Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Anesth Analg Crit Care ; 4(1): 40, 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38971842

RESUMEN

BACKGROUND: Lung perfusion defects, mainly due to endothelial and coagulation activation, are a key contributor to COVID-19 respiratory failure. COVID-19 patients may also develop acute kidney injury (AKI) because of renal perfusion deficit. We aimed to explore AKI-associated factors and the independent prediction of standardized minute ventilation (MV)-a proxy of alveolar dead space-on AKI onset and persistence in COVID-19 mechanically ventilated patients. METHODS: This is a multicenter observational cohort study. We enrolled 157 COVID-19 patients requiring mechanical ventilation and intensive care unit (ICU) admission. We collected clinical information, ventilation, and laboratory data. AKI was defined by the 2012 KDIGO guidelines and classified as transient or persistent according to serum creatinine criteria persistence within 48 h. Ordered univariate and multivariate logistic regression analyses were employed to identify variables associated with AKI onset and persistence. RESULTS: Among 157 COVID-19 patients on mechanical ventilation, 47% developed AKI: 10% had transient AKI, and 37% had persistent AKI. The degree of hypoxia was not associated with differences in AKI severity. Across increasing severity of AKI groups, despite similar levels of paCO2, we observed an increased MV and standardized MV, a robust proxy of alveolar dead space. After adjusting for other clinical and laboratory covariates, standardized MV remained an independent predictor of AKI development and persistence. D-dimer levels were higher in patients with persistent AKI. CONCLUSIONS: In critically ill COVID-19 patients with respiratory failure, increased wasted ventilation is independently associated with a greater risk of persistent AKI. These hypothesis-generating findings may suggest that perfusion derangements may link the pathophysiology of both wasted ventilation and acute kidney injury in our population.

2.
Clin Nutr ESPEN ; 63: 105-112, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38941185

RESUMEN

OBJECTIVE: The present systematic review and meta-analysis aims to determine the difference in the interdialytic weight gain (IDWG) between low salt intake diet and normal/high salt intake diet or between nutritional counseling aimed at reducing diet salt intake and no nutritional counseling in patients on chronic hemodialysis. METHODS: Medline, PubMed, Web of Science, and the Cochrane Library were searched. Randomized, crossover or parallel studies and observational studies were considered for inclusion and: 1) included adult patients on chronic hemodialysis since at least 6 months; 2) compared normal salt intake diet with low salt intake diet on IDWG; 3) compared nutritional counseling aimed at reducing diet salt intake with no intervention on IDWG; 4) reported on IDWG. RESULTS: Eight articles (783 patients) were fully assessed for eligibility and included in the investigation. Meta-analysis showed frequencies of patients that increased their weight after dialysis more than 2.5 Kg (events) over total enrolled subjects for each group (control and experimental). As no significant heterogeneity was observed (I2 = 8%; p = 0.36), the pooled analysis was performed using a fixed-effect model. Funnel plot was generated and no obvious asymmetry was observed. The Overall Odds Ratio to get an event in the experimental group, in respect to controls, is 0.57 (0.33-0.97) (p = 0.04] with single studies OR ranging between 0.11 and 1.08. CONCLUSION: The present systematic review and meta-analysis suggest that the use of a low salt diet sodium or a nutritional counseling aimed at reducing diet salt intake is associated with a statistically significant reduction of the IDWG in patients on chronic hemodialysis.

3.
J Clin Med ; 13(11)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38892950

RESUMEN

Objectives: To define if the use of proton pump inhibitors (PPI) is associated with PDF prevalence and characteristics and with time of recovery after dialysis in patients on maintenance hemodialysis. Methods: Patients were defined as experiencing PDF if they spontaneously offered this complaint when asked the open-ended question: "Do you feel fatigued after dialysis?". Time of recovery after dialysis (TIRD) was also assessed for each patient. Each patient was invited to rate the intensity, duration and frequency of PDF from 1 to 5. We defined if patients used PPI (no PPI use or PPI use), the type of used PPI, the dose of used PPI, and the duration of the use of PPI (<1 year or ≥1 year). Results: A total of 346 patients were studied: 259 used PPI (55 used omeprazole, 63 esomeprazole, 54 pantoprazole, 87 lansoprazole, and 7 rabeprazole) and 87 did not. Two hundred and thirty-two patients declared PDF and 114 did not. The median [min-max] TIRD was 210 min [0-1440]. The prevalence of PDF in PPI users and PPI non-users was 67% and 68%, respectively (p = 0.878). The median [min-max] TIRD did not differ significantly between PPI users and PPI non-users (180 [0-1440] and 240 [0-1440], respectively; p = 0.871). Median PDF intensity, duration, frequency, and severity did not differ significantly between PPI use and no use. The prevalence of PDF was similar among the different types of PPI use and did not differ with respect to PPI non-users. Duration of PPI exposure was <1 year in 40 patients and ≥1 year in 219 patients. The prevalence of PDF did not differ between the two exposures. The correlation matrix between PPI equivalent dose, PPI treatment duration and PDF frequency, PDF characteristics, and TIRD showed whether there was statistical significance. Conclusions: The use of PPI is not associated with PDF and time of recovery after dialysis in patients on maintenance hemodialysis.

