RESUMEN
Background: Certain causes of death can be avoided with access to timely prevention and treatment. We quantified trends in avoidable deaths from cardiovascular diseases for European Union (EU) countries from 1995 to 2020 and examined variations by demographics, disease characteristics, and geography. Methods: Retrospective secondary data analysis of avoidable cardiovascular mortality using the WHO Mortality Database. Avoidable causes of death were identified from the OECD and Eurostat list (which uses an age threshold of 75 years). Regression models were used to identify changes in the trends of age-standardized mortality rates and potential years of life lost. Findings: From 1995 to 2020, 11.4 million deaths from cardiovascular diseases in Europe were avoidable, resulting in 213.1 million potential life years lost. Avoidable deaths were highest among males (7.5 million), adults 65-74 years (6.8 million), and with the leading cause of death being ischemic heart disease (6.1 million). From its peak in 1995 until 2020, avoidable mortality from cardiovascular diseases has decreased by 57% across the EU. The difference in avoidable cardiovascular diseases mortality between females and males, and between Eastern and Western Europe has reduced greatly, however gaps continue to persist. Interpretation: Avoidable mortality from cardiovascular diseases has decreased substantially among EU countries, although improvement has not been uniform across diseases, demographic groups or regions. These trends suggest additional policy interventions are needed to ensure that improvements in mortality are continued. Funding: World Health Organization, Regional Office for Europe.
RESUMEN
Hypertension is the most significant risk factor for cardiovascular disease and mortality worldwide, affecting 1.3 billion adults. Global disparities in hypertension control are widening with low- and middle-income countries (LMIC) having the fastest growing rates of hypertension and low rates of control. Treatment for hypertension can be challenging, with multiple drug classes and dosing schedules. Combination antihypertensives have been suggested as a solution for their efficacy and potential to improve adherence. Global consumption of combination and non-combination antihypertensives across 75 countries and 2 regions from 2010 to 2021 was estimated using the IQVIA MIDAS database on pharmaceutical sales. Consumption rates were standardized using Standard Units (SUs) and analysed by high-income (HIC), upper-middle income (UMIC), and LMIC income classification. Global median consumption rate of all antihypertensives per 1000 inhabitants per day increased from 184.78 SUs in 2010 to 325.6 SUs in 2021, with HICs consistently having the highest rates. Median consumption rates of combination and non-combination antihypertensives increased across all country income groups but combination drugs were consumed at a lower rate and proportion. LMICs consumed a higher percentage of combination antihypertensives relative to non-combination (45.5%) than UMICs (24.3%) and HICs (24.4%) in 2021. While combination antihypertensives may be preferred for their potential for increased adherence and effectiveness, their global uptake is inconsistent. HICs consume less combination medication relative to non-combination, despite higher overall consumption rates of antihypertensives. LMICs show increasing use of combination medications, indicating a shift towards their use.
RESUMEN
Although the use of hepatitis C virus (HCV)-positive hearts has been shown to be safe and effective among donors with donation after brain death (DBD), it remains unknown whether such organs recovered after circulatory death (DCD) have similar outcomes. In contradistinction to recovery from DBD using cold static organ storage, DCD procurement processes typically use normothermic-perfusion transport strategies that necessitate the use of a large volume of donor blood and involve exposure to temperatures oscillating between cold to dominantly normothermic conditions. We performed a retrospective analysis of United Network for Organ Sharing (UNOS) registry data in the United States and found that clinical outcomes do not differ with respect to rates of treated allograft rejection, early and 1-year survival. Ideally, the organ-recovery source should not result in a bias in organ-offer acceptance from HCV-positive donors, although long-term outcome data are yet unavailable.
RESUMEN
OBJECTIVE: Waitlist time for United Network for Organ Sharing Status 2 heart transplant candidates has steadily increased. We compared a bridging strategy using either the Impella 5.0/5.5 ("Impella") or intra-aortic balloon pump with a durable left ventricular assist device in patients with blood type O stratified by body habitus. METHODS: The United Network for Organ Sharing registry was queried for adults listed for de novo heart transplantation (without dialysis) supported by the Impella, an intra-aortic balloon pump, or the HeartMate 3 left ventricular assist device. The primary outcome was 1-year postlisting survival, defined as the sum of waitlist time and post-heart transplant survival time if the candidate underwent heart transplantation. RESULTS: In total, 2942 candidates were included (Impella: 214; intra-aortic balloon pump: 1326; HeartMate 3: 1402). Listing with the Impella or intra-aortic balloon pump was associated with worse postlisting survival compared with the HeartMate 3 left ventricular assist device in type O candidates (Impella: hazard ratio, 2.90 [95% CI, 1.48-5.67], P = .002; intra-aortic balloon pump: hazard ratio, 2.42 [95% CI, 1.59-3.68], P < .001) but less so in non-type O candidates. Further analysis of type O candidates demonstrated that the Impella and intra-aortic balloon pump were associated with a lower risk of postlisting mortality among those with normal height (25-75th percentile) and nonobese (body mass index <30) (Impella: hazard ratio, 1.78 [95% CI, 0.61-5.18], P = .292; intra-aortic balloon pump: hazard ratio, 1.28 [95% CI, 0.67-2.45], P = .455); among those not of normal height and nonobese, the Impella and intra-aortic balloon pump were associated with an elevated risk of postlisting mortality (Impella: hazard ratio, 3.65 [95% CI, 1.68-7.95], P = .001; intra-aortic balloon pump: hazard ratio, 3.01 [95% CI, 1.95-4.67], P < .001). CONCLUSIONS: Blood type O candidates listed with the Impella or intra-aortic balloon pump are at increased risk of postlisting mortality compared with a durable left ventricular assist device in the current organ allocation era. These effects are diminished among those with normal height and body habitus.
RESUMEN
Long-term outcomes of patients with advanced heart failure treated with durable left ventricular assist devices (LVADs) have been augmented due to improved durability and hemocompatibility on the backbone of pump engineering enhancements. The incidence of hemocompatibility-related adverse events (pump thrombosis, stroke and nonsurgical bleeding events) are device specific and vary by type of engineered pump. A fully magnetically levitated rotor containing LVAD in concert with use of antithrombotic therapy has successfully overcome an increased risk of pump thrombosis and stroke-risk, albeit with only modest reduction in bleeding events. Modifications to antithrombotic strategies have focused on reduced-dose vitamin K antagonist use or use of direct oral anticoagulants with demonstration of safety and progress in reduction of mucosal bleeding episodes with elimination of antiplatelet agents. This review outlines the current landscape of advances in anticoagulation management in LVAD patients, highlighting the need for ongoing research and cautious application of emerging therapies and technologies.
RESUMEN
BACKGROUND: Hemocompatibility-related adverse events affect patients after left ventricular assist device (LVAD) implantation but are hard to predict. OBJECTIVES: Dynamic risk modeling with a multistate model can predict risk of gastrointestinal bleeding (GIB), stroke, or death in ambulatory patients. METHODS: This was a secondary analysis of the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3) trial. HeartMate 3 LVAD recipients who survived to hospital discharge and were followed for up to 2 years. A total of 145 variables were included in the multistate model with multivariate logistic regression. Model performance was assessed with the area under the curve in a holdout validation cohort. A risk stratification tool was created by dividing patients into categories of predicted risk using the final model variables and associated OR. RESULTS: Among 2,056 LVAD patients, the median age was 59.4 years (20.4% women, 28.6% Black). At 2 years, the incidence of GIB, stroke, and death was 25.6%, 6.0%, and 12.3%, respectively. The multistate model included 39 total variables to predict risk of GIB (16 variables), stroke (10 variables), and death (19 variables). When ambulatory patients were classified according to their risk category, the 30-day observed event rate in the highest risk group for GIB, stroke, or death was 26.9%, 1.8%, and 4.8%, respectively. The multistate model predicted GIB, stroke, and death at any 30-day period with an area under the curve of 0.70, 0.69, and 0.86, respectively. CONCLUSIONS: The multistate model informs 30-day risk in ambulatory LVAD recipients and allows recalculation of risk as new patient-specific data become available. The model allows for accurate risk stratification that predicts impending adverse events and may guide clinical decision making. (MOMENTUM 3 IDE Clinical Study Protocol; NCT02224755).
