Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Biomater Sci Eng ; 10(9): 5617-5623, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39133208

RESUMEN

In osteoarthritis (OA), degradation of cartilage pericellular matrix (PCM), the proteoglycan-rich immediate cell microniche, is a leading event of disease initiation. This study demonstrated that biomimetic proteoglycans (BPGs) can diffuse into human cartilage from both normal and osteoarthritic donors and are preferentially localized within the PCM. Applying immunofluorescence (IF)-guided AFM nanomechanical mapping, we show that this localization of BPGs increases the PCM micromodulus of both normal and OA specimens. These results illustrate the capability of BPGs to integrate with degenerative tissues and support the translational potential of BPGs for treating human OA and other diseases associated with proteoglycan degradation.


Asunto(s)
Matriz Extracelular , Osteoartritis , Proteoglicanos , Humanos , Proteoglicanos/metabolismo , Osteoartritis/metabolismo , Osteoartritis/patología , Matriz Extracelular/metabolismo , Materiales Biomiméticos/química , Cartílago Articular/metabolismo , Cartílago Articular/patología , Microscopía de Fuerza Atómica , Cartílago/metabolismo , Cartílago/patología , Anciano
2.
J Biomed Mater Res B Appl Biomater ; 112(1): e35336, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37818847

RESUMEN

The utility of bioprosthetic heart valves (BHVs) is limited to certain patient populations because of their poor durability compared to mechanical prosthetic valves. Histological analysis of failed porcine BHVs suggests that degeneration of the tissue extracellular matrix (ECM), specifically the loss of proteoglycans and their glycosaminoglycans (GAGs), may lead to impaired mechanical performance, resulting in nucleation and propagation of tears and ultimately failure of the prosthetic. Several strategies have been proposed to address this deterioration, including novel chemical fixatives to stabilize ECM constituents and incorporation of small molecule inhibitors of catabolic enzymes implicated in the degeneration of the BHV ECM. Here, biomimetic proteoglycans (BPGs) were introduced into porcine aortic valves ex vivo and were shown to distribute throughout the valve leaflets. Incorporation of BPGs into the heart valve leaflet increased tissue overall GAG content. The presence of BPGs also significantly increased the micromodulus of the spongiosa layer within the BHV without compromising the chemical fixation process used to sterilize and strengthen the tissue prior to implantation. These findings suggest that a targeted approach for molecularly engineering valve leaflet ECM through the use of BPGs may be a viable way to improve the mechanical behavior and potential durability of BHVs.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Animales , Humanos , Porcinos , Proteoglicanos/metabolismo , Biomimética , Válvulas Cardíacas , Válvula Aórtica/metabolismo , Glicosaminoglicanos/química
3.
Prog Biophys Mol Biol ; 176: 67-81, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36055517

RESUMEN

Mechanosensing at the interface of a cell and its surrounding microenvironment is an essential driving force of physiological processes. Understanding molecular activities at the cell-matrix interface has the potential to provide novel targets for improving tissue regeneration and early disease intervention. In the past few decades, the advancement of atomic force microscopy (AFM) has offered a unique platform for probing mechanobiology at this crucial microdomain. In this review, we describe key advances under this topic through the use of an integrated system of AFM (as a biomechanical testing tool) with complementary immunofluorescence (IF) imaging (as an in situ navigation system). We first describe the body of work investigating the micromechanics of the pericellular matrix (PCM), the immediate cell micro-niche, in healthy, diseased, and genetically modified tissues, with a focus on articular cartilage. We then summarize the key findings in understanding cellular biomechanics and mechanotransduction, in which, molecular mechanisms governing transmembrane ion channel-mediated mechanosensing, cytoskeleton remodeling, and nucleus remodeling have been studied in various cell and tissue types. Lastly, we provide an overview of major technical advances that have enabled more in-depth studies of mechanobiology, including the integration of AFM with a side-view microscope, multiple optomicroscopy, a fluorescence recovery after photobleaching (FRAP) module, and a tensile stretching device. The innovations described here have contributed greatly to advancing the fundamental knowledge of extracellular matrix biomechanics and cell mechanobiology for improved understanding, detection, and intervention of various diseases.


Asunto(s)
Cartílago Articular , Mecanotransducción Celular , Microscopía de Fuerza Atómica/métodos , Biofisica , Microscopía Fluorescente
4.
ACS Nano ; 16(1): 1220-1230, 2022 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-35015500

RESUMEN

Molecular engineering of biological tissues using synthetic mimics of native matrix molecules can modulate the mechanical properties of the cellular microenvironment through physical interactions with existing matrix molecules, and in turn, mediate the corresponding cell mechanobiology. In articular cartilage, the pericellular matrix (PCM) is the immediate microniche that regulates cell fate, signaling, and metabolism. The negatively charged osmo-environment, as endowed by PCM proteoglycans, is a key biophysical cue for cell mechanosensing. This study demonstrated that biomimetic proteoglycans (BPGs), which mimic the ultrastructure and polyanionic nature of native proteoglycans, can be used to molecularly engineer PCM micromechanics and cell mechanotransduction in cartilage. Upon infiltration into bovine cartilage explant, we showed that localization of BPGs in the PCM leads to increased PCM micromodulus and enhanced chondrocyte intracellular calcium signaling. Applying molecular force spectroscopy, we revealed that BPGs integrate with native PCM through augmenting the molecular adhesion of aggrecan, the major PCM proteoglycan, at the nanoscale. These interactions are enabled by the biomimetic "bottle-brush" ultrastructure of BPGs and facilitate the integration of BPGs within the PCM. Thus, this class of biomimetic molecules can be used for modulating molecular interactions of pericellular proteoglycans and harnessing cell mechanosensing. Because the PCM is a prevalent feature of various cell types, BPGs hold promising potential for improving regeneration and disease modification for not only cartilage-related healthcare but many other tissues and diseases.


Asunto(s)
Cartílago Articular , Proteoglicanos , Bovinos , Animales , Biomimética , Matriz Extracelular/metabolismo , Mecanotransducción Celular , Condrocitos/metabolismo , Biofisica
5.
Matrix Biol ; 85-86: 47-67, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31655293

RESUMEN

Despite the fact that type III collagen is the second most abundant collagen type in the body, its contribution to the physiologic maintenance and repair of skeletal tissues remains poorly understood. This study queried the role of type III collagen in the structure and biomechanical functions of two structurally distinctive tissues in the knee joint, type II collagen-rich articular cartilage and type I collagen-dominated meniscus. Integrating outcomes from atomic force microscopy-based nanomechanical tests, collagen fibril nanostructural analysis, collagen cross-link analysis and histology, we elucidated the impact of type III collagen haplodeficiency on the morphology, nanostructure and biomechanical properties of articular cartilage and meniscus in Col3a1+/- mice. Reduction of type III collagen leads to increased heterogeneity and mean thickness of collagen fibril diameter, as well as reduced modulus in both tissues, and these effects became more pronounced with skeletal maturation. These data suggest a crucial role of type III collagen in mediating fibril assembly and biomechanical functions of both articular cartilage and meniscus during post-natal growth. In articular cartilage, type III collagen has a marked contribution to the micromechanics of the pericellular matrix, indicating a potential role in mediating the early stage of type II collagen fibrillogenesis and chondrocyte mechanotransduction. In both tissues, reduction of type III collagen leads to decrease in tissue modulus despite the increase in collagen cross-linking. This suggests that the disruption of matrix structure due to type III collagen deficiency outweighs the stiffening of collagen fibrils by increased cross-linking, leading to a net negative impact on tissue modulus. Collectively, this study is the first to highlight the crucial structural role of type III collagen in both articular cartilage and meniscus extracellular matrices. We expect these results to expand our understanding of type III collagen across various tissue types, and to uncover critical molecular components of the microniche for regenerative strategies targeting articular cartilage and meniscus repair.


Asunto(s)
Cartílago Articular/fisiología , Colágeno Tipo III/genética , Colágeno Tipo II/química , Colágeno Tipo I/química , Menisco/fisiología , Animales , Fenómenos Biomecánicos , Cartílago Articular/química , Colágeno Tipo III/metabolismo , Matriz Extracelular/metabolismo , Haploinsuficiencia , Humanos , Masculino , Mecanotransducción Celular , Menisco/química , Ratones , Microscopía de Fuerza Atómica
6.
Interface Focus ; 9(4): 20190013, 2019 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-31263533

RESUMEN

Urinary incontinence is a significant challenge for women who are affected by it. We propose augmenting the tissue structure to restore normal biomechanics by molecularly engineering the tissue using a novel family of biomimetic proteoglycans (BPGs). This work examines the ability of BPGs to modulate the mechanical and physical properties of porcine urethras ex vivo to determine the feasibility of BPGs to be implemented as molecular treatment for stress urinary incontinence (SUI). We investigated compliance by performing a unique radial expansion testing method using urethras from six- to nine-month-old pigs. The urethras were injected with 0.5 ml BPG solution at three sites every approximately 120° (conc.: 25 mg ml-1, 50 mg ml-1 and 75 mg ml-1 in 1× phosphate-buffered saline (PBS); n = 4 per group) and compared them with PBS-injected controls. Young's modulus was calculated by treating the urethra as a thin-walled pressure vessel. A water uptake study was performed by soaking 10 mm urethra biopsy samples that were injected with 0.1 ml BPG solution (conc.: 50 mg ml-1, 100 mg ml-1 and 200 mg ml-1 in 1× PBS; n = 6 per group) in 5 ml PBS for 24 h. Although there was no significant difference in Young's modulus data, there were differences between groups as can be seen in the raw radial expansion testing data. Results showed that BPGs have the potential to increase hydration in samples, and that there was a significant difference in water uptake between BPG-injected samples and the controls (100 mg ml-1 samples versus PBS samples, p < 0.05). This work shows that BPGs have the potential to be implemented as a molecular treatment for SUI, by restoring the diminished proteoglycan content and subsequently increasing hydration and improving the compliance of urethral tissue.

7.
J Biomed Mater Res A ; 107(9): 1977-1987, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31056821

RESUMEN

Biomimetic proteoglycan (BPG) diffusion into articular cartilage has the potential to restore the lost proteoglycan content in osteoarthritic cartilage given these molecules mimic the structure and properties of natural proteoglycans. We examined the diffusion characteristics of BPGs through cartilage with the use of a custom-made in vitro cartilage diffusion model in both normal bovine and human osteoarthritic cartilage explants. BPGs were introduced into the cartilage through essentially one-dimensional diffusion using osteochondral plugs. The molecular diffusion was shown to be size and concentration dependent. Diffusion profiles were found over different diffusion time intervals and the profiles were fit to a nonlinear Fickian diffusion model. Steady state 011012-7diffusion coefficients for BPGs were found to be 4.01 and 3.53 µm2 /s for 180 and 1600 kDa BPGs, respectfully, and these values are similar to other large molecule diffusion in cartilage. In both bovine and osteoarthritic human cartilage, BPGs were found localized around the chondrocytes. BPG localization was examined by labeling collagen type VI and soaking 5 µm thick sections of cartilage with BPG solutions demonstrating that the BPGs diffused into the cartilage and preferentially localized alongside collagen type VI in the pericellular matrix.


