Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Virchows Arch ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532196

RESUMEN

The estimation of tumor cellular fraction (TCF) is a crucial step in predictive molecular pathology, representing an entry adequacy criterion also in the next-generation sequencing (NGS) era. However, heterogeneity of quantification practices and inter-pathologist variability hamper the robustness of its evaluation, stressing the need for more reliable results. Here, 121 routine histological samples from non-small cell lung cancer (NSCLC) cases with complete NGS profiling were used to evaluate TCF interobserver variability among three different pathologists (pTCF), developing a computational tool (cTCF) and assessing its reliability vs ground truth (GT) tumor cellularity and potential impact on the final molecular results. Inter-pathologist reproducibility was fair to good, with overall Wk ranging between 0.46 and 0.83 (avg. 0.59). The obtained cTCF was comparable to the GT (p = 0.129, 0.502, and 0.130 for surgical, biopsies, and cell block, respectively) and demonstrated good reliability if elaborated by different pathologists (Wk = 0.9). Overall cTCF was lower as compared to pTCF (30 ± 10 vs 52 ± 19, p < 0.001), with more cases < 20% (17, 14%, p = 0.690), but none containing < 100 cells for the algorithm. Similarities were noted between tumor area estimation and pTCF (36 ± 29, p < 0.001), partly explaining variability in the human assessment of tumor cellularity. Finally, the cTCF allowed a reduction of the copy number variations (CNVs) called (27 vs 29, - 6.9%) with an increase of effective CNVs detection (13 vs 7, + 85.7%), some with potential clinical impact previously undetected with pTCF. An automated computational pipeline (Qupath Analysis of Nuclei from Tumor to Uniform Molecular tests, QuANTUM) has been created and is freely available as a QuPath extension. The computational method used in this study has the potential to improve efficacy and reliability of TCF estimation in NSCLC, with demonstrated impact on the final molecular results.

2.
J Clin Pathol ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538076

RESUMEN

AIM: The digital transformation of the pathology laboratory is being continuously sustained by the introduction of innovative technologies promoting whole slide image (WSI)-based primary diagnosis. Here, we proposed a real-life benchmark of a pathology-dedicated medical monitor for the primary diagnosis of renal biopsies, evaluating the concordance between the 'traditional' microscope and commercial monitors using WSI from different scanners. METHODS: The College of American Pathologists WSI validation guidelines were used on 60 consecutive renal biopsies from three scanners (Aperio, 3DHISTECH and Hamamatsu) using pathology-dedicated medical grade (MG), professional grade (PG) and consumer-off-the-shelf (COTS) monitors, comparing results with the microscope diagnosis after a 2-week washout period. RESULTS: MG monitor was faster (1090 vs 1159 vs 1181 min, delta of 6-8%, p<0.01), with slightly better performances on the detection of concurrent diseases compared with COTS (κ=1 vs 0.96, 95% CI=0.87 to 1), but equal concordance to the commercial monitors on main diagnosis (κ=1). Minor discrepancies were noted on specific scores/classifications, with MG and PG monitors closer to the reference report (r=0.98, 95% CI=0.83 to 1 vs 0.98, 95% CI=0.83 to 1 vs 0.91, 95% CI=0.76 to 1, κ=0.93, 95% CI=077 to 1 vs 0.93, 95% CI=0.77 to 1 vs 0.86, 95% CI=0.64 to 1, κ=1 vs 0.50, 95% CI=0 to 1 vs 0.50, 95% CI=0 to 1, for IgA, antineutrophilic cytoplasmic antibody and lupus nephritis, respectively). Streamlined Pipeline for Amyloid detection through congo red fluorescence Digital Analysis detected amyloidosis on both monitors (4 of 30, 13% cases), allowing detection of minimal interstitial deposits with slight overestimation of the Amyloid Score (average 6 vs 7). CONCLUSIONS: The digital transformation needs careful assessment of the hardware component to support a smart and safe diagnostic process. Choosing the display for WSI is critical in the process and requires adequate planning.

3.
Lab Invest ; 103(11): 100243, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37634845

RESUMEN

Renal amyloidosis is a rare condition caused by the progressive accumulation of misfolded proteins within glomeruli, vessels, and interstitium, causing functional decline and requiring prompt treatment due to its significant morbidity and mortality. Congo red (CR) stain on renal biopsy samples is the gold standard for diagnosis, but the need for polarized light is limiting the digitization of this nephropathology field. This study explores the feasibility and reliability of CR fluorescence on virtual slides (CRFvs) in evaluating the diagnostic accuracy and proposing an automated digital pipeline for its assessment. Whole-slide images from 154 renal biopsies with CR were scanned through a Texas red fluorescence filter (NanoZoomer S60, Hamamatsu) at the digital Nephropathology Center of the Istituto di Ricovero e Cura a Carattere Scientifico San Gerardo, Monza, Italy, and evaluated double-blinded for the detection and quantification through the amyloid score and a custom ImageJ pipeline was built to automatically detect amyloid-containing regions. Interobserver agreement for CRFvs was optimal (k = 0.90; 95% CI, 0.81-0.98), with even better concordance when consensus-based CRFvs evaluation was compared to the standard CR birefringence (BR) (k = 0.98; 95% CI, 0.93-1). Excellent performance was achieved in the assessment of amyloid score overall by CRFvs (weighted k = 0.70; 95% CI, 0.08-1), especially within the interstitium (weighted k = 0.60; 95% CI, 0.35-0.84), overcoming the misinterpretation of interstitial and capsular collagen BR. The application of an automated digital pathology pipeline (Streamlined Pipeline for Amyloid detection through CR fluorescence Digital Analysis, SPADA) further increased the performance of pathologists, leading to a complete concordance with the standard BR. This study represents an initial step in the validation of CRFvs, demonstrating its general reliability in a digital nephropathology center. The computational method used in this study has the potential to facilitate the integration of spatial omics and artificial intelligence tools for the diagnosis of amyloidosis, streamlining its detection process.


Asunto(s)
Amiloidosis , Rojo Congo , Humanos , Reproducibilidad de los Resultados , Inteligencia Artificial , Amiloide/metabolismo , Coloración y Etiquetado , Amiloidosis/diagnóstico por imagen , Amiloidosis/metabolismo
4.
FASEB J ; 37(7): e23020, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37342943

RESUMEN

Colon adenocarcinoma (COAD) has a limited range of diversified, personalized therapeutic opportunities, besides DNA hypermutating cases; thus, both new targets or broadening existing strategies for personalized intervention are of interest. Routinely processed material from 246 untreated COADs with clinical follow-up was probed for evidence of DNA damage response (DDR), that is, the gathering of DDR-associated molecules at discrete nuclear spots, by multiplex immunofluorescence and immunohistochemical staining for DDR complex proteins (γH2AX, pCHK2, and pNBS1). We also tested the cases for type I interferon response, T-lymphocyte infiltration (TILs), and mutation mismatch repair defects (MMRd), known to be associated with defects of DNA repair. FISH analysis for chromosome 20q copy number variations was obtained. A total of 33.7% of COAD display a coordinated DDR on quiescent, non-senescent, non-apoptotic glands, irrespective of TP53 status, chromosome 20q abnormalities, and type I IFN response. Clinicopathological parameters did not differentiate DDR+ cases from the other cases. TILs were equally present in DDR and non-DDR cases. DDR+ MMRd cases were preferentially retaining wild-type MLH1. The outcome after 5FU-based chemotherapy was not different in the two groups. DDR+ COAD represents a subgroup not aligned with known diagnostic, prognostic, or therapeutic categories, with potential new targeted treatment opportunities, exploiting the DNA damage repair pathways.


Asunto(s)
Adenocarcinoma , Neoplasias del Colon , Humanos , Daño del ADN/genética , Variaciones en el Número de Copia de ADN , Neoplasias del Colon/genética , Reparación del ADN/genética , Fenotipo
5.
J Histochem Cytochem ; 69(10): 659-667, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34541944

RESUMEN

Antigen-bearing proteins become progressively unavailable to immunodetection after prolonged storage of routine sections, exposed to a variety of agents, such as moisture, oxygen, and temperature. By proteomic analysis, the antigens are retained in the sections and definitely in the tissue block, pointing to fixation-independent, storage time-dependent protein modifications. Based on previous experience, we hypothesized that a combined exposure to a reducing agent and to chemicals favoring protein conformation changes would reverse the masking in aged sections. Disaccharides, lactose and sucrose, and a surfactant, added to a standard antigen retrieval buffer, reverse the negative changes in aged sections. Furthermore, they provide enhanced access to antigens in freshly cut sections, but not universally, revealing additional factors, besides heat and calcium chelation, required for antigen retrieval of individual proteins.


Asunto(s)
Antígenos/análisis , Proteínas/análisis , Humanos , Adhesión en Parafina , Conformación Proteica , Tensoactivos/química , Análisis de Matrices Tisulares , Fijación del Tejido
6.
J Histochem Cytochem ; 69(8): 535-541, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34282664

RESUMEN

Immunodetection on mouse routinely processed tissue via antibodies raised in mice faces cross-reactivity of the secondary anti-mouse reagents with endogenous immunoglobulins, which permeate the tissue. Various solutions to this problem have been devised and include endogenous Ig block with anti-mouse Fab fragments or directly conjugated primary antibodies. Mouse isotype-specific antibodies, differently from reagents directed against both heavy and light chains, fail to detect endogenous Ig after fixation and embedding, while providing a clean and specific detection system for mouse antibodies on mouse routinely processed tissue.


Asunto(s)
Anticuerpos Monoclonales/química , Inmunoconjugados/química , Fragmentos Fab de Inmunoglobulinas/química , Isotipos de Inmunoglobulinas/química , Inmunohistoquímica/métodos , Indicadores y Reactivos/química , Animales , Reacciones Cruzadas/inmunología , Inmunohistoquímica/normas , Mucosa Intestinal/citología , Mucosa Intestinal/metabolismo , Ganglios Linfáticos/citología , Ganglios Linfáticos/metabolismo , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Ratas , Ratas Sprague-Dawley , Bazo/citología , Bazo/metabolismo
7.
Biotechniques ; 70(3): 137-148, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33541132

RESUMEN

Background: Antibody validation for tissue staining is required for reproducibility; criteria to ensure validity have been published recently. The majority of these recommendations imply the use of routinely processed (formalin-fixed, paraffin-embedded) tissue. Materials & methods: We applied to lightly fixed frozen sections a panel of 126 antibodies validated for formalin-fixed, paraffin-embedded tissue with extended criteria. Results: Less than 30% of the antibodies performed as expected with all fixations. 35% preferred one fixation over another, 13% gave nonspecific staining and 23% did not stain at all. Conclusion: Individual antibody variability of the paratope's fitness for the fixed antigen may be the cause. Revalidation of established antibody panels is required when they are applied to sections whose fixation and processing are different from the tissue where they were initially validated.


Asunto(s)
Anticuerpos Monoclonales , Formaldehído , Secciones por Congelación , Colorantes , Fijadores , Adhesión en Parafina , Reproducibilidad de los Resultados , Fijación del Tejido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...