RESUMEN
BACKGROUND: Clonal hematopoiesis of indeterminate potential (CHIP) mutations, a trait of aging, has been associated with the progression of cardiovascular disease and the development of malignancy. Uncertainty prevails regarding a robust association between CHIP and heart-transplantation (HT) outcomes. OBJECTIVES: To determine the prevalence of CHIP mutations in HT and their association with long-term outcomes, including cardiac allograft vasculopathy (CAV), graft failure, malignancy, and all-cause mortality. METHODS: We conducted a mixed retrospective-prospective observational study of HT recipients with targeted sequencing for CHIP mutations (variant allele frequency [VAF] of ≥ 2%). The primary composite outcome was the first occurrence of CAV grade ≥ 2, graft failure, malignancy, cardiac retransplantation, or all-cause death. Secondary outcomes were the individual components of the composite primary outcome. Sensitivity analyses with base-case and extreme scenarios were performed. RESULTS: Among 95 HT recipients, 30 had CHIP mutations (31.6%). DNMT3A mutations were most common (44.7%), followed by PPM1D (13.2%), SF3B1 (10.5%), TET2 (7.9%), and TP53 (7.9%). The only significant independent predictor of CHIP was age at enrollment or age at transplantation. After multivariable adjustment, CHIP mutations were not associated with the primary outcome, which occurred in 44 (46.3%) patients (HRâ¯=â¯0.487; 95% CI:0.197-1.204; Pâ¯=â¯0.119), nor were they associated with mlalignancy alone, or death. CONCLUSION: We demonstrated no association between CHIP mutations and post-transplant outcomes, including CAV, graft failure, malignancy, and all-cause mortality. In line with previously published data, our analysis provides additional evidence about the lack of clinical value of using CHIP mutations as a biomarker for surveillance in outcomes after HT.
RESUMEN
Right heart failure (RHF) following implantation of a left ventricular assist device (LVAD) is a common and potentially serious condition with a wide spectrum of clinical presentations with an unfavourable effect on patient outcomes. Clinical scores that predict the occurrence of right ventricular (RV) failure have included multiple clinical, biochemical, imaging and haemodynamic parameters. However, unless the right ventricle is overtly dysfunctional with end-organ involvement, prediction of RHF post-LVAD implantation is, in most cases, difficult and inaccurate. For these reasons optimization of RV function in every patient is a reasonable practice aiming at preparing the right ventricle for a new and challenging haemodynamic environment after LVAD implantation. To this end, the institution of diuretics, inotropes and even temporary mechanical circulatory support may improve RV function, thereby preparing it for a better adaptation post-LVAD implantation. Furthermore, meticulous management of patients during the perioperative and immediate postoperative period should facilitate identification of RV failure refractory to medication. When RHF occurs late during chronic LVAD support, this is associated with worse long-term outcomes. Careful monitoring of RV function and characterization of the origination deficit should therefore continue throughout the patient's entire follow-up. Despite the useful information provided by the echocardiogram with respect to RV function, right heart catheterization frequently offers additional support for the assessment and optimization of RV function in LVAD-supported patients. In any patient candidate for LVAD therapy, evaluation and treatment of RV function and failure should be assessed in a multidimensional and multidisciplinary manner.
RESUMEN
Hutchinson-Gilford Progeria Syndrome (HGPS) is an ultra-rare genetic premature aging disease that is historically fatal in teenage years, secondary to severe accelerated atherosclerosis. The only approved treatment is the farnesyltransferase inhibitor lonafarnib, which improves vascular structure and function, extending average untreated lifespan of 14.5 years by 4.3 years (30%). With this longer lifespan, calcific aortic stenosis (AS) was identified as an emerging critical risk factor for cardiac death in older patients. Intervention to relieve critical AS has the potential for immediate improvement in healthspan and lifespan. However, HGPS patient-device size mismatch, pervasive peripheral arterial disease, skin and bone abnormalities, and lifelong failure to thrive present unique challenges to intervention. An international group of experts in HGPS, pediatric and adult cardiology, cardiac surgery, and pediatric critical care convened to identify strategies for successful treatment. Candidate procedures were evaluated by in-depth examination of 4 cases that typify HGPS clinical pathology. Modified transcatheter aortic valve replacement (TAVR) and left ventricular Apico-Aortic Conduit (AAC) placement were deemed high risk but viable options. Two cases received TAVR and 2 received AAC post-summit. Three were successful and 1 patient died perioperatively due to cardiovascular disease severity, highlighting the importance of intervention timing and comparative risk stratification. These breakthrough interventions for treating critical aortic stenosis in HGPS patients could rewrite the current clinical perspective on disease course by greatly improving late-stage quality of life and increasing lifespan. Expanding worldwide medical and surgical competency for this ultra-rare disease through expert information-sharing could have high impact on treatment success.
Asunto(s)
Anticoagulantes , Corazón Auxiliar , Humanos , Estudios Prospectivos , Anticoagulantes/administración & dosificación , Anticoagulantes/uso terapéutico , Administración Oral , Masculino , Femenino , Persona de Mediana Edad , Resultado del Tratamiento , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Patients with left ventricular assist devices (LVADs) require interruption of warfarin for invasive procedures, but parenteral bridging is associated with many complications. Four-factor prothrombin complex concentrate (4F-PCC) can temporarily restore hemostasis in patients undergoing anticoagulation with warfarin. OBJECTIVES: This pilot study evaluated the strategy of using variable-dose 4F-PCC to immediately and temporarily reverse warfarin before invasive procedures without holding warfarin in patients with LVADs. The duration of effect of 4F-PCC on factor levels and time to reestablish therapeutic anticoagulation post procedure were assessed. METHODS: Adult patients with LVADs and planned invasive procedures were enrolled from a single center. Warfarin was continued uninterrupted. The 4F-PCC dose administered immediately pre-procedure was based on study protocol. International normalized ratio (INR)- and vitamin K-dependent factor levels were collected before and during the 48 hours after 4F-PCC administration. The use of parenteral bridging, International Society for Thrombosis and Haemostasis major and clinically relevant nonmajor bleeding (CRNMB) and thromboembolic events at 7 and 30 days were collected. RESULTS: In 21 episodes of 4F-PCC reversal, median baseline INR was 2.7 (IQR 2.2-3.2). The median dosage of 4F-PCC administered was 1794 units (IQR 1536-2130). At 24 and 48 hours post 4F-PCC administration, median INRs were 1.8 (IQR 1.7-2.0) and 2.0 (IQR 1.9-2.4). Two patients required postoperative bridging. One patient experienced major bleeding within 72 hours, and 2 experienced CRNMB within 30 days. There were no thromboembolic events. Baseline and post 4F-PCC vitamin K-dependent factor levels corresponded with changes in INR values. The median time to achieve therapeutic INR post-procedure was 2.5 days (IQR, 1-4). CONCLUSION: Administration of 4F-PCC for temporary reversal of warfarin for invasive procedures in patients with LVADs allowed for continued warfarin dosing with minimal use of post-intervention bridging, limited bleeding and no thromboembolic events.
Asunto(s)
Anticoagulantes , Factores de Coagulación Sanguínea , Corazón Auxiliar , Relación Normalizada Internacional , Warfarina , Humanos , Warfarina/administración & dosificación , Warfarina/uso terapéutico , Corazón Auxiliar/efectos adversos , Femenino , Masculino , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Persona de Mediana Edad , Proyectos Piloto , Factores de Coagulación Sanguínea/administración & dosificación , Factores de Coagulación Sanguínea/uso terapéutico , Anciano , Insuficiencia Cardíaca/tratamiento farmacológico , Estudios Prospectivos , Tromboembolia/prevención & control , AdultoRESUMEN
BACKGROUND: Trials evaluating implantable hemodynamic monitors to manage patients with heart failure (HF) have shown reductions in HF hospitalizations but not mortality. Prior meta-analyses assessing mortality have been limited in construct because of an absence of patient-level data, short-term follow-up duration, and evaluation across the combined spectrum of ejection fractions. OBJECTIVES: The purpose of this meta-analysis was to determine whether management with implantable hemodynamic monitors reduces mortality in patients with heart failure and reduced ejection fraction (HFrEF) and to confirm the effect of hemodynamic-monitoring guided management on HF hospitalization reduction reported in previous studies. METHODS: The patient-level pooled meta-analysis used 3 randomized studies (GUIDE-HF [Hemodynamic-Guided Management of Heart Failure], CHAMPION [CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients], and LAPTOP-HF [Left Atrial Pressure Monitoring to Optimize Heart Failure Therapy]) of implantable hemodynamic monitors (2 measuring pulmonary artery pressures and 1 measuring left atrial pressure) to assess the effect on all-cause mortality and HF hospitalizations. RESULTS: A total of 1,350 patients with HFrEF were included. Hemodynamic-monitoring guided management significantly reduced overall mortality with an HR of 0.75 (95% CI: 0.57-0.99); P = 0.043. HF hospitalizations were significantly reduced with an HR of 0.64 (95% CI: 0.55-0.76); P < 0.0001. CONCLUSIONS: Management of patients with HFrEF using an implantable hemodynamic monitor significantly reduces both mortality and HF hospitalizations. The reduction in HF hospitalizations is seen early in the first year of monitoring and mortality benefits occur after the first year.
Asunto(s)
Insuficiencia Cardíaca , Monitorización Hemodinámica , Disfunción Ventricular Izquierda , Humanos , Volumen Sistólico , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Prótesis e Implantes , Hemodinámica , Diuréticos , HospitalizaciónRESUMEN
OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.
RESUMEN
BACKGROUND: Personalized risk (PR) estimates may enhance clinical decision making and risk communication by providing individualized estimates of patient outcomes. We explored stakeholder attitudes toward the utility, acceptability, usefulness and best-practices for integrating PR estimates into patient education and decision making about Left Ventricular Assist Device (LVAD). METHODS AND RESULTS: As part of a 5-year multi-institutional AHRQ project, we conducted 40 interviews with stakeholders (physicians, nurse coordinators, patients, and caregivers), analyzed using Thematic Content Analysis. All stakeholder groups voiced positive views towards integrating PR in decision making. Patients, caregivers and coordinators emphasized that PR can help to better understand a patient's condition and risks, prepare mentally and logistically for likely outcomes, and meaningfully engage in decision making. Physicians felt it can improve their decision making by enhancing insight into outcomes, enhance tailored pre-emptive care, increase confidence in decisions, and reduce bias and subjectivity. All stakeholder groups also raised concerns about accuracy, representativeness and relevance of algorithms; predictive uncertainty; utility in relation to physician's expertise; potential negative reactions among patients; and overreliance. CONCLUSION: Stakeholders are optimistic about integrating PR into clinical decision making, but acceptability depends on prospectively demonstrating accuracy, relevance and evidence that benefits of PR outweigh potential negative impacts on decision making quality.
Asunto(s)
Corazón Auxiliar , Médicos , Humanos , Toma de Decisiones , Educación del Paciente como Asunto , ActitudRESUMEN
Silicone is utilized widely in medical devices for its compatibility with tissues and bodily fluids, making it a versatile material for implants and wearables. To effectively bond silicone devices to biological tissues, a reliable adhesive is required to create a long-lasting interface. BioAdheSil, a silicone-based bioadhesive designed to provide robust adhesion on both sides of the interface is introduced here, facilitating bonding between dissimilar substrates, namely silicone devices and tissues. The adhesive's design focuses on two key aspects: wet tissue adhesion capability and tissue-infiltration-based long-term integration. BioAdheSil is formulated by mixing soft silicone oligomers with siloxane coupling agents and absorbents for bonding the hydrophobic silicone device to hydrophilic tissues. Incorporation of biodegradable absorbents eliminates surface water and controls porosity, while silane crosslinkers provide interfacial strength. Over time, BioAdheSil transitions from nonpermeable to permeable through enzyme degradation, creating a porous structure that facilitates cell migration and tissue integration, potentially enabling long-lasting adhesion. Experimental results demonstrate that BioAdheSil outperforms commercial adhesives and elicits no adverse response in rats. BioAdheSil offers practical utility for adhering silicone devices to wet tissues, including long-term implants and transcutaneous devices. Here, its functionality is demonstrated through applications such as tracheal stents and left ventricular assist device lines.
Asunto(s)
Adhesivos , Siliconas , Ratas , Animales , Ensayo de Materiales , Interacciones Hidrofóbicas e Hidrofílicas , Agua/químicaRESUMEN
BACKGROUND: The authors tested the hypothesis that physiological information from sensors within a minimally invasive, subcutaneous, insertable cardiac monitor (ICM) could be used to develop an ambulatory heart failure risk score (HFRS) to accurately identify heart failure (HF) patients, across the ejection fraction spectrum, at high risk of an impending worsening heart failure event (HFE). OBJECTIVES: The purpose of this study was to examine performance of ICM-based, multiparameter, dynamic HFRS to predict HFEs in patients with NYHA functional class II/III HF. METHODS: In 2 observational cohorts, HF patients were implanted with an ICM; subcutaneous impedance, respiratory rate, heart rate and variability, atrial fibrillation burden, ventricular rate during atrial fibrillation, and activity duration were combined into an HFRS to identify the probability of HFE within 30 days. Patients and providers were blinded to the data. HFRS sensitivity and unexplained detection rate were defined in 2 independent patient population data sets. HFEs were defined as hospitalization, observation unit, or emergency department visit with a primary diagnosis of HF, and intravenous diuretic treatment. RESULTS: First data set (development): 42 patients had 19 HFE; second data set (validation): 94 patients had 19 HFE (mean age 66 ± 11 years, 63% men, 50% with LVEF ≥40%, 80% NYHA functional class III). Using a high-risk threshold = 7.5%, development and validation data sets: sensitivity was 73.7% and 68.4%; unexplained detection rate of 1.4 and 1.5 per patient-year; median 47 and 64 days early warning before HFE. CONCLUSIONS: ICM-HFRS provides a multiparameter, integrated diagnostic method with the ability to identify when HF patients are at increased risk of heart failure events. (Reveal LINQ Evaluation of Fluid [REEF]; NCT02275923, Reveal LINQ Heart Failure [LINQ HF]; NCT02758301, Algorithm Using LINQ Sensors for Evaluation and Treatment of Heart Failure [ALLEVIATE-HF]; NCT04452149).