Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Talanta ; 77(5): 1660-6, 2009 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19159780

RESUMEN

This paper proposes a simple and non-expensive electroanalytical methodology for classification of edible vegetable oils with respect to type (canola, sunflower, corn and soybean) and conservation state (expired and non-expired shelf life). The proposed methodology employs an alcoholic extraction procedure followed by square wave voltammetry (SWV). Two chemometric methods were compared for classification of the resulting voltammograms, namely Soft Independent Modelling of Class Analogy (SIMCA) and Linear Discriminant Analysis (LDA) with variable selection by the Successive Projections Algorithm (SPA). The results were evaluated in terms of errors in a set of samples not included in the modelling process. The best results were obtained with the SPA-LDA method, which correctly classified all samples in terms of type and conservation state.


Asunto(s)
Electroquímica/métodos , Aceites de Plantas/clasificación , Algoritmos , Análisis de los Alimentos , Conservación de Alimentos , Análisis Multivariante , Extractos Vegetales , Aceites de Plantas/análisis
2.
Talanta ; 75(1): 15-21, 2008 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-18371840

RESUMEN

The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the simultaneous determination of Pb(II), Cu(II) and Hg(II) ions in natural water and sugar cane spirit (cachaça) is described. Pb(II), Cu(II) and Hg(II) were pre-concentrated on the surface of the modified electrode by complexing with 2-benzothiazolethiol and reduced at a negative potential (-0.80 V). Then the reduced products were oxidised by DPASV procedure. The fact that three stripping peaks appeared on the voltammograms at the potentials of -0.48 V (Pb2+), -0.03 V (Cu2+) and +0.36 V (Hg2+) in relation to the SCE, demonstrates the possibility of simultaneous determination of Pb2+, Cu2+ and Hg2+. The best results were obtained under the following optimised conditions: 100 mV pulse amplitude, 3 min accumulation time, 25 mV s(-1) scan rate in phosphate solution pH 3.0. Using such parameters, calibration graphs were linear in the concentration ranges of 3.00-70.0 x 10(-7) mol L(-1) (Pb2+), 8.00-100.0 x 10(-7) mol L(-1) (Cu2+) and 2.00-10.0 x 10(-6) mol L(-1) (Hg2+). Detection limits of 4.0 x 10(-8) mol L(-1) (Pb2+), 2.0 x 10(-7) mol L(-1) (Cu2+) and 4.0 x 10(-7) mol L(-1) (Hg2+) were obtained at the signal noise ratio (SNR) of 3. The results indicate that this electrode is sensitive and effective for simultaneous determination of Pb2+, Cu2+ and Hg2+ in the analysed samples.

3.
Talanta ; 59(5): 1021-8, 2003 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-18968993

RESUMEN

The determination of cadmium using a carbon paste electrode modified with organofunctionalized amorphous silica with 2-benzothiazolethiol was investigated. The Cd(II) oxidation peak was observed around -0.80 V (vs. SCE) in phosphate buffer (pH 4.0) in differential pulse anodic stripping voltammetry. The best results were obtained under the following optimized conditions: 1 min accumulation time, 50 mV pulse amplitude, 20 mV s(-1) scan rate in phosphate buffer pH 4.0. Using such parameters a linear dynamic range from 5.6 x 10(-7) to 3.5 x 10(-5) mol l(-1) Cd(II) was observed with a sensitivity of 2.83 microA mol(-1) l, limit of detection 1.0 x 10(-7) mol l(-1). Cd(II) spiked in a natural water sample was determined with 99% mean recovery at 10(-7) mol l(-1) level. Interference were also evaluated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...