1.
J Biomech ; 157: 111696, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37413822

RESUMEN

Pressure-volume curves of the lung are classical measurements of lung function and are impacted by changes in lung structure due to disease or shifts in air-delivery volume or cycling rate. Diseased and preterm infant lungs have been found to show heterogeneous behavior which is highly frequency dependent. This breathing rate dependency has motivated the exploration of multi-frequency oscillatory ventilators to deliver volume oscillation with optimal frequencies for various portions of the lung to provide more uniform air distribution. The design of these advanced ventilators requires the examination of lung function and mechanics, and an improved understanding of the pressure-volume response of the lung. Therefore, to comprehensively analyze whole lung organ mechanics, we investigate six combinations of varying applied volumes and frequencies using ex-vivo porcine specimens and our custom-designed electromechanical breathing apparatus. Lung responses were evaluated through measurements of inflation and deflation slopes, static compliance, peak pressure and volume, as well as hysteresis, energy loss, and pressure relaxation. Generally, we observed that the lungs were stiffer when subjected to faster breathing rates and lower inflation volumes. The lungs exhibited greater inflation volume dependencies compared to frequency dependencies. This study's reported response of the lung to variations of inflation volume and breathing rate can help the optimization of conventional mechanical ventilators and inform the design of advanced ventilators. Although frequency dependency is found to be minimal in normal porcine lungs, this preliminary study lays a foundation for comparison with pathological lungs, which are known to demonstrate marked rate dependency.


Asunto(s)
Recien Nacido Prematuro , Pulmón , Recién Nacido , Humanos , Porcinos , Animales , Rendimiento Pulmonar/fisiología , Pulmón/fisiología , Fenómenos Fisiológicos Respiratorios , Mecánica Respiratoria/fisiología
2.
Respir Res ; 24(1): 105, 2023 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37031200

RESUMEN

BACKGROUND: Common respiratory illnesses, such as emphysema and chronic obstructive pulmonary disease, are characterized by connective tissue damage and remodeling. Two major fibers govern the mechanics of airway tissue: elastin enables stretch and permits airway recoil, while collagen prevents overextension with stiffer properties. Collagenase and elastase degradation treatments are common avenues for contrasting the role of collagen and elastin in healthy and diseased states; while previous lung studies of collagen and elastin have analyzed parenchymal strips in animal and human specimens, none have focused on the airways to date. METHODS: Specimens were extracted from the proximal and distal airways, namely the trachea, large bronchi, and small bronchi to facilitate evaluations of material heterogeneity, and subjected to biaxial planar loading in the circumferential and axial directions to assess airway anisotropy. Next, samples were subjected to collagenase and elastase enzymatic treatment and tensile tests were repeated. Airway tissue mechanical properties pre- and post-treatment were comprehensively characterized via measures of initial and ultimate moduli, strain transitions, maximum stress, hysteresis, energy loss, and viscoelasticity to gain insights regarding the specialized role of individual connective tissue fibers and network interactions. RESULTS: Enzymatic treatment demonstrated an increase in airway tissue compliance throughout loading and resulted in at least a 50% decrease in maximum stress overall. Strain transition values led to significant anisotropic manifestation post-treatment, where circumferential tissues transitioned at higher strains compared to axial counterparts. Hysteresis values and energy loss decreased after enzymatic treatment, where hysteresis reduced by almost half of the untreated value. Anisotropic ratios exhibited axially led stiffness at low strains which transitioned to circumferentially led stiffness when subjected to higher strains. Viscoelastic stress relaxation was found to be greater in the circumferential direction for bronchial airway regions compared to axial counterparts. CONCLUSION: Targeted fiber treatment resulted in mechanical alterations across the loading range and interactions between elastin and collagen connective tissue networks was observed. Providing novel mechanical characterization of elastase and collagenase treated airways aids our understanding of individual and interconnected fiber roles, ultimately helping to establish a foundation for constructing constitutive models to represent various states and progressions of pulmonary disease.


Asunto(s)
Elastina , Elastasa Pancreática , Porcinos , Humanos , Animales , Elastina/metabolismo , Pulmón/metabolismo , Colágeno/metabolismo , Colagenasas/metabolismo , Colagenasas/farmacología , Fenómenos Biomecánicos
3.
Am J Respir Crit Care Med ; 207(5): 577-586, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36194677

RESUMEN

Rationale: There is continued debate regarding the equivalency of positive-pressure ventilation (PPV) and negative-pressure ventilation (NPV). Resolving this question is important because of the different practical ramifications of the two paradigms. Objectives: We sought to investigate the parallel between PPV and NPV and determine whether or not these two paradigms cause identical ventilation profiles by analyzing the local strain mechanics when the global tidal volume (Vt) and inflation pressure was matched. Methods: A custom-designed electromechanical apparatus was used to impose equal global loads and displacements on the same ex vivo healthy porcine lung using PPV and NPV. High-speed high-resolution cameras recorded local lung surface deformations and strains in real time, and differences between PPV and NPV global energetics, viscoelasticity, as well as local tissue distortion were assessed. Measurements and Main Results: During initial inflation, NPV exhibited significantly more bulk pressure-volume compliance than PPV, suggestive of earlier lung recruitment. NPV settings also showed reduced relaxation, hysteresis, and energy loss compared with PPV. Local strain trends were also decreased in NPV, with reduced tissue distortion trends compared with PPV, as revealed through analysis of tissue anisotropy. Conclusions: Apparently, contradictory previous studies are not mutually exclusive. Equivalent changes in transpulmonary pressures in PPV and NPV lead to the same changes in lung volume and pressures, yet local tissue strains differ between PPV and NPV. Although limited to healthy specimens and ex vivo experiments in the absence of a chest cavity, these results may explain previous reports of better oxygenation and less lung injury in NPV.


Asunto(s)
Pulmón , Respiración con Presión Positiva , Animales , Porcinos , Respiración con Presión Positiva/métodos , Respiración Artificial/métodos , Ventilación con Presión Positiva Intermitente , Volumen de Ventilación Pulmonar , Mecánica Respiratoria
4.
Acta Biomater ; 155: 410-422, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36328122

RESUMEN

Distal airways commonly obstruct in lung disease and despite their importance, their mechanical properties are vastly underexplored. The lack of bronchial experiments restricts current airway models to either assume rigid structures, or extrapolate the material properties of the trachea to represent the small airways. Furthermore, past works are exclusively limited to uniaxial testing; investigating the multidirectional tensile loads of both the proximal and distal pulmonary airways is long overdue. Here we present comprehensive mechanical and viscoelastic properties of the porcine airway tree, including the trachea, trachealis muscle, large bronchi, and small bronchi, via measures of elasticity, extensibility, and energetics to explore regional and directional dependencies, cross-examining strain rate and preconditioning effects using planar equibiaxial tensile tests for the first time. We find bronchial regions are notably heterogeneous, where the trachea exhibits greater stiffness, energy loss, and preconditioning sensitivity than the smaller airways. Interestingly, the trachealis muscle is similar to the distal bronchi, despite being anatomically located adjacent to the proximal ring. Tissues are anisotropic and axially stiffer under initial loading, losing more energy with greater stress relaxation circumferentially. Strain rate dependency is also noted, where tissues are more energetically efficient at the faster strain rate, likely attributable to the microstructure. Findings highlight assumptions of homogeneity and isotropy are inadequate, and enable the improvement of aerosol flow and dynamic airway deformation computational predictive models. These results provide much needed fundamental material properties for future explorations contrasting healthy versus diseased pulmonary airway mechanics to better understand the relationship between structure and lung function. STATEMENT OF SIGNIFICANCE: We present comprehensive multiaxial mechanical tensile experiments of the proximal and distal airways via measures of maximum stress, initial and ultimate moduli, strain and stress transitions, hysteresis, energy loss, and stress relaxation, and further assess preconditioning and strain rate dependencies to examine the relationship between lung function and structure. The mechanical response of the bronchial tree demonstrates significant anisotropy and heterogeneity, even within the tracheal ring, and emphasizes that contrary to past studies, the behavior of the proximal airways cannot be extended to distal bronchial tree analyses. Establishing these material properties is critical to advancing our understanding of airway function and in developing accurate computational simulations to help diagnose and monitor pulmonary diseases.


Asunto(s)
Bronquios , Pulmón , Animales , Porcinos , Pulmón/fisiología , Tráquea , Elasticidad , Anisotropía , Estrés Mecánico , Fenómenos Biomecánicos
5.
Physiol Rep ; 10(19): e15466, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36207795

RESUMEN

Pulmonary diseases alter lung mechanical properties, can cause loss of function, and necessitate use of mechanical ventilation, which can be detrimental. Investigations of lung tissue (local) scale mechanical properties are sparse compared to that of the whole organ (global) level, despite connections between regional strain injury and ventilation. We examine ex vivo mouse lung mechanics by investigating strain values, local compliance, tissue surface heterogeneity, and strain evolutionary behavior for various inflation rates and volumes. A custom electromechanical, pressure-volume ventilator is coupled with digital image correlation to measure regional lung strains and associate local to global mechanics by analyzing novel pressure-strain evolutionary measures. Mean strains at 5 breaths per minute (BPM) for applied volumes of 0.3, 0.5, and 0.7 ml are 5.0, 7.8, and 11.3%, respectively, and 4.7, 8.8, and 12.2% for 20 BPM. Similarly, maximum strains among all rate and volume combinations range 10.7%-22.4%. Strain values (mean, range, mode, and maximum) at peak inflation often exhibit significant volume dependencies. Additionally, select evolutionary behavior (e.g., local lung compliance quantification) and tissue heterogeneity show significant volume dependence. Rate dependencies are generally found to be insignificant; however, strain values and surface lobe heterogeneity tend to increase with increasing rates. By quantifying strain evolutionary behavior in relation to pressure-volume measures, we associate time-continuous local to global mouse lung mechanics for the first time and further examine the role of volume and rate dependency. The interplay of multiscale deformations evaluated in this work can offer insights for clinical applications, such as ventilator-induced lung injury.


