RESUMEN
Significant progress has been made over the years to improve the stability and efficiency of rapidly evolving tin-based perovskite solar cells (PSCs). One powerful approach to enhance the performance of these PSCs is through compositional engineering techniques, specifically by incorporating a mixed cation system at the A-site and B-site structure of the tin perovskite. These approaches will pave the way for unlocking the full potential of tin-based PSCs. Therefore, in this study, a theoretical investigation of mixed A-cations (FA, MA, EA, Cs) with a tin-germanium-based PSC was presented. The crystal structure distortion and optoelectronic properties were estimated. SCAPS 1-D simulations were employed to predict the photovoltaic performance of the optimized tin-germanium material using different electron transport layers (ETLs), hole transport layers (HTLs), active layer thicknesses, and cell temperatures. Our findings reveal that EA0.5Cs0.5Sn0.5Ge0.5I3 has a nearly cubic structure (t = 0.99) and a theoretical bandgap within the maximum Shockley-Queisser limit (1.34 eV). The overall cell performance is also improved by optimizing the perovskite layer thickness to 1200 nm, and it exhibits remarkable stability as the temperature increases. The short-circuit current density (Jsc) remains consistent around 33.7 mA/cm2, and the open-circuit voltage (Voc) is well-maintained above 1 V by utilizing FTO as the conductive layer, ZnO as the ETL, Cu2O as the HTL, and Au as the metal back contact. This configuration also achieves a high fill factor ranging from 87 % to 88 %, with the highest power conversion efficiency (PCE) of 31.49 % at 293 K. This research contributes to the advancement of tin-germanium perovskite materials for a wide range of optoelectronic applications.
RESUMEN
A highly sensitive silicon nanowire (SiNW)-based sensor device was developed using electron beam lithography integrated with complementary metal oxide semiconductor (CMOS) technology. The top-down fabrication approach enables the rapid fabrication of device miniaturization with uniform and strictly controlled geometric and surface properties. This study demonstrates that SiNW devices are well-aligned with different widths and numbers for pH sensing. The device consists of a single nanowire with 60 nm width, exhibiting an ideal pH responsivity (18.26 × 106 Ω/pH), with a good linear relation between the electrical response and a pH level range of 4-10. The optimized SiNW device is employed to detect specific single-stranded deoxyribonucleic acid (ssDNA) molecules. To use the sensing area, the sensor surface was chemically modified using (3-aminopropyl) triethoxysilane and glutaraldehyde, yielding covalently linked nanowire ssDNA adducts. Detection of hybridized DNA works by detecting the changes in the electrical current of the ssDNA-functionalized SiNW sensor, interacting with the targeted ssDNA in a label-free way. The developed biosensor shows selectivity for the complementary target ssDNA with linear detection ranging from 1.0 × 10-12 M to 1.0 × 10-7 M and an attained detection limit of 4.131 × 10-13 M. This indicates that the use of SiNW devices is a promising approach for the applications of ion detection and biomolecules sensing and could serve as a novel biosensor for future biomedical diagnosis.
RESUMEN
Cardiovascular disease (CVD) is a major threat to global health, estimated to be the cause 30 % (17.3 million in 2008) of deaths every year, and the number of deaths caused by CVD is expected to increase further, reaching 23.3 million by 2030. Hence, there is a growing demand for simpler sample extraction, rapid screening results, and intervention of the subsequent analysis in emergency units. In this paper, we reviewed CVD biomarkers in blood- and saliva-based specimens. The history of cardiac biomarkers indicates that in the beginning, cardiac troponin I (cTnI) was a widely accepted 'gold standard' marker due to its high specificity and selectivity. Considering the advantages of salivary-based cardiac biomarkers, we examined correlations between non-invasive (salivary) and invasive (blood) diagnoses, and it was found that C-reactive protein (CRP) provides a better correlation. Despite the low abundance of salivary CRP, several reports displayed the detection limit down to pg/ml using existing technologies. Thus, salivary CRP has the potential to be used for future forefront diagnostics for the early assessment of cardiac risks.