardiometabolic disease. However, 18F-FDG uptake may not always be a reliable marker of BAT thermogenesis, for example insulin resistance may reduce glucose uptake. Uncoupling protein 1 (UCP1) is the key thermogenic protein in BAT. Therefore, we hypothesized that UCP1 expression may be altered in individuals with cardiometabolic risk factors. METHODS: We quantified UCP1 expression as an alternative marker of thermogenic capacity in BAT and white adipose tissue (WAT) samples (n = 53) and in differentiated brown and white pre-adipocytes (n = 85). RESULTS: UCP1 expression in BAT, but not in WAT or brown/white differentiated pre-adipocytes, was reduced with increasing age, obesity and adverse cardiometabolic risk factors such as fasting glucose, insulin and blood pressure. However, UCP1 expression in BAT was preserved in obese subjects of <40 years of age. To determine if BAT activity was also preserved in vivo, we undertook a case-control study, performing 18F-FDG scanning during mild cold exposure in young (mean age ∼22y) normal weight and obese volunteers. 18F-FDG uptake by BAT and BAT volume were similar between groups, despite increased insulin resistance. CONCLUSION: 18F-FDG uptake by BAT and UCP1 expression are preserved in young obese adults. Older subjects retain precursor cells with the capacity to form new thermogenic adipocytes. These data highlight the therapeutic potential of BAT mass expansion and activation in obesity.

2.
Eur J Nucl Med Mol Imaging ; 51(8): 2260-2270, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38456972

RESUMEN

INTRODUCTION: Non-invasive detection of pathological changes in thoracic aortic disease remains an unmet clinical need particularly for patients with congenital heart disease. Positron emission tomography combined with magnetic resonance imaging (PET-MRI) could provide a valuable low-radiation method of aortic surveillance in high-risk groups. Quantification of aortic microcalcification activity using sodium [18F]fluoride holds promise in the assessment of thoracic aortopathies. We sought to evaluate aortic sodium [18F]fluoride uptake in PET-MRI using three methods of attenuation correction compared to positron emission tomography computed tomography (PET-CT) in patients with bicuspid aortic valve, METHODS: Thirty asymptomatic patients under surveillance for bicuspid aortic valve disease underwent sodium [18F]fluoride PET-CT and PET-MRI of the ascending thoracic aorta during a single visit. PET-MRI data were reconstructed using three iterations of attenuation correction (Dixon, radial gradient recalled echo with two [RadialVIBE-2] or four [RadialVIBE-4] tissue segmentation). Images were qualitatively and quantitatively analysed for aortic sodium [18F]fluoride uptake on PET-CT and PET-MRI. RESULTS: Aortic sodium [18F]fluoride uptake on PET-MRI was visually comparable with PET-CT using each reconstruction and total aortic standardised uptake values on PET-CT strongly correlated with each PET-MRI attenuation correction method (Dixon R = 0.70; RadialVIBE-2 R = 0.63; RadialVIBE-4 R = 0.64; p < 0.001 for all). Breathing related artefact between soft tissue and lung were detected using Dixon and RadialVIBE-4 but not RadialVIBE-2 reconstructions, with the presence of this artefact adjacent to the atria leading to variations in blood pool activity estimates. Consequently, quantitative agreements between radiotracer activity on PET-CT and PET-MRI were most consistent with RadialVIBE-2. CONCLUSION: Ascending aortic microcalcification analysis in PET-MRI is feasible with comparable findings to PET-CT. RadialVIBE-2 tissue attenuation correction correlates best with the reference standard of PET-CT and is less susceptible to artefact. There remain challenges in segmenting tissue types in PET-MRI reconstructions, and improved attenuation correction methods are required.


