1.
Biomaterials ; 28(6): 1209-17, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17129601

RESUMEN

Complications following endovascular aneurysm repair (EVAR) are related to deficient healing around the stent-graft (SG). New generations of SG with surface properties that foster vascular repair could overcome this limitation. Our goal was to evaluate the potential of a new nitrogen-rich plasma-polymerised biomaterial, designated PPE:N, as an external coating for polyethylene terephtalate (PET)- or polytetrafluoro-ethylene (PTFE)-based SGs, to promote healing around the implant. Thin PPE:N coatings were deposited on PET and PTFE films. Then, adhesion, growth, migration and resistance to apoptosis of vascular smooth muscle cells (VSMCs) and fibroblasts, as well as myofibroblast differentiation, were assessed in vitro. In another experimental group, chondroitin sulphate (CS), a newly described mediator of vascular repair, was added to normal culture medium, to search for possible additional benefit. PPE:N-coatings, especially on PET, increased and accelerated cell adhesion and growth, compared with control PET and with standard polystyrene culture plates (PCP). PPE:N was also found to increase the resistance to apoptosis in VSMC, an important finding as aneurysms are characterised by VMSC depletion caused by a pro-apoptotic phenotype. Addition of CS in solution further increased migration and resistance to apoptosis. In conclusion, PPE:N-coating and/or CS could promote vascular repair around SGs following EVAR.


Asunto(s)
Aneurisma/cirugía , Prótesis Vascular/efectos adversos , Células Endoteliales/efectos de los fármacos , Nitrógeno/administración & dosificación , Stents/efectos adversos , Cicatrización de Heridas/efectos de los fármacos , Aneurisma/complicaciones , Aneurisma/patología , Animales , Línea Celular , Materiales Biocompatibles Revestidos/administración & dosificación , Materiales Biocompatibles Revestidos/química , Implantes de Medicamentos , Células Endoteliales/patología , Ensayo de Materiales , Nitrógeno/química , Ratas
2.
J Endovasc Ther ; 13(4): 457-67, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16928159

RESUMEN

PURPOSE: To study explanted stent-grafts to achieve a better understanding of the mechanisms of failure after endovascular treatment of abdominal aortic aneurysms (AAA). METHODS: Twelve stent-grafts were harvested at autopsy (n=3) or during surgical conversion (n=9). Device alterations were investigated by macroscopic examination, radiography, and surface analysis techniques. Healing around the implants was studied via histology and immunohistochemistry, with particular attention to the stent-graft/tissue interface. RESULTS: Degradation was more important with Vanguard stent-grafts (off the market) than with AneuRx and Talent stent-grafts, but rupture of nitinol wires and poor surface finish in Talent stent-grafts raise concern about their corrosion resistance and long-term stability. Poor healing was observed around stent-grafts even after several years of implantation, with absence of vascular smooth muscle cells, fibroblasts, and collagen formation. In addition to the well-known foreign body reaction around the graft, numerous polymorphonuclear cells characteristic of the first step of healing were present in tissues around stent-grafts retrieved at surgical conversion. Factors explaining the lack of tissue organization around stent-grafts are discussed. CONCLUSION: The long-term stability of implants remains a concern and requires more transparency from manufacturers regarding the surface properties of their devices. Lack of neointima formation impairs biological fixation of the implant to the vessel wall, leading to possible endoleaks and migration. New-generation stent-grafts promoting biological fixation should be developed to improve clinical outcomes of this minimally invasive treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular/efectos adversos , Falla de Prótesis , Stents/efectos adversos , Anciano , Anciano de 80 o más Años , Aleaciones , Aorta Abdominal/patología , Aorta Abdominal/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polipropilenos , Túnica Íntima/patología , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS