Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
2.
Transpl Int ; 36: 11675, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37727385

RESUMEN

Despite the withdrawal of the HeartWare Ventricular Assist Device (HVAD), hundreds of patients are still supported with this continuous-flow pump, and the long-term management of these patients is still under debate. This study aims to analyse 5 years survival and freedom from major adverse events in patients supported by HVAD and HeartMate3 (HM3). From 2010 to 2022, the MIRAMACS Italian Registry enrolled all-comer patients receiving a LVAD support at seven Cardiac Surgery Centres. Out of 447 LVAD implantation, 214 (47.9%) received HM3 and 233 (52.1%) received HVAD. Cox-regression analysis adjusted for major confounders showed an increased risk for mortality (HR 1.5 [1.2-1.9]; p = 0.031), for both ischemic stroke (HR 2.08 [1.06-4.08]; p = 0.033) and haemorrhagic stroke (HR 2.6 [1.3-4.9]; p = 0.005), and for pump thrombosis (HR 25.7 [3.5-188.9]; p < 0.001) in HVAD patients. The propensity-score matching analysis (130 pairs of HVAD vs. HM3) confirmed a significantly lower 5 years survival (81.25% vs. 64.1%; p 0.02), freedom from haemorrhagic stroke (90.5% vs. 70.1%; p < 0.001) and from pump thrombosis (98.5% vs. 74.7%; p < 0.001) in HVAD cohort. Although similar perioperative outcome, patients implanted with HVAD developed a higher risk for mortality, haemorrhagic stroke and thrombosis during 5 years of follow-up compared to HM3 patients.


Asunto(s)
Corazón Auxiliar , Accidente Cerebrovascular Hemorrágico , Humanos , Sistema de Registros , Puntaje de Propensión , Fenómenos Magnéticos
3.
Clin Transplant ; 37(5): e14950, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36823475

RESUMEN

INTRODUCTION: Heart transplant (HTx) recipients require continuous monitoring and care in order to prevent and treat possible complications related to the graft function or to the immunosuppressive treatment promptly. Since heart transplantation centers (HTC) are more experienced in managing HTx recipients than other healthcare facilities, the distance between patient residency and HTC could negatively affect the outcomes. METHODS: Data of patients discharged after receiving HTx between 2000 and 2021, collected into our institutional database, were retrospectively analyzed. The population was divided into three groups: A (n = 180), B (n = 157), and C (n = 134), according to the distance tertiles between patient residency and HTC. The primary end-point was survival, secondary end-points were incidences of complications. RESULTS: Recipient and donor characteristics did not differ between the three groups. Survival at 10 years was 66 ± 4%, 66 ± 4%, and 65 ± 5%, respectively, for groups A, B, and C (p = .34). Immunosuppressive regimen and rate of complications did not differ between groups. However, the rates of outpatient visits and of hospitalization performed at HTC were higher in group A than others. CONCLUSION: Distance from the HTC does not represent a barrier to a successful outcome for HTx recipients, as long as regular and continuous follow-up is provided.


Asunto(s)
Trasplante de Corazón , Internado y Residencia , Humanos , Estudios Retrospectivos , Bases de Datos Factuales , Trasplante de Corazón/efectos adversos , Hospitalización , Inmunosupresores
4.
Artif Organs ; 46(12): 2486-2492, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35866429

RESUMEN

BACKGROUND: We investigated the synergistic effect of the new cone-bearing design of Jarvik 2000 (Jarvik Heart Inc., NY) together with a minimally-invasive approach to outcomes of LVAD patients. METHODS: We retrospectively reviewed all patients from 5 institutions involved in the Jarvik 2000 Italian Registry, from October 2008 to October 2016. Patients were divided into three groups according to pump design and implantation technique: pin-bearing design and conventional approach (Group 1); cone-bearing and conventional approach (Group 2); cone-bearing and minimally-invasive implantation (Group 3). RESULTS: A total of 150 adult patients with end-stage heart failure were enrolled: 26 subjects in Group 1, 74 in Group 2, and 50 in Group 3. Nineteen patients (73%) in Group 1, 51 (69%) in Group 2, and 36 (72%) in Group 3 were discharged. During follow-up, 22 patients underwent transplantation, while in 3 patients the LVAD was explanted. The overall 1-year survival was 58 ± 10%, 64 ± 6%, and 74% ± 7% in Groups 1, 2, and 3, respectively (p = 0.034). The competing-risks-adjusted cumulative incidence rate for adverse events was 42.1 [27-62.7] per 100 patient-years in Group 1, 35.4 [25.3-48.2] in Group 2, and 22.1 [12.4-36.4] in Group 3 (p = 0.046 for Group 1 vs. 3). CONCLUSIONS: The association of the modern cone-bearing configuration of Jarvik 2000 and minimally invasive surgery improved survival and minimized the risk for cardiovascular events, as a result of combining technology and technique.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Adulto , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Tecnología , Resultado del Tratamiento
5.
Artif Organs ; 46(11): 2319-2324, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35802767