Asunto(s)
Aorta Torácica , Imagen por Resonancia Magnética , Imagen Multimodal , Humanos , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Imagen Multimodal/métodos , Aorta Torácica/diagnóstico por imagen , Adulto , Calcinosis/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
3.
Nat Metab ; 5(8): 1319-1336, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37537371

RESUMEN

Activation of brown adipose tissue (BAT) in humans is a strategy to treat obesity and metabolic disease. Here we show that the serotonin transporter (SERT), encoded by SLC6A4, prevents serotonin-mediated suppression of human BAT function. RNA sequencing of human primary brown and white adipocytes shows that SLC6A4 is highly expressed in human, but not murine, brown adipocytes and BAT. Serotonin decreases uncoupled respiration and reduces uncoupling protein 1 via the 5-HT2B receptor. SERT inhibition by the selective serotonin reuptake inhibitor (SSRI) sertraline prevents uptake of extracellular serotonin, thereby potentiating serotonin's suppressive effect on brown adipocytes. Furthermore, we see that sertraline reduces BAT activation in healthy volunteers, and SSRI-treated patients demonstrate no 18F-fluorodeoxyglucose uptake by BAT at room temperature, unlike matched controls. Inhibition of BAT thermogenesis may contribute to SSRI-induced weight gain and metabolic dysfunction, and reducing peripheral serotonin action may be an approach to treat obesity and metabolic disease.


Asunto(s)
Tejido Adiposo Pardo , Enfermedades Metabólicas , Humanos , Ratones , Animales , Tejido Adiposo Pardo/metabolismo , Serotonina/metabolismo , Sertralina/metabolismo , Sertralina/farmacología , Proteínas de Transporte de Serotonina en la Membrana Plasmática/genética , Proteínas de Transporte de Serotonina en la Membrana Plasmática/metabolismo , Proteínas de Transporte de Serotonina en la Membrana Plasmática/farmacología , Obesidad/metabolismo , Termogénesis/fisiología , Enfermedades Metabólicas/metabolismo
4.
JACC Cardiovasc Imaging ; 16(6): 820-832, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36526577

RESUMEN

BACKGROUND: The diagnosis and management of myocardial infarction are increasingly complex, and establishing the presence of intracoronary thrombosis has major implications for both the classification and treatment of myocardial infarction. OBJECTIVES: The aim of this study was to investigate whether positron emission tomographic (PET) and computed tomographic (CT) imaging could noninvasively detect in vivo thrombus formation in human coronary arteries using a novel glycoprotein IIb/IIIa receptor antagonist-based radiotracer, 18F-GP1. METHODS: In a single-center observational case-control study, patients with or without acute myocardial infarction underwent coronary 18F-GP1 PET/CT angiography. Coronary artery 18F-GP1 uptake was assessed visually and quantified using maximum target-to-background ratios. RESULTS: 18F-GP1 PET/CT angiography was performed in 49 patients with and 50 patients without acute myocardial infarction (mean age: 61 ± 9 years, 75% men). Coronary 18F-GP1 uptake was apparent in 39 of the 49 culprit lesions (80%) in patients with acute myocardial infarction. False negative results appeared to relate to time delays to scan performance and low thrombus burden in small-caliber distal arteries. On multivariable regression analysis, culprit vessel status was the only independent variable associated with higher 18F-GP1 uptake. Extracoronary cardiac 18F-GP1 findings included a high frequency of infarct-related intramyocardial uptake (35%) as well as left ventricular (8%) or left atrial (2%) thrombus. CONCLUSIONS: Coronary 18F-GP1 PET/CT angiography is the first noninvasive selective technique to identify in vivo coronary thrombosis in patients with acute myocardial infarction. This novel approach can further define the role and location of thrombosis within the heart and has the potential to inform the diagnosis, management, and treatment of patients with acute myocardial infarction. (In-Vivo Thrombus Imaging With 18F-GP1, a Novel Platelet PET Radiotracer [iThrombus]; NCT03943966).


Asunto(s)
Trombosis Coronaria , Infarto del Miocardio , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Vasos Coronarios/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios de Casos y Controles , Valor Predictivo de las Pruebas , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/terapia , Infarto del Miocardio/patología , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/terapia , Inhibidores de Agregación Plaquetaria , Angiografía Coronaria
5.
Eur Heart J Cardiovasc Imaging ; 23(12): 1698-1707, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-35666823

RESUMEN

AIMS: The influence haemodynamics have on vessel wall pathobiology in aortic disease is incomplete. This aim of this study was to develop a repeatable method for assessing the relationship between aortic wall shear stress (WSS) and disease activity by fusing 4D flow cardiovascular magnetic resonance (CMR) with hybrid positron emission tomography (PET). METHODS AND RESULTS: As part of an ongoing clinical trial, patients with bicuspid aortic valve (BAV) were prospectively imaged with both 18F-sodium fluoride (18F-NaF) PET, a marker of calcification activity, and 4D flow CMR. We developed novel software allowing accurate 3D co-registration and high-resolution comparison of aortic peak systolic WSS and 18F-NaF PET uptake (maximum tissue-to-background ratio). Intra-observer repeatability of both measurements was determined using Bland-Altman plots and intra-class correlation coefficients (ICCs). The relationship between localized WSS and 18F-NaF uptake was analysed using linear mixed-effect models. Twenty-three patients with BAV (median age 50 [44-55] years, 22% female) were included. Intra-observer repeatability for WSS (ICC = 0.92) and 18F-NaF (ICC = 0.91) measurements obtained within 1.4 ± 0.6 cm2 regions of interest was excellent. On multivariable analysis, 18F-NaF PET uptake was independently and negatively associated with WSS as well as diastolic blood pressure (both P < 0.05), adjusted for age. CONCLUSION: Fused assessment of WSS and 18F-NaF PET uptake is feasible and repeatable, demonstrating a clear association between these two factors. This high spatial resolution approach has major potential to advance our understanding of the relationship between vascular haemodynamics and disease activity.


Asunto(s)
Aorta Torácica , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aorta , Aorta Torácica/patología , Válvula Aórtica/patología , Fenómenos Biomecánicos , Velocidad del Flujo Sanguíneo , Estudios Prospectivos
6.
J Nucl Cardiol ; 29(2): 741-749, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33000405

RESUMEN

OBJECTIVES: Cardiac MR is widely used to diagnose cardiac amyloid, but cannot differentiate AL and ATTR subtypes: an important distinction given their differing treatments and prognoses. We used PET/MR imaging to quantify myocardial uptake of 18F-fluoride in ATTR and AL amyloid patients, as well as participants with aortic stenosis and age/sex-matched controls. METHODS: In this prospective multicenter study, patients were recruited in Edinburgh and New York and underwent 18F-fluoride PET/MR imaging. Standardized volumes of interest were drawn in the septum and areas of late gadolinium enhancement to derive myocardial standardized uptake values (SUV) and tissue-to-background ratio (TBRMEAN) after correction for blood pool activity in the right atrium. RESULTS: 53 patients were scanned: 18 with cardiac amyloid (10 ATTR and 8 AL), 13 controls, and 22 with aortic stenosis. No differences in myocardial TBR values were observed between participants scanned in Edinburgh and New York. Mean myocardial TBRMEAN values in ATTR amyloid (1.13 ± 0.16) were higher than controls (0.84 ± 0.11, P = .0006), aortic stenosis (0.73 ± 0.12, P < .0001), and those with AL amyloid (0.96 ± 0.08, P = .01). TBRMEAN values within areas of late gadolinium enhancement provided discrimination between patients with ATTR (1.36 ± 0.23) and all other groups (e.g., AL [1.06 ± 0.07, P = .003]). A TBRMEAN threshold >1.14 in areas of LGE demonstrated 100% sensitivity (CI 72.25 to 100%) and 100% specificity (CI 67.56 to 100%) for ATTR compared to AL amyloid (AUC 1, P = .0004). CONCLUSION: Quantitative 18F-fluoride PET/MR imaging can distinguish ATTR amyloid from other similar phenotypes and holds promise in improving the diagnosis of this condition.


Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Cardiomiopatías , Amiloidosis/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Medios de Contraste , Fluoruros , Gadolinio , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Estudios Prospectivos
7.
J Nucl Cardiol ; 29(3): 1372-1385, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33474695

RESUMEN

BACKGROUND: Standard methods for quantifying positron emission tomography (PET) uptake in the aorta are time consuming and may not reflect overall vessel activity. We describe aortic microcalcification activity (AMA), a novel method for quantifying 18F-sodium fluoride (18F-NaF) uptake in the thoracic aorta. METHODS: Twenty patients underwent two hybrid 18F-NaF PET and computed tomography (CT) scans of the thoracic aorta less than three weeks apart. AMA, as well as maximum (TBRmax) and mean (TBRmean) tissue to background ratios, were calculated by two trained operators. Intra-observer repeatability, inter-observer repeatability and scan-rescan reproducibility were assessed. Each 18F-NaF quantification method was compared to validated cardiovascular risk scores. RESULTS: Aortic microcalcification activity demonstrated excellent intra-observer (intraclass correlation coefficient 0.98) and inter-observer (intraclass correlation coefficient 0.97) repeatability with very good scan-rescan reproducibility (intraclass correlation coefficient 0.86) which were similar to previously described TBRmean and TBRmax methods. AMA analysis was much quicker to perform than standard TBR assessment (3.4min versus 15.1min, P<0.0001). AMA was correlated with Framingham stroke risk scores and Framingham risk score for hard cononary heart disease. CONCLUSIONS: AMA is a simple, rapid and reproducible method of quantifying global 18F-NaF uptake across the ascending aorta and aortic arch that correlates with cardiovascular risk scores.


Asunto(s)
Calcinosis , Radioisótopos de Flúor , Aorta Torácica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , Fluoruro de Sodio
9.
Front Cardiovasc Med ; 8: 653648, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33889599

RESUMEN

Purpose: To explore the utility of phosphorus magnetic resonance spectroscopy (31P MRS) in identifying anthracycline-induced cardiac toxicity in patients with breast cancer. Methods: Twenty patients with newly diagnosed breast cancer receiving anthracycline-based chemotherapy had cardiac magnetic resonance assessment of left ventricular ejection fraction (LVEF) and 31P MRS to determine myocardial Phosphocreatine/Adenosine Triphosphate Ratio (PCr/ATP) at three time points: pre-, mid-, and end-chemotherapy. Plasma high sensitivity cardiac troponin-I (cTn-I) tests and electrocardiograms were also performed at these same time points. Results: Phosphocreatine/Adenosine Triphosphate did not change significantly between pre- and mid-chemo (2.16 ± 0.46 vs. 2.00 ± 0.56, p = 0.80) and pre- and end-chemo (2.16 ± 0.46 vs. 2.17 ± 0.86, p = 0.99). Mean LVEF reduced significantly by 5.1% between pre- and end-chemo (61.4 ± 4.4 vs. 56.3 ± 8.1 %, p = 0.02). Change in PCr/ATP ratios from pre- to end-chemo correlated inversely with changes in LVEF over the same period (r = -0.65, p = 0.006). Plasma cTn-I increased progressively during chemotherapy from pre- to mid-chemo (1.35 ± 0.81 to 4.40 ± 2.64 ng/L; p = 0.01) and from mid- to end-chemo (4.40 ± 2.64 to 18.33 ± 13.23 ng/L; p = 0.001). Conclusions: In this small cohort pilot study, we did not observe a clear change in mean PCr/ATP values during chemotherapy despite evidence of increased plasma cardiac biomarkers and reduced LVEF. Future similar studies should be adequately powered to take account of patient drop-out and variable changes in PCr/ATP and could include T1 and T2 mapping.

10.
Inf Fusion ; 67: 147-160, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33658909

RESUMEN

Cycle-consistent generative adversarial network (CycleGAN) has been widely used for cross-domain medical image synthesis tasks particularly due to its ability to deal with unpaired data. However, most CycleGAN-based synthesis methods cannot achieve good alignment between the synthesized images and data from the source domain, even with additional image alignment losses. This is because the CycleGAN generator network can encode the relative deformations and noises associated to different domains. This can be detrimental for the downstream applications that rely on the synthesized images, such as generating pseudo-CT for PET-MR attenuation correction. In this paper, we present a deformation invariant cycle-consistency model that can filter out these domain-specific deformation. The deformation is globally parameterized by thin-plate-spline (TPS), and locally learned by modified deformable convolutional layers. Robustness to domain-specific deformations has been evaluated through experiments on multi-sequence brain MR data and multi-modality abdominal CT and MR data. Experiment results demonstrated that our method can achieve better alignment between the source and target data while maintaining superior image quality of signal compared to several state-of-the-art CycleGAN-based methods.

