Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 409
Filtrar
1.
Ann Cardiol Angeiol (Paris) ; 73(3): 101764, 2024 May 08.
Artículo en Francés | MEDLINE | ID: mdl-38723317

RESUMEN

Sports-related sudden death is an uncommon event, affecting mainly middle-aged men who practice leisure sports, and is related to unknown coronary artery disease. In athletes, cardiac causes are also predominant, with a greater proportion of structural and electrical heart disease. If first-aid resuscitation measures are initiated, survival easily exceeds 50%, and this is an excellent educational illustration of how to improve the prognosis of non-sport-related cardiac arrest. Prevention of a sport-related cardiovascular event remains difficult, and relies on clinical examination, questioning (including family history) and resting ECG in participants >35 years old. The non-contraindication visit is also an opportunity to pass on to the patient the rules of good sports "hygiene" and life-saving gestures in the event of sudden death during sport in one of the partners (and the importance of regularly educating oneself in life-saving gestures...).

2.
J Am Heart Assoc ; : e033723, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38780180

RESUMEN

BACKGROUND: Studies reporting on the incidence of sudden cardiac arrest and/or death (SCA/D) in athletes commonly lack methodological and reporting rigor, which has implications for screening and preventative policy in sport. To date, there are no tools designed for assessing study quality in studies investigating the incidence of SCA/D in athletes. METHODS AND RESULTS: The International Criteria for Reporting Study Quality for Sudden Cardiac Arrest/Death tool (IQ-SCA/D) was developed following a Delphi process. Sixteen international experts in sports cardiology were identified and invited. Experts voted on each domain with subsequent moderated discussion for successive rounds until consensus was reached for a final tool. Interobserver agreement between a novice, intermediate, and expert observer was then assessed from the scoring of 22 relevant studies using weighted and unweighted κ analyses. The final IQ-SCA/D tool comprises 8 domains with a summated score of a possible 22. Studies are categorized as low, intermediate, and high quality with summated IQ-SCA/D scores of ≤11, 12 to 16, and ≥17, respectively. Interrater agreement was "substantial" between all 3 observers for summated IQ-SCA/D scores and study categorization. CONCLUSIONS: The IQ-SCA/D is an expert consensus tool for assessing the study quality of research reporting the incidence of SCA/D in athletes. This tool may be used to assist researchers, reviewers, journal editors, and readers in contextualizing the methodological quality of different studies with varying athlete SCA/D incidence estimates. Importantly, the IQ-SCA/D also provides an expert-informed framework to support and guide appropriate design and reporting practices in future SCA/D incidence trials.

3.
Lancet Glob Health ; 12(6): e983-e994, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38762298

RESUMEN

BACKGROUND: Early detection and diagnosis of acute rheumatic fever and rheumatic heart disease are key to preventing progression, and echocardiography has an important diagnostic role. Standard echocardiography might not be feasible in high-prevalence regions due to its high cost, complexity, and time requirement. Handheld echocardiography might be an easy-to-use, low-cost alternative, but its performance in screening for and diagnosing acute rheumatic fever and rheumatic heart disease needs further investigation. METHODS: In this systematic review and meta-analysis, we searched Embase, MEDLINE, LILACS, and Conference Proceedings Citation Index-Science up to Feb 9, 2024, for studies on the screening and diagnosis of acute rheumatic fever and rheumatic heart disease using handheld echocardiography (index test) or standard echocardiography or auscultation (reference tests) in high-prevalence areas. We included all studies with useable data in which the diagnostic performance of the index test was assessed against a reference test. Data on test accuracy in diagnosing rheumatic heart disease, acute rheumatic fever, or carditis with acute rheumatic fever (primary outcomes) were extracted from published articles or calculated, with authors contacted as necessary. Quality of evidence was appraised using GRADE and QUADAS-2 criteria. We summarised diagnostic accuracy statistics (including sensitivity and specificity) and estimated 95% CIs using a bivariate random-effects model (or univariate random-effects models for analyses including three or fewer studies). Area under the curve (AUC) was calculated from summary receiver operating characteristic curves. Heterogeneity was assessed by visual inspection of plots. This study was registered with PROSPERO (CRD42022344081). FINDINGS: Out of 4868 records we identified 11 studies, and two additional reports, comprising 15 578 unique participants. Pooled data showed that handheld echocardiography had high sensitivity (0·87 [95% CI 0·76-0·93]), specificity (0·98 [0·71-1·00]), and overall high accuracy (AUC 0·94 [0·84-1·00]) for diagnosing rheumatic heart disease when compared with standard echocardiography (two studies; moderate certainty of evidence), with better performance for diagnosing definite compared with borderline rheumatic heart disease. High sensitivity (0·79 [0·73-0·84]), specificity (0·85 [0·80-0·89]), and overall accuracy (AUC 0·90 [0·85-0·94]) for screening rheumatic heart disease was observed when pooling data of handheld echocardiography versus standard echocardiography (seven studies; high certainty of evidence). Most studies had a low risk of bias overall. Some heterogeneity was observed for sensitivity and specificity across studies, possibly driven by differences in the prevalence and severity of rheumatic heart disease, and level of training or expertise of non-expert operators. INTERPRETATION: Handheld echocardiography has a high accuracy and diagnostic performance when compared with standard echocardiography for diagnosing and screening of rheumatic heart disease in high-prevalence areas. FUNDING: World Health Organization. TRANSLATIONS: For the Chinese, French, Italian, Persian, Portuguese, Spanish and Urdu translations of the abstract see Supplementary Materials section.


Asunto(s)
Ecocardiografía , Cardiopatía Reumática , Humanos , Cardiopatía Reumática/diagnóstico por imagen , Ecocardiografía/estadística & datos numéricos , Ecocardiografía/métodos , Tamizaje Masivo/métodos , Organización Mundial de la Salud , Guías de Práctica Clínica como Asunto , Sensibilidad y Especificidad
4.
Artículo en Inglés | MEDLINE | ID: mdl-38696031

RESUMEN

Secondary prevention with penicillin aims to prevent further episodes of acute rheumatic fever and subsequent development of rheumatic heart disease (RHD). Penicillin allergy, self-reported by 10% of the population, can affect secondary prevention programs. We aimed to assess the role for (i) routine penicillin allergy testing and the (ii) safety of penicillin allergy delabeling approaches in this context. We searched MEDLINE, Embase, CENTRAL, ClinicalTrials.gov, WHO ICTRP, ISRCTN, and CPCI-S to identify the relevant reports. We found 2419 records, but no studies addressed our initial question. Following advice from the WHO-Guideline committee and experts, we identified 6 manuscripts on allergy testing focusing on other populations showing that the prevalence of allergy confirmed by testing was low and the incidence of life-threatening reactions to BPG was very low (< 1-3/1000 individuals treated). A subsequent search addressed penicillin allergy delabeling. This found 516 records, and 5 studies addressing the safety of direct oral drug challenge vs. skin testing followed by drug administration in patients with suspected penicillin allergy. Immediate allergic reactions of minor severity were observed for a minority of patients and occurred less frequently in the direct drug challenge group: 2.3% vs. 11.5%; RR = 0.25, 95%CI 0.15-0.45, P < 0.00001, I2 = 0%. No anaphylaxis or deaths were observed. Severe allergic reactions to penicillin are extremely rare and can be recognized and dealt by trained healthcare workers. Confirmation of penicillin allergy diagnosis or delabeling using direct oral drug challenge or penicillin skin testing seems to be safe and is associated with a low rate of adverse reactions.

5.
Resuscitation ; 199: 110202, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38582445

RESUMEN

BACKGROUND: Controlled donation after circulatory death (cDCD) in post-anoxic brain injury is a valuable source of organs that is still underused in some countries. We assessed the number of potential cDCD donors after out-of-hospital cardiac arrest (OHCA) in Paris and its suburbs and extrapolated the results to the French population. METHODS: Using the large regional registry of the Great Paris area, we prospectively included all consecutive adults with OHCA with a stable return of spontaneous circulation (ROSC) who ultimately died in the intensive care unit (ICU) after withdrawal of life-sustaining treatments (WLST) due to post anoxic brain injury. The primary endpoint was potential for organ donation by cDCD in this population. The number of potential cDCD donors was calculated and extrapolated to the entire French population. RESULTS: Between 2011 and 2018, 4638 patients with stable ROSC were admitted to ICUs after OHCA, and 3170 died in ICU, of which 1034 died after WLST due to post-anoxic brain injury. When considering French criteria, 421/1034 patients (41%) would have been potential cDCD donors (55 patients per year in a 4.67 million population). After standardization for age and sex, the potential for cDCD was 515 (95% CI 471-560) patients per year in France corresponding to an annual incidence of 1.18 per 100 000 inhabitants per year. CONCLUSIONS: Organ donation by cDCD after cardiac arrest could provide a large pool of donors in France.

6.
Glob Heart ; 19(1): 39, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38681969

RESUMEN

Background: Rheumatic Heart Disease (RHD) is the most common cause of valvular heart disease worldwide. Undiagnosed or untreated RHD can complicate pregnancy and lead to poor maternal and fetal outcomes and is a significant factor in non-obstetric morbidity. Echocardiography has an emerging role in screening for RHD. We aimed to critically analyse the evidence on the use of echocardiography for screening pregnant women for RHD in high-prevalence areas. Methods: We searched MEDLINE and Embase to identify the relevant reports. Two independent reviewers assessed the reports against the eligibility criteria in a double-blind process. Results: The searches (date: 4 April 2023) identified 432 records for screening. Ten non-controlled observational studies were identified, five using portable or handheld echocardiography, comprising data from 23,166 women. Prevalence of RHD varied across the studies, ranging from 0.4 to 6.6% (I2, heterogeneity >90%). Other cardiac abnormalities (e.g., congenital heart disease and left ventricular systolic dysfunction) were also detected <1% to 2% of cases. Certainty of evidence was very low. Conclusion: Echocardiography as part of antenatal care in high-prevalence areas may detect RHD or other cardiac abnormalities in asymptomatic pregnant women, potentially reducing the rates of disease progression and adverse labor-associated outcomes. However, this evidence is affected by the low certainty of evidence, and lack of studies comparing echocardiography versus standard antenatal care. Prospective Registration: PROSPERO 2022 July 4; CRD42022344081 Available from: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=344081. Research question: 'In areas with a high prevalence of rheumatic heart disease, should handheld echocardiography be added to routine antenatal care?'


Asunto(s)
Ecocardiografía , Complicaciones Cardiovasculares del Embarazo , Cardiopatía Reumática , Humanos , Cardiopatía Reumática/epidemiología , Cardiopatía Reumática/diagnóstico por imagen , Femenino , Embarazo , Ecocardiografía/métodos , Prevalencia , Complicaciones Cardiovasculares del Embarazo/epidemiología , Complicaciones Cardiovasculares del Embarazo/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Atención Prenatal/métodos
10.
Artículo en Inglés | MEDLINE | ID: mdl-38448258

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

11.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38302391

RESUMEN

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Asunto(s)
Cardiología , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Sociedades Médicas
12.
Heart Rhythm ; 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38336193

RESUMEN

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

13.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38291925

RESUMEN

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Médicos , Accidente Cerebrovascular , Tromboembolia , Adulto , Humanos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Cierre del Apéndice Auricular Izquierdo , Consenso , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Anticoagulantes/efectos adversos , Tromboembolia/etiología , Tromboembolia/prevención & control , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Vitamina K , Apéndice Atrial/cirugía , Resultado del Tratamiento
14.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38234123

RESUMEN

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Asunto(s)
Insuficiencia Cardíaca , Calidad de Vida , Humanos , Estudios de Cohortes , Volumen Sistólico , Estudios Prospectivos , Bancos de Muestras Biológicas , Función Ventricular Izquierda , Algoritmos
15.
Eur Heart J Cardiovasc Pharmacother ; 10(3): 184-189, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38216511

RESUMEN

INTRODUCTION: Atrial arrhythmia is the most common complication of patent foramen ovale (PFO) closure. The real incidence of post-PFO closure atrial arrhytmia and whether this complication can be prevented is unknown. METHODS/DESIGN: The Assessment of Flecainide to Lower the PFO closure risk of Atrial fibrillation or Tachycardia (AFLOAT) trial is a prospective, national, multicentre, randomized, open-label, superiority trial with a blind evaluation of all the endpoints (PROBE design). A total of 186 patients are randomized in a 1:1:1 ratio immediately after PFO closure to receive Flecainide (150 mg per day in a single sustained-release (SR) dose) for 6 months (Group 1), Flecainide (150 mg per day in a single SR dose) for 3 months (Group 2), or no additional treatment (standard of care) for 6 months (Group 3). The primary endpoint is the percentage of patients with at least one episode of symptomatic or asymptomatic atrial arrhythmia episode (≥30 s) recorded within 3 months after PFO closure on long-term monitoring with an insertable cardiac monitor. Whether 3 months of treatment is sufficient compared to 6 months will be analysed as a secondary objective of the study. CONCLUSION: AFLOAT is the first trial to test the hypothesis that a short treatment with oral Flecainide can prevent the new-onset of atrial arrhythmia after PFO closure. CLINICAL TRIAL REGISTRATION: NCT05213104 (clinicaltrials.gov).


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Flecainida , Foramen Oval Permeable , Humanos , Flecainida/efectos adversos , Flecainida/administración & dosificación , Flecainida/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/prevención & control , Estudios Prospectivos , Antiarrítmicos/uso terapéutico , Antiarrítmicos/efectos adversos , Antiarrítmicos/administración & dosificación , Resultado del Tratamiento , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/terapia , Femenino , Masculino , Factores de Tiempo , Adulto , Persona de Mediana Edad , Frecuencia Cardíaca/efectos de los fármacos
16.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
18.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-37956458

RESUMEN

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Asunto(s)
Fibrilación Atrial , Piridinas , Accidente Cerebrovascular , Tiazoles , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/diagnóstico , Anticoagulantes/uso terapéutico
19.
Resuscitation ; 194: 110043, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37952575

RESUMEN

AIM: Prior studies have reported increased out-of-hospital cardiac arrests (OHCA) incidence and lower survival during the COVID-19 pandemic. We evaluated how the COVID-19 pandemic affected OHCA incidence, bystander CPR rate and patients' outcomes, accounting for regional COVID-19 incidence and OHCA characteristics. METHODS: Individual patient data meta-analysis of studies which provided a comparison of OHCA incidence during the first pandemic wave (COVID-period) with a reference period of the previous year(s) (pre-COVID period). We computed COVID-19 incidence per 100,000 inhabitants in each of 97 regions per each week and divided it into its quartiles. RESULTS: We considered a total of 49,882 patients in 10 studies. OHCA incidence increased significantly compared to previous years in regions where weekly COVID-19 incidence was in the fourth quartile (>136/100,000/week), and patients in these regions had a lower odds of bystander CPR (OR 0.49, 95%CI 0.29-0.81, p = 0.005). Overall, the COVID-period was associated with an increase in medical etiology (89.2% vs 87.5%, p < 0.001) and OHCAs at home (74.7% vs 67.4%, p < 0.001), and a decrease in shockable initial rhythm (16.5% vs 20.3%, p < 0.001). The COVID-period was independently associated with pre-hospital death (OR 1.73, 95%CI 1.55-1.93, p < 0.001) and negatively associated with survival to hospital admission (OR 0.68, 95%CI 0.64-0.72, p < 0.001) and survival to discharge (OR 0.50, 95%CI 0.46-0.54, p < 0.001). CONCLUSIONS: During the first COVID-19 pandemic wave, there was higher OHCA incidence and lower bystander CPR rate in regions with a high-burden of COVID-19. COVID-19 was also associated with a change in patient characteristics and lower survival independently of COVID-19 incidence in the region where OHCA occurred.


Asunto(s)
COVID-19 , Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Humanos , COVID-19/epidemiología , COVID-19/complicaciones , Reanimación Cardiopulmonar/efectos adversos , Pandemias , Paro Cardíaco Extrahospitalario/epidemiología , Paro Cardíaco Extrahospitalario/terapia , Paro Cardíaco Extrahospitalario/etiología
20.
JACC Clin Electrophysiol ; 10(1): 1-12, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37855774

RESUMEN

BACKGROUND: There are few data on ventricular fibrillation (VF) initiation in patients with inferolateral J waves. OBJECTIVES: This multicenter study investigated the characteristics of triggers initiating spontaneous VF in inferolateral J-wave syndrome. METHODS: A total of 31 patients (age 37 ± 14 years, 24 male) with spontaneous VF episodes associated with inferolateral J waves were evaluated to determine the origin and characteristics of triggers. The J-wave pattern was recorded in inferior leads in 11 patients, lateral leads in 3, and inferolateral leads in 17. RESULTS: The VF triggers (n = 37) exhibited varying QRS durations (176 ± 21 milliseconds, range 119-219 milliseconds) and coupling intervals (339 ± 46 milliseconds, range 250-508 milliseconds) with a right (70%) or left (30%) bundle branch block (BBB) pattern. Trigger patterns were associated with J-wave location: left BBB triggers with inferior J waves and right BBB triggers with lateral J waves. Electrophysiologic study was performed for 22 VF triggers in 19 patients. They originated from the left or right Purkinje system in 6 and from the ventricular myocardium in 10 and were undetermined in 6. Purkinje vs myocardial triggers showed distinct electrocardiographic characteristics in coupling interval and QRS-complex duration and morphology. Abnormal epicardial substrate associated with fragmented electrograms was identified in 9 patients, with triggers originating from the same region in 7 patients. Catheter ablation resulted in VF suppression in 15 patients (79%). CONCLUSIONS: VF initiation in inferolateral J-wave syndrome is associated with significant individual heterogeneity in trigger characteristics. Myocardial triggers have electrocardiographic features distinct from Purkinje triggers, and their origin often colocalizes with an abnormal epicardial substrate.


Asunto(s)
Síndrome de Brugada , Fibrilación Ventricular , Humanos , Masculino , Adulto Joven , Adulto , Persona de Mediana Edad , Electrocardiografía/métodos , Trastorno del Sistema de Conducción Cardíaco , Ventrículos Cardíacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA