RESUMEN
Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable cardioverter-defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Objective: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th-75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P = .045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusion: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.
RESUMEN
AIMS: We report the results of a real-world study based on heart failure (HF) patients' continuous remote monitoring strategy using the CardioMEMS system to assess the impact of this device on healthcare outcomes, costs, and patients' management and quality of life. METHODS AND RESULTS: We enrolled seven patients (69.00 ± 4.88 years; 71.43% men) with HF, implanted with CardioMEMS, and daily remote monitored to optimize both tailored adjustments of home therapy and/or hospital infusions of levosimendan. We recorded clinical, pharmacological, biochemical, and echocardiographic parameters and data on hospitalizations, emergency room access, visits, and costs. Following the implantation of CardioMEMS, we observed a 50% reduction in the total number of hospitalizations and a 68.7% reduction in the number of days in the hospital. Accordingly, improved patient quality of life was recorded with EQ-5D (pre 58.57 ± 10.29 vs. 1 year post 84.29 ± 19.02, P = 0.008). Echocardiographic data show a statistically significant improvement in both systolic pulmonary artery pressure (47.86 ± 8.67 vs. 35.14 ± 9.34, P = 0.022) and E/e' (19.33 ± 5.04 vs. 12.58 ± 3.53, P = 0.023). The Quantikine® HS High-Sensitivity Kit determined elevated interleukin-6 values at enrolment in all patients, with a statistically significant reduction after 6 months (P = 0.0211). From an economic point of view, the net savings, including the cost of CardioMEMS, were on average 1580 per patient during the entire period of observation, while the analysis performed 12 months after the implant vs. 12 months before showed a net saving of 860 per patient. The ad hoc analysis performed on the levosimendan infusions resulted in 315 days of hospital avoidance and a saving of 205 158 for the seven patients enrolled during the observation period. CONCLUSIONS: This innovative strategy prevents unplanned access to the hospital and contributes to the efficient use of healthcare facilities, human resources, and costs.
Asunto(s)
Cardiotónicos , Insuficiencia Cardíaca , Calidad de Vida , Simendán , Humanos , Simendán/uso terapéutico , Simendán/administración & dosificación , Masculino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Femenino , Anciano , Cardiotónicos/uso terapéutico , Cardiotónicos/administración & dosificación , Estudios de Seguimiento , Resultado del Tratamiento , Hidrazonas/uso terapéutico , Hidrazonas/administración & dosificación , Piridazinas/uso terapéutico , Piridazinas/administración & dosificación , Piridazinas/economía , Persona de Mediana EdadRESUMEN
(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. PURPOSE: To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). METHODS: In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. RESULTS: A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III-IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1-13) to 42.2% (weeks_40-52, p < 0.001). CONCLUSIONS: High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence.
RESUMEN
AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1â h/day and periods with an AHRE burden ≥20â h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1â h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1â h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20â h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1â h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20â h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.
Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Pronóstico , Volumen Sistólico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Arritmias Cardíacas/terapia , Factores de Riesgo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Disfunción Ventricular Izquierda/complicacionesRESUMEN
AIMS: The HeartLogic algorithm combines multiple implantable defibrillator (ICD) sensor data and has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation in cardiac resynchronization therapy (CRT-D) patients. We evaluated the performance of this algorithm in non-CRT ICD patients and in the presence of co-morbidities. METHODS AND RESULTS: The HeartLogic feature was activated in 568 ICD patients (410 with CRT-D) from 26 centres. The median follow-up was 26 months [25th-75th percentile: 16-37]. During follow-up, 97 hospitalizations were reported (53 cardiovascular) and 55 patients died. We recorded 1200 HeartLogic alerts in 370 patients. Overall, the time IN the alert state was 13% of the total observation period. The rate of cardiovascular hospitalizations or death was 0.48/patient-year (95% CI: 0.37-0.60) with the HeartLogic IN the alert state and 0.04/patient-year (95% CI: 0.03-0.05) OUT of the alert state, with an incidence rate ratio of 13.35 (95% CI: 8.83-20.51, P < 0.001). Among patient characteristics, atrial fibrillation (AF) on implantation (HR: 1.62, 95% CI: 1.27-2.07, P < 0.001) and chronic kidney disease (CKD) (HR: 1.53, 95% CI: 1.21-1.93, P < 0.001) independently predicted alerts. HeartLogic alerts were not associated with CRT-D versus ICD implantation (HR: 1.03, 95% CI: 0.82-1.30, P = 0.775). Comparisons of the clinical event rates in the IN alert state with those in the OUT of alert state yielded incidence rate ratios ranging from 9.72 to 14.54 (all P < 0.001) in all groups of patients stratified by: CRT-D/ICD, AF/non-AF, and CKD/non-CKD. After multivariate correction, the occurrence of alerts was associated with cardiovascular hospitalization or death (HR: 1.92, 95% CI: 1.05-3.51, P = 0.036). CONCLUSIONS: The burden of HeartLogic alerts was similar between CRT-D and ICD patients, while patients with AF and CKD seemed more exposed to alerts. Nonetheless, the ability of the HeartLogic algorithm to identify periods of significantly increased risk of clinical events was confirmed, regardless of the type of device and the presence of AF or CKD.
Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/etiología , Algoritmos , MorbilidadRESUMEN
A 70-year-old man presented to the emergency department with accidental gunshot wound at left hemithorax and left shoulder/arm. Initial clinical assessment showed stable vital signs and an implantable cardioverter-defibrillator (ICD) protruding outside from large wound in the infraclavicular region. The ICD, previously implanted for secondary prevention of ventricular tachycardia, appeared burned and the battery was exploded. Urgent chest computed tomography scan was performed with evidence of left humeral fracture without significant arterial injury. The ICD generator was disconnected from passive fixation leads and removed. The patient was stabilized and the humeral fracture was fixed. Then lead extraction was successfully performed in a hybrid operating room with cardiac surgery standby. The patient was discharged in good clinical conditions after reimplantation of a novel ICD in the right infraclavicular region.Emerging technologies are promising in making lead extraction safer and more accessible for patients worldwide. This case report provides the most up-to-date indications and procedural approaches for lead extraction and insights on the future trends in this field.
Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Heridas por Arma de Fuego , Masculino , Humanos , Anciano , Heridas por Arma de Fuego/complicaciones , Explosiones , Arritmias Cardíacas , Taquicardia Ventricular/etiología , Taquicardia Ventricular/prevención & control , Muerte Súbita Cardíaca/prevención & controlRESUMEN
AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.
Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Estudios de Casos y Controles , Muerte Súbita Cardíaca/etiología , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
AIMS: HeartLogic algorithm combines data from multiple implantable defibrillators (ICD)-based sensors to predict impending heart failure (HF) decompensation. A treatment protocol to manage algorithm alerts is not yet known, although decongestive treatment adjustments are the most frequent alert-triggered actions reported in clinical practice. We describe the implementation of HeartLogic for remote monitoring of HF patients, and we evaluate the approach to diuretic dosing and timing of the intervention in patients with device alerts. METHODS: The algorithm was activated in 229 ICD patients at eight centers. The median follow-up was 17 months (25th-75th percentile: 11-24). Remote data reviews and patient phone contacts were undertaken at the time of HeartLogic alerts, to assess the patient's status and to prevent HF worsening. We analyzed alert-triggered augmented HF treatments, consisting of isolated increases in diuretics dosage. RESULTS: We reported 242 alerts (0.8 alerts/patient-year) in 123 patients, 137 (56%) alerts triggered clinical actions to treat HF. The HeartLogic index decreased after the 56 actions consisting of diuretics increase. Specifically, alerts resolved more quickly when the increases in dosing of diuretics were early rather than late: 28 days versus 62 days, p < .001. The need of hospitalization for further treatments to resolve the alert condition was associated with higher HeartLogic index values on the day of the diuretics increase (odds ratio: 1.11, 95% CI: 1.02-1.20, p = .013) and with late interventions (odds ratio: 5.11, 95% CI: 1.09-24.48, p = .041). No complications were reported after drug adjustments. CONCLUSIONS: Decongestive treatment adjustments triggered by alerts seem safe and effective. The early use of decongestive treatment and the use of high doses of diuretics seem to be associated with more favorable outcomes.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Algoritmos , Terapia de Resincronización Cardíaca/métodos , Diuréticos/uso terapéutico , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , HumanosRESUMEN