11.
J Nucl Cardiol ; 28(5): 1-12, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-31792913

RESUMEN

BACKGROUND: 18F-Fluoride uptake denotes calcification activity in aortic stenosis and atherosclerosis. While PET/MR has several advantages over PET/CT, attenuation correction of PET/MR data is challenging, limiting cardiovascular application. We compared PET/MR and PET/CT assessments of 18F-fluoride uptake in the aortic valve and coronary arteries. METHODS AND RESULTS: 18 patients with aortic stenosis or recent myocardial infarction underwent 18F-fluoride PET/CT followed immediately by PET/MR. Valve and coronary 18F-fluoride uptake were evaluated independently. Both standard (Dixon) and novel radial GRE) MR attenuation correction (AC) maps were validated against PET/CT with results expressed as tissue-to-background ratios (TBRs). Visually, aortic valve 18F-fluoride uptake was similar on PET/CT and PET/MR. TBRMAX values were comparable with radial GRE AC (PET/CT 1.55±0.33 vs. PET/MR 1.58 ± 0.34, P = 0.66; 95% limits of agreement - 27% to + 25%) but performed less well with Dixon AC (1.38 ± 0.44, P = 0.06; bias (-)14%; 95% limits of agreement - 25% to + 53%). In native coronaries, 18F-fluoride uptake was similar on PET/MR to PET/CT regardless of AC approach. PET/MR identified 28/29 plaques identified on PET/CT; however, stents caused artifact on PET/MR making assessment of 18F-fluoride uptake challenging. CONCLUSION: Cardiovascular PET/MR demonstrates good visual and quantitative agreement with PET/CT. However, PET/MR is hampered by stent-related artifacts currently limiting clinical application.


Asunto(s)
Fluorodesoxiglucosa F18/uso terapéutico , Angiografía por Resonancia Magnética/normas , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18/administración & dosificación , Humanos , Angiografía por Resonancia Magnética/métodos , Angiografía por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/estadística & datos numéricos , Radiofármacos/administración & dosificación , Radiofármacos/uso terapéutico
12.
Eur Heart J Cardiovasc Imaging ; 21(6): 673-682, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31408105

RESUMEN

AIMS: Cardiovascular thrombosis is responsible a quarter of deaths annually worldwide. Current imaging methods for cardiovascular thrombosis focus on anatomical identification of thrombus but cannot determine thrombus age or activity. Molecular imaging techniques hold promise for identification and quantification of thrombosis in vivo. Our objective was to assess a novel optical and positron-emitting probe targeting Factor XIIIa (ENC2015) as biomarker of active thrombus formation. METHODS AND RESULTS: Optical and positron-emitting ENC2015 probes were assessed ex vivo using blood drawn from human volunteers and passed through perfusion chambers containing denuded porcine aorta as a model of arterial injury. Specificity of ENC2015 was established with co-infusion of a factor XIIIa inhibitor. In vivo18F-ENC2015 biodistribution, kinetics, radiometabolism, and thrombus binding were characterized in rats. Both Cy5 and fluorine-18 labelled ENC2015 rapidly and specifically bound to thrombi. Thrombus uptake was inhibited by a factor XIIIa inhibitor. 18F-ENC2015 remained unmetabolized over 8 h when incubated in ex vivo human blood. In vivo, 42% of parent radiotracer remained in blood 60 min post-administration. Biodistribution studies demonstrated rapid clearance from tissues with elimination via the urinary system. In vivo,18F-ENC2015 uptake was markedly increased in the thrombosed carotid artery compared to the contralateral patent artery (mean standard uptake value ratio of 2.40 vs. 0.74, P < 0.0001). CONCLUSION: ENC2015 rapidly and selectively binds to acute thrombus in both an ex vivo human translational model and an in vivo rodent model of arterial thrombosis. This probe holds promise for the non-invasive identification of thrombus formation in cardiovascular disease.


Asunto(s)
Factor XIIIa , Trombosis , Animales , Fibrina/metabolismo , Imagen Molecular , Ratas , Porcinos , Trombosis/diagnóstico por imagen , Distribución Tisular
13.
Biomed Res Int ; 2017: 9281450, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28698881

