Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Virus Evol ; 10(1): veae023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38544854

RESUMEN

Widespread surveillance, rapid detection, and appropriate intervention will be critical for successful eradication of poliovirus. Using deployable next-generation sequencing (NGS) approaches, such as Oxford Nanopore Technologies' MinION, the time from sample to result can be significantly reduced compared to cell culture and Sanger sequencing. We developed piranha (poliovirus investigation resource automating nanopore haplotype analysis), a 'sequencing reads-to-report' solution to aid routine poliovirus testing of both stool and environmental samples and alleviate the bioinformatic bottleneck that often exists for laboratories adopting novel NGS approaches. Piranha can be used for efficient intratypic differentiation of poliovirus serotypes, for classification of Sabin-like polioviruses, and for detection of wild-type and vaccine-derived polioviruses. It produces interactive, distributable reports, as well as summary comma-separated values files and consensus poliovirus FASTA sequences. Piranha optionally provides phylogenetic analysis, with the ability to incorporate a local database, processing from raw sequencing reads to an interactive, annotated phylogeny in a single step. The reports describe each nanopore sequencing run with interpretable plots, enabling researchers to easily detect the presence of poliovirus in samples and quickly disseminate their results. Poliovirus eradication efforts are hindered by the lack of real-time detection and reporting, and piranha can be used to complement direct detection sequencing approaches.

2.
J Gen Virol ; 104(11)2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37910158

RESUMEN

Enteroviruses primarily affect young children with a varying severity of disease. Recent outbreaks of severe respiratory and neurological disease due to EV-D68 and EV-A71, as well as atypical hand-foot-and-mouth-disease due to CVA6, have brought to light the potency of enteroviruses to emerge as severe human pathogens. Enterovirus D111 (EV-D111) is an enteric pathogen initially detected in Central Africa in human and wildlife samples and was recently detected in environmental samples. The natural history and epidemiology of EV-D111 are poorly studied. Here, the presence of serum neutralizing antibodies to EV-D111 was estimated in human and wildlife samples from five countries. We report high prevalence of neutralizing antibodies measured against EV-D111 in human populations (range, 55-83 %), a proxy for previous infection, which indicates active virus circulation in absence of detection in clinical cases and a high number of undiagnosed infections. Notably, seroprevalence in samples from the UK varied by age and was higher in children and older adults (1-5 and >60 years old), but lower in ages 11-60. EV-D111 seroprevalence in apes and Old World monkeys was 50 % (33-66 %), which also suggests prior exposure and supports existing knowledge of enterovirus circulation in wild and captive apes and Old World monkeys. Generally, reported cases of infection likely underestimate the prevalence of infection particularly when the knowledge of community transmission is limited. Continued serologic surveillance and detection of EV-D111 in clinical and environmental samples will allow for a more robust assessment of EV-D111 epidemiology.


Asunto(s)
Infecciones por Enterovirus , Enterovirus , Hominidae , Animales , Humanos , Preescolar , Anciano , Estudios Transversales , Prevalencia , Estudios Seroepidemiológicos , Primates , Infecciones por Enterovirus/epidemiología , Infecciones por Enterovirus/veterinaria , Cercopithecidae , Animales Salvajes , Anticuerpos Neutralizantes , Antígenos Virales
3.
Front Immunol ; 14: 1135834, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36936936

RESUMEN

The global polio eradication campaign has had remarkable success in reducing wild-type poliovirus infection, largely built upon the live attenuated Sabin oral poliovirus vaccine. Whilst rare, vaccine poliovirus strains may cause infection and subsequently revert to a neurovirulent type, termed vaccine-derived poliovirus (VDPV). Persistent, vaccine derived infection may occur in an immunocompromised host (iVDPV), where it is a recognised complication following receipt of the Sabin vaccine. This has significant implications for the global polio eradication campaign and there is currently no agreed global strategy to manage such patients.Here we describe a case of a 50-year-old man with common variable immune deficiency, persistently infected with a neurovirulent vaccine-derived type 2 poliovirus following vaccination in childhood. iVDPV infection had proven resistant to multiple prior attempts at treatment with human breast milk, ribavirin and oral administration of a normal human pooled immunoglobulin product. His iVDPV infection subsequently resolved after 12 days treatment with remdesivir, an adenosine analogue prodrug that is an inhibitor of viral RNA-dependent RNA polymerase, administered as treatment for a prolonged, moderate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. iVDPV from the patient, isolated prior to treatment, was subsequently demonstrated to be sensitive to remdesivir in vitro. Based on the observations made in this case, and the mechanistic rationale for use with iVDPV, there is strong justification for further clinical studies of remdesivir treatment as a potentially curative intervention in patients with iVDPV infection.


