Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(2)2021 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-33477338

RESUMEN

Several studies were devoted to the design of molecularly imprinted polymer (MIP)-based sensors for the detection of a given protein. Here, we bring elements that could contribute to the understanding of the interaction mechanism involved in the recognition of a protein by an imprint. For this purpose, a polydopamine (PDA)-MIP was designed for bovine serum albumin (BSA) recognition. Prior to BSA grafting, the gold surfaces were functionalized with mixed self-assembled monolayers of (MUDA)/(MHOH) (1/9, v/v). The MIP was then elaborated by dopamine electropolymerization and further extraction of BSA templates by incubating the electrode in proteinase K solution. Three complementary techniques, electrochemistry, zetametry, and Fourier-transform infrared spectrometry, were used to investigate pH and ionic strength effects on a MIP's design and the further recognition process of the analytes by the imprints. Several MIPs were thus designed in acidic, neutral, and basic media and at various ionic strength values. Results indicate that the most appropriate conditions, to achieve a successful MIPs, were an ionic strength of 167 mM and a pH of 7.4. Sensitivity and dissociation constant of the designed sensor were of order of (3.36 ± 0.13) µA·cm-2·mg-1·mL and (8.56 ± 6.09) × 10-11 mg/mL, respectively.


Asunto(s)
Concentración Osmolar , Concentración de Iones de Hidrógeno , Indoles , Impresión Molecular , Polímeros
2.
Biosens Bioelectron ; 151: 111978, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-31999585

RESUMEN

Rapid and accurate detection of proteins in biological fluids is increasingly required in the biomedical environment. Actually, it is performed with conventional techniques, which are generally run by robotized platforms at centralized laboratories. In this work, molecular dynamics calculations and an experimental procedure were conducted to set up electrochemical sensors based on polypyrrol (PPy) molecular imprinted polymers (MIP) for proteins detection. Here, prostate-specific antigen (PSA) was selected as a template model. Computational calculations indicate that for any PPy conformation and any amino-acid location in the protein, PSA molecules remain strongly inserted in the PPy polymer without biological alterations. One from possible orientations, appeared to be most probable as it presents the lowest absorption energy (-363 kcal mol-1) and largest contact area (4034.1 Å2). The device was then elaborated by in situ electropolymerization of PPy films. MIP's thickness and extraction duration were optimized by chronoamperometry. Square wave voltammetry technique was investigated for PSA detection in standard solution in the concentration range of 3x10 -8 ng.ml-1- 300 ng ml-1. According to the Hill equation, the equilibrium dissociation constant Kdbetween PSA and its imprint was estimated at Kd = (1.02 ±â€¯0.54) × 10-14 M, confirming the strong binding between the designed MIP and the protein as predicted by the computational study. PSA concentration values directly measured in 35 human serum samples were found closely correlated to those measured by the ELISA technique. The promising fast and low-cost sensor might be used successfully for proteins detection at low concentrations with high selectivity and reproducibility.


Asunto(s)
Técnicas Biosensibles , Impresión Molecular , Antígeno Prostático Específico/aislamiento & purificación , Proteínas/aislamiento & purificación , Humanos , Límite de Detección , Conformación Molecular , Polímeros/química , Antígeno Prostático Específico/genética , Proteínas/genética
3.
Colloids Surf B Biointerfaces ; 181: 489-497, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31176121

RESUMEN

Extensive use of porous silicon (PSi) for tissue engineering is due to its convenient properties as it is both nontoxic and bioresorbable. Moreover, PSi surface modification is an important step to enhance cell adhesion and proliferation. In this work, a combination of optical and electrochemical studies is performed to elaborate a suitable PSi multilayer substrate for cell culture. For this study, we modified PSi surface by silanization and antibody grafting (APTES-anti STRO1), the 12-mer specific peptide to silicon p + type coating and the peptide modified with the antibody recognition sequence. Electrochemical characterization of PSi multilayers is performed to investigate its electrical behavior, determine the optimal measuring conditions and reveal the most stable PSi surfaces. Then, the behavior of dental pulp stem cells (DPSC) was investigated on various modified PSi surfaces. An electrochemical method was applied for the first time monitoring the electrical behavior of stem cell adhesion. The cells electrochemical behavior depends on the nature of the surface coating and the peptide-anti STRO1 improved adhesion and cell spreading onto the PSi surface compared to bare surface and the one coated with the peptide. Fluorescent microscopy revealed that all surface modification methods enhance cell adhesion compared to the bare PSi surface. An increased cell number is observed on APTES-anti STRO1, peptide and peptide-anti STRO1 coated PSi. The peptide-anti STRO1 provided the best cell proliferation results suggesting the improved accessibility of the recognition fragment of the antibody anti-STRO1.


Asunto(s)
Pulpa Dental/citología , Técnicas Electroquímicas , Imagen Óptica , Silicio/química , Células Madre/citología , Adhesión Celular , Proliferación Celular , Células Cultivadas , Humanos , Tamaño de la Partícula , Porosidad , Propiedades de Superficie
4.
Sensors (Basel) ; 17(11)2017 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-29120397

RESUMEN

There is a global debate and concern about the use of glyphosate (Gly) as an herbicide. New toxicological studies will determine its use in the future under new strict conditions or its replacement by alternative synthetic or natural herbicides. In this context, we designed biomimetic polymer sensing layers for the selective molecular recognition of Gly. Towards this end, complementary surface acoustic wave (SAW) and electrochemical sensors were functionalized with polypyrrole (PPy)-imprinted polymer for the selective detection of Gly. Their corresponding limits of detection were on the order of 1 pM, which are among the lowest values ever reported in literature. The relevant dissociation constants between PPy and Gly were estimated at [Kd1 = (0.7 ± 0.3) pM and Kd2 = (1.6 ± 1.4) µM] and [Kd1 = (2.4 ± 0.9) pM and Kd2 = (0.3 ± 0.1) µM] for electrochemical and gravimetric measurements, respectively. Quantum chemical calculations permitted to estimate the interaction energy between Gly and PPy film: ΔE = -145 kJ/mol. Selectivity and competitivity tests were investigated with the most common pesticides. This work conclusively shows that gravimetric and electrochemical results indicate that both MIP-based sensors are perfectly able to detect and distinguish glyphosate without any ambiguity.

5.
Biosens Bioelectron ; 48: 293-8, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23714847

RESUMEN

A silicon nitride functionalized electrode and a 104 MHz lithium tantalate (LiTaO3) surface acoustic wave (SAW) sensor have been used to investigate target-probe recognition processes. Electrochemical and gravimetric measurements have been considered to monitor hybridization of single base mismatch (SBM) in synthetic oligonucleotides and single-nucleotide polymorphisms ApoE in real clinical genotypes. Obvious discrimination of SBM in nucleotides has been shown by both gravimetric and electrochemical techniques, without labeling nor amplification. Investigations on mismatches nature and position have also been considered. For guanine-adenine (GA), guanine-thymine (GT) and guanine-guanine (GG) mismatches, the sensors responses present a dependence upon positions. Considering the capacitance variations and hybridization rates, results showed that gravimetric transduction is more sensitive than electrochemical one. Moreover, the highest value of GT hybridization rate (in the middle position) was found in accordance with the nearest-neighbor model, where the considered configuration appears as the most thermodynamically stable. For the real samples, where the electrochemical transduction, by combining capacitance and flat-band potential measurements, were found more sensitive, the results show that the realized sensor permits an unambiguous discrimination of recognition between fully complementary, non-complementary and single base mismatched targets, and even between the combination of differently matched strands.


Asunto(s)
Apolipoproteínas E/genética , Disparidad de Par Base , ADN/genética , Técnicas Electroquímicas/métodos , Polimorfismo de Nucleótido Simple , Técnicas Biosensibles/métodos , Gravitación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...