4.
J Clin Med ; 13(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38893046

RESUMEN

Objective: The use of selective serotonin reuptake inhibitors (SSRIs) is common among hemodialysis patients who receive treatment for depression. However, studies on the efficacy of SSRIs in patients on chronic hemodialysis are few and have led to conflicting results. The present systematic review aims to evaluate, in randomized, controlled studies (RCSs), the efficacy of SSRI administration in reducing symptoms of depression in patients on chronic hemodialysis when compared with placebo or psychological interventions. Method: Research was run on December 2023 in the following databases: Ovid MEDLINE (1985 to present); Ovid EMBASE (1985 to present); Cochrane Library (Wiley); and PubMed (1985 to present). The primary outcome was the frequency and severity of the symptoms of depression assessed through the Beck Depression Inventory (BDI) or the Hamilton Depression Rating Scale (HAMD). The secondary outcome was the prevalence of adverse events. Results: Seven studies totaling 433 patients were included. The number of patients in each individual study ranged from 13 to 120. The length of studies ranged from 8 weeks to 6 months. Heterogeneous data precluded informative meta-analysis. Three studies compared sertraline with a placebo. Of these, two demonstrated that sertraline was better than the placebo in reducing the symptoms of depression while one showed no statistically significant differences between sertraline and the placebo. One study, comparing fluoxetine with a placebo showed that the symptoms of depression did not differ significantly at 8 weeks. In another study, escitalopram administration led to a significantly greater reduction in the Hamilton Depression Rating Scale score compared to a placebo, as well as in the Hamilton Anxiety Rating Scale score. In one study, citalopram and psychological interventions were both effective in reducing the symptoms of depression and anxiety and, in another study, sertraline was modestly more effective than CBT at 12 weeks in reducing the symptoms of depression. Conclusions: SSRIs may be effective in reducing the symptoms of depression in patients on chronic hemodialysis. SSRI administration, at the dosage used in the studies included in the present systematic review, seems safe in most hemodialysis patients. However, the paucity of studies and the limited number of patients included in the trials may suggest that further randomized, controlled studies are needed to determine if SSRIs may be used routinely in daily clinical practice in such a population.

5.
BMC Pregnancy Childbirth ; 24(1): 402, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822258

RESUMEN

BACKGROUND: The COVID-19 pandemic has challenged the provision of maternal care. The IMAgiNE EURO study investigates the Quality of Maternal and Newborn Care during the pandemic in over 20 countries, including Switzerland. AIM: This study aims to understand women's experiences of disrespect and abuse in Swiss health facilities during the COVID-19 pandemic. METHODS: Data were collected via an anonymous online survey on REDCap®. Women who gave birth between March 2020 and March 2022 and answered an open-ended question in the IMAgiNE EURO questionnaire were included in the study. A qualitative thematic analysis of the women's comments was conducted using the International Confederation of Midwives' RESPECT toolkit as a framework for analysis. FINDINGS: The data source for this study consisted of 199 comments provided by women in response to the open-ended question in the IMAgiNE EURO questionnaire. Analysis of these comments revealed clear patterns of disrespect and abuse in health facilities during the COVID-19 pandemic. These patterns include non-consensual care, with disregard for women's choices and birth preferences; undignified care, characterised by disrespectful attitudes and a lack of empathy from healthcare professionals; and feelings of abandonment and neglect, including denial of companionship during childbirth and separation from newborns. Insufficient organisational and human resources in health facilities were identified as contributing factors to disrespectful care. Empathic relationships with healthcare professionals were reported to be the cornerstone of positive experiences. DISCUSSION: Swiss healthcare facilities showed shortcomings related to disrespect and abuse in maternal care. The pandemic context may have brought new challenges that compromised certain aspects of respectful care. The COVID-19 crisis also acted as a magnifying glass, potentially revealing and exacerbating pre-existing gaps and structural weaknesses within the healthcare system, including understaffing. CONCLUSIONS: These findings should guide advocacy efforts, urging policy makers and health facilities to allocate adequate resources to ensure respectful and high-quality maternal care during pandemics and beyond.