During the last years, the management of heart failure (HF) made substantial progress, focusing on device-based therapies to meet the demands of this complex syndrome. In this case report, we present a multistep approach to deal with HF. Specifically, we report the first patient subjected to the implantation of both Optimizer Smart® (Impulse Dynamics Inc., Marlton, NJ, USA) and CardioMEMS devices. A 72-year-old male patient with HF and reduced ejection fraction (HFrEF) was admitted to our cardiology department in January 2021, following a progressive shortening of the time between hospitalizations for levosimendan infusions. Specifically, the patient was monitored daily by CardioMEMS, and a strategy of levosimendan infusions guided by the device had been adopted. He was also a carrier of MitraClips and cardiac resynchronization therapy defibrillator (CRT-D) and had optimized HF medical therapy. In January 2021, the patient implanted Optimizer Smart® device for cardiac contractility modulation (CCM) therapy because of poor response to therapy and elevated pulmonary artery pressure (PAP). CCM significantly reduced PAP values following discharge (systolic PAP 33.67 ± 2.92 vs. 40.6 ± 3.37 mmHg, diastolic PAP 14.5 ± 2.01 vs. 22.5 ± 2.53 mmHg, mean PAP 22.87 ± 2.20 vs. 30.9 ± 2.99 mmHg, HR 60.93 ± 1.53 vs. 80.83 ± 3.66 bpm; p < 0.0001), with persisting effect at 9 months. The usefulness of CCM is objectively demonstrated for the first time by continuous invasive monitoring of PAP by CardioMEMS, which can suggest the correct timing for CCM implantation.
RESUMEN
AIMS: The utilization of remote monitoring platforms was recommended amidst the COVID-19 pandemic. The HeartLogic index combines multiple implantable cardioverter defibrillator (ICD) sensors and has proved to be a predictor of impending heart failure (HF) decompensation. We examined how multiple ICD sensors behave in the periods of anticipated restrictions pertaining to physical activity. METHODS: The HeartLogic feature was active in 349 ICD and cardiac resynchronization therapy ICD patients at 20 Italian centers. The period from 1 January to 19 July 2020, was divided into three phases: pre-lockdown (weeks 1-11), lockdown (weeks 12-20), post-lockdown (weeks 21-29). RESULTS: Immediately after the implementation of stay-at-home orders (week 12), we observed a significant drop in median activity level whereas there was no difference in the other contributing parameters. The median composite HeartLogic index increased at the end of the Lockdown. The weekly rate of alerts was significantly higher during the lockdown (1.56 alerts/week/100 pts, 95%CI: 1.15-2.06; IRR = 1.71, p = 0.014) and post-lockdown (1.37 alerts/week/100 pts, 95%CI: 0.99-1.84; IRR = 1.50, p = 0.072) than that reported in pre-lockdown (0.91 alerts/week/100 pts, 95%CI: 0.64-1.27). However, the median duration of alert state and the maximum index value did not change among phases, as well as the proportion of alerts followed by clinical actions at the centers and the proportion of alerts fully managed remotely. CONCLUSIONS: During the lockdown, the system detected a significant drop in the median activity level and generated a higher rate of alerts suggestive of worsening of the HF status.
RESUMEN
PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del TratamientoRESUMEN
OBJECTIVES: This study evaluated the efficacy of conversion test performed at 40 J (defibrillation margin ≥40 J), and factors potentially associated with test failure were identified. BACKGROUND: Current subcutaneous implantable cardioverter-defibrillator (S-ICD) devices deliver a maximum of 80 J. Functional defibrillation testing is recommended at S-ICD implantation, and it is usually conducted by delivering a shock energy of 65 J to ensure a safety defibrillation margin ≥15 J. Although high rates of successful conversion were reported at 65 J, limited data exist on the defibrillation margin extent. METHODS: Ventricular fibrillation was induced and conversion test was performed by delivering a 40-J shock in 308 patients. Success was defined as termination of ventricular fibrillation by the first shock delivered in standard polarity. The S-ICD system positioning was evaluated with the PRAETORIAN score using bidirectional chest X-rays. RESULTS: The generator was positioned in an intermuscular pocket in 301 patients (98%) and the lead was implanted by means of a 2-incision technique. The PRAETORIAN score was <90 (low risk of conversion failure) in 293 (95%) patients. Overall, ventricular fibrillation termination occurred in 259 (84%) patients with 40 J. Male gender (odds ratio [OR]: 3.79; 95% confidence interval [CI]: 1.09 to 13.14; p = 0.036), body mass index (OR: 1.09; 95% CI: 1.01 to 1.19; p = 0.036), dilated cardiomyopathy with reduced ejection fraction (OR: 0.42; 95% CI: 0.20 to 0.87; p = 0.019), and PRAETORIAN score >50 (OR: 2.93; 95% CI: 1.26 to 6.83; p = 0.013) were independently associated with conversion failure. CONCLUSIONS: The authors showed a high rate of defibrillation success with 40-J shocks in S-ICD systems implanted by means of modern surgical techniques. The variables associated with shock failure were male gender, higher body mass index, and suboptimal device position according to the PRAETORIAN score.
Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas , Desfibriladores Implantables/efectos adversos , Humanos , Masculino , Fibrilación Ventricular/terapiaRESUMEN
BACKGROUND: Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact. METHODS: We estimated battery longevity in 167 CRT-D patients based on measured pacing parameters according to multiple alternative programming strategies: single-site pacing associated with lowest threshold, non-apical location, longest interventricular delay, and pacing from two electrodes. To determine the economic impact of each programming strategy, we applied the results of a model-based cost analysis using a 15-year time horizon. RESULTS: Selecting the electrode with the lowest threshold resulted in a median device longevity of 11.5 years. Non-apical pacing and interventricular delay maximization were feasible in most patients and were obtained at the price of a few months of battery life. Device longevity of > 10 years was preserved in 87% of cases of non-apical pacing and in 77% on pacing at the longest interventricular delay. The mean reduction in battery life when the second electrode was activated was 1.5 years. Single-site pacing strategies increased the therapy cost by 4-6%, and multi-site pacing by 12-13%, in comparison with the lowest-cost scenario. CONCLUSIONS: Modern CRT-D systems ensure effective pacing and allow multiple optimization strategies for maximizing service life or for enhancing effectiveness. Single- or multi-site pacing strategies can be implemented without compromising device service life and at an acceptable increase in therapy cost.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Humanos , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.
RESUMEN
OBJECTIVES: This study evaluated the temporal association between atrial high-rate episodes (AHREs) and sustained ventricular arrhythmias (VAs) in a remotely monitored cohort with implantable cardioverter-defibrillators (ICD) with and/or without cardiac resynchronization therapy with a defibrillator (CRT-D). BACKGROUND: Clinical relevance of AHREs in terms of VA rate and survival has not been outlined yet. METHODS: This study analyzed data of patients with ICDs and CRT-Ds from the nationwide Home Monitoring Expert Alliance network. The cohort included 2,435 patients with a median follow-up of 25 months (interquartile range: 13 to 42 months) and age 70 years (range 61 to 77 years); 19.7% were women, 51.4% had coronary artery disease, and 45.2% had a CRT-D. There were 3,410 appropriate VA episodes; 498 (14.6%) were preceded by AHREs within 48 h; in 85.5% of this group, AHREs were still ongoing at episode onset. RESULTS: In a longitudinal analysis, the odds ratios (ORs) of experiencing any VA in a 30-day interval with AHREs versus intervals without AHREs were 2.35 (95% confidence interval [CI]: 1.86 to 2.97; p < 0.001) for ventricular tachycardia (VT), 3.06 (95% CI: 2.35 to 3.99; p < 0.001) for fast VT, 1.84 (95% CI: 1.36 to 2.48; p < 0.001) for self-extinguishing ventricular fibrillation (VF), and 2.31 (95% CI: 1.17 to 4.57; p = 0.01) for VF. ORs decreased with increasing AHRE burden. Patients with AHREs 48 h before VAs were more likely to experience VA recurrences (adjusted hazard ratio [HR]: 1.78; 95% CI: 1.41 to 2.24; p < 0.001) and had higher overall mortality (HR: 2.67; 95% CI: 1.68 to 4.23; p < 0.001). CONCLUSIONS: AHREs were not uncommon 48 h before VAs, which tended to be distributed around intervals with AHREs. Temporal connection between AHREs and VAs was a marker of increased risk of VA recurrence and a poorer prognosis.