RESUMEN

A significant unmet need exists for accurate, reproducible, noninvasive diagnostic tools to assess and monitor portal hypertension (PHT). We report the first use of quantitative MRI markers for the haemodynamic assessment of nonselective beta-blockers (NSBB) in PHT. In a randomized parallel feasibility study in 22 adult patients with PHT and a clinical indication for NSBB, we acquired haemodynamic data at baseline and after 4 weeks of NSBB (propranolol or carvedilol) using phase-contrast MR angiography (PC-MRA) in selected intra-abdominal vessels. T1 mapping of liver and spleen was undertaken to assess changes in tissue composition. Target NSBB dose was achieved in 82%. There was a substantial reduction from baseline in mean average flow in the superior abdominal aorta after 4 weeks of NSBB therapy (4.49 ± 0.98 versus 3.82 ± 0.86 L/min, P = 0.03) but there were no statistically significant differences in flow in any other vessels, even in patients with >25% decrease in heart rate (47% of patients). Mean percentage change in liver and spleen T1 following NSBB was small and highly variable. In conclusion, PC-MRA was able to detect reduction in cardiac output by NSBB but did not detect significant changes in visceral blood flow or T1. This trial was registered with the ISRCTN registry (ISRCTN98001632).


Asunto(s)
Antagonistas Adrenérgicos beta/administración & dosificación , Aorta Abdominal , Carbazoles/administración & dosificación , Medios de Contraste/administración & dosificación , Hemodinámica/efectos de los fármacos , Hipertensión Portal , Angiografía por Resonancia Magnética , Propanolaminas/administración & dosificación , Propranolol/administración & dosificación , Anciano , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Carvedilol , Femenino , Humanos , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/tratamiento farmacológico , Hipertensión Portal/fisiopatología , Masculino , Persona de Mediana Edad
14.
Biomed Res Int ; 2017: 3956363, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28251155

RESUMEN

Fetal brain magnetic resonance imaging (MRI) is a rapidly emerging diagnostic imaging tool. However, automated fetal brain localization is one of the biggest obstacles in expediting and fully automating large-scale fetal MRI processing. We propose a method for automatic localization of fetal brain in 3 T MRI when the images are acquired as a stack of 2D slices that are misaligned due to fetal motion. First, the Histogram of Oriented Gradients (HOG) feature descriptor is extended from 2D to 3D images. Then, a sliding window is used to assign a score to all possible windows in an image, depending on the likelihood of it containing a brain, and the window with the highest score is selected. In our evaluation experiments using a leave-one-out cross-validation strategy, we achieved 96% of complete brain localization using a database of 104 MRI scans at gestational ages between 34 and 38 weeks. We carried out comparisons against template matching and random forest based regression methods and the proposed method showed superior performance. We also showed the application of the proposed method in the optimization of fetal motion correction and how it is essential for the reconstruction process. The method is robust and does not rely on any prior knowledge of fetal brain development.


Asunto(s)
Algoritmos , Encéfalo/embriología , Feto/anatomía & histología , Imagen por Resonancia Magnética/métodos , Automatización , Bases de Datos como Asunto , Femenino , Edad Gestacional , Humanos , Movimiento (Física)
15.
Front Neuroinform ; 11: 2, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28163680

RESUMEN

Quantitative volumes from brain magnetic resonance imaging (MRI) acquired across the life course may be useful for investigating long term effects of risk and resilience factors for brain development and healthy aging, and for understanding early life determinants of adult brain structure. Therefore, there is an increasing need for automated segmentation tools that can be applied to images acquired at different life stages. We developed an automatic segmentation method for human brain MRI, where a sliding window approach and a multi-class random forest classifier were applied to high-dimensional feature vectors for accurate segmentation. The method performed well on brain MRI data acquired from 179 individuals, analyzed in three age groups: newborns (38-42 weeks gestational age), children and adolescents (4-17 years) and adults (35-71 years). As the method can learn from partially labeled datasets, it can be used to segment large-scale datasets efficiently. It could also be applied to different populations and imaging modalities across the life course.

16.
Front Neurosci ; 10: 220, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27242423

RESUMEN

Neuroimage analysis pipelines rely on parcellated atlases generated from healthy individuals to provide anatomic context to structural and diffusion MRI data. Atlases constructed using adult data introduce bias into studies of early brain development. We aimed to create a neonatal brain atlas of healthy subjects that can be applied to multi-modal MRI data. Structural and diffusion 3T MRI scans were acquired soon after birth from 33 typically developing neonates born at term (mean postmenstrual age at birth 39(+5) weeks, range 37(+2)-41(+6)). An adult brain atlas (SRI24/TZO) was propagated to the neonatal data using temporal registration via childhood templates with dense temporal samples (NIH Pediatric Database), with the final atlas (Edinburgh Neonatal Atlas, ENA33) constructed using the Symmetric Group Normalization (SyGN) method. After this step, the computed final transformations were applied to T2-weighted data, and fractional anisotropy, mean diffusivity, and tissue segmentations to provide a multi-modal atlas with 107 anatomical regions; a symmetric version was also created to facilitate studies of laterality. Volumes of each region of interest were measured to provide reference data from normal subjects. Because this atlas is generated from step-wise propagation of adult labels through intermediate time points in childhood, it may serve as a useful starting point for modeling brain growth during development.

17.
Sci Rep ; 6: 23470, 2016 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-27010238

RESUMEN

Accurate whole-brain segmentation, or brain extraction, of magnetic resonance imaging (MRI) is a critical first step in most neuroimage analysis pipelines. The majority of brain extraction algorithms have been developed and evaluated for adult data and their validity for neonatal brain extraction, which presents age-specific challenges for this task, has not been established. We developed a novel method for brain extraction of multi-modal neonatal brain MR images, named ALFA (Accurate Learning with Few Atlases). The method uses a new sparsity-based atlas selection strategy that requires a very limited number of atlases 'uniformly' distributed in the low-dimensional data space, combined with a machine learning based label fusion technique. The performance of the method for brain extraction from multi-modal data of 50 newborns is evaluated and compared with results obtained using eleven publicly available brain extraction methods. ALFA outperformed the eleven compared methods providing robust and accurate brain extraction results across different modalities. As ALFA can learn from partially labelled datasets, it can be used to segment large-scale datasets efficiently. ALFA could also be applied to other imaging modalities and other stages across the life course.


Asunto(s)
Atlas como Asunto , Encéfalo/fisiología , Aprendizaje , Humanos , Recién Nacido , Imagen por Resonancia Magnética
18.
Cardiovasc Intervent Radiol ; 39(3): 376-84, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26183465

RESUMEN

PURPOSE: Absence of contrast on contrast enhanced MRI (CEMRI) and reduction in uterine volume at 6 months post-uterine artery embolisation (UAE) currently indicate the successful disruption of the fibroid blood supply by UAE. This study assesses whether (1)H MR spectroscopy ((1)H MRS) can also indicate the success of UAE. METHOD: 20 patients with symptomatic fibroids were randomised 1:1 to undergo UAE with either Gelfoam or Embospheres. CEMRI and spectra (1.5 T) were acquired pre-, 24-h and 6 months post-UAE. LCModel was used to detect significant levels of choline, creatine and lactate in fibroid spectra. Uterine volumes were measured and paired t tests (p < 0.05) assessed volume reduction over time. Qualitative assessments of CEMRI were performed. RESULTS: Choline was detected in 17/18 spectra pre-UAE, 12/14 at 24-h and 6/16 at 6 months post-UAE. Choline was not detected in the 7/7 spectra available for the Embospheres group at 6 months. These fibroids were non-enhancing on CEMRI and associated with a significant reduction in mean uterine volume at 6 months (mean/min/max 396.5/84.1/997.5 cm(3), p = 0.003). Choline was detected in 6/9 fibroid spectra available for the Gelfoam group at 6 months. Of these fibroids, four demonstrated persistent enhancement on CEMRI and two were non-enhancing. This group did not demonstrate significant uterine volume reduction (mean/min/max 117.2/-230.6/382.6 cm(3), p = 0.15). The negative minimum value indicates fibroid growth. CONCLUSIONS: This study has demonstrated the potential of (1)H MRS to provide an additional marker of the success of UAE.


Asunto(s)
Leiomioma/terapia , Espectroscopía de Resonancia Magnética , Embolización de la Arteria Uterina/métodos , Neoplasias Uterinas/terapia , Útero/irrigación sanguínea , Resinas Acrílicas/administración & dosificación , Femenino , Gelatina/administración & dosificación , Esponja de Gelatina Absorbible/administración & dosificación , Humanos , Leiomioma/diagnóstico por imagen , Leiomioma/patología , Imagen por Resonancia Magnética , Tamaño de los Órganos , Proyectos Piloto , Resultado del Tratamiento , Neoplasias Uterinas/diagnóstico por imagen , Neoplasias Uterinas/patología , Útero/diagnóstico por imagen , Útero/patología
19.
NMR Biomed ; 28(10): 1275-82, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26313636