Asunto(s)
COVID-19 , Síndromes de Inmunodeficiencia , Poliomielitis , Vacuna Antipolio Oral , Poliovirus , Femenino , Humanos , Masculino , Persona de Mediana Edad , COVID-19/complicaciones , Tratamiento Farmacológico de COVID-19 , Poliomielitis/tratamiento farmacológico , Poliomielitis/etiología , Poliomielitis/prevención & control , Vacuna Antipolio Oral/efectos adversos , SARS-CoV-2
4.
Microbiol Spectr ; : e0425222, 2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36939356

RESUMEN

Direct detection by PCR of poliovirus RNA in stool samples provides a rapid diagnostic and surveillance tool that can replace virus isolation by cell culture in global polio surveillance. The sensitivity of direct detection methods is likely to depend on the choice of RNA extraction method and sample volume. We report a comparative analysis of 11 nucleic acid extraction methods (7 manual and 4 semiautomated) for poliovirus molecular detection using stool samples (n = 59) that had been previously identified as poliovirus positive by cell culture. To assess the effect of RNA recovery methods, extracted RNA using each of the 11 methods was tested with a poliovirus-specific reverse transcription-quantitative PCR (RT-qPCR), a pan-poliovirus RT-PCR (near-whole-genome amplification), a pan-enterovirus RT-PCR (entire capsid region), and a nested VP1 PCR that is the basis of a direct detection method based on nanopore sequencing. We also assessed extracted RNA integrity and quantity. The overall effect of extraction method on poliovirus PCR amplification assays tested in this study was found to be statistically significant (P < 0.001), thus indicating that the choice of RNA extraction method is an important component that needs to be carefully considered for any diagnostic based on nucleic acid amplification. Performance of the methods was generally consistent across the different assays used. Of the 11 extraction methods tested, the MagMAX viral RNA isolation kit used manually or automatically was found to be the preferable method for poliovirus molecular direct detection considering performance, cost, and processing time. IMPORTANCE Poliovirus, the causative agent of poliomyelitis, is a target of global eradication led by the World Health Organization since 1988. Direct molecular detection and genomic sequencing without virus propagation in cell culture is arguably a critical tool in the final stages of polio eradication. Efficient recovery of good-quality viral RNA from stool samples is a prerequisite for direct detection by nucleic acid amplification. We tested 11 nucleic acid extraction methods to identify those facilitating sensitive, fast, simple, and cost-effective extraction, with flexibility for manual and automated protocols considered. Several different PCR assays were used to compare the recovered viral RNA to test suitability for poliovirus direct molecular detection. Our findings highlight the importance of choosing a suitable RNA extraction protocol and provide useful information to diagnostic laboratories and researchers facing the choice of RNA extraction method for direct molecular virus detection from stool.

5.
Lancet ; 400(10362): 1531-1538, 2022 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-36243024

RESUMEN

BACKGROUND: The international spread of poliovirus exposes all countries to the risk of outbreaks and is designated a Public Health Emergency of International Concern by WHO. This risk can be exacerbated in countries using inactivated polio vaccine, which offers excellent protection against paralysis but is less effective than oral vaccine against poliovirus shedding, potentially allowing circulation without detection of paralytic cases for long periods of time. Our study investigated the molecular properties of type 2 poliovirus isolates found in sewage with an aim to detect virus transmission in the community. METHODS: We performed environmental surveillance in London, UK, testing sewage samples using WHO recommended methods that include concentration, virus isolation in cell culture, and molecular characterisation. We additionally implemented direct molecular detection and determined whole-genome sequences of every isolate using novel nanopore protocols. FINDINGS: 118 genetically linked poliovirus isolates related to the serotype 2 Sabin vaccine strain were detected in 21 of 52 sequential sewage samples collected in London between Feb 8 and July 4, 2022. Expansion of environmental surveillance sites in London helped localise transmission to several boroughs in north and east London. All isolates have lost two key attenuating mutations, are recombinants with a species C enterovirus, and an increasing proportion (20 of 118) meet the criterion for a vaccine-derived poliovirus, having six to ten nucleotide changes in the gene coding for VP1 capsid protein. INTERPRETATION: Environmental surveillance allowed early detection of poliovirus importation and circulation in London, permitting a rapid public health response, including enhanced surveillance and an inactivated polio vaccine campaign among children aged 1-9 years. Whole-genome sequences generated through nanopore sequencing established linkage of isolates and confirmed transmission of a unique recombinant poliovirus lineage that has now been detected in Israel and the USA. FUNDING: Medicines and Healthcare products Regulatory Agency, UK Health Security Agency, Bill & Melinda Gates Foundation, and National Institute for Health Research Medical Research Council.