Asunto(s)
Respiración Artificial , Mecánica Respiratoria , Animales , Pulmón , Rendimiento Pulmonar , Mediciones del Volumen Pulmonar , Ratones , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar
6.
Front Bioeng Biotechnol ; 9: 684778, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34765590

RESUMEN

Pulmonary diseases, driven by pollution, industrial farming, vaping, and the infamous COVID-19 pandemic, lead morbidity and mortality rates worldwide. Computational biomechanical models can enhance predictive capabilities to understand fundamental lung physiology; however, such investigations are hindered by the lung's complex and hierarchical structure, and the lack of mechanical experiments linking the load-bearing organ-level response to local behaviors. In this study we address these impedances by introducing a novel reduced-order surface model of the lung, combining the response of the intricate bronchial network, parenchymal tissue, and visceral pleura. The inverse finite element analysis (IFEA) framework is developed using 3-D digital image correlation (DIC) from experimentally measured non-contact strains and displacements from an ex-vivo porcine lung specimen for the first time. A custom-designed inflation device is employed to uniquely correlate the multiscale classical pressure-volume bulk breathing measures to local-level deformation topologies and principal expansion directions. Optimal material parameters are found by minimizing the error between experimental and simulation-based lung surface displacement values, using both classes of gradient-based and gradient-free optimization algorithms and by developing an adjoint formulation for efficiency. The heterogeneous and anisotropic characteristics of pulmonary breathing are represented using various hyperelastic continuum formulations to divulge compound material parameters and evaluate the best performing model. While accounting for tissue anisotropy with fibers assumed along medial-lateral direction did not benefit model calibration, allowing for regional material heterogeneity enabled accurate reconstruction of lung deformations when compared to the homogeneous model. The proof-of-concept framework established here can be readily applied to investigate the impact of assorted organ-level ventilation strategies on local pulmonary force and strain distributions, and to further explore how diseased states may alter the load-bearing material behavior of the lung. In the age of a respiratory pandemic, advancing our understanding of lung biomechanics is more pressing than ever before.

7.
Front Physiol ; 11: 600492, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33343395

RESUMEN

Respiratory illnesses, such as bronchitis, emphysema, asthma, and COVID-19, substantially remodel lung tissue, deteriorate function, and culminate in a compromised breathing ability. Yet, the structural mechanics of the lung is significantly understudied. Classical pressure-volume air or saline inflation studies of the lung have attempted to characterize the organ's elasticity and compliance, measuring deviatory responses in diseased states; however, these investigations are exclusively limited to the bulk composite or global response of the entire lung and disregard local expansion and stretch phenomena within the lung lobes, overlooking potentially valuable physiological insights, as particularly related to mechanical ventilation. Here, we present a method to collect the first non-contact, full-field deformation measures of ex vivo porcine and murine lungs and interface with a pressure-volume ventilation system to investigate lung behavior in real time. We share preliminary observations of heterogeneous and anisotropic strain distributions of the parenchymal surface, associative pressure-volume-strain loading dependencies during continuous loading, and consider the influence of inflation rate and maximum volume. This study serves as a crucial basis for future works to comprehensively characterize the regional response of the lung across various species, link local strains to global lung mechanics, examine the effect of breathing frequencies and volumes, investigate deformation gradients and evolutionary behaviors during breathing, and contrast healthy and pathological states. Measurements collected in this framework ultimately aim to inform predictive computational models and enable the effective development of ventilators and early diagnostic strategies.

8.
Front Bioeng Biotechnol ; 8: 578762, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33195138

RESUMEN

Asthma, emphysema, COVID-19 and other lung-impacting diseases cause the remodeling of tissue structural properties and can lead to changes in conducting pulmonary volume, viscoelasticity, and air flow distribution. Whole organ experimental inflation tests are commonly used to understand the impact of these modifications on lung mechanics. Here we introduce a novel, automated, custom-designed device for measuring the volume and pressure response of lungs, surpassing the capabilities of traditional machines and built to range size-scales to accommodate both murine and porcine tests. The software-controlled system is capable of constructing standardized continuous volume-pressure curves, while accounting for air compressibility, yielding consistent and reproducible measures while eliminating the need for pulmonary degassing. This device uses volume-control to enable viscoelastic whole lung macromechanical insights from rate dependencies and pressure-time curves. Moreover, the conceptual design of this device facilitates studies relating the phenomenon of diaphragm breathing and artificial ventilation induced by pushing air inside the lungs. System capabilities are demonstrated and validated via a comparative study between ex vivo murine lungs and elastic balloons, using various testing protocols. Volume-pressure curve comparisons with previous pressure-controlled systems yield good agreement, confirming accuracy. This work expands the capabilities of current lung experiments, improving scientific investigations of healthy and diseased pulmonary biomechanics. Ultimately, the methodologies demonstrated in the manufacturing of this system enable future studies centered on investigating viscoelasticity as a potential biomarker and improvements to patient ventilators based on direct assessment and comparisons of positive- and negative-pressure mechanics.

SELECCIÓN DE REFERENCIAS