RESUMEN

The placenta is a temporary organ that is essential for a healthy pregnancy. It performs several important functions, including the transport of nutrients, the removal of waste products and the metabolism of certain substances. Placental disorders have been found to account for over 50% of stillbirths. Despite this, there are currently no methods available to directly and non-invasively assess placental function in utero. The primary aim of this pilot study was to investigate the use of (1)H MRS for this purpose. (1)H MRS offers the possibility to detect several placental metabolites, including choline, lipids and the amino acids glutamine and glutamate (Glx), which are vital to fetal development and placental function. Here, in utero placental spectra were acquired from nine small for gestational age (SGA) pregnancies, a cohort who are at increased risk of perinatal morbidity and mortality, and from nine healthy gestation-matched pregnancies. All subjects were between 26 and 39 weeks of gestation. Placenta Glx, choline and lipids at 1.3 and 0.9 ppm were quantified as amplitude ratios to that of intrinsic H2O. Wilcoxon signed rank tests indicated a significant difference in Glx/H2O (p = 0.024) between the two groups, but not in choline/H2O (p = 0.722) or in either lipid/H2O ratio (1.3 ppm, p = 0.813; 0.9 ppm, p = 0.058). This study has demonstrated that (1)H MRS has potential for the detection of placental metabolites in utero. This warrants further investigation as a tool for the monitoring of placental function.


Asunto(s)
Retardo del Crecimiento Fetal/fisiopatología , Placenta/fisiología , Espectroscopía de Protones por Resonancia Magnética , Adulto , Algoritmos , Aminoácidos/análisis , Índice de Masa Corporal , Colina/análisis , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Retardo del Crecimiento Fetal/metabolismo , Gastrosquisis/mortalidad , Gastrosquisis/cirugía , Edad Gestacional , Humanos , Recién Nacido , Recién Nacido Pequeño para la Edad Gestacional , Lípidos/análisis , Método de Montecarlo , Proyectos Piloto , Placenta/química , Embarazo , Resultado del Embarazo , Atención Prenatal/métodos , Estudios Prospectivos , Factores Socioeconómicos , Mortinato , Ultrasonografía , Adulto Joven
20.
Nephrol Dial Transplant ; 27(6): 2446-51, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22241795

RESUMEN

BACKGROUND: Premature sudden cardiovascular death is the commonest cause of death in end-stage renal disease (ESRD) patients and is associated with uraemic cardiomyopathy [left ventricular hypertrophy (LVH), systolic dysfunction (LVSD) or LV dilation]. High-energy phosphates (HEP), quantified using phosphorus-31 magnetic resonance spectroscopy, are reduced in patients with diabetes, heart failure and uraemia. Phosphocreatine:ß adenosine triphosphate (PCr:ATP) ratio is an index of metabolic activity. We compared resting HEPs in ESRD patients and hypertensive patients (with and without LVH) who had normal renal function (LVH-only or normal myocardia). We also assessed associations of HEP levels with abnormalities of uraemic cardiomyopathy. METHODS: Fifty-three ESRD and 30 hypertensive patients (18 with LVH, 12 with normal myocardia) underwent phosphorus magnetic resonance spectroscopy of their left ventricle. PCr:ATP ratios were calculated from (31)P-MR spectra obtained from long-axis views of the left ventricle. RESULTS: There were no significant differences in age, LV mass, chamber sizes and ejection fraction between patient groups. PCr:ATP was significantly lower in ESRD patients compared to hypertensive patients, irrespective of the presence or absence of LVH (P = 0.01). In the ESRD group, PCr:ATP was significantly lower in patients with LVSD (P = 0.05) and LV dilation (P = 0.01). LVH was not associated with significant difference in PCr:ATP. CONCLUSIONS: ESRD patients have lower HEP levels compared to hypertensive patients. Lower PCr:ATP ratio, indicating altered myocardial metabolic function in ESRD patients, is associated with features of uraemic cardiomyopathy.


Asunto(s)
Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Fallo Renal Crónico/complicaciones , Espectroscopía de Resonancia Magnética , Fosfatos/análisis , Uremia/complicaciones , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/complicaciones , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/etiología , Masculino , Persona de Mediana Edad , Isótopos de Fósforo/metabolismo , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...