Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Comput Biol Med ; 178: 108627, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38850959

RESUMEN

Cardiac resynchronization therapy (CRT) can lead to marked symptom reduction and improved survival in selected patients with heart failure with reduced ejection fraction (HFrEF); however, many candidates for CRT based on clinical guidelines do not have a favorable response. A better way to identify patients expected to benefit from CRT that applies machine learning to accessible and cost-effective diagnostic tools such as the 12-lead electrocardiogram (ECG) could have a major impact on clinical care in HFrEF by helping providers personalize treatment strategies and avoid delays in initiation of other potentially beneficial treatments. This study addresses this need by demonstrating that a novel approach to ECG waveform analysis using functional principal component decomposition (FPCD) performs better than measures that require manual ECG analysis with the human eye and also at least as well as a previously validated but more expensive approach based on cardiac magnetic resonance (CMR). Analyses are based on five-fold cross validation of areas under the curve (AUCs) for CRT response and survival time after the CRT implant using Cox proportional hazards regression with stratification of groups using a Gaussian mixture model approach. Furthermore, FPCD and CMR predictors are shown to be independent, which demonstrates that the FPCD electrical findings and the CMR mechanical findings together provide a synergistic model for response and survival after CRT. In summary, this study provides a highly effective approach to prognostication after CRT in HFrEF using an accessible and inexpensive diagnostic test with a major expected impact on personalization of therapies.

2.
J Cardiovasc Dev Dis ; 10(10)2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37887856

RESUMEN

As the mechanism for worse prognosis after cardiac resynchronization therapy (CRT) upgrades in heart failure patients with RVP dependence (RVP-HF) has clinical implications for patient selection and CRT implementation approaches, this study's objective was to evaluate prognostic implications of cardiac magnetic resonance (CMR) findings and clinical factors in 102 HF patients (23.5% female, median age 66.5 years old, median follow-up 4.8 years) with and without RVP dependence undergoing upgrade and de novo CRT implants. Compared with other CRT groups, RVP-HF patients had decreased survival (p = 0.02), more anterior late-activated LV pacing sites (p = 0.002) by CMR, more atrial fibrillation (p = 0.0006), and higher creatinine (0.002). CMR activation timing at the LV pacing site predicted post-CRT LV functional improvement (p < 0.05), and mechanical activation onset < 34 ms by CMR at the LVP site was associated with decreased post-CRT survival in a model with higher pre-CRT creatinine and B-type natriuretic peptide (AUC 0.89; p < 0.0001); however, only the higher pre-CRT creatinine partially mediated (37%) the decreased survival in RVP-HF patients. In conclusion, RVP-HF had a distinct CMR phenotype, which has important implications for the selection of LV pacing sites in CRT upgrades, and only chronic kidney disease mediated the decreased survival after CRT in RVP-HF.

3.
J Cardiovasc Transl Res ; 16(6): 1448-1460, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37674046

RESUMEN

The aim was to test the hypothesis that left ventricular (LV) and right ventricular (RV) activation from body surface electrical mapping (CardioInsight 252-electrode vest, Medtronic) identifies optimal cardiac resynchronization therapy (CRT) pacing strategies and outcomes in 30 patients. The LV80, RV80, and BIV80 were defined as the times to 80% LV, RV, or biventricular electrical activation. Smaller differences in the LV80 and RV80 (|LV80-RV80|) with synchronized LV pacing predicted better LV function post-CRT (p = 0.0004) than the LV-paced QRS duration (p = 0.32). Likewise, a lower RV80 was associated with a better pre-CRT RV ejection fraction by CMR (r = - 0.40, p = 0.04) and predicted post-CRT improvements in myocardial oxygen uptake (p = 0.01) better than the biventricular-paced QRS (p = 0.38), while a lower LV80 with BIV pacing predicted lower post-CRT B-type natriuretic peptide (BNP) (p = 0.02). RV pacing improved LV function with smaller |LV80-RV80| (p = 0.009). In conclusion, 3-D electrical mapping predicted favorable post-CRT outcomes and informed effective pacing strategies.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Dispositivos de Terapia de Resincronización Cardíaca , Ventrículos Cardíacos
4.
Ann Card Anaesth ; 26(3): 346-348, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37470539