Asunto(s)
Fibrilación Atrial/epidemiología , Aleteo Atrial/epidemiología , Mortalidad , Taquicardia Supraventricular/epidemiología , Taquicardia Ventricular/epidemiología , Fibrilación Ventricular/epidemiología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Tecnología de Sensores Remotos , Riesgo , Factores de TiempoRESUMEN
BACKGROUND: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS: The presence of an association between RR and the incidence of AHREs. METHODS: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS: After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.
RESUMEN
INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.
Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Tecnología de Sensores Remotos , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Causas de Muerte , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Falla de Prótesis , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIMS: The benefit of prolonged implantable cardioverter-defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) therapy following device replacement is hindered by clinical and procedure-related adverse events (AEs). Adverse events rate is highest in more complex devices and at upgrades, as per the REPLACE registry experience, but is changing owing to the improvement in device technology and medical care. We aimed at understanding the extent and type of AEs in a contemporary Italian population. METHODS AND RESULTS: Detect long-term complications after ICD replacement (DECODE) was a prospective, single-arm, multicentre cohort study aimed at estimating medium- to long-term AEs in a large population of patients undergoing ICD/cardiac resynchronization defibrillator replacement/upgrade from 2013 to 2015. We prospectively analysed all clinical and device-related AEs at 12-month follow-up (FU) of 983 consecutive patients (median age 71 years, 76% male, 55% ischaemic, 47% CRT-D) followed for 353 ± 49 days. Seven percent of the patients died (60.6% for cardiovascular reasons), whereas 104 AEs occurred; 43 (4.4%) patients needed at least one surgical action to treat the AE. Adverse events rates were 3.3/100 years lead-related, 3.4/100 years bleedings, and 1.6/100 years infective. The primary endpoint was predicted by hospitalization in the month prior to the procedure [hazard ratio (HR) = 2.23, 1.16-4.29; 0.0169] and by upgrade (HR = 1.75, 1.02-2.99, 0.0441). One hundred and twelve (11.4%) patients met the combined endpoint of death from any cause, cardiac implantable electronic device (CIED)-related infection, and surgical action/hospitalization required to treat the AE. Hospitalization within 30 days prior to the procedure (HR = 2.07, 1.13-3.81; 0.0199), anticoagulation (HR = 1.97, 1.26-3.07; 0.003), and ischaemic cardiomyopathy (HR = 1.67, 95% confidence interval 1.06-2.63; P = 0.0276) were associated with the combined endpoint during FU. CONCLUSIONS: Adverse events following CIED replacement/upgrade are lower than previously reported, possibly owing to improved patients care. Hospitalization in the month prior to the procedure, upgrade, and clinical profile (anticoagulation, ischaemic cardiomyopathy) hint to increased risk, suggesting an individualized planning of the procedure to minimize overall AEs. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Identifier: NCT02076789.
Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Sistema de Registros , Anciano , Muerte Súbita Cardíaca/epidemiología , Remoción de Dispositivos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del TratamientoRESUMEN
Single-molecule detection by surface-enhanced Raman scattering (SERS) is a powerful spectroscopic technique that is of interest for the sensor development field. An important aspect of optimizing the materials used in SERS-based sensors is the ability to have a high density of "hot spots" that enhance the SERS sensitivity to the single-molecule level. Photodeposition of gold (Au) nanoparticles through electric-field-directed self-assembly on a periodically proton-exchanged lithium niobate (PPELN) substrate provides conditions to form well-ordered microscale features consisting of closely packed Au nanoparticles. The resulting Au nanoparticle microstructure arrays (microarrays) are plasmon-active and support nonresonant single-molecule SERS at ultralow concentrations (<10-9-10-13 M) with excitation power densities <1 × 10-3 W cm-2 using wide-field imaging. The microarrays offer excellent SERS reproducibility, with an intensity variation of <7.5% across the substrate. As most biomarkers and molecules do not support resonance enhancement, this work demonstrates that PPELN is a suitable template for high-sensitivity, nonresonant sensing applications.