Asunto(s)
COVID-19 , Servicios de Salud Materna , Investigación Cualitativa , Humanos , COVID-19/psicología , COVID-19/epidemiología , Femenino , Suiza , Adulto , Embarazo , Encuestas y Cuestionarios , Servicios de Salud Materna/normas , Actitud del Personal de Salud , SARS-CoV-2 , Relaciones Profesional-Paciente , Respeto , Calidad de la Atención de Salud
6.
BMJ Paediatr Open ; 8(Suppl 2)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589039

RESUMEN

BACKGROUND: This study aimed at documenting the levels of stress, depression, anxiety and participation in care among mothers versus fathers of newborns hospitalised in a third-level neonatal intensive care unit (NICU) in Northern Italy. METHODS: Parental stress, depression and anxiety were assessed by the Parental Stressor Scale in NICU (PSS:NICU), the Edinburgh Postnatal Depression Scale (EPDS) and the State-Trait Anxiety Inventory (STAI). Participation in care was evaluated with the Index of Parental Participation. Differences between mothers and fathers were assessed with the Mood's median test and z-test, respectively for continuous and discrete variables. Multivariate analyses controlling for potential confounders were performed to confirm gender differences. RESULTS: 191 parents (112 mothers and 79 fathers) were enrolled. Mothers reported significantly higher median scores for stress (2.9 vs 2.2, p<0.001) and trait anxiety (37 vs 32, p=0.004) and higher depression rates (EPDS ≥12: 43.8% vs 19.0%, p<0.001). 'High stress' (PSS:NICU ≥3) was reported by 45.5% of mothers compared with 24.1% of fathers (p=0.004). The frequency of the three conditions simultaneously was significantly higher among mothers (20.0% vs 3.8%, p=0.016), with the vast majority of mothers (76.0%) suffering from at least one condition compared with less than half of fathers (45.3%, p<0.001). Participation in care was more frequent in mothers (median score: 19 vs 15, p<0.001), with the exception of activities related to advocacy (median 5 vs 4, p=0.053). In a multivariate analysis, gender differences in mental health outcomes did not change. CONCLUSIONS: Routine screening of mental distress among parents of infants in NICU is warranted, and gender differences need to be acknowledged in order to deliver tailored support and to promote collaboration with the family of vulnerable newborns. Knowledge and skills on how to prevent and cope with mental distress of parents should be part of the core curriculum of staff working in NICU.


Asunto(s)
Depresión , Unidades de Cuidado Intensivo Neonatal , Femenino , Lactante , Humanos , Recién Nacido , Estudios Transversales , Depresión/epidemiología , Depresión/diagnóstico , Estrés Psicológico/epidemiología , Estrés Psicológico/psicología , Padres/psicología , Ansiedad/epidemiología , Ansiedad/diagnóstico , Ansiedad/psicología
7.
J Ultrasound ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38598134

RESUMEN

BACKGROUND: Solitary fibrous tumors of the liver (SFTL) are rare neoplasms, whose identification and definition of malignant potential are challenging. CASE PRESENTATION: A 62-year-old patient underwent conventional imaging and CEUS to characterize an indeterminate liver lesion after other imaging techniques were inconclusive. In fact, all diagnostic techniques concluded that it was a partially fibrotic lesion, while CEUS determined its extra-hepatocellular origin and malignant potential, initially hypothesized to be a cholangiocarcinoma. Due to the possible risk of seeding following a biopsy procedure, the patient was a candidate for surgery. Subsequently, histopathological examination revealed SFTL. CONCLUSION: CEUS confidently characterized the malignancy and hypothesized the origin of the liver lesion, thus aiding in treatment planning.

8.
Int Urol Nephrol ; 56(7): 2313-2323, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38446246

RESUMEN

PURPOSE: The present systematic review and meta-analysis aimed at evaluating the effect of low dialysate sodium concentration on interdialytic weight gain (IDWG) in chronic hemodialysis patients. METHODS: Studies were eligible for inclusion if they were English language papers published in a peer-reviewed journal and met the following inclusion criteria: (1) studies in adult patients (over 18 years of age), (2) included patients on chronic hemodialysis since at least 6 months; (3) compared standard (138-140 mmol/l) or high (> 140 mmol/l) dialysate sodium concentration with low (< 138 mmol/l) dialysate sodium concentration; (4) Included one outcome of interest: interdialytic weight gain. Medline, PubMed, Web of Science, and the Cochrane Library were searched for the quality of reporting for each study was performed using the Quality Assessment Tool of Controlled Intervention Studies of the National Institutes of Health. The quality of reporting of each cross-over study was performed using the Revised Cochrane Risk of Bias (RoB) tool for cross-over trials as proposed by Ding et al. RESULTS: Nineteen studies (710 patients) were included in the analysis: 15 were cross-over and 4 parallel randomized controlled studies. In cross-over studies, pooled analysis revealed that dialysate sodium concentration reduced IDWG with a pooled MD of - 0.40 kg (95% CI - 0.50 to - 0.30; p < 0.001). The systematic review of four parallel, randomized, studies revealed that the use of a low dialysate sodium concentration was associated with a significant reduction of the IDWG in two studies, sustained and almost significant (p = 0.05) reduction in one study, and not significant reduction in one study. CONCLUSION: Low dialysate sodium concentration reduces the IDWG in prevalent patients on chronic hemodialysis.