RESUMEN

Ellis-Van Creveld syndrome (EVC), also known as mesoectodermal dysplasia, is a rare autosomal recessive disorder with a tetrad of clinical features, comprising dwarfism, polydactyly, ectodermal dysplasia with sparse hair, hypoplastic nails and enamel, hypodontia and conical teeth and congenital heart disease (CHD). We report an 18-year-old girl with short stature and polydactyly, who got admitted to our hospital with shortness of breath on exertion for the last 2 years. On echocardiography, a partial atrioventricular canal (AV canal) defect was diagnosed, which was repaired surgically. The patient had an uneventful perioperative period.


Asunto(s)
Anestésicos , Síndrome de Ellis-Van Creveld , Cardiopatías Congénitas , Polidactilia , Femenino , Humanos , Adolescente , Síndrome de Ellis-Van Creveld/complicaciones , Síndrome de Ellis-Van Creveld/diagnóstico por imagen , Síndrome de Ellis-Van Creveld/cirugía , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía
6.
Heart Rhythm O2 ; 4(2): 79-87, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36873311

RESUMEN

Background: A screening tool to predict response to cardiac resynchronization therapy (CRT) could improve patient selection and outcomes. Objective: The purpose of this study was to investigate the feasibility and safety of noninvasive CRT via transcutaneous ultrasonic left ventricular (LV) pacing applied as a screening test before CRT implants. Methods: P-wave-triggered ultrasound stimuli were delivered during bolus dosing of an echocardiographic contrast agent to simulate CRT noninvasively. Ultrasound pacing was delivered at a variety of LV locations with a range of atrioventricular delays to achieve fusion with intrinsic ventricular activation. Three-dimensional cardiac activation maps were acquired via the Medtronic CardioInsight 252-electrode mapping vest during baseline, ultrasound pacing, and after CRT implantation. A separate control group received only the CRT implants. Results: Ultrasound pacing was achieved in 10 patients with a mean of 81.2 ± 50.8 ultrasound paced beats per patient and up to 20 consecutive beats of ultrasound pacing. QRS width at baseline (168.2 ± 17.8 ms) decreased significantly to 117.3 ± 21.5 ms (P <.001) in the best ultrasound paced beat and to 125.8 ± 13.3 ms (P <.001) in the best CRT beat. Electrical activation patterns were similar between CRT pacing and ultrasound pacing with stimulation from the same area of the LV. Troponin results were similar between the ultrasound pacing and the control groups (P = .96), confirming safety. Conclusion: Noninvasive ultrasound pacing before CRT is safe and feasible, and it estimates the degree of electrical resynchronization achievable with CRT. Further study of this promising technique to guide CRT patient selection is warranted.

7.
Heart Rhythm O2 ; 3(5): 542-552, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36340495

RESUMEN

Background: Cardiac resynchronization therapy (CRT) response is complex, and better approaches are required to predict survival and need for advanced therapies. Objective: The objective was to use machine learning to characterize multidimensional CRT response and its relationship with long-term survival. Methods: Associations of 39 baseline features (including cardiac magnetic resonance [CMR] findings and clinical parameters such as glomerular filtration rate [GFR]) with a multidimensional CRT response vector (consisting of post-CRT left ventricular end-systolic volume index [LVESVI] fractional change, post-CRT B-type natriuretic peptide, and change in peak VO2) were evaluated. Machine learning generated response clusters, and cross-validation assessed associations of clusters with 4-year survival. Results: Among 200 patients (median age 67.4 years, 27.0% women) with CRT and CMR, associations with more than 1 response parameter were noted for the CMR CURE-SVD dyssynchrony parameter (associated with post-CRT brain natriuretic peptide [BNP] and LVESVI fractional change) and GFR (associated with peak VO2 and post-CRT BNP). Machine learning defined 3 response clusters: cluster 1 (n = 123, 90.2% survival [best]), cluster 2 (n = 45, 60.0% survival [intermediate]), and cluster 3 (n = 32, 34.4% survival [worst]). Adding the 6-month response cluster to baseline features improved the area under the receiver operating characteristic curve for 4-year survival from 0.78 to 0.86 (P = .02). A web-based application was developed for cluster determination in future patients. Conclusion: Machine learning characterizes distinct CRT response clusters influenced by CMR features, kidney function, and other factors. These clusters have a strong and additive influence on long-term survival relative to baseline features.