RESUMEN

Left ventricular assist device (LVAD) has emerged as an effective surgical therapy for end-stage heart failure. In an attempt to reduce invasiveness and avoid difficult sternal re-entries, alternative surgical approaches have been adopted. In particular, when the thoracic aorta is severely diseased or difficult to expose, subclavian arteries could serve as site for outflow graft anastomosis. However, major concerns regarding the utilization of subclavian arteries are the small caliber of these vessels that could lead to inadequate LVAD flow, arm complications related to excessive blood flow, and possible outflow graft compression. In the present case series, we describe an innovative technique for LVAD implantation, in which the left subclavian artery was employed as an outflow graft anastomosis site, and the left ventricular apex was approached through a mini-thoracotomy. Technical issues were considered to prevent possible complications: the adequacy of left subclavian artery diameter, the banding of the artery distal to the anastomosis site to limit left arm overflow, and the outflow graft covering with a reinforced vascular graft to avoid any external compression. During follow-up, the technique reported was found to be effective in ensuring good LVAD function and flow, and no complications related to the procedure were reported.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Arteria Subclavia/cirugía , Aorta Torácica/cirugía , Ventrículos Cardíacos/cirugía , Hemodinámica , Insuficiencia Cardíaca/cirugía
6.
Artif Organs ; 46(9): 1932-1936, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35718933

RESUMEN

BACKGROUND: Patients with LVAD require continuous monitoring and care, and since Implanting Centers (ICs) are more experienced in managing LVAD patients than other healthcare facilities, the distance between patient residency and IC could negatively affect the outcomes. METHODS: Data of patients discharged after receiving an LVAD implantation between 2010 and 2021 collected from the MIRAMACS database were retrospectively analyzed. The population was divided into two groups: A (n = 175) and B (n = 141), according to the distance between patient residency and IC ≤ or >90 miles. The primary endpoint was freedom from Adverse Events (AEs), a composite outcome composed of death, cerebrovascular accident, hospital admission because of GI bleeding, infection, pump thrombosis, and right ventricular failure. Secondary endpoints were incidences of mortality and complications. All patients were followed-up regularly, according to participating center protocols. RESULTS: Baseline clinical characteristics and indications for LVAD did not differ between the two groups. The mean duration of support was 25.5 ± 21 months for Group A and 25.7 ± 20 months for Group B (p = 0.79). At 3 years, freedom from AEs was similar between Group A and Group B (p = 0.36), and there were no differences in rates of mortality and LVAD-related complications. CONCLUSIONS: Distance from the IC does not represent a barrier to successful outcomes as long as regular and continuous follow-up is provided.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Internado y Residencia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
7.
J Cardiovasc Med (Hagerstown) ; 22(5): 388-395, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32858640