Asunto(s)
Materiales Biomiméticos , Cartílago Articular/química , Matriz Extracelular/química , Proteoglicanos , Animales , Materiales Biomiméticos/química , Materiales Biomiméticos/farmacocinética , Materiales Biomiméticos/farmacología , Bovinos , Humanos , Proteoglicanos/química , Proteoglicanos/farmacocinética , Proteoglicanos/farmacología
8.
J Biomed Mater Res B Appl Biomater ; 107(7): 2409-2418, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30784181

RESUMEN

Stress urinary incontinence (SUI), a serious condition which affects ~56% of postmenopausal women, is the involuntary leakage of urine through urethra during physical activity that causes an increase in abdominal pressure. SUI is associated with a decrease in compliance and volume of urethral tissue, likely due to a reduced proteoglycan: collagen ratio in the extracellular matrix and collagen disorganization. Here, we investigated the use of biomimetic proteoglycans (BPGs) to molecularly engineer urethral tissue of New Zealand White rabbits to examine biocompatibility in vivo. BPG concentrations of 50 mg/mL (n = 6, 1 week) and 200 mg/mL (n = 6, 1 week and n = 6, 6 weeks) dissolved in 1× phosphate-buffered saline (PBS) were injected transurethrally using a 9 French cystoscope, and were compared to PBS-injected controls (n = 3, 1 week) and non-injected controls (n = 2, 1 week). Urethral compression pressure measurements confirm BPG injections did not modify normal urethral pressure, as intended. Histological assessment demonstrated biological tolerance of BPGs in urethra and no inflammatory response was detected after 1 and 6 weeks compared to non-injected controls. Confocal imaging of fluorescently-labeled BPG injected urethral specimens demonstrated the integration of BPGs into the interstitial connective tissue and confirmed they were still present after 6 weeks. A general decrease of collagen density was exhibited near injection sites which may be due to increased hydration induced by BPGs. Injection of BPGs is a novel approach that demonstrates potential as molecular treatment for SUI and may be able to reverse some of the degenerative tissue changes of individuals affected by this condition. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: 00B: 000-000, 2019. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2409-2418, 2019.


Asunto(s)
Materiales Biomiméticos/química , Matriz Extracelular/química , Proteoglicanos/química , Ingeniería de Tejidos , Uretra , Incontinencia Urinaria de Esfuerzo , Animales , Conejos , Uretra/metabolismo , Uretra/patología , Incontinencia Urinaria de Esfuerzo/metabolismo , Incontinencia Urinaria de Esfuerzo/patología , Incontinencia Urinaria de Esfuerzo/terapia
9.
J Orthop Res ; 37(2): 403-411, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30480335

RESUMEN

Biomimetic proteoglycans (BPGs) have the potential to treat osteoarthritis (OA) given that these molecules mimic the structure and properties of natural proteoglycans, which are significantly reduced in OA. We examined the effects of BPGs injected into the intra-articular space in an in vivo OA rabbit knee model and evaluated the effect on histological response, joint friction, and BPG distribution and retention. Rabbits underwent ACL transection to create an arthritic state after 5 weeks. OA rabbits were treated with BPGs or Euflexxa® (hyaluronic acid) intra-articular injections. Non-OA rabbits were injected similarly with BPGs; contralateral joints served as controls. The progression of OA and response to injections were evaluated using Mankin and gross grading systems indicating that mild OA was achieved in operated joints. The coefficient of friction (COF) of the intact knee joints were measured using a custom pendulum friction apparatus, showing that OA joints and OA + Euflexxa® joints demonstrated increased COF than non-operated controls, while BPG-injected non-OA and OA + BPGs were not significantly different from non-OA controls. Injected fluorescently labeled BPGs demonstrated that BPGs diffused into cartilage with localization in the pericellular region. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:403-411, 2019.


Asunto(s)
Osteoartritis de la Rodilla/tratamiento farmacológico , Proteoglicanos/uso terapéutico , Animales , Materiales Biomiméticos , Cartílago Articular/patología , Evaluación Preclínica de Medicamentos , Femenino , Colorantes Fluorescentes , Fricción/efectos de los fármacos , Osteoartritis de la Rodilla/patología , Proteoglicanos/farmacología , Conejos
10.
Biomacromolecules ; 18(6): 1713-1723, 2017 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-28398752

RESUMEN

Aging and degeneration of human tissue come with the loss of tissue water retention and associated changes in physical properties partially due to degradation and subsequent loss of proteoglycans. We demonstrated a novel method of fabrication of biomimetic proteoglycans, which mimic the three-dimensional bottlebrush architecture and physical behavior of natural proteoglycans responsible for tissue hydration and structural integrity. Biomimetic proteoglycans are synthesized by an end-on attachment of natural chondroitin sulfate bristles to a synthetic poly(acryloyl chloride) backbone. Atomic force microscopy imaging suggested three-dimensional core-bristle architecture, and hydrodynamic size of biomimetic proteoglycans was estimated at 61.3 ± 12.3 nm using dynamic light scattering. Water uptake results indicated that biomimetic proteoglycans had a ∼50% increased water uptake compared to native aggrecan and chondroitin sulfate alone. The biomimetic proteoglycans are cytocompatible in the physiological ranges of concentrations and could be potentially used to repair damaged or diseased tissue with depleted proteoglycan content.


Asunto(s)
Resinas Acrílicas/síntesis química , Materiales Biomiméticos/síntesis química , Sulfatos de Condroitina/química , Agua/química , Resinas Acrílicas/farmacología , Agrecanos/química , Agrecanos/ultraestructura , Animales , Materiales Biomiméticos/farmacología , Cartílago Articular/química , Cartílago Articular/fisiología , Cartílago Articular/ultraestructura , Bovinos , Línea Celular , Supervivencia Celular/efectos de los fármacos , Sulfatos de Condroitina/ultraestructura , Dermatán Sulfato/química , Dermatán Sulfato/ultraestructura , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Humanos , Sulfato de Queratano/química , Sulfato de Queratano/ultraestructura , Ratones , Microscopía de Fuerza Atómica
11.
J Biomech Eng ; 136(3): 031006, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24292391

RESUMEN

The intervertebral disk (IVD) is a highly hydrated tissue, with interstitial fluid making up 80% of the wet weight of the nucleus pulposus (NP), and 70% of the annulus fibrosus (AF). It has often been modeled as a biphasic material, consisting of both a solid and fluid phase. The inherent porosity and osmotic potential of the disk causes an efflux of fluid while under constant load, which leads to a continuous displacement phenomenon known as creep. IVD compressive stiffness increases and NP pressure decreases as a result of creep displacement. Though the effects of creep on disk mechanics have been studied extensively, it has been limited to nonimpact loading conditions. The goal of this study is to better understand the influence of creep and fluid loss on IVD impact mechanics. Twenty-four human lumbar disk samples were divided into six groups according to the length of time they underwent creep (tcreep = 0, 3, 6, 9, 12, 15 h) under a constant compressive load of 400 N. At the end of tcreep, each disk was subjected to a sequence of impact loads of varying durations (timp = 80, 160, 320, 400, 600, 800, 1000 ms). Energy dissipation (ΔE), stiffness in the toe (ktoe) and linear (klin) regions, and neutral zone (NZ) were measured. Analyzing correlations with tcreep, there was a positive correlation with ΔE and NZ, along with a negative correlation with ktoe. There was no strong correlation between tcreep and klin. The data suggest that the IVD mechanical response to impact loading conditions is altered by fluid content and may result in a disk that exhibits less clinical stability and transfers more load to the AF. This could have implications for risk of diskogenic pain as a function of time of day or tissue hydration.