8.
Front Cardiovasc Med ; 9: 1007806, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36186999

RESUMEN

Background: Mechanisms of sex-based differences in outcomes following cardiac resynchronization therapy (CRT) are poorly understood. Objective: To use cardiac magnetic resonance (CMR) to define mechanisms of sex-based differences in outcomes after CRT and describe distinct CMR-based phenotypes of CRT candidates based on sex and non-ischemic/ischemic cardiomyopathy type. Materials and methods: In a prospective study, sex-based differences in three short-term CRT response measures [fractional change in left ventricular end-systolic volume index 6 months after CRT (LVESVI-FC), B-type natriuretic peptide (BNP) 6 months after CRT, change in peak VO2 6 months after CRT], and long-term survival were evaluated with respect to 39 baseline parameters from CMR, exercise testing, laboratory testing, electrocardiograms, comorbid conditions, and other sources. CMR was also used to quantify the degree of left-ventricular mechanical dyssynchrony by deriving the circumferential uniformity ratio estimate (CURE-SVD) parameter from displacement encoding with stimulated echoes (DENSE) strain imaging. Statistical methods included multivariable linear regression with evaluation of interaction effects associated with sex and cardiomyopathy type (ischemic and non-ischemic cardiomyopathy) and survival analysis. Results: Among 200 patients, the 54 female patients (27%) pre-CRT had a smaller CMR-based LVEDVI (p = 0.04), more mechanical dyssynchrony based on the validated CMR CURE-SVD parameter (p = 0.04), a lower frequency of both late gadolinium enhancement (LGE) and ischemic cardiomyopathy (p < 0.0001), a greater RVEF (p = 0.02), and a greater frequency of LBBB (p = 0.01). After categorization of patients into four groups based on cardiomyopathy type (ischemic/non-ischemic cardiomyopathy) and sex, female patients with non-ischemic cardiomyopathy had the lowest CURE-SVD (p = 0.003), the lowest pre-CRT BNP levels (p = 0.01), the lowest post-CRT BNP levels (p = 0.05), and the most favorable LVESVI-FC (p = 0.001). Overall, female patients had better 3-year survival before adjustment for cardiomyopathy type (p = 0.007, HR = 0.45) and after adjustment for cardiomyopathy type (p = 0.009, HR = 0.67). Conclusion: CMR identifies distinct phenotypes of female CRT patients with non-ischemic and ischemic cardiomyopathy relative to male patients stratified by cardiomyopathy type. The more favorable short-term response and long-term survival outcomes in female heart failure patients with CRT were associated with lower indexed CMR-based LV volumes, decreased presence of scar associated with prior myocardial infarction and ICM, and greater CMR-based dyssynchrony with the CURE-SVD.

9.
J Innov Card Rhythm Manag ; 13(3): 4908-4914, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35317206

RESUMEN

The aim of this study was to determine the relationship between ischemia testing prior to ablation for sustained monomorphic ventricular tachycardia (VT) (SMVT) and post-ablation mortality and VT recurrence. As SMVT is generally caused by myocardial scar and not active ischemia, the utility of ischemia testing prior to SMVT ablation is unclear. Patients who underwent ablation for SMVT at 2 tertiary care centers between January 2016 and July 2018 were included in a retrospective study. A Kaplan-Meier survival analysis was performed, stratifying patients by pre-ablation ischemia testing for the endpoints of mortality and VT recurrence. A Cox multivariable regression analysis was performed to identify predictors of post-ablation VT recurrence. A total of 163 patients were included, with 46 (28%) patients undergoing ischemia testing prior to ablation. Only 5 of the 46 patients (11%) received revascularization pre-ablation. After a median follow-up period of 625 days (interquartile range, 292-982 days) following ablation, 97 of 163 patients (60%) had VT recurrence, and 32 patients (20%) had died. There was no difference in mortality or VT recurrence between patients who did or did not experience ischemia testing or revascularization. In the multivariable regression analysis, predictors of VT recurrence were the number of anti-arrhythmics failed, non-ischemic cardiomyopathy, sex, and cardiac magnetic resonance imaging pre-ablation. Neither ischemia testing nor revascularization was a significant predictor of VT recurrence in univariable or multivariable regression analysis. In conclusion, ischemia testing is frequently ordered prior to SMVT ablation but infrequently leads to revascularization and is not associated with post-ablation outcomes. The findings support adopting an individualized approach rather than performing routine ischemia testing.

10.
Pacing Clin Electrophysiol ; 45(4): 491-498, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35174901

RESUMEN

BACKGROUND: An important complication of cardiac implantable electronic devices (CIED) implantation is the development of hematoma and device infection. OBJECTIVE: We aimed to evaluate a novel mechanical compression device for hematoma prevention and cosmetic outcomes following CIED implantation. METHODS: An open, prospective, randomized, single-center clinical trial was performed in patients undergoing CIED implantation. Patients were randomized to receive a novel mechanical compression device (PressRite, PR) or to receive the standard of care post device implantation. Skin pliability was measured with a calibrated durometer; the surgical site was evaluated using the Manchester Scar Scale (MSS) by a blinded plastic surgeon and the Patient and Observer Scar Scale (POSAS). Performance of PR was assessed through pressure measurements, standardized scar scales and tolerability. RESULTS: From the total of 114 patients evaluated for enrollment, 105 patients were eligible for analysis. Fifty-one patients were randomized to management group (PR) and 54 to the control group. No patients required early removal or experienced adverse effects from PR application. There were 11 hematomas (14.8% vs. 5.9% in the control and PR group respectively, p = NS). The control group had higher post procedure durometer readings in the surgical site when compared with the PR group (7.50 ± 3.45 vs. 5.37 ± 2.78; p = < .01). There were lower MSS scores in the PR group after 2 weeks (p = .03). CONCLUSION: We have demonstrated the safety of PR application and removal. In addition, PR appears to improve postoperative skin pliability, which could facilitate wound healing.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Electrónica , Hematoma/etiología , Hematoma/prevención & control , Humanos , Marcapaso Artificial/efectos adversos , Estudios Prospectivos
12.
JACC Cardiovasc Imaging ; 14(12): 2369-2383, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34419391

RESUMEN

OBJECTIVES: The objective was to determine the feasibility and effectiveness of cardiac magnetic resonance (CMR) cine and strain imaging before and after cardiac resynchronization therapy (CRT) for assessment of response and the optimal resynchronization pacing strategy. BACKGROUND: CMR with cardiac implantable electronic devices can safely provide high-quality right ventricular/left ventricular (LV) ejection fraction (RVEF/LVEF) assessments and strain. METHODS: CMR with cine imaging, displacement encoding with stimulated echoes for the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) dyssynchrony parameter, and scar assessment was performed before and after CRT. Whereas the pre-CRT scan constituted a single "imaging set" with complete volumetric, strain, and scar imaging, multiple imaging sets with complete strain and volumetric data were obtained during the post-CRT scan for biventricular pacing (BIVP), LV pacing (LVP), and asynchronous atrial pacing modes by reprogramming the device outside the scanner between imaging sets. RESULTS: 100 CMRs with a total of 162 imaging sets were performed in 50 patients (median age 70 years [IQR: 50-86 years]; 48% female). Reduction in LV end-diastolic volumes (P = 0.002) independent of CRT pacing were more prominent than corresponding reductions in right ventricular end-diastolic volumes (P = 0.16). A clear dependence of the optimal CRT pacing mode (BIVP vs LVP) on the PR interval (P = 0.0006) was demonstrated. The LVEF and RVEF improved more with BIVP than LVP with PR intervals ≥240 milliseconds (P = 0.025 and P = 0.002, respectively); the optimal mode (BIVP vs LVP) was variable with PR intervals <240 milliseconds. A lower pre-CRT displacement encoding with stimulated echoes (DENSE) CURE-SVD was associated with greater improvements in the post-CRT CURE-SVD (r = -0.69; P < 0.001), LV end-systolic volume (r = -0.58; P < 0.001), and LVEF (r = -0.52; P < 0.001). CONCLUSIONS: CMR evaluation with assessment of multiple pacing modes during a single scan after CRT is feasible and provides useful information for patient care with respect to response and the optimal pacing strategy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Valor Predictivo de las Pruebas , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
13.
Pulm Circ ; 11(1): 2045894021992678, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34104416

RESUMEN

Acute pulmonary thromboembolism is associated with high mortality, similar to that of myocardial infarction and stroke. We studied the clinical presentation and management of pulmonary thromboembolism in the Indian population. An analysis of 140 patients who presented with acute pulmonary thromboembolism at a large volume center in India from June 2015 through December 2018 was performed. The mean age of our study population was 50 years with 59% being male. Comorbidities including deep vein thrombosis, diabetes mellitus, hypertension, and chronic obstructive pulmonary disease were present in 52.9%, 40%, 35.7% and 7.14% of patients, respectively. Out of 140 patients, 40 (28.6%) patients had massive pulmonary thromboembolism, 36 (25.7%) sub-massive pulmonary thromboembolism, and 64 (45.7%) had low-risk pulmonary thromboembolism. Overall, in-hospital mortality was 25.7%. Multivariate regression analysis found chronic kidney disease and pulmonary thromboembolism severity to be the only independent risk factors. Thrombolysis was performed in 62.5% of patients with a massive pulmonary thromboembolism and 63.9% of patients with a sub-massive pulmonary thromboembolism. In the massive pulmonary thromboembolism group, patients receiving thrombolytic therapy had lower mortality compared with patients who did not receive therapy (p=0.022), whereas this difference was not observed in patients in the sub-massive pulmonary thromboembolism group. We conclude that patients with acute pulmonary thromboembolism in India presented more than a decade earlier than our western counterparts, and it was associated with poor clinical outcomes. Thrombolysis was associated with significantly reduced in-hospital mortality in patients with massive pulmonary thromboembolism.

14.
J Arrhythm ; 37(2): 400-406, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33850582

RESUMEN

AIMS: Dermatologic evaluation for cardiac implantable electronic devices (CIEDs) has not been established. We sought to ascertain baseline wound scar features using quantifiable surgical tools and scar scales on post-CIED patients. METHODS: A single-center, prospective observational case-control study was performed where 92 study subjects (40 healthy volunteers and 52 post-CIED patients) completed the study. Durometer was used to quantify skin pliability before CIED placement, postprocedure, and 2 weeks postprocedure. Higher durometer readings signified reduced skin pliability. Durometer readings were compared to the patients' contralateral pectoral skin and to a healthy volunteer's cohort skin within the prepectoral region. Patient wounds were observed and graded using the Patient Observer Scar Assessment Scale (POSAS) and Manchester Scar Scale (MSS). RESULTS: Baseline pectoral skin pliability readings were similar in healthy volunteers and CIED patient population. In comparison to preprocedural measurements, surgical site skin pliability decreased in postprocedural and 2 weeks follow-up time points (P-value .004 and <.001, respectively). The increases in durometer readings were higher in the older population (age >75 over time, P = .008). POSAS evaluations showed on average a thin painless hypopigmented scar with moderate stiffness. MSS scar evaluation showed a palpable scar with slight contour differences and color mismatch and appeared to be slightly better in the African American population. There was no difference in scar characteristics with preprocedural use of antiplatelet or anticoagulation or staple closure or gender. CONCLUSIONS: Serial measurements could be of value for development of new strategies for cosmesis and improved wound healing.

15.
Am J Cardiol ; 148: 165-171, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33667437

RESUMEN

Peripheral artery disease (PAD) remains a major cause of morbidity and future cardiovascular events despite advancement in the surgical interventions and optimal medical therapy. The aim of our study is to evaluate the efficacy and safety of anticoagulation (AC) therapy for reducing cardiovascular and limb events in patients with PAD. PUBMED, Medline, and Cochrane Library were searched through 2020 for randomized clinical trials comparing major adverse cardiovascular events (MACE) and risk of major bleeding (MB), between AC and standard of care (SOC) therapy, among patients with PAD. Meta-analysis was performed using weighted pooled absolute risk difference (RD) with 95% confidence interval (CI) and fixed effects model for overall and sub-groups of full dose (FD) and low dose (LD) AC therapies. Amongst 17,684 patients from 7 different studies, the addition of AC to SOC therapy was associated with MACE reduction (RD -0.022, 95% CI -0.033 to -0.012, p <0.001) and increased MB (RD 0.02, 95% CI 0.014 to 0.025, p <0.001). For FD, MACE reduction was (RD -0.021, 95% CI -0.042 to 0.001, p = 0.061) and MB (RD 0.036, 95% CI 0.025 to 0.047, p <0.001). For LD, MACE reduction was (RD -0.023, 95% CI -0.035 to -0.011, p <0.001) and MB (RD 0.011, 95% CI 0.005 to 0.017, p <0.001). In conclusion, addition of AC to the current SOC therapy can mitigate future MACE events in patients with PAD albeit at risk of increased bleeding. LD AC is associated with an efficacy/safety net benefit compared to FD AC therapy.


Asunto(s)
Amputación Quirúrgica/estadística & datos numéricos , Anticoagulantes/uso terapéutico , Hemorragia/epidemiología , Infarto del Miocardio/epidemiología , Enfermedad Arterial Periférica/tratamiento farmacológico , Accidente Cerebrovascular/epidemiología , Procedimientos Quirúrgicos Vasculares/estadística & datos numéricos , Enfermedades Cardiovasculares/mortalidad , Hemorragia/inducido químicamente , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto
16.
Acad Radiol ; 28(12): 1669-1674, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-32972842

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) procedural success relies heavily on volumetric reconstruction imaging, particularly ECG-gated multi-detector row computed tomography. We postulated that single examination using fast low-angle shot (FLASH) dual source CT scanning (DS-CTA) could provide lower dose than ECG-gated CTA while maintaining the image quality. METHODS: In this single-centre cohort study, all patients who underwent ECG-gated and FLASH DS-CTA were evaluated. Volumetric reconstructions were performed for both ECG-gated and FLASH DS-CTA to obtain nonsagittal views of the structures. ECG-gated cardiac CT was obtained to evaluate the aortic annular size while FLASH DS-CTA was obtained to examine the aortic and iliac vasculature as part of TAVR imaging protocol. We evaluated measures of aortic annulus, coronaries and sinus of Valsalva using ECG-gated and FLASH DS-CTA scanning protocols. Image quality assessments were performed using aortic root region-of-interest signal-to-noise ratio. RESULTS: A total of 130 patients (mean age 81.5 ± 9.2 years, 46.2% female, and 99.2% white) underwent both ECG-gated CT and FLASH DS-CTA. There were excellent correlations between aortic annular area (R2 = 0.934) and aortic annular perimeter (R2 = 0.923) measured by the two protocols. Only 2 (1.5%) patients had >10% difference between aortic annular measurements by ECG-gated and FLASH DS-CTA, while none of the patients had a >10% difference between aortic annular perimeter measured by ECG-gated and FLASH DS-CT scans. There was no significant difference in signal-to-noise ratio between the two methods (mean difference 13.4; 95% CI -2.1-28.8, p = 0.09). There was significantly lower radiation dose for FLASH DS-CTA than ECG-gated CT scan (mean dose-length product difference 404.38; 95% CI 328.9-479.87, p <0.001). The measurements by the two scans led to the same transcatheter valve size selection in majority of the 128 (98.5%) patients by balloon expandable valve sizing recommendations and 130 (100%) of patients by self-expanding valve sizing recommendations. CONCLUSION: Overall, FLASH DS-CTA and ECG-gated CT scans provided comparable image quality and aortic annular dimensions for pre-TAVR evaluation. DS-CTA additionally provided the necessary angiographic imaging of the aorta and peripheral access vessels while still maintaining a lower radiation dose. We propose that a single non-ECG gated FLASH DS-CTA could be utilized to provide all the necessary pre-TAVR imaging information without a gated CT scan.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Angiografía por Tomografía Computarizada , Electrocardiografía , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector
17.
J Anaesthesiol Clin Pharmacol ; 36(2): 219-226, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33013038

RESUMEN

BACKGROUND AND AIMS: Rising health costs are challenging anesthesiologists to search for cost-effective anesthetic techniques. We conducted a study to estimate variable cost per case and cost of drug wastage as percentage of total drug cost associated with different modalities of general anesthesia (GA). MATERIAL AND METHODS: This prospective study was carried out after approval by institutional ethical committee in 258 adult patients aged 18-60 years of either sex, American Society of Anesthesiologists physical status I or II, with a surgical duration of 1-4 hours, posted for elective surgery under GA with endotracheal intubation. At the end of surgery, total utilization of each drug, anesthetic gases, and consumables were noted and remaining drug was regarded as wastage. Cost was recorded as per maximum retail price for that particular brand in the market at start of study and total cost was calculated. For purpose of analysis, cases were divided into low flow sevoflurane, high flow sevoflurane, high flow isoflurane, low flow isoflurane, and total intravenous anesthesia (TIVA). RESULTS: The mean variable cost was highest with TIVA (₹2713.82 ± 509.57) and lowest with low flow isoflurane (₹1981.62 ± 335.03; P < 0.001). Drug wastage was 13.1% overall, with highest in low sevoflurane group and lowest in TIVA. CONCLUSION: Low flow anesthesia with isoflurane is more cost-effective as compared to high flow techniques and TIVA even for short duration surgeries. Rational use of drugs and consumables and minimizing wastage can further reduce anesthesia costs.

18.
Cardiol Ther ; 9(2): 553-559, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32683639

RESUMEN

INTRODUCTION: Numerous case series have reported on the baseline characteristics and in-hospital mortality of patients with COVID-19, however, these studies included patients localized in a specific geographic region. The purpose of our study was to identify differences in the clinical characteristics and the in-hospital mortality of patients with a laboratory-confirmed diagnosis of COVID-19 internationally. METHODS: A comprehensive search of all published literature on adult patients with laboratory-confirmed diagnosis of COVID-19 that reported on the clinical characteristics and in-hospital mortality was performed. Groups were compared using a Chi-square test with Yates correction of continuity. A two-tailed p value of less than 0.05 was considered as statistically significant. RESULTS: After screening 516 studies across the globe, 43 studies from 12 countries were included in our final analysis. Patients with COVID-19 in America and Europe were older compared to their Asian counterparts. Europe had the highest percentage of male patients. American and European patients had a higher incidence of co-morbid conditions (p < 0.05 for all variables). In-hospital mortality was significantly higher in America (22.23%) and Europe (22.9%) compared to Asia (12.65%) (p < 0.0001), but no difference was seen when compared with each other (p = 0.49). CONCLUSIONS: There is a significant variation in the clinical characteristics in patients diagnosed with COVID-19 across the globe. In-hospital mortality is similar between America and Europe, but considerably higher than Asia.

19.
JACC Cardiovasc Imaging ; 13(4): 924-936, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31864974

RESUMEN

OBJECTIVES: This study sought to determine if combining the Seattle Heart Failure Model (SHFM-D) and cardiac magnetic resonance (CMR) provides complementary prognostic data for patients with cardiac resynchronization therapy (CRT) defibrillators. BACKGROUND: The SHFM-D is among the most widely used risk stratification models for overall survival in patients with heart failure and implantable cardioverter-defibrillators (ICDs), and CMR provides highly detailed information regarding cardiac structure and function. METHODS: CMR Displacement Encoding with Stimulated Echoes (DENSE) strain imaging was used to generate the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) circumferential strain dyssynchrony parameter, and the SHFM-D was determined from clinical parameters. Multivariable Cox proportional hazards regression was used to determine adjusted hazard ratios and time-dependent areas under the curve for the primary endpoint of death, heart transplantation, left ventricular assist device, or appropriate ICD therapies. RESULTS: The cohort consisted of 100 patients (65.5 [interquartile range 57.7 to 72.7] years; 29% female), of whom 47% had the primary clinical endpoint and 18% had appropriate ICD therapies during a median follow-up of 5.3 years. CURE-SVD and the SHFM-D were independently associated with the primary endpoint (SHFM-D: hazard ratio: 1.47/SD; 95% confidence interval: 1.06 to 2.03; p = 0.02) (CURE-SVD: hazard ratio: 1.54/SD; 95% confidence interval: 1.12 to 2.11; p = 0.009). Furthermore, a favorable prognostic group (Group A, with CURE-SVD <0.60 and SHFM-D <0.70) comprising approximately one-third of the patients had a very low rate of appropriate ICD therapies (1.5% per year) and a greater (90%) 4-year survival compared with Group B (CURE-SVD ≥0.60 or SHFM-D ≥0.70) patients (p = 0.02). CURE-SVD with DENSE had a stronger correlation with CRT response (r = -0.57; p < 0.0001) than CURE-SVD with feature tracking (r = -0.28; p = 0.004). CONCLUSIONS: A combined approach to risk stratification using CMR DENSE strain imaging and a widely used clinical risk model, the SHFM-D, proved to be effective in this cohort of patients referred for CRT defibrillators. The combined use of CMR and clinical risk models represents a promising and novel paradigm to inform prognosis and device selection in the future.


Asunto(s)
Arritmias Cardíacas/prevención & control , Terapia de Resincronización Cardíaca , Técnicas de Apoyo para la Decisión , Cardioversión Eléctrica , Insuficiencia Cardíaca/terapia , Imagen por Resonancia Cinemagnética , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 21(4): 453-460, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31669113

RESUMEN

BACKGROUND: TAVR is an established treatment option in high and intermediate-risk patients with severe AS. There is less data regarding the efficacy of TAVR in low-risk patients. This meta-analysis evaluated efficacy and safety outcomes of transcatheter aortic valve replacement (TAVR) in comparison to surgical aortic valve replacement (SAVR) in low-risk patients with severe aortic stenosis (AS). METHODS: Databases were searched for randomized controlled trials (RCTs) that compared TAVR with SAVR for the treatment of low-risk patients with severe AS. We calculated pooled odds ratios (ORs) and 95% confidence intervals (CIs) using the random-effects model. RESULTS: The final analysis included 2953 patients from 5 studies. Compared to SAVR, TAVR was associated with similar mid-term mortality [OR 0.67; 95% CI 0.37-1.21; p = 0.18], as well as similar short-term mortality [OR 0.51; 95% CI 0.24-1.11; p = 0.09]. Randomization to TAVR was associated with a reduced risk of developing acute kidney injury [OR 0.26; 95% CI 0.13-0.52; p < 0.001], short-term major bleeding [OR 0.27; 95% CI 0.12-0.60; p < 0.001] and new-onset atrial fibrillation [OR 0.17; 95% CI 0.14-0.21; p < 0.001]. However, TAVR was associated with a higher risk of requiring permanent pacemaker implantation [OR 4.25; 95% CI 1.86-9.73; p < 0.001]. There was no significant difference in the risk of myocardial infarction, stroke, endocarditis or aortic valve re-intervention between the two groups. CONCLUSIONS: Our meta-analysis showed that TAVR has similar clinical efficacy to SAVR, with a more favorable safety profile, in patients with severe AS who are at low-surgical risk.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Toma de Decisiones Clínicas , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Selección de Paciente , Complicaciones Posoperatorias/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...