RESUMEN

AIMS: We aimed to describe how treatment of patients in cardiogenic shock bridged to heart transplantation with mechanical circulatory support, using either biventricular assist devices (BVADs) or extracorporeal life support (ECLS), has evolved in the last 20 years in our centre. METHODS: Since 1998, 72 patients with refractory heart failure and indication for heart transplantation have received mechanical circulatory support: 40 had an ECLS system and 32 a BVAD. RESULTS: Early mortality was similar (17.5 vs. 9.4%, P = 0.25) regardless of the type of support. After a median support time of 8 (1-27) vs. 34 (0-385) days (P < 0.01), 70 vs. 65.6% (P = 0.69) of patients underwent transplantation in the two groups. Prior to transplantation, BVAD patients were more stable with lower need for mechanical ventilation (9 vs. 57%, P < 0.01) and dialysis (0 vs. 38%, P < 0.01). Thirty-day mortality after transplantation was similar (18 vs. 14%, P = 0.53). Patients with extracorporeal support had higher rates of renal (P = 0.02) and respiratory failure (P = 0.03), infections (P = 0.02), atrial fibrillation (P = 0.03) and longer ICU stay (P = 0.01). Late survival was similar, while 5-year freedom from coronary vasculopathy was higher in those with BVAD (P = 0.03). CONCLUSION: Although ECLS provides faster and simpler assistance compared with BVADs, no differences in early and medium-term outcomes in the last 20 years were observed in patients with cardiogenic shock. However, BVADs provided longer duration of support, better multiorgan recovery allowing more adequate graft selection, resulting in a lower rate of posttransplant complications.


Asunto(s)
Circulación Asistida , Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar/estadística & datos numéricos , Complicaciones Posoperatorias/prevención & control , Choque Cardiogénico , Circulación Asistida/instrumentación , Circulación Asistida/métodos , Circulación Asistida/estadística & datos numéricos , Duración de la Terapia , Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/métodos , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Recuperación de la Función , Choque Cardiogénico/complicaciones , Choque Cardiogénico/terapia
8.
Artif Organs ; 45(3): 236-243, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32860268

RESUMEN

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Aorta/fisiopatología , Aorta/cirugía , Creatinina/sangre , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Hemólisis/fisiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Resultado del Tratamiento
9.
Interact Cardiovasc Thorac Surg ; 32(3): 476-482, 2021 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-33221874

RESUMEN

OBJECTIVES: Patients with mechanical circulatory support bridged to a heart transplant (HTx) are at higher risk of postoperative graft dysfunction. In this subset, a mode of graft preservation that shortens graft ischaemia should be beneficial. METHODS: The outcomes of 38 patients on mechanical circulatory support (extracorporeal life support, left ventricular assist device and biventricular assist device) who received a HTx between 2015 and 2020 were analysed according to the method of graft preservation: cold storage (CS) group, 24 (63%) or ex vivo perfusion (EVP) group, 14 (37%). RESULTS: The median age was 57 (range 30-73) vs 64 (35-75) years (P = 0.10); 88% were men (P = 0.28); extracorporeal life support was more frequent in the CS group (54% vs 36%; P = 0.27) versus left ventricular and biventricular assist devices in the EVP group (46% vs 64%; P = 0.27). Clamping time was shorter in the EVP group (P < 0.001) and ischaemic time >4 h was higher in the CS group (P = 0.01). Thirty-day mortality was 13% (0-27%) in the CS group and 0% (P = 0.28) in the EVP group. A significantly lower primary graft failure [7% (0-23%) vs 42% (20-63%); P = 0.03] was observed in the EVP group. Survival at 1 year was 79 ± 8% (63-95%) in the CS group and 84 ± 10% (64-104%) in the EVP group (P = 0.95). CONCLUSIONS: Our results support the use of ex vivo graft perfusion in patients on mechanical circulatory support as a bridge to a HTx. This technique, by shortening graft ischaemic time, seems to improve post-HTx outcomes.


Asunto(s)
Criopreservación/métodos , Oxigenación por Membrana Extracorpórea/métodos , Trasplante de Corazón/métodos , Preservación de Órganos/métodos , Perfusión/métodos , Adulto , Anciano , Circulación Extracorporea/métodos , Circulación Extracorporea/tendencias , Oxigenación por Membrana Extracorpórea/tendencias , Femenino , Estudios de Seguimiento , Trasplante de Corazón/tendencias , Corazón Auxiliar/tendencias , Humanos , Masculino , Persona de Mediana Edad , Preservación de Órganos/tendencias , Perfusión/tendencias , Estudios Retrospectivos , Resultado del Tratamiento
10.
Artif Organs ; 42(6): 670-673, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29392738