Asunto(s)
Soluciones para Diálisis , Diálisis Renal , Sodio , Aumento de Peso , Humanos , Sodio/análisis , Fallo Renal Crónico/terapia , Soluciones para Hemodiálisis/química
9.
Braz J Psychiatry ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38368551

RESUMEN

OBJECTIVES: To report suicide planning and attempts' in a lifetime among Brazilian physicians and to explore associated risk factors. METHODS: A nation-wide, online survey based on the Tool for the Assessment of Suicide Risk and Satisfaction with Life Scale was conducted among Brazilian physicians (January 2018 - January 2019). Multivariate explored associations of demographics, psychological, and work-related factors on suicide planning and attempts reports. RESULTS: Among 4,148 respondents, 1,946 (53.5%) were male, 2,527 (60.9%) were 30-60 years old, 2,675 (64.5%) had 2-4 work-contracts and 1,725 (41.6%) reported a weekly workload of 40-60 hours. Overall prevalence of suicide plans was 8.8% (n=364) and suicide attempts were reported by 3.2% (n=133) of respondents. Daily (AdjOR=7.857;95%CI 2.282-27.051, p=0.002) or weekly emotional exhaustion (AdjOR=7.953; 95%CI 2.403-26.324, p=0.001), daily frustration with work (AdjOR=3.093;95%CI 1.711-5.588, p<0.001), and being bisexual (AdjOR=5.083;95%CI 2.544-10.158, p<0.001) were significantly associated with higher odds of reports. Among extremely dissatisfied professionals 38.3% reported having made suicide planning and attempts, while among extremely satisfied only 2.8% reported it (p<0.001). CONCLUSIONS: Brazilian physicians with a lifetime history of suicide planning and attempts presented a higher association with emotional exhaustion and frustration with work. Urgent actions are needed to promote professional protection policies and resilience.

10.
BMC Musculoskelet Disord ; 25(1): 128, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38341539

RESUMEN

BACKGROUND: Unicompartmental knee arthroplasty (UKA) procedures are considered to be more technically demanding than conventional total knee arthroplasty (TKA), requiring a longer learning curve and more expert surgical skills. Despite some clear advantages of UKA over TKA (such as lesser blood loss, greater bone stock, greater knee performances, etc.), UKA evidenced a greater rate of revision. OBJECT: This study investigated the learning curve of Persona Partial Knee (PPK) arthroplasty for primary medial UKA performed by a single, non-designer surgeon. PPK is a fixed-bearing, compartment-specific implant. The primary outcome of interest for this study was to evaluate the learning curve of the surgical duration. The secondary outcome of interest was to evaluate the learning curve of radiological implant positioning. METHODS: Patients who underwent primary medial UKA using PPK (Zimmer-Biomet, Warsaw IN, USA) were prospectively enrolled for the study. All surgeries were performed by a single, non-designer surgeon experienced in knee and hip arthroplasty. The primary outcome of interest was to evaluate the surgical duration. The secondary outcome of interest was to evaluate the implant positioning. The learning curve was estimated using an appropriate nonlinear polynomial regression model with a lower Akaike Information Criterion (AIC). RESULTS: One hundred twenty five patients were enrolled in the study. 59% of them (74 of 125 patients) were women. The patients' mean age at the time of surgery was 70.1 ± 9.5 years and their mean body mass index (BMI) was 27.8 ± 4.2 kg/m2. Curve stabilisation of the surgical time was at the 94th patient, of the tibial angle at the 47th patient, of the tibial slope at the 54th patient, of the anterior protrusion at the 29th patient, and of the posterior protrusion at the 51st patient. CONCLUSIONS: The learning curve for component positioning was achieved in approximately 50 cases. The curve of the surgical time achieved a plateau at 94 Persona Partial Knee. Additionally, the factors directly correlated with earlier stabilization of the learning curve in terms of component positioning were: male gender, younger age, right side, and larger components.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Masculino , Femenino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Curva de Aprendizaje , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Resultado del Tratamiento
11.
Arch Orthop Trauma Surg ; 144(3): 1345-1352, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38108862

RESUMEN

INTRODUCTION: Evidence on patellar height changes following unicompartmental knee arthroplasty (UKA) is lacking. Therefore, this study compared the patella height in patients who underwent medial versus lateral UKA. Moreover, a subgroup analysis was conducted to investigate whether sex, age, and BMI of the patients exert an influence on the postoperative patellar height. METHODS: Radiographs and hospital records of patients undergoing UKA were prospectively collected. Surgeries were performed by one author with long experience in UKA in a highly standardised fashion. The implants were fixed-bearing medial PPK (Zimmer Biomet, Warsaw, Indiana, USA) and fixed-bearing lateral ZUK (Lima Corporate, Udine, Italy). The patellar height was measured using the Insall-Salvati and Caton-Deschamps indices. RESULTS: A total of 203 patients were included: 119 patients were included in the medial and 84 in the lateral UKA. The mean age of the patients was 68.9 ± 6.7 years, and the mean BMI was 28.1 ± 4.1 kg/m2. 54% (110 of 203 patients) were women. On admission, between-group comparability was found in age, BMI, sex, and length of the follow-up. No between-group and within-group difference was detected pre- and post-operatively in the Insall-Salvati and Caton-Deschamps indices in patients who have undergone medial versus lateral UKA. Concerning the subgroup analyses, no between-group and within-group difference was detected pre- and post-operatively in all comparisons according to sex, age, and BMI. CONCLUSION: No difference was found in patella height in patients who have undergone medial compared to lateral UKA. Furthermore, there was no evidence of an association between patient characteristics (sex, age, BMI) and patella height between medial and lateral UKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Rótula/diagnóstico por imagen , Rótula/cirugía , Periodo Posoperatorio , Radiografía
12.
Int Breastfeed J ; 18(1): 30, 2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37296409

RESUMEN

BACKGROUND: Evidence has shown that restrictions during the COVID-19 pandemic have negatively affected breastfeeding support and outcomes in hospitals in many countries. The aims of the study were to describe exclusive breastfeeding rates and identify factors associated with exclusive breastfeeding at hospital discharge among women who gave birth during the COVID-19 pandemic in Israel. METHODS: A cross-sectional online anonymous survey based on WHO standards for improving quality of maternal and newborn care in health facilities was conducted among a sample of women who gave birth to a healthy singleton infant in Israel during the pandemic (between March 2020 and April 2022). The socio-ecological approach was employed to examine intrapersonal, interpersonal, organizational, and community/society factors associated with exclusive breastfeeding at hospital discharge according to women perspectives. RESULTS: Among the 235 Israeli participants, 68.1% exclusively breastfed, 27.7% partially breastfed, and 4.2% did not breastfeed at discharge. Results of the adjusted logistic regression model showed that factors significantly associated with exclusive breastfeeding were the intrapersonal factor of multiparity (adjusted OR 2.09; 95% Confidence Interval 1.01,4.35) and the organizational factors of early breastfeeding in the first hour (aOR 2.17; 95% CI 1.06,4.45), and rooming-in (aOR 2.68; 95% CI 1.41,5.07). CONCLUSIONS: Facilitating early breastfeeding initiation and supporting rooming-in are critical to promoting exclusive breastfeeding. These factors, reflecting hospital policies and practices, along with parity, are significantly associated with breastfeeding outcomes and highlight the influential role of the maternity environment during the COVID-19 pandemic. Maternity care in hospitals should follow evidence-based breastfeeding recommendations also during the pandemic, promoting early exclusive breastfeeding and rooming-in among all women, with particular attention to providing lactation support to primiparous women. TRIAL REGISTRATION: Clinical Trials NCT04847336.


Asunto(s)
COVID-19 , Servicios de Salud Materna , Femenino , Humanos , Recién Nacido , Embarazo , Lactancia Materna , COVID-19/epidemiología , Estudios Transversales , Israel/epidemiología , Pandemias
13.
Arch Orthop Trauma Surg ; 143(10): 6371-6379, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37244888