Asunto(s)
Poliomielitis , Poliovirus , Niño , Humanos , Poliovirus/genética , Aguas del Alcantarillado , Poliomielitis/epidemiología , Poliomielitis/prevención & control , Londres/epidemiología , Vacuna Antipolio Oral , Vacuna Antipolio de Virus Inactivados , Monitoreo del Ambiente/métodos
6.
MMWR Morb Mortal Wkly Rep ; 71(24): 786-790, 2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35709073

RESUMEN

The emergence and international spread of neurovirulent circulating vaccine-derived polioviruses (cVDPVs) across multiple countries in Africa and Asia in recent years pose a major challenge to the goal of eradicating all forms of polioviruses. Approximately 90% of all cVDPV outbreaks are caused by the type 2 strain of the Sabin vaccine, an oral live, attenuated vaccine; cVDPV outbreaks typically occur in areas of persistently low immunization coverage (1). A novel type 2 oral poliovirus vaccine (nOPV2), produced by genetic modification of the type 2 Sabin vaccine virus genome (2), was developed and evaluated through phase I and phase II clinical trials during 2017-2019. nOPV2 was demonstrated to be safe and well-tolerated, have noninferior immunogenicity, and have superior genetic stability compared with Sabin monovalent type 2 (as measured by preservation of the primary attenuation site [domain V in the 5' noncoding region] and significantly lower neurovirulence of fecally shed vaccine virus in transgenic mice) (3-5). These findings indicate that nOPV2 could be an important tool in reducing the risk for generating vaccine-derived polioviruses (VDPVs) and the risk for vaccine-associated paralytic poliomyelitis cases. Based on the favorable preclinical and clinical data, and the public health emergency of international concern generated by ongoing endemic wild poliovirus transmission and cVDPV type 2 outbreaks, the World Health Organization authorized nOPV2 for use under the Emergency Use Listing (EUL) pathway in November 2020, allowing for its first use for outbreak response in March 2021 (6). As required by the EUL process, among other EUL obligations, an extensive plan was developed and deployed for obtaining and monitoring nOPV2 isolates detected during acute flaccid paralysis (AFP) surveillance, environmental surveillance, adverse events after immunization surveillance, and targeted surveillance for adverse events of special interest (i.e., prespecified events that have the potential to be causally associated with the vaccine product), during outbreak response, as well as through planned field studies. Under this monitoring framework, data generated from whole-genome sequencing of nOPV2 isolates, alongside other virologic data for isolates from AFP and environmental surveillance systems, are reviewed by the genetic characterization subgroup of an nOPV working group of the Global Polio Eradication Initiative. Global nOPV2 genomic surveillance during March-October 2021 confirmed genetic stability of the primary attenuating site. Sequence data generated through this unprecedented global effort confirm the genetic stability of nOPV2 relative to Sabin 2 and suggest that nOPV2 will be an important tool in the eradication of poliomyelitis. nOPV2 surveillance should continue for the duration of the EUL.


Asunto(s)
Poliomielitis , Vacuna Antipolio Oral , Poliovirus , Animales , Enfermedades Virales del Sistema Nervioso Central/prevención & control , Brotes de Enfermedades/prevención & control , Humanos , Ratones , Mielitis/prevención & control , Enfermedades Neuromusculares/prevención & control , Poliomielitis/epidemiología , Poliomielitis/etiología , Poliomielitis/prevención & control , Poliovirus/genética , Vacuna Antipolio Oral/efectos adversos , Vacuna Antipolio Oral/genética , Vacunas Atenuadas/efectos adversos , Vacunas Atenuadas/genética
7.
Viruses ; 14(1)2022 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-35062346