RESUMEN

Bridge to heart transplantation (HTx) with ECMO is associated with poor outcome, but patient status, according to different levels of multiorgan compromise, is generally not considered. The aim of this study was to analyze the prognostic value of acute physiology, age, and chronic health evaluation IV (APACHE IV) score in this setting. Thirty-two patients underwent HTx bridged with ECMO at our institution between 2005 and 2017; they were divided into two groups, according to a cutoff value of APACHE IV score obtained by Receiver operating characteristic curve analysis for 30-day mortality. Kaplan-Meyer survival curves were plotted, and compared through the log-Rank test. Cox regression model was used to estimate which factors were associated with overall survival. The 30-day mortality prediction of the APACHE IV score showed an AUC of 0.98 [95% C.I. 0.84-0.99], with a cutoff value corresponding to a score value of 47 (specificity of 84.6% and sensitivity of 100%) in order to discriminate between a group with low probability (Group A, patients with an APACHE IV score <47), and a group with high probability (Group B, patients with an APACHE IV score ≥47) of 30-day mortality. Median follow up was 26.9 months (range: 0.03-143.8). On overall, patients bridged with ECMO showed a high early mortality (18.7% <30 days, n = 6). All deaths occurred in Group B, where 30-day mortality was 60%. Survival probability among Group B patients was 26.6% at both 1 and 5 years. Conversely, in Group A no early mortality was reported, and the estimated survival was 89.7% at 1 year and 81.5% at 5 years, respectively. Mortality correlated at univariate analysis with recipient age, APACHE IV score and female sex, while the multivariate Cox regression analysis showed that only an APACHE IV score (HR 1.23 [1.08-1.39, 95% C.I.]) and female sex (HR 6.68 [1.42-31.43, 95% C.I.]) had an adverse impact on survival. This study shows that the APACHE IV score could be considered a powerful predictor of survival in patients bridged by ECMO to HTx, and can account for a better selection of patients on ECMO support at time of listing.


Asunto(s)
APACHE , Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Adulto , Factores de Edad , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Estudios de Seguimiento , Trasplante de Corazón/métodos , Trasplante de Corazón/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Curva ROC , Factores de Riesgo
11.
Infection ; 46(2): 263-265, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29086895

RESUMEN

BACKGROUND: Ceftolozane/tazobactam (C/T) is a novel antibiotic with enhanced microbiological activity against multidrug-resistant (MDR) gram-negative bacteria, including MDR Pseudomonas aeruginosa. CASE REPORT: Five months after left ventricular assist device (LVAD) implantation, a 49-year old man developed fever and blood culture was positive for MDR P. aeruginosa, susceptible only to aminoglycosides, ciprofloxacin and colistin. A diagnosis of LVAD-related infection was made based on persistent bacteremia associated with moderate 18 F-fluorodeoxyglucose positron emission tomography/CT uptake in the left ventricular apex. Disk diffusion testing for C/T was performed (MIC 2 µg/mL) and intravenous antibiotic therapy with C/T and amikacin was started, with clinical and microbiological response. Initial conservative management with 6 weeks of systemic antibiotic therapy was attempted, but the patient relapsed one month after antibiotic discontinuation. Priority for transplantation was given and after 4 weeks of antibiotic therapy (C/T + amikacin), LVAD removal and heart transplant were performed, with no infection relapse. CONCLUSIONS: We reported the first off-label use of C/T in the management of MDR P. aeruginosa LVAD infection as a bridge to heart transplant. C/T has shown potent anti-pseudomonal activity and good safety profile making this drug as a good candidate for suppressive strategy in intravascular device-associated bloodstream infections caused by MDR P. aeruginosa.


Asunto(s)
Antibacterianos , Cefalosporinas , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Ácido Penicilánico/análogos & derivados , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones por Pseudomonas/tratamiento farmacológico , Pseudomonas aeruginosa/efectos de los fármacos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Cefalosporinas/farmacología , Cefalosporinas/uso terapéutico , Farmacorresistencia Bacteriana Múltiple , Corazón Auxiliar/microbiología , Humanos , Masculino , Persona de Mediana Edad , Ácido Penicilánico/farmacología , Ácido Penicilánico/uso terapéutico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones por Pseudomonas/microbiología , Tazobactam
12.
Europace ; 20(2): 234-242, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28521022