Asunto(s)
Aceleración , Agua Corporal/fisiología , Disco Intervertebral/fisiología , Vértebras Lumbares/fisiología , Modelos Biológicos , Estimulación Física/métodos , Soporte de Peso/fisiología , Adulto , Cadáver , Fuerza Compresiva/fisiología , Simulación por Computador , Módulo de Elasticidad/fisiología , Transferencia de Energía/fisiología , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Dinámicas no Lineales , Presión , Viscosidad
12.
Tissue Eng Part A ; 20(1-2): 189-96, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23927766

RESUMEN

An estimated 12% of women in the United States suffer from some form of infertility. In vitro fertilization (IVF) is the most common treatment for infertility encompassing over 99% of all assisted reproductive technologies. However, IVF has a low success rate. Live birth rates using IVF can range from 40% in women younger than 35 years to 4% in women older than 42 years. Costs for a successful IVF outcome can be upward of $61,000. The low success rate of IVF has been attributed to the inability of the blastocyst to implant to the uterus. Blastocyst implantation is initiated by L-selectin expressing cells, trophoblasts, binding to L-selectin ligands, primarily sialyl Lewis X (sLeX), on the uterine surface endometrium. Legal and ethical considerations have limited the research on human subjects and tissues, whereas animal models are costly or do not properly mimic human implantation biochemistry. In this work, we describe a cellular model system for quantifying L-selectin adhesion mechanics. L-selectin expression was confirmed in Jeg-3, JAR, and BeWo cell lines, with only Jeg-3 cells exhibiting surface expression. Jeg-3 cells were cultured into three-dimensional spheres, termed "trophospheres," as a mimic to human blastocysts. Detachment assays using a custom-built parallel plate flow chamber show that trophospheres detach from sLeX functionalized slides with 2.75 × 10(-3) dyn of force and 7.5 × 10(-5) dyn-cm of torque. This work marks the first time a three-dimensional cell model has been utilized for quantifying L-selectin binding mechanics related to blastocyst implantation.


Asunto(s)
Implantación del Embrión , Fertilización , Selectina L/metabolismo , Esferoides Celulares/citología , Trofoblastos/citología , Adulto , Fenómenos Biomecánicos , Adhesión Celular , Línea Celular , Femenino , Humanos , Oligosacáridos/metabolismo , Antígeno Sialil Lewis X , Esferoides Celulares/metabolismo , Trofoblastos/metabolismo
13.
J Biomech Eng ; 135(9): 91009, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23775506

RESUMEN

Thirty-four percent of U.S. Navy high speed craft (HSC) personnel suffer from lower back injury and low back pain, compared with 15 to 20% of the general population. Many of these injuries are specifically related to the intervertebral disc, including discogenic pain and accelerated disc degeneration. Numerous studies have characterized the mechanical behavior of the disc under normal physiological loads, while several have also analyzed dynamic loading conditions. However, the effect of impact loads on the lumbar disc--and their contribution to the high incidence of low back pain among HSC personnel--is still not well understood. An ex-vivo study on human lumbar anterior column units was performed in order to investigate disc biomechanical response to impact loading conditions. Samples were subjected to a sequence of impact events of varying duration (Δt = 80, 160, 320, 400, 600, 800, and 1000 ms) and the level of displacement (0.2, 0.5, and 0.8 mm), stiffness k, and energy dissipation ΔE were measured. Impacts of Δt = 80 ms saw an 18-21% rise in k and a 3-7% drop in ΔE compared to the 1000 ms baseline, signaling an abrupt change in disc mechanics. The altered disc mechanical response during impact likely causes more load to be transferred directly to the endplates, vertebral bodies, and surrounding soft tissues and can help begin to explain the high incidence of low back pain among HSC operators and other individuals who typically experience similar loading environments. The determination of a "safety range" for impacts could result in a refinement of design criteria for shock mitigating systems on high-speed craft, thus addressing the low back injury problem among HSC personnel.


Asunto(s)
Disco Intervertebral/fisiología , Vértebras Lumbares/fisiología , Fenómenos Mecánicos , Soporte de Peso , Fenómenos Biomecánicos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...