RESUMEN

PURPOSE: The primary goal of this study is to compare clinical outcomes, complication rate, and survivorship in octogenarians who underwent total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) by performing a matched cohort analysis. METHODS: We analyzed 75 medial UKAs performed by a single experienced surgeon. The included cases were matched with 75 TKAs performed during the same study period. Potential TKA matches used identical exclusion criteria. UKAs were age-, gender-, and body mass index (BMI)-matched at the rate of 1 UKA to 1 TKA from our departmental database. Clinical evaluation included the visual analog scale for pain, range of motion (ROM-flexion and extension), Knee Society Score (KSS), and Oxford Knee Score (OKS). Each patient was clinically evaluated on the day before the surgery (T0) and at two follow-ups at least 12 months (T1) and 24 months (T2) after the surgery. For the survivorship, revision was defined as failure of the implant (periprosthetic joint infection, periprosthetic fracture, or aseptic loosening), and survival was based on implant revision or patient death. Undesirable clinical developments that were not present at baseline or that increased in severity after treatment were classified as adverse events. RESULTS: The mean age at the time of the surgery was 82.1 ± 1.9 years for UKA and 81.5 ± 1.8 years for TKA (p = 0.06). The two groups differed in regard to surgical time (UKA 44.9 ± 7.2 min; TKA 54.4 ± 11.3 min; p < 0.001); furthermore, the UKA group showed better function (ROM; flexion and extension) than the TKA group at each follow-up time point (p < 0.05). Both groups reported a significant improvement in all clinical scores (KSS and OKS) when compared with their preoperative status (p < 0.05), while no differences were found between the groups at each follow-up (p > 0.05). The UKA group reported 7 (9.3%) failures, while TKA reported 6 failures. There were no survival differences between the groups (T1: p = 0.2; T2: p = 0.5). Overall complication rate was 6% in the UKA group versus 9.75% in TKA (p = 0.2). CONCLUSION: The UKA and TKA patients had similar clinical outcomes, post-operative range of motion, and survivorship in octogenarians with medial knee osteoarthritis, with comparable complication rate. Both the surgical procedures may be considered in this patient population, but further long-term follow-up is needed. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Anciano de 80 o más Años , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Supervivencia , Reoperación , Estudios de Cohortes , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Estudios Retrospectivos
14.
J Glob Health ; 13: 06013, 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37144478

RESUMEN

Background: Recent evidence revealed significant gaps in the quality of maternal and newborn care in the World Health Organization (WHO) European Region (EUR) countries. Collecting and analyzing women's views on their needs and priorities is crucial for developing actions to improve the quality of maternal and newborn care. With this study from the IMAgiNE EURO Project, we aimed to add to previous quantitative studies by analysing emerging themes from women's suggestions on how to improve the quality of maternal and newborn care during facility-based birth in Italy during the COVID-19 pandemic. Methods: We collected data from mothers giving birth during the coronavirus 2019 (COVID-19) pandemic using a validated online anonymous WHO standard-based questionnaire consisting of open-ended questions. Using a word co-occurrence network (WCON), we analysed responses in Italian from women who gave birth between March 2020 and March 2022. This approach entails a graphical representation of word pairings that frequently co-occur across sentences and compose clusters. Results: The texts, produced by 2010 women participating in the study, consisted of 79 204 words and 3833 sentences. Eight clusters emerged with WCON, the three largest of which were related to companionship during childbirth, breastfeeding support, and physical resources. The term "swab", associated with other terms in the COVID-19 domain, had the highest degree of centrality, thus representing a core topic. Conclusions: The key emerging themes from women's suggestions can be used to shape policies to improve the quality of care for mothers and newborns. Our WCON analysis offers a valid approach to quickly screen large textual data on quality of care, providing a first set of major themes identified by clusters. As such, it could be used to improve documentation of service users' suggestions promoting the engagement of both researchers and policymakers. Registration: ClinicalTrials.gov: NCT04847336.


Asunto(s)
COVID-19 , Pandemias , Embarazo , Femenino , Recién Nacido , Humanos , COVID-19/epidemiología , Parto Obstétrico , Madres , Lactancia Materna
15.
Eur J Orthop Surg Traumatol ; 33(7): 3081-3088, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37017739

RESUMEN

BACKGROUND: A clinical trial comparing MB (mobile-bearing) versus FB (fixed-bearing) in medial partial knee arthroplasty (PKA) in octagenarians has been conducted. The focus of the present study was on PROMs, range of motion (ROM), implant positioning and implants survivorship. The hypothesis of the present study was that MB implants performed better than FB in PKA in octogenarians. METHODS: The first group received FB PKA-PPK®; the second received MB PKA-Oxford. Patients were not randomly allocated. The following PROMs were administered at T0 (pre-operatively), T1 (1 year after surgery), and T2 (3 years after surgery): visual analogue scale (VAS), Knee Society Score (KSS) and Oxford Knee Score (OKS). Data regarding the implant survivorship and ROM were also collected. Furthermore, the following radiographic parameters were measured: Femoral component varus/valgus; Tibial component varus/valgus; Anteroposterior slope. RESULTS: At T0, 28 patients were included in the FB and 33 in the MB group. The surgical time was shorter in the FB group (p < 0.001). No difference between FB and MB in ROM, VAS, KSS, and OKS at each follow-up (p > 0.05). No difference was found in implant positioning (p > 0.05). At last follow-up, FB group reported three failures caused by aseptic loosening. Four failures were observed in the MB cohort: two for bearing dislocation and two for aseptic loosening. The Kaplan-Meier Curve found no differences in implant survivorship. CONCLUSIONS: According to the main findings of the present clinical trial, MB implants performed similar to FB in PKA in octogenarians. The FB group demonstrated shorted surgical time. No difference was found in patient reported outcome measures, ROM, implant positioning, and survivorship. LEVEL OF EVIDENCE: Level II, prospective study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Anciano de 80 o más Años , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Octogenarios , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Diseño de Prótesis , Rango del Movimiento Articular , Resultado del Tratamiento
16.
Int Breastfeed J ; 18(1): 15, 2023 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-36895002

RESUMEN

BACKGROUND: Little is known about women's experience of care and views on early breastfeeding during the COVID-19 pandemic in Norway. METHODS: Women (n = 2922) who gave birth in a facility in Norway between March 2020 and June 2021 were invited to answer an online questionnaire based on World Health Organization (WHO) Standard-based quality measures, exploring their experiences of care and views on early breastfeeding during the COVID-19 pandemic. To examine associations between year of birth (2020, 2021) and early breastfeeding-related factors, we estimated odds ratios (ORs) with 95% confidence intervals (CIs) using multiple logistic regression. Qualitative data were analysed using Systematic Text Condensation. RESULTS: Compared to the first year of the pandemic (2020), women who gave birth in 2021 reported higher odds of experiencing adequate breastfeeding support (adjOR 1.79; 95% CI 1.35, 2.38), immediate attention from healthcare providers when needed (adjOR 1.89; 95% CI 1.49, 2.39), clear communication from healthcare providers (adjOR 1.76; 95% CI 1.39, 2.22), being allowed companion of choice (adjOR 1.47; 95% CI 1.21, 1.79), adequate visiting hours for partner (adjOR 1.35; 95% CI 1.09, 1.68), adequate number of healthcare providers (adjOR 1.24; 95% CI 1.02, 1.52), and adequate professionalism of the healthcare providers (adjOR 1.65; 95% CI 1.32, 2.08). Compared to 2020, in 2021 we found no difference in skin-to-skin contact, early breastfeeding, exclusive breastfeeding at discharge, adequate number of women per room, or women's satisfaction. In their comments, women described understaffed postnatal wards, early discharge and highlighted the importance of breastfeeding support, and concerns about long-term consequences such as postpartum depression. CONCLUSIONS: In the second year of the pandemic, WHO Standard-based quality measures related to breastfeeding improved for women giving birth in Norway compared to the first year of the pandemic. Women's general satisfaction with care during COVID-19 did however not improve significantly from 2020 to 2021. Compared to pre-pandemic data, our findings suggest an initial decrease in exclusive breastfeeding at discharge during the COVID-19 pandemic in Norway with little difference comparing 2020 versus 2021. Our findings should alert researchers, policy makers and clinicians in postnatal care services to improve future practices.


Asunto(s)
Lactancia Materna , COVID-19 , Embarazo , Femenino , Humanos , Pandemias , COVID-19/epidemiología , Parto , Noruega/epidemiología
17.
Artículo en Alemán | MEDLINE | ID: mdl-36752819

RESUMEN

INTRODUCTION: The COVID-19 pandemic may increase women's vulnerability through violations of their integrity during birth. In a cross-sectional study (March 2020 to March 2022), we investigated how women giving birth experienced maternity care during the pandemic in Germany and which factors were associated with their birth integrity. METHODS: In a survey (validated questionnaire and two open-ended questions), women ≥ 18 years described their experiences of maternity care. We conducted quantitative analyses using descriptive statistics and logistic regressions to investigate factors associated with dignified care and emotional support, which are understood as proxies of birth integrity. We analysed the open-ended questions through inductive content analysis. RESULTS: We included data from 1271 participants and 214 comments. The majority of respondents felt emotionally supported (71%) and treated with dignity (76%). One third reported not always being involved in decision-making, while 14% felt they were subjected to physical, verbal or emotional abuse. For 57% of women, their companion of choice was absent or their presence limited. Those factors were all associated with the chances of feeling treated with dignity and emotionally supported. The qualitative comments provided an insight into what specifically women perceive as violating their integrity. DISCUSSION: During the COVID-19 pandemic, the vulnerability of parturients lies in the violation of their birth integrity. Measures to promote respectful maternity care of women who give birth include comprehensive structural and political solutions as well as further research on the determinants of birth integrity.


Asunto(s)
COVID-19 , Servicios de Salud Materna , Embarazo , Femenino , Humanos , Pandemias , Estudios Transversales , COVID-19/epidemiología , Alemania/epidemiología
18.
J Knee Surg ; 36(3): 246-253, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34520561

RESUMEN

The aim of the study is to evaluate whether the use of the new instrumentation Microplasty (MP) improves component positioning and the reliability of the surgical technique, reducing the implant outliers from the recommended range and providing a more accurate resection, while avoiding insufficient or excessive tibial resection and clinical scores. We prospectively analyzed clinical and radiographic outcomes of three consecutive cohorts for a total of 227 implants at a minimum follow-up of 36 months. The first cohort consisted of 67 Oxford unicompartmental knee arthroplasty (OUKA), using the phase III (Ph-III). The second cohort consisted of 136 OUKA, with the MP instrumentation. The third cohort consisted of 24 hypoallergenic OUKA, using the MP instrumentation (TiNbN). Postoperative alignment of the knee in the coronal and sagittal plane was measured using radiographs. No clinical differences were found among the three groups (p > 0.05). A significant difference was found on the slope between Ph-III and MP (p = 0.0005). Moreover, a significant difference was found in tibial angle and in tibial slope in arthroplasty with femoral size small (S), compared with size medium (M) or large (Ly) (tibia varus/valugs angle: p = 0.0484; tibial slope: p = 0.04). Similar results were found between small (AA, A, B) tibial size and large (C, D, E, F) tibial size for tibial varus/valgus (p = 0.03) angle and tibial slope (p = 0.003). A significant difference was found between Ph-III and MP in tibial slope in patients with body mass index (BMI) ≥25 kg/m2 (p = 0.0003). A positive correlation was noted between the femoral and tibial sizes and the tibial angle and the slope, and a negative correlation between weight and the tibial slope; furthermore, a positive correlation was found between Oxford knee score and radiographic angles. The MP instrumentation seems to be effective in determining the tibial cut and, particularly, improving the tibial slope, compared with Ph-III. The tibial slope is directly affected by the weight and measurements of the components, regardless of the instruments or the number of pegs, while clinical outcomes are correlated with implant position. This prospective comparative study reflects level of evidence II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía
19.
Eur J Orthop Surg Traumatol ; 33(4): 1315-1328, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35643948

RESUMEN

BACKGROUND: The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. METHODS: The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient's Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). RESULTS: The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. CONCLUSIONS: Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. LEVEL OF EVIDENCE: LEVEL II: Comparative study.


Asunto(s)
Hipersensibilidad , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Prótesis de la Rodilla/efectos adversos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Aleaciones , Hipersensibilidad/etiología , Resultado del Tratamiento , Estudios Retrospectivos
20.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 1063-1071, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36374325

RESUMEN

PURPOSE: This retrospective study aims to analyse the survivorship and functional outcomes of two samples with similar preoperative clinical and demographic data of lateral unicompartmental knee arthroplasty (UKA) performed with robotic and conventional surgery at a minimum 5-year follow-up. METHODS: In this retrospective study, the clinical records of two cohorts for 95 lateral UKA implants were analysed. The first cohort consisted of 43 patients with cemented lateral UKA performed with the conventional procedure (Conventional group). The second cohort consisted of 52 patients who received robot-assisted cemented lateral UKA (Robotic group). Clinical evaluation of the two samples entailed evaluating the Knee Injury and Osteoarthritis Outcome Score divided into subscales (symptoms and stiffness, pain, function in daily living, function in sport and recreation and quality of life) for each patient. Revision was defined as the failure of the implant (periprosthetic joint infection, periprosthetic fracture or aseptic loosening), and survival was based on implant revision. RESULTS: The mean follow-up time was 90.3 ± 9.1 months for the Conventional Group and 95.4 ± 11.0 months for the Robotic Group (n.s.). Each patient was clinically evaluated on the day before surgery (T0), at a minimum 1-year follow-up (T1) and at a minimum 5-year follow-up (T2). In both groups, all clinical scores improved between T0 and T1 and between T0 and T2 (p < 0.05); for both groups, no differences were noted in any clinical scores between T1 and T2 (n.s.). No significant differences in any clinical score were found between the two groups at each follow-up (n.s.). Survival analysis reported no differences between the two groups at the final 1-year follow-up, with three failures (2 aseptic loosening and 1 periprosthetic fracture) in the Conventional group and two failures (1 patellofemoral osteoarthritis and 1 inexplicable pain) in the Robotic group (n.s.). CONCLUSIONS: This study shows excellent clinical outcomes and revision rates in robotic arm-assisted and manual techniques for lateral UKA, with no clinical differences at medium- to long-term follow-up. LEVEL OF EVIDENCE: Level III-comparative study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Fracturas Periprotésicas , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Fracturas Periprotésicas/cirugía , Supervivencia , Calidad de Vida , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Dolor/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...