RESUMEN

Pharmacologic challenge with sodium channel blockers is part of the diagnostic workout in patients with suspected Brugada syndrome. The test is overall considered safe but both ajmaline and flecainide detain well known pro-arrhythmic properties. Moreover, the treatment of patients with life-threatening arrhythmias during these diagnostic procedures is not well defined. Current consensus guidelines suggest to adopt cautious protocols interrupting the sodium channel blockers as soon as any ECG alteration appears. Nevertheless, the risk of life-threatening arrhythmias persists, even adopting a safe and cautious protocol and in absence of major arrhythmic risk factors. The authors revise the main published case studies of sodium channel blockers challenge in adults and in children, and summarize three cases of untreatable ventricular arrhythmias discussing their management. In particular, the role of advanced cardiopulmonary resuscitation with extra-corporeal membrane oxygenation is stressed as it can reveal to be the only reliable lifesaving facility in prolonged cardiac arrest.


Asunto(s)
Síndrome de Brugada/diagnóstico , Reanimación Cardiopulmonar , Electrocardiografía , Oxigenación por Membrana Extracorpórea , Sistema de Conducción Cardíaco/efectos de los fármacos , Bloqueadores de los Canales de Sodio/efectos adversos , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Potenciales de Acción/efectos de los fármacos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ajmalina/administración & dosificación , Ajmalina/efectos adversos , Síndrome de Brugada/fisiopatología , Niño , Femenino , Flecainida/administración & dosificación , Flecainida/efectos adversos , Paro Cardíaco/fisiopatología , Paro Cardíaco/terapia , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Riesgo , Bloqueadores de los Canales de Sodio/administración & dosificación , Taquicardia Ventricular/inducido químicamente , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Fibrilación Ventricular/inducido químicamente , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Adulto Joven
13.
J Thorac Cardiovasc Surg ; 151(1): 213-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26548997

RESUMEN

OBJECTIVE: In vitro tests demonstrated that the new cone-bearing configuration of the Jarvik 2000 (Jarvik Heart Inc, New York, NY) left ventricular assist device exhibits better hydraulic efficiency than the previous pin-bearing design. We investigated the long-term outcomes of patients who received the Jarvik 2000 left ventricular assist device, depending on bearing design. METHODS: A retrospective review of prospectively collected data from 18 centers included in the Italian Registry was performed. From May 2008 to September 2013, 99 patients with end-stage heart failure were enrolled. Patients were divided into 2 groups according to their Jarvik 2000 suspending mechanism: Group pin included patients with pin bearings (May 2008 to June 2010), and group cone included patients with newer cone bearings (July 2010 to September 2013). The 2 groups did not differ significantly in terms of baseline characteristics. RESULTS: A total of 30 of 39 patients (group pin) and 46 of 60 patients (group cone) were discharged. During follow-up, 6 patients underwent transplantation, and in 1 patient the left ventricular assist device was explanted. The cumulative incidence competing risk of the entire cohort for noncardiovascular-related death was 28% (20%-40%); the cumulative incidence competing risk for cardiovascular-related death was 56% (42%-73%): 71% in group pin versus 26% in group cone (P = .034). The multivariate analyses confirmed that the pin-bearing design was a risk factor for cardiovascular death, along with Interagency Registry for Mechanically Assisted Circulatory Support class. Right ventricular failures and ischemic and hemorrhagic strokes were significantly higher in group pin. CONCLUSIONS: Patients with the new pump configuration showed a better freedom from cardiovascular death and lower incidence of fatal stroke and right ventricular failure. Further studies are needed to prove the favorable impact of pump-enhanced fluid dynamics on long-term results.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Función Ventricular Izquierda , Anciano , Isquemia Encefálica/epidemiología , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Mortalidad Hospitalaria , Humanos , Incidencia , Hemorragias Intracraneales/epidemiología , Italia/epidemiología , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Derecha/epidemiología
14.
Int J Artif Organs ; 38(10): 542-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26541278

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) implantation improves survival and quality of life in patients with advanced heart failure (HF). Despite these advantages, LVADs are not free from risks. Among all adverse events (AE), pump thrombosis and bleeding, especially of the gastrointestinal (GI) tract, have been reported to occur with increasing frequency in some CF-LVADs. The INCOR LVAD system is a third-generation, continuous flow, axial pump with active magnetic levitation, avoiding the potential downsides of mechanical bearings. METHODS: The aim of this retrospective study was to review the Italian clinical experience with the INCOR LVAD and to determine the prevalence of GI bleeding and pump thrombosis. All patients implanted between January 2006 and May 2012 were considered eligible. RESULTS: The total population consisted of 42 patients. LVAD indication was BTT in 36 (86%) and DT in 6 (14%) patients; 31 patients (74%) were INTERMACS class 1 or 2. Mean support time was 525 ± 570 days. The 1-year and 2-year survival rates were 74% and 60%, respectively. The most frequent AE was driveline infection (0.33 events PPY) followed by stroke with consequence (0.17 events PPY), sepsis (0.07 events PPY), and right HF (0.05 events PPY). No episodes of pump thrombosis or GI bleeding were observed. CONCLUSIONS: In this cohort of high-risk, advanced HF patients, the INCOR LVAD provided effective support with improved survival. Moreover, the absence of GI bleeding and pump thrombosis demonstrates a favorable characteristic of this device. Further prospective studies are needed to confirm these data.


Asunto(s)
Hemorragia Gastrointestinal/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Trombosis/epidemiología , Adulto , Anciano , Femenino , Estudios de Seguimiento , Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Trombosis/etiología , Resultado del Tratamiento
15.
Eur J Heart Fail ; 11(7): 721-7, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19468019

RESUMEN

We report the use of extra-corporeal cardiopulmonary support (ECLS), in a case of complicating refractory severe cardiogenic shock, in a patient with Tako-tsubo cardiomyopathy (TC). Tako-tsubo cardiomyopathy syndrome is characterized by left ventricular (LV) wall motion abnormalities, usually without coronary artery disease, mimicking the diagnosis of acute coronary syndrome. This ventricular dysfunction is typically reversible in the acute phase, though it can progress into refractory cardiogenic shock with limited therapeutic options available. Here, we report for the first time in a Tako-tsubo patient with refractory cardiogenic shock, the use of ECLS treatment in order to unload the heart, sustain circulation and end-organ perfusion, and promote potential ventricular recovery. Extra-corporeal life support allowed inotropic drug weaning while maintaining end-organ function and supported the patient until myocardial recovery. The patient recovered completely, and a normal LV ejection fraction was documented by 2D echocardiography on day 7. From our experience, ECLS can be an appropriate treatment for severe refractory cardiogenic shock in patients with TC. Extra-corporeal life support was an effective ultimate solution.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque Cardiogénico/terapia , Cardiomiopatía de Takotsubo/terapia , Obstrucción del Flujo Ventricular Externo/terapia , Anciano , Femenino , Hemodinámica , Humanos , Recuperación de la Función , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Volumen Sistólico , Cardiomiopatía de Takotsubo/complicaciones , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo/complicaciones
17.
J Cell Mol Med ; 13(9B): 3437-48, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18798866

RESUMEN

Although the myocardium contains progenitor cells potentially capable of regenerating tissue upon lethal ischaemic injury, their actual role in post-infarction heart healing is negligible. Therefore, transplantation of extra-cardiac stem cells is a promising therapeutic approach for post-infarction heart dysfunction. Paracrine cardiotropic factors released by the grafted cells, such as the cardiotropic hormone relaxin (RLX), may beneficially influence remodelling of recipient hearts. The current study was designed to address whether grafting of mouse C2C12 myoblasts, genetically engineered to express green fluorescent protein (C2C12/GFP) or GFP and RLX (C2C12/RLX), are capable of improving long-term heart remodelling in a rat model of surgically induced chronic myocardial infarction. One month after myocardial infarction, rats were treated with either culture medium (controls), or C2C12/GFP cells, or C2C12/RLX cells plus exogenous RLX, or exogenous RLX alone. The therapeutic effects were monitored for 2 further months. Cell transplantation and exogenous RLX improved the main echocardiographic parameters of cardiac function, increased myocardial viability (assessed by positron emission tomography), decreased cardiac sclerosis and myocardial cell apoptosis and increased microvascular density in the post-infarction scar tissue. These effects were maximal upon treatment with C2C12/RLX plus exogenous RLX. These functional and histopathological findings provide further experimental evidence that myoblast cell grafting can improve myocardial performance and survival during post-infarction heart remodelling and dysfunction. Further, this study provides a proof-of-principle to the novel concept that genetically engineered grafted cells can be effectively employed as cell-based vehicles for the local delivery of therapeutic cardiotropic substances, such as RLX, capable of improving adverse heart remodelling.


Asunto(s)
Regulación de la Expresión Génica , Mioblastos/metabolismo , Infarto del Miocardio/patología , Relaxina/metabolismo , Células Madre/citología , Animales , Supervivencia Celular , Ecocardiografía/métodos , Fibrosis/patología , Proteínas Fluorescentes Verdes/metabolismo , Masculino , Ratones , Miocardio/metabolismo , Ratas , Ratas Wistar
18.
Heart Lung Circ ; 15(5): 314-9, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16860606

RESUMEN

OBJECTIVES: The aims of this study were to (1) compare the release of S-100 beta and NSE in off-pump coronary artery bypass grafting (CABG) versus on-pump surgery; (2) investigate whether the S-100 beta and NSE serum concentrations correlate with cardiopulmonary bypass (CPB) duration. MATERIALS AND METHODS: Between October 2002 and May 2004, 42 patients undergoing first time CABG surgery were enrolled in the study. The exclusion criteria were: LVEF<35%, age>70 years, previous myocardial infarction, REDO surgery, the presence of valvular heart disease and/or cerebrovascular disease, abnormal preoperative carotid vessels angiography, coronary artery disease involving the distal circumflex artery, renal dysfunction, coagulopathy. The patients were randomly assigned either to undergo on-pump CABG surgery [group I, n=24 patients] or off-pump CABG [group II, n=18 patients]. Blood was not re-transfused from the cardiotomy suction. All patients presenting haemolysis were excluded from the study. RESULTS: The preoperative S-100beta was 0.13+/-0.08 (microg/l) and NSE 7+/-1.5 (microg/l) in group I and 0.12+/-0.1 (microg/l) and 6.9+/-2.7 (microg/l), respectively in group II. Six hours after the surgery, S-100beta in patients of group I reached a maximum level of 1.38+/-0.4 (microg/l) and NSE of 17.7+/-6.5 (microg/l) compared to 0.5+/-0.11 (microg/l) [S-100B] and NSE 8.6+/-4.2 (microg/l) in group II (p=0.001). Three (12%) patients in group I and none (0%) in group II suffered postoperative delirium, p=0.247. No strokes occurred linear regression analysis revealed a strong correlation between cardiopulmonary bypass duration and S-100beta and NSE peak levels, p<0.0021 (r(2)=0.36) and p<0.0001 (r=0.81), respectively. CONCLUSION: Coronary artery bypass surgery with CPB causes a significantly greater increase in NSE and S-100beta serum levels than off-pump surgery and correlates with CPB duration.


Asunto(s)
Encéfalo/metabolismo , Puente de Arteria Coronaria Off-Pump , Enfermedad Coronaria/sangre , Factores de Crecimiento Nervioso/sangre , Fosfopiruvato Hidratasa/sangre , Proteínas S100/sangre , Anciano , Biomarcadores/sangre , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Subunidad beta de la Proteína de Unión al Calcio S100 , Resultado del Tratamiento
19.
Heart Vessels ; 21(2): 69-77, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16550306

RESUMEN

Total arterial myocardial revascularization (TAMR) is advisable because of the excellent long-term patency of arterial conduits. We present early and midterm outcomes of five different surgical configurations for TAMR. Between January 1998 and May 2004, 112 patients (aged 56.5 +/- 4.5 years, 20% female) with three-vessel disease underwent TAMR. The internal mammary arteries (IMAs) were harvested in a sketelonized fashion. The surgical techniques for TAMR consisted in Y or T composite grafts (n = 88, 78%) constructed between the in situ right IMA (RIMA) and the free left IMA (LIMA) graft (n = 58) or the radial artery (n = 30) (RA) in three different configurations. The other techniques consisted in T- and inverted T-graft (n = 24, 22%) constructed between the RA conduit and the free LIMA graft in two different configurations. The mean follow-up time was 40 +/- 23 months. Postoperative angiographic control was performed in 76/111 (70%) patients. Overall, 472 arterial anastomoses (average 4.2 per patient) were performed. One (0.9%) patient, undergoing the inverted T-graft technique, died on postoperative day 2. Another patient (0.9%), undergoing the lambda-graft technique using both IMAs and RA, suffered a new myocardial infarction probably due to RA conduit vasospasm. One week after surgery, after the transthoracic echocardiographic Doppler with adenosine provocative test, the coronary flow reserve (CFR) at the LIMA and RIMA main stems were 2 +/- 0.4 and 2.4 +/- 0.3, respectively. At 12-month follow-up, after adenosine provocative test, the CFRs at the LIMA and RIMA stems were significantly higher than the values at 1 week after surgery within the same group; (LIMA)CFR (1 week) 2.4 +/- 0.3 (12 months) vs 2 +/- 04 (1 week), P = 0.002; (RIMA)CFR 2.58 +/- 0.4 vs 2.4 +/- 0.3, P = 0.001. The CFR at the RIMA main stem was higher in all measurements within the same group than in the LIMA main stem, but not significantly. In one patient undergoing the lambda-graft technique using both IMAs, the RIMA was found to have a string sign. Postoperative angiography in 50 patients showed that the patency rate for the LIMA was 100%, for the RIMA 97.3%, and for the RA 96.7%. Angiography at 3-year follow-up in 76 patients documented excellent patency rates of the LIMA (97.4%), RIMA (95%), and RA (87%). Survival at 7 years was 92.5%, event-free survival 89.3%, and freedom from angina 94%. Total arterial myocardial revascularization using different surgical configurations is safe and effective. The use of composite arterial grafts provides excellent clinical and angiographic results, with a low rate of angina recurrence and late cardiac events. These configurations allow for complete arterial revascularization.


Asunto(s)
Enfermedad Coronaria/cirugía , Revascularización Miocárdica/métodos , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Puente Cardiopulmonar , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico , Ecocardiografía Doppler , Femenino , Oclusión de Injerto Vascular , Humanos , Anastomosis Interna Mamario-Coronaria , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Arteria Radial/trasplante , Estadísticas no Paramétricas , Tasa de Supervivencia , Resultado del Tratamiento , Grado de Desobstrucción Vascular
20.
Heart Vessels ; 21(1): 20-7, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16440144

RESUMEN

Mitral valve regurgitation (MVR), occurring as a result of myocardial ischemia and global left ventricular (LV) dysfunction, predicts a poor outcome in terms of survival and morbidity. Between 1995 and 2003, 180 consecutive patients with impaired LV function and chronic ischemic MVR underwent cardiac surgery. Fifty-four patients (group I), MVR (grade III-IV) underwent simultaneous MV surgery and coronary artery bypass grafting (CABG); 40 patients (group II), MVR (grade II-III), and 86 patients (group III), MVR (grade I-II), underwent CABG alone. In group I, MV repair was performed in 36 patients (group IA) and MV replacement in 18 (group IB). The incidence of hospital death was similar between groups. The actuarial event-free survival was significantly lower in group than in groups II and III (P = 0.0045) and I (P = 0.038). The overall actuarial survival was significantly higher in group IA than in group IB (P = 0.027). Postoperatively, the LV ejection fraction (P < 0.001), LV end-diastolic diameter (P < 0.001), LV end-systolic diameter (P < 0.01), and cardiac index (P < 0.001) improved significantly in group I. The regurgitation fraction decreased significantly in Groups I and III after surgery (P < 0.001 and P = 0.003, respectively). Both MV repair and replacement that preserves subvalvular apparatus in patients with end-stage ischemic myocardiopathy offer an acceptable outcome. Mitral valve repair simultaneous to CABG improves significantly the LV function and its geometry. In patients with mild to moderate mitral regurgitation, CABG alone may be performed with good overall survival, but with lower event-free survival than those undergoing concomitant mitral valve repair.


Asunto(s)
Cardiomiopatías/cirugía , Puente de Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Isquemia Miocárdica/cirugía , Anciano , Análisis de Varianza , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Enfermedad Crónica , Supervivencia sin Enfermedad , Ecocardiografía Doppler en Color , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/cirugía , Remodelación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...