Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Radiat Res ; 187(3): 273-286, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28218888

RESUMEN

The utility of early-phase (≤5 days) radiation-induced clinical signs and symptoms (e.g., vomiting, diarrhea, erythema and changes in blood cell counts) was examined for the prediction of later occurring acute radiation syndrome (ARS) severity and the development of medical management strategies. Medical treatment protocols for radiation accident victims (METREPOL) was used to grade ARS severities, which were assigned response categories (RCs). Data on individuals (n = 191) with mild (RC1, n = 45), moderate (RC2, n = 19), severe (RC3, n = 20) and fatal (RC4, n = 18) ARS, as well as nonexposed individuals (RC0, n = 89) were generated using either METREPOL (n = 167) or the system for evaluation and archiving of radiation accidents based on case histories (SEARCH) database (n = 24), the latter comprised of real-case descriptions. These data were converted into tables reflecting clinical signs and symptoms, and submitted to eight teams representing five participating countries. The teams were comprised of medical doctors, biologists and pharmacists with subject matter expertise. The tables comprised cumulated clinical data from day 1-3 and day 1-5 postirradiation. While it would have reflected a more realistic scenario to provide the data to the teams over the course of a 3- or 5-day period, the logistics of doing so proved too challenging. In addition, the team members participating in this exercise chose to receive the cumulated reports of day 1-3 and 1-5. The teams were tasked with predicting ARS incidence, ARS severity and the requirement for hospitalization for multiple cases, as well as providing the certainty of their diagnosis. Five of the teams also performed dose estimates. The teams did not employ harmonized methodologies, and the expertise among the members varied, as did the tools used and the means of analyzing the clinical data. The earliest report time was 3 h after the tables were sent to the team members. The majority of cases developing ARS (89.6% ± 3.3 SD) and requiring hospitalization (88.8% ± 4.6 SD) were correctly identified by all teams. Determination of ARS severity was particularly challenging for RC2-3, which was systematically overestimated. However, RC4 was correctly predicted at 94-100% by all teams. RC0 and RC1 ARS severities were more difficult to discriminate. When reported RCs (0-1 and 3-4) were merged, on average 89.6% (±3.3 SD) of all cases could be correctly classified. Comparisons on frequency distributions revealed no statistically significant differences among the following: 1. reported ARS from different teams (P > 0.2); 2. cases generated based on METREPOL or SEARCH (P > 0.5); or 3. results reported at day 3 and 5 postirradiation (P > 0.1). Dose estimates of all teams increased significantly along with ARS severity (P < 0.0001) as well as with dose estimates generated from dicentric chromosomal-aberration measurements available for SEARCH cases (P < 0.0001). In summary, early-phase radiation-induced clinical signs and symptoms proved to be useful for rapid and accurate assessment, with minor limitations, toward predicting life-threatening ARS severity and developing treatment management strategies.


Asunto(s)
Síndrome de Radiación Aguda/diagnóstico , Incidentes con Víctimas en Masa , Síndrome de Radiación Aguda/terapia , Hospitalización , Humanos , Agencias Internacionales , Dosis de Radiación , Liberación de Radiactividad Peligrosa , Factores de Tiempo
2.
Radiat Res ; 180(2): 111-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23862692

RESUMEN

Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.


Asunto(s)
Bioensayo/métodos , Cromosomas Humanos/efectos de la radiación , Roturas del ADN de Doble Cadena/efectos de la radiación , Histonas/metabolismo , Ensayos de Aptitud de Laboratorios , Leucocitos/efectos de la radiación , Pruebas de Micronúcleos , Radiometría/métodos , Adulto , Células Cultivadas/efectos de los fármacos , Células Cultivadas/efectos de la radiación , Aberraciones Cromosómicas , Citocinesis/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Expresión Génica/efectos de la radiación , Humanos , Leucocitos/ultraestructura , Masculino , Fosforilación , Procesamiento Proteico-Postraduccional , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Liberación de Radiactividad Peligrosa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Factores de Tiempo , Triaje/métodos
3.
Radiat Res ; 180(2): 129-37, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23862730

RESUMEN

The study design and obtained results represent an intercomparison of various laboratories performing dose assessment using the dicentric chromosome analysis (DCA) as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. DCA was performed according to established protocols. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 2.4 days after sample arrival. DCA dose estimates were reported with high and comparable accuracy, with MAD values ranging between 0.16-0.5 Gy for both manual and automated scoring. No significant differences were found for dose estimates based either on 20, 30, 40 or 50 cells, suggesting that the scored number of cells can be reduced from 50 to 20 without loss of precision of triage dose estimates, at least for homogenous exposure scenarios. Triage categories of clinical significance could be discriminated efficiently using both scoring procedures.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas , Cromosomas Humanos/efectos de la radiación , Ensayos de Aptitud de Laboratorios , Leucocitos/efectos de la radiación , Radiometría/métodos , Adulto , Automatización , Calibración , Cromosomas Humanos/ultraestructura , Relación Dosis-Respuesta en la Radiación , Dosimetría por Película , Humanos , Leucocitos/ultraestructura , Masculino , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Liberación de Radiactividad Peligrosa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Factores de Tiempo , Triaje/métodos
4.
Radiat Res ; 180(2): 120-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23862731

RESUMEN

The focus of the study is an intercomparison of laboratories' dose-assessment performances using the cytokinesis-block micronucleus (CBMN) assay as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. The CBMN assay was performed according to protocols individually established and varying among participating laboratories. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 4 days after sample arrival. The CBMN dose estimates were reported with high accuracy (MAD values of 0.20-0.50 Gy at doses below 6.4 Gy for both manual and automated scoring procedures), but showed a limitation of the assay at the dose point of 6.4 Gy, which resulted in a clear dose underestimation in all cases. The MAD values (without 6.4 Gy) differed significantly (P = 0.03) between manual (0.25 Gy, SEM = 0.06, n = 4) or automated scoring procedures (0.37 Gy, SEM = 0.08, n = 5), but lowest MAD were equal (0.2 Gy) for both scoring procedures. Likewise, both scoring procedures led to the same allocation of dose estimates to triage categories of clinical significance (about 83% accuracy and up to 100% specificity).


Asunto(s)
Bioensayo/métodos , Ensayos de Aptitud de Laboratorios , Leucocitos/efectos de la radiación , Pruebas de Micronúcleos/métodos , Radiometría/métodos , Adulto , Automatización , Células Cultivadas/efectos de la radiación , Células Cultivadas/ultraestructura , Citocinesis/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Humanos , Leucocitos/ultraestructura , Masculino , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Liberación de Radiactividad Peligrosa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Factores de Tiempo , Triaje/métodos
5.
Ann Readapt Med Phys ; 49(1): 1-7, 2006 Feb.
Artículo en Francés | MEDLINE | ID: mdl-16122828

RESUMEN

OBJECTIVE: This study aimed to determine whether ordinary clinical performance on the timed "up-and-go" and one-leg-balance tests varied with additional cognitive tasks and the predictive value of this combination for future falls. METHODOLOGY: The sample comprised 95 women with osteoporosis who lived independently in the community and were older than 70 years (mean 73.4+/-1.7 years) who were randomized to perform the timed "up-and-go" (TUG) and one-leg-balance (OLB) tests. The tests were performed with or without an additional cognitive task (math task involving subtraction by 2 s or 5 s or addition by 3 s). RESULTS: For both TUG and OLB, performance decreased in the dual-task condition (P<0.05) but did not differ in older women with and without a history of falling, whatever the test, and with or without an additional cognitive load. CONCLUSION: Performance on the TUG and OLB tests was less efficient when patients simultaneously performed a cognitive task. Performance on these tests, without or with cognitive tasks, did not predict falls in a sample of women who lived independently.


Asunto(s)
Accidentes por Caídas , Cognición/fisiología , Evaluación Geriátrica/métodos , Equilibrio Postural/fisiología , Anciano , Femenino , Humanos , Osteoporosis Posmenopáusica/fisiopatología , Valor Predictivo de las Pruebas , Análisis y Desempeño de Tareas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...