Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Commun Biol ; 7(1): 677, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38830977

RESUMEN

We present a quantitative sandwich immunoassay for CD63 Extracellular Vesicles (EVs) and a constituent surface cargo, EGFR and its activity state, that provides a sensitive, selective, fluorophore-free and rapid alternative to current EV-based diagnostic methods. Our sensing design utilizes a charge-gating strategy, with a hydrophilic anion exchange membrane functionalized with capture antibodies and a charged silica nanoparticle reporter functionalized with detection antibodies. With sensitivity and robustness enhancement by the ion-depletion action of the membrane, this hydrophilic design with charged reporters minimizes interference from dispersed proteins, thus enabling direct plasma analysis without the need for EV isolation or sensor blocking. With a LOD of 30 EVs/µL and a high relative sensitivity of 0.01% for targeted proteomic subfractions, our assay enables accurate quantification of the EV marker, CD63, with colocalized EGFR by an operator/sample insensitive universal normalized calibration. We analysed untreated clinical samples of Glioblastoma to demonstrate this new platform. Notably, we target both total and "active" EGFR on EVs; with a monoclonal antibody mAb806 that recognizes a normally hidden epitope on overexpressed or mutant variant III EGFR. Analysis of samples yielded an area-under-the-curve (AUC) value of 0.99 and a low p-value of 0.000033, surpassing the performance of existing assays and markers.


Asunto(s)
Receptores ErbB , Vesículas Extracelulares , Glioblastoma , Tetraspanina 30 , Humanos , Glioblastoma/sangre , Glioblastoma/diagnóstico , Glioblastoma/metabolismo , Tetraspanina 30/metabolismo , Receptores ErbB/metabolismo , Vesículas Extracelulares/metabolismo , Inmunoensayo/métodos , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/metabolismo , Neoplasias Encefálicas/sangre , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/diagnóstico
2.
bioRxiv ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37905113

RESUMEN

We present a novel quantitative immunoassay for CD63 EVs (extracellular vesicles) and a constituent surface cargo, EGFR and its activity state, that provides a sensitive, selective, fluorophore-free and rapid alternative to current EV-based diagnostic methods. Our sensing design utilizes a charge-gating strategy, with a hydrophilic anion exchange membrane and a charged silica nanoparticle reporter. With sensitivity and robustness enhancement by the ion-depletion action of the membrane, this hydrophilic design with charged reporters minimizes interference from dispersed proteins and fluorophore degradation, thus enabling direct plasma analysis. With a limit of detection of 30 EVs/µL and a high relative sensitivity of 0.01% for targeted proteomic subfractions, our assay enables accurate quantification of the EV marker, CD63, with colocalized EGFR by an operator/sample insensitive universal normalized calibration. Glioblastoma necessitates improved non-invasive diagnostic approaches for early detection and monitoring. Notably, we target both total and "active" EGFR on EVs; with a monoclonal antibody mAb806 that recognizes a normally hidden epitope on overexpressed or mutant variant III EGFR. This approach offers direct glioblastoma detection from untreated human patient samples. Analysis of glioblastoma clinical samples yielded an area-under-the-curve (AUC) value of 0.99 and low p-value of 0.000033, significantly surpassing the performance of existing assays and markers.

3.
Nat Commun ; 14(1): 557, 2023 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-36732521

RESUMEN

Cardiovascular disease-related deaths (one-third of global deaths) can be reduced with a simple screening test for better biomarkers than the current lipid and lipoprotein profiles. We propose using a highly atheroprotective subset of HDL with colocalized PON1 (PON1-HDL) for superior cardiovascular risk assessment. However, direct quantification of HDL proteomic subclasses are complicated by the peroxides/antioxidants associated with HDL interfering with redox reactions in enzymatic calorimetric and electrochemical immunoassays. Hence, we developed an enzyme-free Nanoparticle-Gated Electrokinetic Membrane Sensor (NGEMS) platform for quantification of PON1-HDL in plasma within 60 min, with a sub-picomolar limit of detection, 3-4 log dynamic range and without needing sample pretreatment or individual-sample calibration. Using NGEMS, we report our study on human plasma PON1-HDL as a cardiovascular risk marker with AUC~0.99 significantly outperforming others (AUC~0.6-0.8), including cholesterol/triglycerides tests. Validation for a larger cohort can establish PON1-HDL as a biomarker that can potentially reshape cardiovascular landscape.


Asunto(s)
Enfermedades Cardiovasculares , Humanos , Enfermedades Cardiovasculares/diagnóstico , Proteómica , Factores de Riesgo , Lipoproteínas , Factores de Riesgo de Enfermedad Cardiaca , Arildialquilfosfatasa , HDL-Colesterol
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA