Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
3.
J Cardiovasc Pharmacol Ther ; 24(1): 3-10, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29940780

RESUMEN

Dofetilide is a class III antiarrhythmic agent approved by the Food and Drug Administration for the conversion of atrial fibrillation and atrial flutter and maintenance of sinus rhythm in symptomatic patients with persistent arrhythmia. Drug trials showed neutral mortality in post-myocardial infarction patients and those with heart failure. This is a review of postmarket data, including real-world efficacy and safety in a variety of populations. Dofetilide has been used off-label with success in patients with paroxysmal atrial fibrillation and atrial flutter, as well as atrial tachycardia and ventricular tachycardia. The real-world acute conversion rate of atrial fibrillation and atrial flutter is higher than that reported in clinical trials. Dofetilide has an acceptable safety profile when initiated (or reloaded) under hospital monitoring and dosed according to creatinine clearance. Dofetilide is well tolerated and a good choice for patients with acceptable renal function and a normal QT interval, especially if atrioventricular nodal blockade needs to be avoided.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Aleteo Atrial/tratamiento farmacológico , Sistema de Conducción Cardíaco/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , Fenetilaminas/uso terapéutico , Bloqueadores de los Canales de Potasio/uso terapéutico , Sulfonamidas/uso terapéutico , Antiarrítmicos/efectos adversos , Antiarrítmicos/farmacocinética , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/mortalidad , Aleteo Atrial/fisiopatología , Toma de Decisiones Clínicas , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Selección de Paciente , Fenetilaminas/efectos adversos , Fenetilaminas/farmacocinética , Bloqueadores de los Canales de Potasio/efectos adversos , Bloqueadores de los Canales de Potasio/farmacocinética , Factores de Riesgo , Sulfonamidas/efectos adversos , Sulfonamidas/farmacocinética , Resultado del Tratamiento
5.
Europace ; 20(1): 104-115, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28575378

RESUMEN

Aims: To compare the long-term outcomes of standard ablation of stable ventricular tachycardia (VT) vs. substrate modification, and of complete vs. incomplete substrate modification in patients with structural heart disease (SHD) presenting with VT. Methods and results: An electronic search was performed using major databases. The main outcomes were a composite of long-term ventricular arrhythmia (VA) recurrence and all-cause mortality of standard ablation of stable VT vs. substrate modification, and long-term VA recurrence in complete vs. incomplete substrate modification. Six studies were included for the comparison of standard ablation of stable VT vs. substrate modification, with a total of 396 patients (mean age 63 ± 10 years, 87% males), and seven studies were included to assess the impact of extensive substrate modification, with a total of 391 patients (mean age 64 ± years, 90% males). More than 70% of all the patients included had ischaemic cardiomyopathy. Substrate modification was associated with decreased composite VA recurrence/all-cause mortality compared to standard ablation of stable VTs [risk ratio (RR) 0.57, 95% confidence interval (CI) 0.40-0.81]. Complete substrate modification was associated with decreased VA recurrence as compared to incomplete substrate modification (RR 0.39, 95% CI 0.27-0.58). Conclusion: In patients with SHD who had VT related mainly to ischaemic substrates, there was a significantly lower risk of the composite primary outcome of long-term VA recurrence and all-cause mortality among those undergoing substrate modification compared to standard ablation. Long-term success is improved when performing complete substrate modification.


Asunto(s)
Técnicas de Ablación , Taquicardia Ventricular/cirugía , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Adulto , Anciano , Causas de Muerte , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Recurrencia , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
6.
J Innov Card Rhythm Manag ; 9(8): 3274-3281, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32477818

RESUMEN

Atrial fibrillation (AF) is the most common sustained arrhythmia encountered in clinical practice today. For those who present with it, one of the most major risks associated with the condition is stroke. AF is associated with a fivefold increased risk of stroke and thromboembolism. Oral anticoagulation has been the cornerstone of stroke prevention in patients with AF. In some individuals who exhibit a higher risk of bleeding, other alternatives for stroke prevention have been sought, including the use of left atrial appendage occlusion devices and surgical exclusion of the left atrial appendage. Catheter ablation is an important treatment strategy in those patients for whom a rhythm control strategy has been selected. This article reviews some of the available anticoagulant drug options and their use prior to, during, and after catheter ablation.

7.
J Interv Card Electrophysiol ; 43(2): 193-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25921347

RESUMEN

PURPOSE: Little is known about the usefulness and safety of vascular closure devices (VCDs) in electrophysiological procedures. We present a retrospective analysis of our experience assessing the utility and outcomes of collagen vascular closure device (Angioseal) in patients that required periprocedural anticoagulation and multiple vascular access sites. METHODS: An retrospective chart review of patients who have undergone the deployment of VCD following electrophysiological procedures. RESULTS: In 26 patients (16 males, age 57 ± 15 years, weight 96 ± 21 kg), a total of 76 VCD were deployed. Seventy-three VCDs in femoral veins (right or left) and three in femoral artery. The mean number of VCD per patient was 3 (range, 2-4). VCD was successfully deployed in 75 out of 76 access sites. One patient was noted to have ecchymosis in both groins during follow-up visit. No other complications were noted. CONCLUSIONS: We provide evidence that a collagen plug-based VCD designed for arterial closure can be safely and effectively used to close multiple venous accesses even in the same vein. This can be accomplished with a venotomy size up to 2 Fr larger than the size of the closure device.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Dispositivos de Cierre Vascular , Anticoagulantes/administración & dosificación , Colágeno , Femenino , Técnicas Hemostáticas , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
8.
Int J Hypertens ; 2013: 382802, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23476746

RESUMEN

The incidence of hypertension is increasing every year. Blood pressure (BP) control is an important therapeutic goal for the slowing of progression as well as for the prevention of Cardiovascular disease. The management of hypertension in the high cardiovascular risk population remains a real challenge as the population continues to age, the incidence of diabetes increases, and more and more people survive acute myocardial infarction. We will review hypertension management in the high cardiovascular risk population: patients with coronary heart disease (CHD) and heart failure (HF) as well as in diabetic patients.

9.
J Interv Card Electrophysiol ; 32(2): 121-3, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21327490

RESUMEN

An 84 year-old man with history of recurrent dizziness presented with first degree atrio-ventricular block (1° AVB) and periods of 2:1 AVB. An electrophysiological study revealed a predominant 1:1 AV conduction with markedly prolonged AH interval and frequent His bundle extrasystoles (H). A properly timed H could induce periods of 2:1 AV nodal block and 1:1 AV conduction could only resume following another properly timed H. Procainamide suppressed H. However, because of persistence of the patient symptoms, a permanent pacemaker was eventually inserted. The case illustrates a hitherto not described manifestation of H.


Asunto(s)
Bloqueo Atrioventricular/diagnóstico , Bloqueo de Rama/diagnóstico , Complejos Cardíacos Prematuros/diagnóstico , Electrocardiografía , Marcapaso Artificial , Anciano de 80 o más Años , Bloqueo Atrioventricular/complicaciones , Bloqueo Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/complicaciones , Bloqueo de Rama/terapia , Complejos Cardíacos Prematuros/complicaciones , Complejos Cardíacos Prematuros/terapia , Estudios de Seguimiento , Humanos , Masculino , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...