RESUMEN

Infection with enterovirus D68 (EV-D68) has been linked with severe neurological disease such as acute flaccid myelitis (AFM) in recent years. However, active surveillance for EV-D68 is lacking, which makes full assessment of this association difficult. Although a high number of EV-D68 infections were expected in 2020 based on the EV-D68's known biannual circulation patterns, no apparent increase in EV-D68 detections or AFM cases was observed during 2020. We describe an upsurge of EV-D68 detections in wastewater samples from the United Kingdom between July and November 2021 mirroring the recently reported rise in EV-D68 detections in clinical samples from various European countries. We provide the first publicly available 2021 EV-D68 sequences showing co-circulation of EV-D68 strains from genetic clade D and sub-clade B3 as in previous years. Our results show the value of environmental surveillance (ES) for the early detection of circulating and clinically relevant human viruses. The use of a next-generation sequencing (NGS) approach helped us to estimate the prevalence of EV-D68 viruses among EV strains from other EV serotypes and to detect EV-D68 minor variants. The utility of ES at reducing gaps in virus surveillance for EV-D68 and the possible impact of nonpharmaceutical interventions introduced to control the COVID-19 pandemic on EV-D68 transmission dynamics are discussed.


Asunto(s)
Enterovirus Humano D/aislamiento & purificación , Aguas Residuales/virología , COVID-19/epidemiología , COVID-19/prevención & control , Proteínas de la Cápside/genética , Enterovirus Humano D/clasificación , Enterovirus Humano D/genética , Humanos , Filogenia , ARN Viral/genética , SARS-CoV-2 , Análisis de Secuencia de ADN , Reino Unido/epidemiología , Monitoreo Epidemiológico Basado en Aguas Residuales , Microbiología del Agua
8.
Vaccines (Basel) ; 9(8)2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-34451995

RESUMEN

Response to and monitoring of viral outbreaks can be efficiently focused when rapid, quantitative, kinetic information provides the location and the number of infected individuals. Environmental surveillance traditionally provides information on location of populations with contagious, infected individuals since infectious poliovirus is excreted whether infections are asymptomatic or symptomatic. Here, we describe development of rapid (1 week turnaround time, TAT), quantitative RT-PCR of poliovirus RNA extracted directly from concentrated environmental surveillance samples to infer the number of infected individuals excreting poliovirus. The quantitation method was validated using data from vaccination with bivalent oral polio vaccine (bOPV). The method was then applied to infer the weekly number of excreters in a large, sustained, asymptomatic outbreak of wild type 1 poliovirus in Israel (2013) in a population where >90% of the individuals received three doses of inactivated polio vaccine (IPV). Evidence-based intervention strategies were based on the short TAT for direct quantitative detection. Furthermore, a TAT shorter than the duration of poliovirus excretion allowed resampling of infected individuals. Finally, the method documented absence of infections after successful intervention of the asymptomatic outbreak. The methodologies described here can be applied to outbreaks of other excreted viruses such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), where there are (1) significant numbers of asymptomatic infections; (2) long incubation times during which infectious virus is excreted; and (3) limited resources, facilities, and manpower that restrict the number of individuals who can be tested and re-tested.

9.
mSystems ; 6(3): e0035321, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34128696

RESUMEN

SARS-CoV-2 variants with multiple amino acid mutations in the spike protein are emerging in different parts of the world, raising concerns regarding their possible impact on human immune response and vaccine efficacy against the virus. Recently, a variant named lineage B.1.1.7 was detected and shown to be rapidly spreading across the UK since November 2020. As surveillance for these SARS-CoV-2 variants of concern (VOCs) becomes critical, we have investigated the use of environmental surveillance (ES) for the rapid detection and quantification of B.1.1.7 viruses in sewage as a way of monitoring its expansion that is independent on the investigation of identified clinical cases. Next-generation sequencing analysis of amplicons synthesized from sewage concentrates revealed the presence of B.1.1.7 mutations in viral sequences, first identified in a sample collected in London on 10 November 2020 and shown to rapidly increase in frequency to >95% in January 2021, in agreement with clinical data over the same period. We show that ES can provide an early warning of VOCs becoming prevalent in the population and that, as well as B.1.1.7, our method can detect VOCs B.1.351 and P.1, first identified in South Africa and Brazil, respectively, and other viruses carrying critical spike mutation E484K, known to have an effect on virus antigenicity. Although we did not detect such mutation in viral RNAs from sewage, we did detect mutations at amino acids 478, 490, and 494, located close to amino acid 484 in the spike protein structure and known to also have an effect on antigenicity. IMPORTANCE The recent appearance and growth of new SARS-CoV-2 variants represent a major challenge for the control of the COVID-19 pandemic. These variants of concern contain mutations affecting antigenicity, which raises concerns on their possible impact on human immune response to the virus and vaccine efficacy against them. Here, we show how environmental surveillance for SARS-CoV-2 can be used to help us understand virus transmission patterns and provide an early warning of variants becoming prevalent in the population. We describe the detection and quantification of variant B.1.1.7, first identified in southeast England in sewage samples from London (UK) before widespread transmission of this variant was obvious from clinical cases. Variant B.1.1.7 was first detected in a sample from early November 2020, with the frequency of B.1.1.7 mutations detected in sewage rapidly increasing to >95% in January 2021, in agreement with increasing SARS-CoV-2 infections associated with B.1.1.7 viruses.

10.
Viruses ; 13(4)2021 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-33918088

RESUMEN

There are increasing concerns of infections by enteroviruses (EVs) causing severe disease in humans. EV diagnostic laboratory methods show differences in sensitivity and specificity as well as the level of genetic information provided. We examined a detection method for EVs based on next generation sequencing (NGS) analysis of amplicons covering the entire capsid coding region directly synthesized from clinical samples. One hundred and twelve clinical samples from England; previously shown to be positive for EVs, were analyzed. There was high concordance between the results obtained by the new NGS approach and those from the conventional Sanger method used originally with agreement in the serotypes identified in the 83 samples that were typed by both methods. The sensitivity and specificity of the NGS method compared to those of the conventional Sanger sequencing typing assay were 94.74% (95% confidence interval, 73.97% to 99.87%) and 97.85% (92.45% to 99.74%) for Enterovirus A, 93.75% (82.80% to 98.69%) and 89.06% (78.75% to 95.49%) for Enterovirus B, 100% (59.04% to 100%) and 98.10% (93.29% to 99.77%) for Enterovirus C, and 100% (75.29% to 100%) and 100% (96.34% to 100%) for Enterovirus D. The NGS method identified five EVs in previously untyped samples as well as additional viruses in some samples, indicating co-infection. This method can be easily expanded to generate whole-genome EV sequences as we show here for EV-D68. Information from capsid and whole-genome sequences is critical to help identifying the genetic basis for changes in viral properties and establishing accurate spatial-temporal associations between EV strains of public health relevance.


Asunto(s)
Proteínas de la Cápside/genética , Infecciones por Enterovirus/virología , Enterovirus/clasificación , Enterovirus/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Secuenciación Completa del Genoma , Inglaterra , Enterovirus/aislamiento & purificación , Infecciones por Enterovirus/sangre , Infecciones por Enterovirus/líquido cefalorraquídeo , Heces/virología , Genoma Viral , Humanos , Filogenia , ARN Viral/genética , Sensibilidad y Especificidad , Serogrupo
11.
Viruses ; 13(2)2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33562806

RESUMEN

Human enteroviruses (EVs) are highly prevalent in sewage and have been associated with human diseases with complications leading to severe neurological syndromes. We have used a recently developed molecular method to investigate the presence of EVs in eight samples collected in 2017-2018 from water streams contaminated by drainage channels in three different locations in Nigeria. A total of 93 human EV strains belonging to 45 different serotypes were identified, far exceeding the number of strains and serotypes found in similar samples in previous studies. Next generation sequencing analysis retrieved whole-capsid genomic nucleotide sequences of EV strains belonging to all four A, B, C, and D species. Our results further demonstrate the value of environmental surveillance for the detection of EV transmission of both serotypes commonly associated with clinical syndromes, such as EV-A71, and those that appear to circulate silently but could eventually cause outbreaks and disease. Several uncommon serotypes, rarely reported elsewhere, were detected such as EV-A119, EV-B87, EV-C116, and EV-D111. Ten EV serotypes were detected in Nigeria for the first time and two of them, CV-A12 and EV-B86, firstly described in Africa. This method can be expanded to generate whole-genome EV sequences as we show here for one EV-D111 strain. Our data revealed phylogenetic relationships of Nigerian sewage strains with EV strains reported elsewhere, mostly from African origin, and provided new insights into the whole-genome structure of emerging serotype EV-D111 and recombination events among EV-D serotypes.


Asunto(s)
Enterovirus/genética , Enterovirus/aislamiento & purificación , Microbiología del Agua , Proteínas de la Cápside/genética , Enterovirus/clasificación , Monitoreo del Ambiente , Genoma Viral/genética , Humanos , Nigeria , Filogenia , ARN Viral/genética , Recombinación Genética , Serogrupo , Aguas del Alcantarillado/virología
12.
Viruses ; 12(10)2020 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-33050264

RESUMEN

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), responsible for the ongoing coronavirus disease (COVID-19) pandemic, is frequently shed in faeces during infection, and viral RNA has recently been detected in sewage in some countries. We have investigated the presence of SARS-CoV-2 RNA in wastewater samples from South-East England between 14th January and 12th May 2020. A novel nested RT-PCR approach targeting five different regions of the viral genome improved the sensitivity of RT-qPCR assays and generated nucleotide sequences at sites with known sequence polymorphisms among SARS-CoV-2 isolates. We were able to detect co-circulating virus variants, some specifically prevalent in England, and to identify changes in viral RNA sequences with time consistent with the recently reported increasing global dominance of Spike protein G614 pandemic variant. Low levels of viral RNA were detected in a sample from 11th February, 3 days before the first case was reported in the sewage plant catchment area. SARS-CoV-2 RNA concentration increased in March and April, and a sharp reduction was observed in May, showing the effects of lockdown measures. We conclude that viral RNA sequences found in sewage closely resemble those from clinical samples and that environmental surveillance can be used to monitor SARS-CoV-2 transmission, tracing virus variants and detecting virus importations.


Asunto(s)
Betacoronavirus/genética , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Neumonía Viral/epidemiología , Neumonía Viral/virología , Aguas del Alcantarillado/virología , Betacoronavirus/aislamiento & purificación , COVID-19 , Inglaterra/epidemiología , Monitoreo del Ambiente , Variación Genética , Genoma Viral/genética , Humanos , Pandemias , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2 , Análisis de Secuencia de ADN , Aguas Residuales/virología
13.
J Clin Microbiol ; 58(9)2020 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-32611795

RESUMEN

Global poliovirus surveillance involves virus isolation from stool and environmental samples, intratypic differential (ITD) by PCR, and sequencing of the VP1 region to distinguish vaccine (Sabin), vaccine-derived, and wild-type polioviruses and to ensure an appropriate response. This cell culture algorithm takes 2 to 3 weeks on average between sample receipt and sequencing. Direct detection of viral RNA using PCR allows faster detection but has traditionally faced challenges related to poor sensitivity and difficulties in sequencing common samples containing poliovirus and enterovirus mixtures. We present a nested PCR and nanopore sequencing protocol that allows rapid (<3 days) and sensitive direct detection and sequencing of polioviruses in stool and environmental samples. We developed barcoded primers and a real-time analysis platform that generate accurate VP1 consensus sequences from multiplexed samples. The sensitivity and specificity of our protocol compared with those of cell culture were 90.9% (95% confidence interval, 75.7% to 98.1%) and 99.2% (95.5% to 100.0%) for wild-type 1 poliovirus, 92.5% (79.6% to 98.4%) and 98.7% (95.4% to 99.8%) for vaccine and vaccine-derived serotype 2 poliovirus, and 88.3% (81.2% to 93.5%) and 93.2% (88.6% to 96.3%) for Sabin 1 and 3 poliovirus alone or in mixtures when tested on 155 stool samples in Pakistan. Variant analysis of sequencing reads also allowed the identification of polioviruses and enteroviruses in artificial mixtures and was able to distinguish complex mixtures of polioviruses in environmental samples. The median identity of consensus nanopore sequences with Sanger or Illumina sequences from the same samples was >99.9%. This novel method shows promise as a faster and safer alternative to cell culture for the detection and real-time sequencing of polioviruses in stool and environmental samples.


Asunto(s)
Secuenciación de Nanoporos , Poliomielitis , Poliovirus , Monitoreo del Ambiente , Heces , Humanos , Poliomielitis/diagnóstico , Poliovirus/genética , Vacuna Antipolio Oral
14.
Virusdisease ; 30(2): 302-306, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31179370

RESUMEN

Viral hepatitis E is gaining importance as an emerging worldwide disease. Though viral hepatitis E (HEV) has been attributed as an etiology of acute liver failure (ALF), however its actual incidence and the immunopathogenesis are being under explored. The present study is aimed at detecting HEV in post mortem liver tissues of patients with undiagnosed ALF. Twenty six liver tissues of ALF patients died of unknown etiology are subjected to nested reverse transcriptase PCR with HEV ORF1 gene targeted primers and HEV RNA is detected in 30.4% (7/23) of ALF cases. Out of seven HEV RNA positive cases, three (42.8%) had HEV antigen positivity by immunohistochemistry on liver tissues using HEV ORF2 antibody. Histopathological examination by H&E staining shows multiacinar confluent hepatic necrosis, bile ductular proliferation, bridging hepatic and periportal necrosis in 4, 4, 2 and 1 cases respectively. The isolates were sequenced using RdRp gene specific primers and found to HEV genotype-1. Quantitative TaqMan real time PCR estimated the viral load ranged between 7.77 × 103 and 1.44 × 107 viral copies/µl. HEV has been associated with 30.4% (7/23) of undiagnosed ALF cases. Immuno-histochemistry along with molecular testing in FFPE biopsies might be useful for the detection of HEV in undiagnosed cases.

15.
Open Forum Infect Dis ; 5(10): ofy250, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30377626

RESUMEN

BACKGROUND: Enteroviruses are common human pathogens occasionally associated with severe disease, notoriously paralytic poliomyelitis caused by poliovirus. Other enterovirus serotypes such as enterovirus A71 and D68 have been linked to severe neurological syndromes. New enterovirus serotypes continue to emerge, some believed to be derived from nonhuman primates. However, little is known about the circulation patterns of many enterovirus serotypes and, in particular, the detailed enterovirus composition of sewage samples. METHODS: We used a next-generation sequencing approach analyzing reverse transcriptase polymerase chain reaction products synthesized directly from sewage concentrates. RESULTS: We determined whole-capsid genome sequences of multiple enterovirus strains from all 4 A to D species present in environmental samples from the United Kingdom, Senegal, and Pakistan. CONCLUSIONS: Our results indicate complex enterovirus circulation patterns in human populations with differences in serotype composition between samples and evidence of sustained and widespread circulation of many enterovirus serotypes. Our analyses revealed known and divergent enterovirus strains, some of public health relevance and genetically linked to clinical isolates. Enteroviruses identified in sewage included vaccine-derived poliovirus and enterovirus D-68 stains, new enterovirus A71 and coxsackievirus A16 genogroups indigenous to Pakistan, and many strains from rarely reported serotypes. We show how this approach can be used for the early detection of emerging pathogens and to improve our understanding of enterovirus circulation in humans.

16.
Front Microbiol ; 9: 1956, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30186268

RESUMEN

Background: Human enteroviruses (EVs) have been linked with severe disease and syndromes as varied as acute respiratory illness, myocarditis, and flaccid paralysis. With global polio eradication on sight the focus of clinical investigations has expanded to the identification of other EV serotypes associated with severe neurological conditions such as EV-D68, responsible for large outbreaks in 2014 and 2016 that spread worldwide and were related with severe respiratory disease leading to acute myelitis in some cases. New EV serotypes with epidemic potential continue to emerge such as EV-C104, EV-C105, EV-C109, and EV-C117 identified in respiratory samples in recent years. Methods: We used a next generation sequencing (NGS) approach to detect multiple EV serotypes directly in a sewage concentrate from Glasgow (Scotland, United Kingdom) generating whole-capsid nucleotide sequences that were compared to sequences of cell culture isolates from this sewage sample and clinical EV isolates from GenBank. Results: Thirteen different serotypes belonging to all four A, B, C, and D EV species were identified in the sewage concentrate. EV strains closely related to EV-D68 epidemic isolates of B3 lineage reported in the United States and Europe in 2016 and to EV-C109 respiratory isolates found in Denmark and Netherlands in 2015 were identified. Conclusion: Environmental surveillance (ES) can effectively detect EV circulation in human populations. The use of NGS for ES can help overcoming the limitations of traditional cell culture and sequencing methods, which are selective and biased, and can contribute to the early detection and assessment of spread of emerging EV pathogens.

17.
J Virol Methods ; 260: 62-69, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30003926

RESUMEN

Environmental surveillance (EnvS)2 is an important tool for monitoring the presence of poliovirus in endemic and poliovirus free regions. Unlike acute flaccid paralysis (AFP)3 surveillance, EnvS can monitor large populations using small numbers of samples and detect the introduction of poliovirus even before the appearance of AFP cases. Early detection and timely response can prevent the onset of poliovirus associated AFP, as was demonstrated by silent poliovirus transmission in Israel in 2013. Although EnvS is currently recommended as supplementary to AFP surveillance, it is limited to laboratories with equipment for poliovirus concentration and to regions where samples can be easily transported under temperature controlled conditions to such facilities. However the highest risk of poliovirus re-emergence is in developing countries where such conditions do not exist. We developed and evaluated an affinity purification method using antibody or poliovirus receptor (CD155) presenting bacteriophage covered magnetic beads for poliovirus concentration. This method requires only simple, inexpensive and portable equipment. Though tested only on Sabin 1 spiked sewage samples it provided better recovery than our current polyethylene glycol (PEG)4/NaCl- based concentration method. On site use of this method might facilitate EnvS in currently inaccessible remote regions by significantly reducing the volume of sample that needs to be transported back to the laboratory under temperature-controlled conditions5.


Asunto(s)
Monitoreo del Ambiente/métodos , Poliomielitis/prevención & control , Poliovirus/aislamiento & purificación , Anticuerpos Monoclonales/química , Anticuerpos Antivirales/química , Proteínas de Unión al GTP/química , Humanos , Imanes , Microesferas , Poliomielitis/virología , ARN Viral/química , Receptores Virales/química , Factores de Tiempo , Acoplamiento Viral
18.
Emerg Infect Dis ; 24(4): 754-757, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29553325

RESUMEN

We analyzed whole-genome sequences of 8 enterovirus A71 isolates (EV-A71). We confirm the circulation of genogroup C and the new genogroup E in West Africa. Our analysis demonstrates wide geographic circulation and describes genetic exchanges between EV-A71 and autochthonous EV-A that might contribute to the emergence of pathogenic lineages.


Asunto(s)
Enterovirus Humano A/clasificación , Enterovirus Humano A/genética , Infecciones por Enterovirus/epidemiología , Infecciones por Enterovirus/virología , Variación Genética , Genoma Viral , Genotipo , Humanos , Filogenia , Recombinación Genética
19.
Sci Rep ; 8(1): 2181, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29391547

RESUMEN

Enterovirus B69 (EV-B69) is a rarely reported type and till date, only the full-length genome sequence of the prototype strain is available. Besides the prototype strain, only limited VP1 sequences of this virus from Africa and India are available in GenBank. In this study, we analyzed the full-length genome sequence of an EV-B69 strain recovered from a patient with acute flaccid paralysis in Niger. Compared with the EV-B69 prototype strain, it had 79.6% and 76.3% nucleotide identity in the complete genome and VP1 coding region, respectively. VP1 sequence analyses revealed also high variation in nucleotide similarity (68.9%-82.8%) with previously isolated EV-B69 strains in India and Africa. The great genetic divergence among EV-B69 strains indicates that this type is not a newly emergent virus, but has circulated for many years at low epidemic strength. Phylogenetic incongruity between structural and non-structural regions and similarity plot analyses revealed that multiple recombination events occurred during its evolution. This study expands the number of EV-B69 whole genome sequences which would help genomic comparison for future studies to understand the biological and pathogenic properties of this virus, assess its potential public health impact and comprehend the role of recombination in the evolution of enteroviruses.


Asunto(s)
Infecciones por Enterovirus/virología , Enterovirus/genética , Enterovirus/aislamiento & purificación , Genoma Viral , Parálisis/virología , ARN Viral/genética , Secuenciación Completa del Genoma/métodos , Preescolar , Enterovirus/clasificación , Infecciones por Enterovirus/epidemiología , Femenino , Humanos , Niger/epidemiología , Filogenia , Análisis de Secuencia de ADN
20.
J Infect Dis ; 217(8): 1222-1230, 2018 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-29309594

RESUMEN

Background: Environmental surveillance (ES) is a sensitive method for detecting human enterovirus (HEV) circulation, and it is used worldwide to support global polio eradication. We describe a novel ES approach using next-generation sequencing (NGS) to identify HEVs in sewage samples collected in London, United Kingdom, from June 2016 to May 2017. Methods: Two different methods were used to process raw sewage specimens: a 2-phase aqueous separation system and size exclusion by filtration and centrifugation. HEVs were isolated using cell cultures and analyzed using NGS. Results: Type 1 and 3 vaccine-like poliovirus (PV) strains were detected in samples collected from September 2016 through January 2017. NGS analysis allowed us to rapidly obtain whole-genome sequences of PV and non-PV HEV strains. As many as 6 virus strains from different HEV serotypes were identified in a single cell culture flask. PV isolates contained only a small number of mutations from vaccine strains commonly seen in early isolates from vaccinees. Conclusions: Our ES setup has high sensitivity for polio and non-PV HEV detection, generating nearly whole-genome sequence information. Such ES systems provide critical information to assist the polio eradication endgame and contribute to the improvement of our understanding of HEV circulation patterns in humans.


Asunto(s)
Vacunas contra Poliovirus , Poliovirus/clasificación , Poliovirus/genética , Aguas del Alcantarillado/virología , Monitoreo del Ambiente , Genoma Viral , Humanos , Técnicas de Amplificación de Ácido Nucleico , Poliovirus/aislamiento & purificación , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA