Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Open Access Emerg Med ; 13: 335-341, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34349568

RESUMEN

OBJECTIVE: Traditional treatment of abscesses in the emergency department includes packing with gauze; however, this can add pain and discomfort to the procedure and frequently involves a follow-up visit for packing removal. Alternatives to gauze packing have been proposed, but they may have disadvantages in the context of emergency care. The objective of this pilot study was to investigate the use of a novel silicone packing device - the Derma-Stent. METHODS: This was a randomized controlled pilot study of 50 patients from two urban emergency departments with uncomplicated superficial abscesses. The primary outcome was the likelihood of self-removal of packing gauze versus the silicone device. Secondary outcome measures included subjective clinician and patient metrics, such as pain and ease of use. RESULTS: Patients identified with simple cutaneous abscesses were randomized to intervention (packing with the novel silicone device, n=25) or standard care (gauze packing, n=25). Mean age was 36 years, 54% were female, and 96% identified as African American. Although it took longer to place, the silicone device (19.0 vs 15.3 minutes, p=0.03), pain scores were significantly lower (4.3/10 vs 7.1/10, p=0.008) and ease of use reported by physicians better in the silicone-device group (4.8/5 vs 4.0/5, p=0.002). A high unknown rate in the gauze-packing group limits discussion of the likelihood of self-removal; however, the silicone device was more likely to remain in place (60%) versus the gauze packing at 3 days (24%, p=0.01). CONCLUSION: This pilot randomized controlled trial compared the treatment of packing cutaneous abscesses with gauze versus using the silicone device. Limitations in the data prevent discussion on likelihood of self-removal. However, the silicone device was more likely to remain in place at day 3 follow-up and was equally effective to gauze packing in abscess reduction while also improving patient-reported pain scores. It did take longer to place the silicone device; however, physicians reported better ease of use and removal. This pilot study is encouraging for additional larger-scale trials that are required to further assess the utility of this device in the emergency department.

2.
J Emerg Med ; 56(3): 298-300, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30661820

RESUMEN

BACKGROUND: Superficial skin abscesses are commonly encountered in emergency medicine practice. Standard treatment includes incision, drainage, and often packing with a gauze strip. The packing component of the procedure has several negative potential outcomes, is painful, and necessitates a return visit for removal. DISCUSSION: Here we report the first case in which a novel silicon packing device was utilized. The patient presented with a facial abscess, which was incised and drained. The novel device was inserted, and removed by the patient independently, without complication. Both patient and provider reported satisfaction with the novel procedure, and noted low pain scores. CONCLUSIONS: This device has the potential to replace traditional packing, and will require further study through a controlled trial to assess for safety and efficacy.


Asunto(s)
Absceso/cirugía , Silicio/uso terapéutico , Cuidados de la Piel/instrumentación , Adulto , Vendajes/normas , Humanos , Maxilares/efectos de los fármacos , Maxilares/lesiones , Masculino , Silicio/farmacología , Cuidados de la Piel/métodos , Cuidados de la Piel/tendencias , Herida Quirúrgica , Cicatrización de Heridas/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...