Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-31502966

RESUMEN

Scanning acoustic microscopy (SAM) provides high-resolution images of biological tissues. Since higher transducer frequencies limit penetration depth, image resolution enhancement techniques could help in maintaining sufficient lateral resolution without sacrificing penetration depth. Compared with existing SAM research, this work introduces two novelties. First, deep learning (DL) is used to improve lateral resolution of 180-MHz SAM images, comparing it with two deconvolution-based approaches. Second, 316-MHz images are used as ground truth in order to quantitatively evaluate image resolution enhancement. The samples used were mouse and rat brain sections. The results demonstrate that DL can closely approximate ground truth (NRMSE = 0.056 and PSNR = 28.4 dB) even with a relatively limited training set (four images, each smaller than 1 mm ×1 mm). This study suggests the high potential of using DL as a single image superresolution method in SAM.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Acústica/métodos , Animales , Encéfalo/diagnóstico por imagen , Ratones , Ratas
2.
Artículo en Inglés | MEDLINE | ID: mdl-26067054

RESUMEN

The shift-invariant convolution model of ultrasound is widely used in the literature, for instance to generate fast simulations of ultrasound images. However, comparison of the resulting simulations with experiments is either qualitative or based on aggregate descriptors such as envelope statistics or spectral components. In the current work, a planar arrangement of 49-µm polystyrene microspheres was imaged using macrophotography and a 4.7-MHz ultrasound linear array. The macrophotograph allowed estimation of the scattering function (SF) necessary for simulations. Using the coefficient of determination R(2) between real and simulated ultrasound images, different estimates of the SF and point spread function (PSF) were tested. All estimates of the SF performed similarly, whereas the best estimate of the PSF was obtained by Hanningwindowing the deconvolution of the real ultrasound image with the SF: this yielded R(2) = 0.43 for the raw simulated image and R(2) = 0.65 for the envelope-detected ultrasound image. R(2) was highly dependent on microsphere concentration, with values of up to 0.99 for regions with scatterers. The results validate the use of the shift-invariant convolution model for the realistic simulation of ultrasound images. However, care needs to be taken in experiments to reduce the relative effects of other sources of scattering such as from multiple reflections, either by increasing the concentration of imaged scatterers or by more careful experimental design.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...